Keysight (Agilent) 85107B Installation Manual

E7345A and E7355A Performance Upgrade Kits for the 85107B Network Analyzer

Installation Manual
Agilent Part Number: E7350-90003 Printed in USA Print Date: J une 2001 Supersedes: March 1998

Notice

The information contained in this document is subject to change without notice.
Agilent Technologies makes no warranty of any kind with regard to this material, including, but not limited to, the implied warran ties of merchantability and fitness for a particular purpose. Agilent Technologies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
Agilent Technologies assumes no responsibility for the use or reliability of its software on equipment that is not furnished by A gilent Technologies.
This document contains proprietary information which is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated to another language without prior written consent of Agilent Technologies.
Restricted Rights Legend
Use, duplication, or disclosure by the U.S. Government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013 for DOD agencies, and subparagraphs (c)(1) and (c)(2) of the Commercial Computer Software Restricted Rights clause at FAR 52.227-19 for other agencies.
Agilent Technologies Santa Rosa Systems Division 1400 Fountaingrove Parkway Santa Rosa, CA 95403-1799, U.S.A.
© Copyright 1998, 2001 Agilent Technologies, Inc
Read Me First!
Using this document and an E7345A or E7355A upgrade package, an Agilent service engineer can upgrade an 85107B network analyzer to full 8510XF capability, in either 85 GHz or 110 GHz.
Agilent Technologies does not recommend customer installation of the upgrade packages.
Scheduling Installation The E7345A or E7355A performance upgrade packages come with prepaid
installation. Please call your local Agilent office to arrange for a service engineer to install the upgrade kit (see “Contacting Agilent” on pagevi).
E7345A/E7355A - Installation Manualiii

Warranty

Certification
Agilent Technologies certifies that this product met its published specifications at the time of shipment from the factory. Agilent Technologies further certifies that its calibration measurements are traceable to the United States National Institute of Standards and Technology (NIST, formerly
NBS), to the extent allowed by the Institute’s calibration facility, and to the calibration facilities of other International Standards Organization members.
Warranty This Agilent Technologies system product is warranted against defects in
materials and workmanship for a period corresponding to the individual warranty periods of it s component products. Inst r uments are warranted f or a period of one year. During the warranty period, Agilent Technologies will, at its option, either repair or replace products that prove to be defective.
Warranty service for products installed by and certain other products
designated by Agilent will be performed at Buyer’s facility at no charge within service travel areas. Outside Agilent service travel areas, warranty service will be performed at Buyer’s facility only upon Agilent Technologies’s prior agreement and Buyer shall pay Agilent’s round trip travel expenses. In all other areas, products must be returned to a service facility designated by Agilent Technologies.
For products returned to Agilent for warranty serv ice, Buyer s hall prepay shipping char ges to Agilent and Agilen t sh al l pay shipping char ge s t o return the product to Buyer. However, Buyer shall pay all shipping charges, dutie s, and taxes for products returned to Agilent from another country.
Agilent war rants that its software and firmware desig nated by Agilen t for use with an instrument will execute its programming instructions when properly installed on that instrument. Agilent does not warrant that the operation of the instrument , or software , or fir mware will be uni nterrupted or error free.
LIMITATION OF WARRANTY. The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by Buyer, Buyer-supplied software or interfacing, unauthorized modification or misuse, operation outside of the environmental specifications for the product, or improper site preparation or maintenance.
NO OTHER WARRANTY IS EXPRESSED OR IMPLIED. AGILENT TECHNOLOGIES SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OR MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
iv E7345A/E7355A - Installation Manual
EXCLUSIVE REMEDIES. THE REMEDIES PROVIDED HEREIN ARE
BUYER’S SOLE AND EXCLUSIVE REMEDIES. AGILENT TECHNOLOGIES SHALL NOT BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, WHETHER BASED ON CONTRACT, TORT, OR ANY OTHER LEGAL THEORY.
Assistance Product maintenance agreements and other customer assistance agreements
are available for Agilent Technologies products. For assistance, call your local Agilent Technologies office (refer to
Contacting Agilent” on pagevi).
E7345A/E7355A - Installation Manualv

Contacting Agilent

Online assistance: www.agilent.com/find/assist United States
(tel) 1 800 452 4844
New Zealand
(tel) 0 800 738 378 (fax) (+64) 4 495 8950
Malaysia
(tel) 1 800 828 848 (fax) 1 800 801 664
Taiwan
(tel) 0800-047-866 (fax) (886) 2 25456723
Latin America
(tel) (305) 269 7500 (fax) (305) 269 7599
Japan
(tel) (+81) 426 56 7832 (fax) (+81) 426 56 7840
Philippines
(tel) (632) 8426802
PLDT subscriber only):
(tel) (
1 800 16510170
(fax) (632) 8426809 (fax) (PLDT subscriber only):
1 800 16510288
People’s Republic of China
(tel) (preferred): 800-810-0189 (tel) (alternate): 10800-650-0021 (fax) 10800-650-0121
Canada
(tel) 1 877 894 4414 (fax) (905) 282-6495
Australia
(tel) 1 800 629 485 (fax) (+61) 3 9210 5947
Thailand
(tel) outside Bangkok:
(088) 226 008
(tel) within Bangkok:
(662) 661 3999 (fax) (66) 1 661 3714
India
(tel) 1-600-11-2929 (fax) 000-800-650-1101
Europe
(tel) (+31) 20 547 2323 (fax) (+31) 20 547 2390
Singapore
(tel) 1 800 375 8100 (fax) (65) 836 0252
Hong Kong
(tel) 800 930 871 (fax) (852) 2506 9233
vi E7345A/E7355A - Installation Manual

Safety and Regulatory Information

Review this product and related documentation to familiarize yourself with safety markings and instructions before you operate the instrument. This product has been designed and tested in accordance with international standards.
WARNING The WARNING notice denotes a hazard. It calls attention to a
procedure, practice, or the like, that, if not correctly performed or adhered to, could result in personal injury. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met.
CAUTION The CAUTION notice denotes a hazard. It calls attention to an operating
procedure, practic e, o r the like, which, i f not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met.
Instrument Markings
When you s ee th is s ym bol o n your instrument, you should refer to the
!
instrument’s instruction manual for important informa tion.
This symbol indicates hazardous voltages.
The laser radiation symbol is marked on products that have a laser output.
This symbol indicates that the instrument requires alternating current (ac) input.
The C-Tick mark is a registered trademark of the Australian Spectrum Agency.
The CE mark is a registered trademark of the European Community. If it is accompanied by a year, it indicates the year the design was proven.
The CSA mark is a registered trademark of the Canadian Standards Association.
E7345A/E7355A - Installation Manual vii
1SM1-A This text indicates that the instrument is an Industrial Scientific and
Medical Group 1 Class A product (CISPER 11, Clause 4). This symbol indicates that the power line switch is ON.
This symbol indicates that the power line switch is OFF or in STANDBY position.
Safety Earth Ground
Before Applying Power
This is a Safety Class I product (provided with a protective earthing terminal). An uninterrupt i ble saf ety eart h gr ound must be pr ovided from the main power source to the product input wiring terminals, power cord, or supplied power cord set. Whenever it is likely that the protection has been impaired, the product must be made inoperative and secured against any unintended operation.
Verify that the product is configured to match the available main power source as described in the input power configuration instructions in this manual. If this product is to be powered by autotransformer, make sure the common terminal i s connect ed to t he neut ral (gr ounded) s ide of t he ac po wer supply .
viii E7345A/E7355A - Installation Manual

Typeface Conventions

Italics
Used to emphasize important information:
only
Use this software
with the xxxxxX system.
Used for the title of a publication:
Refer to the
xxxxxX System-Level User’s Guide
.
Used to indicate a variable:
LOAD BIN
Type
Instrument Display Used to show on-screen prompts and messages that you will see on the
display of an instrument:
The xxxxxX will display the message
[Keycap] Used for labeled keys on the front panel of an instrument or on a
computer keyboard:
[Return].
Press
{Softkey} Used for simulate d keys that appear on an instrum ent display:
{Prior Menu}.
Press
User Entry Used to indicate text that you will enter using the computer keyboard;
text shown in this typeface must be typed
LOAD PARMFILE
Type
filename
.
CAL1 SAVED.
exactly
as printed:
Used for examples of programming code:
#endif // ifndef NO_CLASS
Path Name
Computer Display Used to show messages, prompts, and window labels that appear on a
Used for a subdirectory name or file path:
Edit the file
computer monitor:
Edit Parameters window will appear on the screen.
The
usr/local/bin/sample.txt
Used for menus, lists, di alog boxes, and button boxes on a computer
monitor from which you make selections using the mouse or keyboard:
Double-click
EXIT to quit the program.
E7345A/E7355A - Installation Manual ix

Introduction

Contents: “Scheduling Installation” on page2
“System Configurations” on page3
“Overview of the Upgrade Packages” on page5
“Installation Procedure Outline” on page6
“Step 1. Secure Static Safe Work Station” on page8
“Step 2. Verify Upgrade Package Contents” on page9
“Step 3. Secure Additional Installation Equipment” on page11
“Step 4. Check the 85107B System Operation and Memory” on page12
“Step 5. Install Non-Volatile Memory Upgrade (if needed)” on page14
“Step 6. Disconnect Unneeded Equipment” on page17
“Step 7. Install the Millimeter Wave Controller” on page18
“Step 8. Install the 83621B RF Source” on page19
“Step 10. Reconnect the System” on page21
“Step 11. Load 8510XF Operating System (Firmware)” on page23
“Step 12. Perform the 8510XF Performance Verification” on page24
NOTE The 8510C works with all 8360 synthesized sweeper models. To take
advantage of two 8510C system features (quick step and test port power flatness correction), however, some 8360 instruments must be upgraded.
NOTE This chapter covers both the CRT and LCD displays. Some display-related
adjustments apply only to instruments with a CRT display.
E7345A/E7355A - Installation Manual1
Loading...
+ 23 hidden pages