4
(change from 85-132 VAC
input or 170-265 VAC input)
(settle to within ±1.0%
of the rated output, with
a resistive load)
N5741A N5742A N5743A N5744A N5745A N5746A
DC Output ratings Voltage 6 V 8 V 12.5 V 20 V 30 V 40 V
Current 100 A 90 A 60 A 38 A 25 A 19 A
Power 600 W 720 W 750 W 760 W 750 W 760 W
Output Ripple and Noise CV p-p
1
60 mV 60 mV 60 mV 60 mV 60 mV 60 mV
CV rms
2
8 mV 8 mV 8 mV 8 mV 8 mV 8 mV
Load Effect Voltage 2.6 mV 2.8 mV 3.25 mV 4 mV 5 mV 6 mV
(change from 10% to 90%)
Current 25 mA 23 mA 17 mA 12.6 mA 10 mA 8.8 mA
Source Effect Voltage 2.6 mV 2.8 mV 3.25 mV 4 mV 5 mV 6 mV
Current 12 mA 11 mA 8 mA 5.8 mA 4.5 mA 3.9 mA
Programming Accuracy Voltage 0.05%+ 3 mV 4 mV 6.25 mV 10 mV 15 mV 20 mV
Current 0.1%+ 100 mA 90 mA 60 mA 38 mA 25 mA 19 mA
Measurement Accuracy Voltage 0.1%+ 6 mV 8 mV 12.5 mV 20 mV 30 mV 40 mV
Current 0.1%+
300 mA 270 mA 180 mA 114 mA 75 mA 57 mA
Load Transient Recovery Time
3
Time ≤1.5 ms ≤1.5 ms ≤1.5 ms ≤1 ms ≤1 ms ≤1 ms
Supplemental Characteristics
Output Response Time Up, full load 0.08 s 0.08 s 0.08 s 0.08 s 0.08 s 0.08 s
Down, full load 0.05 s 0.05 s 0.05 s 0.05 s 0.08 s 0.08 s
Down, no load 0.5 s 0.6 s 0.7 s 0.8 s 0.9 s 1.0 s
Command Response Time
4
55 ms
Remote Sense Compensation
Volts/load lead 1 V 1 V 1 V 1 V 1.5 V 2 V
Over-voltage Protection Range 0.5-7.5 V 0.5-10 V 1-15 V 1-24 V 2-36 V 2-44 V
Accuracy 0.06 V 0.08 V 0.125 V 0.20 V 0.30 V 0.40 V
Output Ripple and Noise5CC rms 200 mA 180 mA 120 mA 76 mA 63 mA 48 m
Programming Resolution Voltage 0.72 mV 0.96 mV 1.5 mV 2.4 mV 3.6 mV 4.8 mV
Measurement Resolution
Current 12 mA 10.8 mA 7.2 mA 4.56 mA 3 mA 2.3 mA
Front Panel Display Accuracy
Voltage 0.03 V 0.04 V 0.06 V 0.10 V 0.15 V 0.20 V
(4 digits; ±1 count)
Current 0.50 A 0.45 A 0.30 A 0.19 A 0.13 A 0.10 A
Notes:
1
Up to 20 MHz
2
From 5 Hz – 1 MHz
3
Time for output voltage to recover within 0.5% of its rated output for a load change from
10 to 90% of its rated output current. Voltage set point from 10% to 100% of rated output
4
Add this to the output reponse time to obtain the total programming time
5
From 5 Hz – 1 MHz, at 10% to 100% of output voltage at full load
(for 6 V units from 33% to 100% of output voltage)
Supplemental characteristics are not warranted but are descriptions of typical performance determined either by design or type testing.
Performance Specifications Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 40°C.