Six 1x4, 50 RF Multiplexer
Agilent E1472A
1-Slot, C-size, register based
Six 1x4 multiplexers
Switch signals up to 1.3 GHz
Controls E1473A/E1475A RF expanders
Tree-switching for high isolation, low VSWR
Agilent E1472A
Description
The Agilent E1472A 50 RF Multiplexer is a C-size, 1-slot, register-based VXI module. It is the ideal choice to route
test signals from your application to your test instruments (i.e., oscilloscope and spectrum, network, distortion analyzers, or other RF equipment). The E1472A is functionally identical to the E1474A except for output impedance.
The RF multiplexer can be used as six multiplexers or combined with others to form a larger tree-switched multiplexer or a limited stubless matrix. You can easily and inexpensively expand the E1472A via the E1473A 50RF multiplexer expander or via the E1475A 75RF multiplexer expander.
The E1472A can easily be programmed with SCPI commands to scan multiple channels, where each channel is switched to its common, one at a time. This module is arranged as six independent banks of channels (Bank 0 through Bank 5), each acting as a 1x4 one-wire multiplexer. Only one channel in each bank can be connected to its common at any time. The multiplexer relays are arranged in a tree-switched configuration, providing high isolation and low VSWR. Each channel consists of a nonlatching armature relay.
Refer to the Agilent Technologies Website for instrument driver availability and downloading instructions, as well as for recent product updates, if applicable.
Agilent Technologies
PDFINFO H 5 6 1 1 - 0 2
2
Cables and Connectors
Various 50 cables are available from Agilent for connecting to the SMB connectors on the front panel of the multiplexer. Adapters and other connectors are also available. Connectors are also available from Johnson Components. Johnson Components:
U.S.A. Tel.: 1-800-247-8256 Outside U.S.A. Tel.: (507) 835-6222
Fax.: (507) 835-8356
Product Specifications
Input
Maximum voltage (center or shield-to-center, shield or chassis): 42 V Maximum current (per channel or common):
DC: 1 A AC rms: 1 A
Maximum power (per channel or common):
DC: 24 W AC: 24 VA
DC
Maximum thermal offset: 6 µV Closed channel resistance (typical): <1 initial Insulation resistance (between any two terminals): >10E8 Ω≤40 °C, 65% RH
AC
Note: For AC performance, ZL=ZS=ZO, 40 °C, RH 95% for C-size, RH 65% for B-size
Characteristic impedance (Zo):
50
Insertion loss:
<10 MHz: <0.1 dB <100 MHz: <0.4 dB <500 MHz: <0.9 dB <1.3 GHz: <1.5 dB <3 GHz (typ): <8.0 dB
Crosstalk (channel-to-channel):
<10 MHz: <–90 dB <100 MHz: <–80 dB
Crosstalk (channel-to-channel, one channel closed or channel-to­common) (terminated):
<200 MHz: n/a <500 MHz: <–62 dB <1.3 GHz: <–50 dB <3 GHz (typ): n/a
VSWR:
<10 MHz: <1.05 <100 MHz: <1.15 <200 MHz: n/a <500 MHz: <1.35 <1.3 GHz: <1.5 <3 GHz: n/a
Risetime: <300 ps Signal delay: <3 ns Capacitance:
Center-shield: n/a Chassis-shield: n/a
General Characteristics
Relays: Non-latching armature Power up/down state: All open Minimum relay life:
No load: 5x10E6 operations Rated load: 10E5 operations
General Specifications
VXI Characteristics
VXI device type: Register based, A16, slave only Size: C Slots: 1 Connectors: P1/2 Shared memory: None VXI busses: None C-size compatibility: n/a
Configuration
Each channel consists of a non-latching armature relay. At power-on or reset, channels 00, 10, ... 50 are connected to COM 00, 10, ... 50, respectively, and all other channels are open (unterminated). The RF multiplexer can be used as six multiplexers or combined with others to form a larger tree-switched multiplexer or a limited stubless matrix as shown in the accompanying diagram.
To expand the E1472A refer to the E1473A 50RF multiplexer expander or the E1475A 75RF multiplexer expander. The E1472A can control other external relays requiring 5V, 12V, or 24V drive.