Keysight (Agilent) 8642A Data Sheet

8642A Synthesized Signal Generator, 100 kHz to 1050 MHz (Discontinued – Support Information Only)
Data Sheet
Frequency Specifications
Range: 100 kHz to 1057.5 MHz Bands: The full range is covered in one continuous span. However, many specifications are dependent on carrier
132.1875 5 33.046876 to 66.09375 4 16.523438 to 33.046875 3 8.261719 to 16.523437 2 4.130860 to 8.261718 1 0.1 to
4.130859 HET 0.1 to 132.1875 Sweep Modes: Start-stop, span, and phase continuous X-Axis Output: 0 to 10 Vdc, ±10% Y-Axis Output: TTL positive true for display blanking during retrace
Resolution: 1 Hz, 0.1 Hz with special function Stability Standard: Aging rate: ±2 ppm/year Option 001: <10e-9/day aging rate after 8 days warmup Spectral Purity
Specifications Residual FM (in CW, AM or Angle Mo dulation <1/3 max dev.) 500 MHz: <1.2 Hz (0.3 to 3 kHz BW), <2 Hz (0.05 to 15 kHz BW) 1000 MHz: <2 Hz (0.3 to 3 kHz BW), <5 Hz (0.05 to 15 kHz BW) SSB Phase Noise at 20 kHz Offset (CW, AM or FM/PhiM <1/60 max dev) 125 MHz: -144 dBc/Hz 200 MHz: -141 dBc/Hz 500 MHz: -137 dBc/Hz 1000 MHz: -134 dBc/Hz
Residual AM: <0.01% AM rms, 0.3 to 3 kHz BW Spurious Harmonics: -30 dBc at <= +10 dBm Subharmonics: None, fc <=1057.5 MHz Nonharmonics (>10 kHz
offsets): -100 dBc Third Order Intermodulatio n: < -50 dBc at +10 dBm, 2 generators 25 kHz apart into a resistive combiner. Typically decreases 10 dB for every 5 dB of combined level decrease. Output Specifications Level Range: From maximum available to -140 dBm (0.023 µV) Maximum Level Available bands 1 thru 7: +20 dBm (2.24 V) bands 8 and HET: +18 dBm (1.78 V) band 9: +16 dBm (1.41 V)
Resolution: 0.01 dB Absolute Accuracy: ±1 dB, output level >= -127 dBm Flatness: <= ±0.75 dB, +10 dBm output level Impedance: 50 ohm nominal SWR: <1.5:1, level<0 dBm; <2.0:1, level >=0 dBm Reverse Power Protection: 50W, from a 50 ohm source 25 Vdc Modulation Specifications
Amplitude Modulation AM Depth: 0 to 99.9%, output level <= +10 dBm AM Resolution: 0.1% AM Indicator Accuracy at 1 kHz Rate and Up to 90% AM: ±(3.5% of setting + 1% AM), fc <=528.75 MHz ±(5% of setting + 1% AM), fc >528.75 MHz AM Distortion at 1 kHz Rate: Depth Distortion fc <=528.75 MHz fc >528.75 MHz 0 to 30% AM <1% <2% 30 to 70% AM <2% <4% 70 to 90% AM <4% <6% AM 3 dB Bandwidth, Depth <=90% External DC/AC Coupling:dc/20 Hz to 100 kHz, fc: 01 to 4.13 MHz, 33.04 to 2115 MHz, HET; dc/20 Hz to 20 kHz, fc: 4.13 to
33.04 MHz Internal: Same as external AC Incidental PhiM at 1 kHz Rate and 30% AM: <0.2 radians peak Frequency Modulation Ma ximum FM Deviation: Car rier Maximum deviation Maximum deviation frequency dc­coupled ac-coupled or internal band (the smaller of) 9 1.5 MHz 1.5 MHz or f mod X 1080 8 750 MHz 750 kHz or f mod X 540 7 375 kHz 375 kHz or f mod X 270 6 187 kHz 187 kHz or f mod X 135 5 93.8 kHz 93.8 kHz or f mod X
67.5 4 46.9 kHz 46.9 kHz or f mod X 33.75 3 23.4 kHz 23.4 kHz or f mod X 16.88 2 11.7 kHz 11.7 kHz or f mod X
8.44 1 93.8 kHz 93.8 kHz or f mod X 67.5 HET 1.5 MHz 1.5 MHz or f mod X 1080 FM Resolution: 0.7% of setting or
0.0004% of maximum deviation, whichever is larger FM Indicator Accuracy, Rates <= 100 kHz:±(5% of setting + 10 Hz) FM Distortion, Rates 20 Hz to 100 kHz: 4% for max. dev., 2% for 1/2 max. dev., 0.4% for 1/15 maximum dc­coupled deviation FM 3 dB Bandwidth (dc/ac coupling): dc/20 Hz to 200 kHz (external) Incidental AM: 0.3%, 20 kHz peak dev., 1 kHz rate, fc >400 kHz
Phase Modulation
Maximum Phase Deviation: Carrier frequency band Maximum deviation (radians) 9 100 8 50 7 25 6 12.5 5 6.25 4 3.13 3 1.56 2 0.78 1 6.25 HET 100 PhiM Accuracy: ±(5% of setting + 0.09 radians), 1 kHz rate Phi Resolution: greater of
0.7% of setting or 0.0004% of maximum deviation PhiM Distortion: <0.4%, 1 kHz rate PhiM 3 dB Bandwidth: DC/20 Hz to 15 kHz Pulse Modulation (for output levels <= +15 dBm) Pulse On/Off Ratio: >40 dB; >80 dB, fc >1057.5 MHz Rise/Fall Time: <400 ns, 10 % to 90% Maximum Repetition Frequency: 100 kHz Minimum Pulse Width: 2 µs Internal Modulation Oscillator Rates: 20 Hz to 100 kHz Frequency Resolution: 1% of setting Accuracy: 2% ofsetting Output Level Range: 0 to 3 V peak into 600 ohns Resolution: 4 mV Accuracy: ±(4% + 15 mV) within 1 second Distortion: <0.02%, 0.02 kHz to 15.8 kHz; <0.15%, >15.8 kHz Output Impedance: 600 ohms ±10% Remote Programming Specifications
Interface: HP-IB (IEEE-488-1978) HP-IB Functions: Listener, talker, and controller. SH1, AH1, T5, TE0, L3, LE0, SR1, RL1, PP1, DC1, DT1, C1, C3,
C28, E2 General Specifications
Operating Temperature Range: 0° to 55°C Storage Temperature Range: -55° to +75°C Leakage:Conducted and radiated interference is within the requirments of MIL-STD-461V method RE02. Interference
is also within the standards set by FTZ-1046. Also, RF leakage of <0.5 µV is induced in a 2 turn loop 2.5 cm in diameter, held 2.5 cm away from any surface for ouptut levels <=0 dBm. Power Requirements: 100, 120, 220, or 240 V; +5%, -10%; 48 to 440 Hz; 300 VA max Size: 425 mm W x 133 mm H x 617 mm D (16.75 in x 5.25 in x 24.3 in)
Agilent System II Module Size: 1 W x 5 1/4 H x 23 D Weight: Net, 32.7 kg (71.5 lb); Shipping, 43 kg (95 lb)
Loading...