E1693A-01
SUPERSEDES: None
DATE: October 1995
Broadband Series and Series 90 155/622 Mb/s ATM
Analyzer Modules
Serial Numbers: AU00000000 / AU99999999
Spurious Cell Loss Errors
Duplicate Service Notes: E1693A-01, E1694A-01
To Be Performed By: Agilent-Qualified Personnel
Parts Required:
E1694-69001 Exchange E1694A 155/622 MB/s ATM Analyzer Module
Situation:
Symptoms of spurious bit errors and cell loss may occur if units with rev A01.00 (Series
90) or rev A.02.00 (Broadband Series) firmware are upgraded to rev A02.01 firmware.
Solution/Action:
Replace both E1693A and E1694A modules with exchange unit part numbers E169369001 and E1694-69001.
Procedure:
If the symptoms described occur:
1. Replace the E1693A and E1694A with exchange units.
2. Carry out performance test.
1 of 1
AUTHOR: DH
ENTITY: Y900
© 1995 AGILENT TECHNOLOGIES
PRINTED IN U.S.A.
SERVICE NOTE
ADMINISTRATIVE INFORMATION
MODIFICATION RECOMMENDED
SERVICE NOTE CLASSIFICATION:
ACTION
CATEGORY:
LOCATION
CATEGORY:
CUSTOMER INSTALLABLE
ON-SITE
SERVICE CENTER
AGILENT RESPONSIBLE UNTIL: October 1997
ADDITIONAL INFORMATION:
IMMEDIATELY
ON SPECIFIED FAILURE
AGREEABLE TIME
AVAILABILITY:
PRODUCT’S SUPPORT LIFE
RETURN
SCRAP
SEE TEXT
SERVICE
INVENTORY:
RETURN
SCRAP
SEE TEXT
USED
PARTS:
STANDARDS:
Labor 1.0 Hours