Keysight (Agilent) E8404A Data Sheet

PDFINFO H2 87 9- 0 1
VXI Mainframe, C-Size, 13-Slot,
1000 Watt
HP E8404A
Technical Specifications
13-Slot, C-size
Enhanced monitoring for confident measurements
Color graphics display
1000 watts of usable power
Efficient, quiet cooling improves VXI module performance
Compliant with VXIbus & VXI Specifications
plug&play
Description
The HP E8404A C-size, 13-slot VXI mainframe is the high-performance mainframe in Hewlett-Packard’s new VXI mainframe family. It delivers innovative cooling technology, improved backplane design, high reliability, easy maintenance, and versatile accessories. The power supply in the HP E8404A VXI mainframe provides 1000 watts of usable power, sufficient for the most demanding automated test applications. The innovative air distribution system in this mainframe provides extremely quiet and efficient cooling.
HP E8404A
Enhanced monitoring of the HP E8404A mainframe provides superior cooling control and details regarding temperatures throughout the mainframe, power supply voltages and currents, fans operation, system status, history queue, and stripcharts or histograms for easy diagnostics. This information is available on the full color display or through VXIbus or RS-232 connection. A front panel diagnostics connector allows continuous local or remote system monitoring. This mainframe also complies with the VXI specification by providing injector surface rails used by the HP QUIC easy module insertion and extraction system. Superior cooling, reliable design and enhanced monitoring make the HP E8404A an excellent choice for all VXI test system applications.
Refer to the HP Website for instrument driver availability and downloading instructions, as well as for recent product updates, if applicable.
PDFINFO H2 87 9- 0 2
Enhanced Monitoring
VXIbus or RS-232 communication
3 temperature sensors per slot
Cooling control
Power supply voltage and current
Stripcharts and histograms for easy diagnostics
Audible warnings of over-limit conditions
History queue
VXI
plug&play
English, French, German, and Spanish language
WIN Framework driver
support
State-of-the-art enhanced monitoring is provided on the HP E8404A VXI mainframe. The enhanced monitor board plugs into the backplane from the rear of the mainframe; it does not occupy a slot in the mainframe or tie up a MODID line.
The enhanced monitoring is message based, allowing easy communication with the mainframe for the user over RS-232 or through the VXIbus. SCPI commands are used to address the mainframe. A VXI
plug&play
WIN Framework driver is provided.
Temperature monitoring includes module exhaust temperatures at three points on every slot, power supply temperature and ambient temperature. Measurements at the front, center and rear of every slot provide an accurate assessment of the temperature fluctuations over a variety of cards, whose hottest components may vary in position. Display screens are provided for overall temperature map, temperature limits set, stripcharts and histograms of each slot.
Temperature monitoring is also used for cooling control. Both the absolute temperature of the slots and the temperature rise over ambient temperature are measured. Cooling speed is increased when either an absolute temperature or a temperature rise approaches its respective limit. The user may adjust these control limit ranges programmatically.
Speeds of power supply fans and the impeller are displayed as a percentage of full speed and as the number of rotations per minute.
All seven voltages, + 5 V standby and the optional user­supplied external 5 V power are measured. Current monitoring is provided and power is calculated for each power supply voltage. Overview display screens are provided for all these data; more detailed information is also available in stripcharts and histograms. These values are visible on the display and are available through the VXI and RS-232 interfaces.
Warning alarms occur when a temperature is over limit, power supply voltages are out of VXI specification, when current or total power exceeds user set limits, or for certain user-defined conditions. A beeper provides audible warnings; it is enabled or disabled through a SCPI command or through the front panel keys.
The enhanced monitor includes a maintenance timer. This timer may be set, queried, and reset by the user for support of scheduled maintenance activities, such as cleaning the optional air filter.
The enhanced monitor may operate independently of line power by providing external + 5 V power. When line power goes down, communication with the enhanced monitor is possible via the RS-232 interface.
Remote power-on is available via the diagnostic connector “remote on signal” or through a SCPI command.
Localization enables the user to select English, French, German, or Spanish languages on the display for ease of operation worldwide.
Color Graphics Display
A full color graphical display on the front of the HP E8404A VXI mainframe provides frame status, including:
Temperatures at front, center and rear of every slot
Ambient and power supply temperatures
Power supply voltages
Power supply currents
Total power
Fans speeds
User-defined text messages
System log and timer
History
1000W Power Supply
The HP E8404A VXI mainframe features over 1000 watts of usable power from 0 °C to 55 °C. Ample dynamic and peak currents are provided for most applications.
PDFINFO H2 87 9- 0 3
Superior Cooling
The innovative cooling design in the HP E8404A VXI mainframe provides extremely quiet and efficient cooling. Carefully engineered airflow provides the ultimate in cooling with a minimum of noise. Outstanding back pressure performance insures airflow through dense modules. Separate power supply cooling fan(s) provides an independent air path for reliable cooling of the power supply.
All fans operate in either Variable or Full Speed mode. A two-position switch on the mainframe’s front panel controls the speed mode. Full Speed mode is recommended for maximum cooling and/or if acoustic noise is not a concern; all air movers (cardcage impeller and power supply fan(s)) are operated at full capacity at all times. In Variable Speed mode, the fan speed will vary depending on the temperature rise in the mainframe, and the ambient temperature. Variable Speed mode operation allows the quietest operation while providing sufficient cooling for the modules in the mainframe.
Airflow is conveniently routed into the rear and exhausted out the sides of the mainframe. This allows mainframes to be stacked or rack-mounted directly on top of one another.
At-a-Glance Confidence in Operation
The front panel indicator lights on the HP E8404A VXI mainframe gives immediate visual indication that the power supply voltages are operating within the VXI Specification, the temperatures are within limit, and that the fans are operational. Backplane activity and SYSFAIL indicators are also provided.
The system can be reset easily from the front panel, providing reset even when the Slot 0 is inaccessible due to cabling.
The diagnostic connector, conveniently located on the front of the mainframe, provides connection for remote monitoring of power supply voltages, power supply and reference temperatures, and fans function. This connector also allows remote on/standby, access to +5VSTDBY, ACFAIL, and SYSRESET. The connector’s functionality is a superset of the functionality on the HP E1401B Mainframe, allowing software and hardware compatibility with existing applications. Up to 1A of +5VSTDBY may be provided by the user through the connector. Up to 1 A each of + 5 V and + 12 V are available for external applications through the connector.
Improved, Highly Reliable Backplane Design
The backplane features solid state automatic daisy­chain jumpering for the VMEbus grant and interrupt acknowledge lines, eliminating the need for hand selection of switch settings. Full differential distribution of the CLK10 signal is provided on the backplane. This minimizes jitter and skew, providing a clean timing source for VXI instrument modules. The surface mount backplane improves both reliability and stripline signal performance.
HP generates SYSRESET and ACFAIL on the backplane. This is necessary for full compliance with the VXI Specification, but is not generally implemented by other manufacturers.
Easy Maintenance Rear-Accessible Power Supply and Impeller
Convenient access to the power supply, cooling and monitoring systems is provided through the mainframe’s rear panel; a replacement power supply or fan can be installed without removing the mainframe from a rack. The power supply’s plug-in design makes repairing easy.
The monitor control board and the impeller for module cooling are easily replaced. The internal fan for the power supply, an integral part of the supply, is easily replaced with the power supply itself. If the optional Air Filter Accessory Kit is installed, air filters may be replaced without tools.
Accessories and Configurations
Optional Rack Mounting Kits
Three rack mounting kits are available for the mainframe, providing versatile options for installation in an HP or a non-HP rack. The following rack mounting kits are available: Standard Adapter Kit, Flush Mount Adapter Kit and VXI
plug&play
Adapter Kit.
Standard Adapter Kit for Recess, Flush or Forward Rack Mounting
Using the Standard Adapter Kit (HP E8394A), the mainframe can be recess mounted up to 10.6 inches in
1/2 inch increments. (Recess mounting is required for
compatibility with the tinted acrylic door.) The mainframe can also be mounted extended from the
front of the rack from 0 to 5.8 inches in 1/2 inch
increments, allowing mounting in racks with shallow depths. The Standard Adapter Kit includes handles and requires the HP E3664A Support Rail Kit or the HP 1494-0411 Rack Slide Kit.
Compliant
Loading...
+ 6 hidden pages