Keysight (Agilent) 85031B Network Analyzer Accessories

Network Analyzer Accessories
Overview
Accessories for the HP 8753D, 8720D, and the 8510C series network analyzers include a variety of calibration kits, verification kits, cables, and adapters from dc to 110 GHz.
Error-correction procedures require that the systematic errors in the measurement system be characterized by measuring known devices (stan­dards) on the system over the frequency range of interest. HP offers two types of calibration kits: mechanical and electronic.
Electronic Calibration (ECal) Kits
ECal kits consist of connector specific modules, adapters for test ports and a torque wrench for proper connection.
75
Mechanical Calibration Kits
All network analyzer mechanical calibration kits contain precision standard devices to characterize the systematic errors of the HP 8753 series, 8720 series or 8510C network analyzer system. Each mechanical calibration kit also contains adapters for test ports and a torque wrench for proper connection.
Verification Kits
Measuring known devices, other than the calibra­tion standards, is a straightforward way of verifying that the network analyzer system is operating properly. HP offers verification kits that include precision airlines, mismatch airlines, and precision fixed attenuators. Traceable measurement data is shipped with each kit on disk. Verification kits may be recertified by Hewlett-Packard. This recertification includes a new measurement of all standards and new data with uncertainties.
11
76
Network Analyzer Accessories
Electronic Calibration Kits
1
Frequency
HP Model Connector Range (GHz) Description 85060A 7 mm 1 to 18 One two-port ECal
module and collet remover
Option 001 7 mm 0.045 to 2 Adds lowband
ECal module
85062A 3.5 mm (m-f) 1 to 26.5 One two-por t
ECal module and m-m and f-f adapters
Option 001 3.5 mm (m-f) 0.045 to 2 Adds lowband
ECal module
Option 00F 3.5 mm (f-f) Changes
connectors to f-f
Option 00M 3.5 mm (m-m) Changes
connectors to m-m
85064A Type-N (m-f) 1 to 18 One two-port
ECal module
Option 001 Type-N (m-f) 0.045 to 2 Adds lowband
ECal module
Option 00F Type-N (f-f) Changes
connectors to f-f
Option 00M Type-N (m-m) Changes
connectors to m-m
1
Must have an HP 85060C control unit to perform electronic calibration.
Mechanical Calibration Kits
2,3,4,5
Frequency
HP Model Connector Range (GHz) Type 85036B Type-N (75 Ω) DC to 6 Economy
85039A Type-F (75 Ω) DC to 3 Economy 85031B 7 mm DC to 6 Economy 85050B 7 mm 0.045 to 18 Standard 85050C 7 mm 0.045 to 18 Precision 85050D 7 mm 0.045 to 18 Economy 85033D 3.5 mm DC to 6 Economy 85052B 3.5 mm 0.045 to 26.5 Standard 85052C 3.5 mm 0.045 to 26.5 Precision 85052D 3.5 mm 0.045 to 26.5 Economy 85032B Type-N DC to 6 Economy 85054B Type-N 0.045 to 18 Standard 85054D Type-N 0.045 to 18 Economy 85056A 2.4 mm 0.045 to 50 Standard 85056D 2.4 mm 0.045 to 50 Economy
6
85056K
2.92 mm 0.045 to 50 Economy
85058D 1.85 mm 0.045 to 65 Standard X11644A WR-90 8.2 to 12.4 Precision P11644A WR-62 12.4 to 18 Precision K11644A WR-42 18 to 26.5 Precision R11644A WR-28 26.5 to 40 Precision Q11644A WR-22 33 to 50 Precision U11644A WR-19 40 to 60 Precision V11644A WR-15 50 to 75 Precision W11644A WR-10 75 to 110 Precision
2
Unless stated otherwise, all calibration kits are 50 ohms.
3
Economy calibration kits contain fixed loads.
4
Standard calibration kits contain sliding loads.
5
Precision calibration kits contain TRL calibration standards.
6
Option 001 adds a sliding load.
Verification Kits
Verification Kit 85029B 85051B 85053B 85055A 85057B R11645A Q11645A U11645A V11645A W11645A Connector Type 7 mm 7 mm 3.5 mm Type-N 2.4 mm WR-28 WR-22 WR-19 WR-15 WR-10 Frequency Range DC to 6 0.045 0.045 0.045 0.045 26.5 to 40 33 to 50 40 to 60 50 (GHz) to 18 to 26.5 to 18 to 50
to
75 75 to 110
Loading...
+ 2 hidden pages