Keysight (Agilent) N9360A Technical Overview

Agilent N9360A Mobile Station Tester
Technical Overview
Go/No go multi-format cellular device tester for mobile station service and repair with built-in PC
When your cellular phone repair, manufacturing, or R&D testing needs require cost-effective mobile device parametric and call processing measurements, use the Agilent N9360A mobile station tester.
This low-cost, go/no-go tester provides “just enough” capability to make it easy to evaluate protocol as well as RF transmitter and receiver performance. User-friendly, automated test operations enable phone test by operators with little or no technical expertise. The N9360A is an ideal solution for “quick check” call testing in R&D and basic calibration testing in manufacturing
The lightweight N9360A has an internal PC controller with LAN and GPIB connectivity. Test measurements display on the N9360A screen and can be stored as .csv files in a thumb drive, or printed on an Epson PM-G800 printer. Upgradeable hardware and firmware facilitates adding new wireless technologies to support next generation networks.
The N9360A is designed to help you meet your time-to-market goals, keep production costs low, and provide a platform that can change with the market.
Key Features
Multi-format test
o GSM/GPRS/EGPRS o W-CDMA o HSDPA o Cdma2000® o 1xEV-DO
Quad-band GSM/GPRS/EGPRS
SMS test
W-CDMA Bands I to VI
Twelve traffic-channel test in automatic mode
ACLR and SEM measurement capability
FM (frequency modulation) capability
Receiver sensitivity support in GPRS ETSI A and ETSI B mode
Support for EGPRS SRB loopback BLER
1
1
Avoid testing interference from real networks with a fully automated test system
The Agilent GS-8210 system is a pre-configured test system which combines the N9360A mobile station tester with the N9360A-S01 shield box and Agilent N9360A-W36 GS-8210 multi-format test software - offering a cost effective functional test system designed for cellular phone inspection and repair.
Figure 1. GS-8210 test system with N9360A, shield box, and test software
2
1
Requires N9360AU-100 hardware installed in unit
Technical Specifications
Specifications describe the test set’s warranted performance and are valid over the entire operation and environmental ranges unless otherwise noted.
Supplemental characteristics are intended to provide additional information useful in applying the instrument by giving typical, but non-warranted performance parameters. These characteristics are shown in italics and labeled as typical, or supplemental.
GSM/GPRS/EGPRS
Frequency (MHz) Band Uplink Downlink
GSM850 824 ~ 849 869 ~ 894
( 867 ~ 896)1
GSM900 876 ~ 915 921 ~ 960
(921 ~ 962)1
DCS1800 1710 ~1785 1805 ~ 1880
(1802 ~ 1884)
PCS1900 1850 ~1910 1930 ~ 1990
(1927 ~ 1994)1
W-CDMA/HSDPA
Frequency (MHz) Band Uplink Downlink
Band I 1920 ~ 1980 2110 ~ 2170 Band II 1850 ~ 1910 1930 ~ 1990 Band III 1710 ~ 1785 1805 ~ 1880 Band IV 1710 ~ 1770 2110 ~ 2170 Band V 824 ~ 849 869 ~ 894 Band VI 830 ~ 840 875 ~ 885 Band VIII 880 ~ 915 925 ~ 960 Band IX (Japan) 1749.9 ~ 1784.9 1844.9 ~ 1879.9
cdma2000/1xEV-DO
Frequency (MHz) Band Reverse Forward
Band 0 (Cell US) 815 ~ 849 869 ~ 894 AWS-1 1710 ~ 1755 2110 ~ 2155 Band 1 (PCS US) 1850 ~1910 1930 ~ 1990
887 ~ 889
Band 3 (Cell Japan)
Band 4 (PCS Korea) 1750 ~ 1780 1840 ~ 1870 Band 6 (IMT-2000) 1920 ~ 1980 2110 ~ 2170
893 ~ 901 915 ~ 925
GSM/GPRS/EGPRS
Peak Tx Power Measurement
Range: 20 to +39 dBm Resolution: 0.1 dB Accuracy: ±1.0 dB (25 ±5 °C), typical =
±1.5 dB (0 to 50 °C)
±
832 ~ 834 838 ~ 846 860 ~ 870
0.5
Power Ramp
Range: 20 to +39 dBm Resolution: 0.1 dB Accuracy: ±1.0 dB (25 ±5 °C), ≤ ±1.5 dB (0 to 50 °C) Range for display:
Vertical: 80 dB Horizontal: zoom off 9.25 to +156.25 bits, zoom on 8.00 to
+2.00 bits, +145.00 to +155.00 bits
Frequency Error Measurement
Range: 0 to ±60 kHz Resolution: 1 Hz Accuracy: ± (10 + reference signal) Hz Input level: 5 to +39 dBm
Burst Timing
Range: 20 to +20 deg Resolution: 0.1 deg Accuracy:
1
GSM850, GSM900: ±1.0 deg rms DCS1800, PCS1900: ±1.5 deg rms GSM850, GSM900: ±4.0 deg peak DCS1800, PCS1900: ±6.0 deg peak
Input level: 5 to +39 dBm
Rx Quality
Range: 0 to +7 Resolution: 1
Actual Timing Advance
Range: 0 to +63 bits Resolution: 1 bit
EVM Measurement (EGPRS 8PSK)
Range: 0 to 10% Resolution: 0.01% Residual EVM: 3.8% Input level: 5 to +39 dBm
Origin Offset Measurement (EGPRS 8PSK)
Range: 20 dB Resolution: 0.01 dB Residual EVM: 40 dB Input level: 5 to +39 dBm
Spectrum Monitor
Range: 11 to +39 dBm Span: fc to fc+400 kHz, fc±100 kHz RBW: 10 kHz, 30 kHz Range for display:
Span fc to fc+400 kHz ,level 80; fc±100 kHz, level 80
Accuracy: ±2 dB Resolution: 0.1 dB Noise level: 35 dB (Pin = ±29 dBm)
1
Requires N9360AU-100 hardware installed in unit
3
Loading...