Keysight Technologies 8490D, 8491A, 8490G, 8491B, 8493B Operating And Service Manual

...
Keysight 8490D/G, 8491A/B, 8493A/B/C Coaxial Fixed Attenuators
Keysight 11581A, 11582A, 11583C Attenuator Sets
Operating and
Service Manual
CAUTION
WARNING
Copyright Notice
© Keysight Technologies 2014 - 2019 No part of this manual may be repro-
duced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Keysight Technol­ogies as governed by United States and international copyright laws.
Manual Part Number
08491-90077
Edition
Edition 6, June 26, 2019
Printed in:
Printed in Malaysia
Published by:
Keysight Technologies Bayan Lepas Free Industrial Zone, 11900 Penang, Malaysia
Technology Licenses
The hard ware and/or software described in this document are fur­nished under a license and may be used or copied only in accordance with the terms of such license.
Declaration of Conformity
Declarations of Conformity for this product and for other Keysight prod­ucts may be downloaded from the Web. Go to http://www.keysight.com/
go/conformity. You can then search by
product number to find the latest Dec­laration of Conformity.
U.S. Government Rights
The Software is “commercial computer software,” as defined by Federal Acqui­sition Regulation (“FAR”) 2.101. Pursu­ant to FAR 12.212 and 27.405-3 and Department of Defense FAR Supple­ment (“DFARS”) 227.7202, the U.S. government acquires commercial com­puter software under the same terms by which the software is customarily provided to the public. Accordingly, Keysight provides the Software to U.S. government customers under its stan­dard commercial license, which is embodied in its End User License Agreement (EULA), a copy of which can be found at http://www.keysight.com/
find/sweula. The license set forth in the
EULA represents the exclusive authority by which the U.S. government may use, modify, distribute, or disclose the Soft­ware. The EULA and the license set forth therein, does not require or per­mit, among other things, that Keysight:
urnish technical informat
(1) F r
elated to commercial computer soft­ware or commercial computer software documentation that is not customaril pr
ovided to the public; or (2) Relinquish to, or otherwise provide, the govern­ment rights in excess of these rights customarily provided to the public to use, modify, reproduce, release, per­form, display, or disclose commercial computer software or commercial com­puter software documentation. ad
ditional government requirements beyond those set forth in the EULA shall apply, except to the extent th those
terms, rights, or licenses ar
icitly required from all providers of
expl commercial computer software pursu­ant to the FAR and the DFARS and ar
forth specifically in writing else-
set where in the EULA. Keysight shall be under no obligation to update, revise or otherwise modify the Software. r
espect to any technical data as
defined by FAR 2.101, pursuant to FA
12.211 and
227.7102, the U.S. a
cquires no greater than Limited Rights
as defined in FAR 27.401 or DF
227.7103-5 (c), as
echnical data.
t
27.404.2 and DFAR governme
applicable in
ion
y
No
at
e
e
With
R
S
nt
AR
any
Warranty
THE MATERIAL CONTAINED IN THIS DOCUMENT IS PROVIDED “AS IS,” AND IS SUBJECT TO BEING CHANGED, WITHOUT NOTICE, IN FUTURE EDITIONS. FURTHER, TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, KEYSIGHT DIS­CLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, WITH REGARD TO THIS MANUAL AND ANY INFORMA­TION CONTAINED HEREIN, INCLUD­ING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MER­CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. KEYSIGHT SHALL NOT BE LIABLE FOR ERRORS OR FOR INCIDENTAL OR CONSE­QUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, USE, OR PERFORMANCE OF THIS DOCUMENT OR OF ANY INFORMATION CON­TAINED HEREIN. SHOULD KEYSIGHT AND THE USER HAVE A SEPARATE WRITTEN AGREEMENT WITH WAR­RANTY TERMS COVERING THE MATE­RIAL IN THIS DOCUMENT THAT CONFLICT WITH THESE TERMS, THE WARRANTY TERMS IN THE SEPARATE AGREEMENT SHALL CONTROL.
Safety Information
A CAUTION notice denotes a hazard. It calls attention to an operating proce­dure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not pro­ceed beyond a CAUTION notice until the indicated conditions are fully understood and met.
A WARNING notice denotes a hazard. It calls attention to an operating proce­dure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met.
2 Keysight 849x and 1158x Operating and Service Manual

Waste Electrical and Electronic Equipment (WEEE) Directive

This instrument complies with the WEEE Directive marking requirement. This affixed product label indicates that you must not discard this electrical or electronic product in domestic household waste.

Product category:

With reference to the equipment types in the WEEE directive Annex 1, this instrument is classified as a “Monitoring and Control Instrument” product.
The affixed product label is as shown below.
Do not dispose in domestic household waste.
To return this unwanted instrument, contact your nearest Keysight Service Center, or visit http://about.keysight.com/en/companyinfo/environment/takeback.shtml for more information.

Sales and Technical Support

To contact Keysight for sales and technical support, refer to the support links on the following Keysight websites:
www.keysight.com/find/attenuators
(product-specific information and support, software and documentation updates)
www.keysight.com/find/assist
(worldwide contact information for repair and service)
Keysight 849x and 1158x Operating and Service Manual 3
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.
4 Keysight 849x and 1158x Operating and Service Manual

Table of Contents

Waste Electrical and Electronic Equipment (WEEE) Directive . . . . . . . .3
Product category: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Sales and Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
List of Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
List of Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Attenuator overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Optional calibration data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Attenuator sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Initial inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Returning attenuators under warranty . . . . . . . . . . . . . . . . . . . . . . .21
Operating Instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Operator’s check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Using oscillator and SWR meter . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Using network analyzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Making Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
8490D/G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
8491A/B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
8493A/B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
8493C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Performance Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Service Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Keysight 849x and 1158x Operating and Service Manual 5
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.
6 Keysight 849x and 1158x Operating and Service Manual

List of Figures

Figure 1 Equipment setup using oscillator and SWR meter . . .22
Figure 2 Equipment setup using network analyzer . . . . . . . . . .24
Figure 3 2.4-mm/1.85mm connector diagram . . . . . . . . . . . . .25
Figure 4 Type-N connector diagram . . . . . . . . . . . . . . . . . . . . .26
Figure 5 SMA connector diagram . . . . . . . . . . . . . . . . . . . . . . .27
Figure 6 3.5-mm connector diagram . . . . . . . . . . . . . . . . . . . . .28
Keysight 849x and 1158x Operating and Service Manual 7
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.
8 Keysight 849x and 1158x Operating and Service Manual

List of Tables

Table 1 List of coaxial fixed attenuators . . . . . . . . . . . . . . . . . .11
Table 2 List of attenuator boxed sets . . . . . . . . . . . . . . . . . . . .12
Table 3 Specifications for 8490D coaxial fixed attenuator . . . . 13
Table 4 Specifications for 8490G coaxial fixed attenuator . . . . 14
Table 5 Specifications for 8491A and 8493A coaxial fixed
attenuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Table 6 Specifications for 8491B and 8493B coaxial fixed
attenuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Table 7 Specifications for 8493C coaxial fixed attenuator . . . .18
Table 8 Accuracy of insertion loss measurements (S Table 9 Accuracy of reflection coefficient measurements (S
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
S
22
, S12). .19
21
,
11
Table 10 849x coaxial fixed attenuator and 1158x attenuator sets
environmental specifications . . . . . . . . . . . . . . . . .20
Table 11 SWR verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Keysight 849x and 1158x Operating and Service Manual 9
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.
10 Keysight 849x and 1158x Operating and Service Manual