Keysight (Agilent) E3610A Service Note

E3610A-04
SERVICE NOTE
SUPERSEDES: NONE
E3610A 30W Lab Bench DC Power Supply
Serial Numbers: KR41807594/KR64315031
To eliminate the oscillation from the power supply's output.
To be performed by: Agilent-Qualified Personnel
Duplicate Ser vice Not e s : E3611A-05
Situation:
Solution / Action:
Remove the C4 and C5 capacitors on the main PC board.