Agilent E5061B Confi guration Guide

Agilent E5061B Network Analyzer
Confi guration Guide
Ordering guide
The following steps will guide you through configuring your E5061B.
Standard furnished item
Description Additional information
Installation guide Contains the information necessary to start up with the E5061B.
Power cable
Certifi cate of calibration
Note: Keyboard and mouse are not furnished as standard. Refer to “Step 5. Accessory option” for the selection of these items.
Step 1. Choose test set option (mandatory)
Description Option No. Requires Not compatible Additional information
LF-RF network analyzer with DC bias source, 5 Hz to 3 GHz
E5061B-3L5 None None This option has the following features.
- S-parameter test port (5 Hz to 3 GHz)
- Gain-phase test port (5 Hz to 30 MHz)
- Built-in DC bias source
Note: The E5061B-3L5 is the only one test set option as of Sep. 2009.
Step 2. Choose hardware option (If not required, go to step 3)
Description Option No. Requires Not compatible Additional information
High stability timebase E5061B-1E5 None None This option improves the frequency accuracy
and stability of the E5061B.
Note: Refer to “Hardware upgrade” section for retrofit information on the above options.
Step 3. Choose hard disk drive option (mandatory)
Description Option No. Requires Not compatible Additional information
Standard hard disk drive E5061B-019 None None
Note: The E5061B-019 is the only one hard disk drive option. Removable hard disk drive is not provided for the E5061B.
Step 4. Choose software option (If not required, go to step 5)
Description Option No. Requires Not compatible Additional information
Time domain/fault location analysis
E5061B-010 None None Adds time domain and fault location analysis
function.
Note: Refer to “Software upgrade” section for retrofit information on the above options.
2
Step 5. Choose accessory option (If not required, go to step 6)
Description Option No. Requires Not compatible Additional information
Add keyboard E5061B-810 None None Adds a keyboard.
Add mouse E5061B-820 None None Adds a mouse.
Rack mount Kit E5061B-1CM None E5061B-1CP Adds a rack mount kit.
Front Handle Kit E5061B-1CN None E5061B-1CP Adds a front handle kit.
Rack mount and front handle kit
E5061B-1CP None E5061B-1CM
E5061B-1CN
Adds a rack mount kit and a front handle kit.
Step 6. Choose calibration option
Description Option No. Additional information
ISO 17025 compliant calibration E5061B-1A7 Certifi cate of calibration compliant with ISO 17025 and test data is supplied.
ANSI Z540 compliant calibration
E5061B-A6J Certifi cate of calibration compliant with ANSI Z540 and test data is supplied.
E5061B with mouse and keyboard
3
Test accessories and calibration kits
Test accessories and calibration kits that can be used with the E5061B are listed in this section. A complete line of test accessories and calibration kits can be found at the Agilent RF and Microwave Test Accessories Web site:
www.agilent.com/find/accessories
Test accessories
Test accessories such as test port cable are necessary for a complete measurement system using the E5061B. Order test accessories in accordance with the desired measurement system.
Calibration kits
Calibration is an accuracy enhancement procedure that effectively reduces the system errors that cause uncertainty in network measurement. Calibration kit is necessary to perform the calibration.
• Mechanical calibration kits include standards, such as opens, shorts and loads, which are measured by the network analyzer. Choose a calibration kit for each connector type to be used.
• Electronic calibration (ECal) modules1 replace mechanical calibration standards with one solid-state calibration module
that is controlled by the network analyzer via USB. ECal modules provide many different impedances to the test ports which enables a full two-port calibration to be performed quickly with a single connection. This technique reduces operator errors and connector wear and abrasion.
Mechanical calibration kits
1. ECal modules don’t cover the whole frequency range of the E5061B.
Check whether the frequency range of each ECal module meets your measurement needs.
Electronic calibration (ECal) modules
4
Test accessories (for 50 Ω devices)
Description Model No. Requires Additional information
Test Port Cable N6314A None 50 Ω type-N (m) to type-N (m) cable, DC to 12.4 GHz, 61 cm (24 in)
Test Port Cable N6315A None 50 Ω type-N (m) to type-N (f) cable, DC to 12.4 GHz, 61 cm (24 in)
Test Port Cable 11500E None 3.5 mm (m) to 3.5 mm (m) cable, 61 cm (24 in)
Test Port Cable 11500F None 3.5 mm (m) to 3.5 mm (m) cable, 150 cm (24 in)
Test Port Cable 11857D None 50 Ω 7 mm to 7 mm cable, 300 kHz to 6 GHz, 61 cm (24 in)
Test Port Cable 8120-1838 None 50 Ω BNC (m) to BNC (m) cable, 30 cm (12 in)
Test Port Cable 8120-1839 None 50 Ω BNC (m) to BNC (m) cable, 61 cm (24 in)
Adapter 1250-0780 None 50 Ω type-N (m) to 50 Ω BNC (f) adapter
Adapter 1250-1200 None 50 Ω BNC (f) to SMA (m) adapter
Adapter 1250-2015 None 50 Ω BNC (m) to SMA (f) adapter
N6314A
11500F
11857D
N6315A
11500E
8120-1838
1250-1200
8120-1839
1250-0780
5
1250-2015