Keysight (Agilent) 8490D Technical Data

The HP 1670-Series
This literature was published years prior to the establishment of Agilent Technologies as a company independent from Hewlett-Packard and describes products or services now available through Agilent. It may also refer to products/services no longer supported by Agilent. We regret any inconvenience caused by obsolete information. For the latest information on Agilent’s test and measurement products go to:
www.agilent.com/find/products
Or in the US, call Agilent Technologies at 1-800-452-4844 (8am–8pm EST)
Discontinued Product—Support Information Only
Benchtop Logic Analyzers
Technical Data
Identifying the cause of problems in embedded microprocessor system designs can be difficult. The Hewlett-Packard 1670-series bench­top logic analyzers have the fea­tures to help the embedded system design team find hardware and soft­ware defects quickly .
With 64K of acquisition memory (1M optional) the HP 1670-series logic analyzers are the first bench­top logic analyzers which display processor mnemonics and verify critical hardware timing relation­ships over a long period of time.
With the standard Ethernet LAN interface, the software designer can now capture a real-time micropro­cessor trace and time-correlate it to source code in C++ or other high­level languages on a PC or worksta­tion. For time-correlation of source code, order the HP B3740A Software Analysis package.
The combination of deep memory , large internal disk drive, and LAN make the HP 1670-series of bench­top logic analyzers especially well suited to solving your integration problems.
• Mass storage is provided by an inter­nal hard drive which provides quick storage and retrieval of files.
• The 3.5-inch high-density flexible disk drive supports both DOS and LIF formats.
• The LAN interface enables access to the logic analyzer files via FTP or NFS. Use X11 windows to control or view the logic analyzer on a PC or workstation. The LAN interface includes both Ethertwist (10BASE-T) and ThinLan (10BASE 2) connectors.
• Store data as ASCII files and screen images in TIFF, PCX, and EPS (encapsulated PostScriptTM) formats.
Get to the root cause of problems quickly
• New graphical trigger macros make trigger setup easier.
• Centronics, RS-232, HP-IB and LAN communication ports make connect­ing to other devices easier than ever. All of these come standard on all models of the HP 1670-series.
• The HP 1670-series operating system includes System Performance Analysis (SPA). SPA provides state histograms, state overview , and time interval analysis.
• The HP E2450A Symbolic Download Utility is included with the HP 1670­series. This utility provides the capa­bility to extract symbolic information from popular object module formats.
PostScriptTMis a trademark of Adobe Systems Incorporated.
Logic Analyzer Key Specifications and Characteristics
_______________________________________________________________________ Model Number HP 1670D HP 1671D HP 1672D
_______________________________________________________________________ State and Timing 136 102 68 Channels
_______________________________________________________________________ Timing Analysis Conventional: 125 MHz all channels, 250 MHz half channels
_______________________________________________________________________ State Analysis 100 MHz, all channels Speed
_______________________________________________________________________ State Clocks/ 4 4 4 Qualifiers
_______________________________________________________________________ Memory Depth 64K per channel, 128K in timing half-channel mode per Channel (1M per channel optional memory ,
_______________________________________________________________________
2M in timing half-channel mode)
HP 1670-Series General-Product Information
2
_________________________ Human Interface
_________________________
Front Panel A knob and keypads
make up the front-
panel human interface. Keys include control, menu, display naviga­tion, and alpha-numer-
_________________________
Mouse A DIN mouse is shipped
_________________________
Keyboard The logic analyzer can
_________________________
ic entry functions.
as standard equipment.
It provides full instru­ment control. Knob functionality is replicat­ed by holding down the right button and moving the mouse left or right.
also be operated using
a DIN keyboard. Order the HP Logic Analyzer Keyboard Kit, model number HP E2427B.
Input/Output, Control, and Printing
_________________________
I/O Ports All units ship with a
Centronics parallel
printer port, RS-232, and HP-IB as standard
_________________________
LAN Interface An Ethernet LAN inter-
_________________________
Software The HP B3740A Soft- Analysis ware Analyzer provides Capability true source line refer-
_________________________
equipment.
face is standard with
the HP 1670-series. The LAN interface comes with both Ethertwist (10BASE-T) and ThinLan (10BASE 2) connectors.The LAN supports FTP and PC/NFS connection protocols. It also works with X11 window pack­ages.
encing and symbol download capabilities. Standard object module formats are supported.
_________________________
Program- Each instrument is fully mability programmable from a
computer via HP-IB and RS-232 connec­tions. This feature is
_________________________
HP Printer Printers which use the Support HP Printer Control
_________________________
Alternate The Epson FX80, LX80 Printer and MX80 printers Supported with an RS-232 or
_________________________
Hard Copy Screen images can be Output printed in black and
_________________________
standard on all models.
Language (PCL) and
have a parallel Centronics, RS-232 or HP-IB interface are supported: HP DeskJet, LaserJet, QuietJet, PaintJet, and ThinkJet models.
Centronics interface
supported in the Epson 8-bit graphics mode.
white from all menus using the State or timing listings can be printed in full or part (starting from center screen) using the
Print All
Print
selection.
field.
Mass Storage Files and Software
_________________________
Updating the The operating system Operating resides in Flash ROM System and can be updated
from the flexible disk drive or the hard disk
_________________________
Mass Storage Is supported by an
_________________________
drive.
internal hard disk drive
and by a 1.44 Mbyte,
3.5-inch flexible disk drive. Supports DOS and LIF formats.
A disk drive provides
quick storage and retrieval of files.
_________________________
Screen An image file of any display Image Files scre encan be stored to
disk via the display's
Print
field. Black & white TIFF, PCX, Encapsulated PostScript (EPS) , and gray-scale TIFF file for-
_________________________
ASCII Data State or timing listings Files can be stored as ASCII
_________________________
Configuration Logic analyzer files and Data Files that include configura-
_________________________
Recording of Binary format Acquisition configuration/data files are and Storage stored with the time of Times acquisition and the time of
_________________________ Acquisition Arming
_________________________
Initiation Arming is started by
_________________________
Cross Arming The analyzer machines
_________________________
Output An output signal is
_________________________
mats are available.
files on a flexible disk via the display's These files are equivalent in character width and line length to hardcopy listings printed via the
Print All
tion and data informa-
tion (if present) are encoded in a binary format. They can be stored to or loaded from the hard disk drive or a flexible disk.
storage.
Run
BNC.
can cross-arm each other.
provided at the Port Out BNC.
Print
selection.
or the Port In
field.
HP 1670-series Logic Analyzer Specifications and Characteristics
_________________________ Port In/Out
_________________________
PORT IN Port In is a standard Signal and BNC connection. Connection The input operates at
TTL logic signal levels. Rising edges are valid
_________________________
PORT OUT Port Out is a standard Signal and BNC connection with Connection TTL logic signal levels.
_________________________ Arming Times
_________________________
PORT IN 15 ns typical delay from Arms Logic signal input to a Analyzer [1]
_________________________
Logic 120 ns typical delay Analyzer from logic analyzer Arms PORT trigger to signal OUT [1] output.
_________________________ Operating Environment
_________________________
Power 115 V ac or 230 V ac, –22%
_________________________
Temperature Instrument, 0°to 50°C
_________________________
Humidity Instrument, up to 95%,
_________________________
Altitude To 3,048 m (10,000 ft)
_________________________
Vibration: Random vibrations Operating 5–500Hz,
_________________________
Vibration: Random vibrations Non Operating5–500 Hz,10 minutes per
_________________________
input signals.
A rising edge is assert­ed as a valid output.
don't
care
logic analyzer
trigger .
to +10%, single phase, 48-66 Hz, 320 VA max
(+32°to 122°F). Disk media, 10°to 40°C (+50°to 104°F). Probes and cables, 0°to 65°C (+32°to 149°F)
relative humidity at +40°C (+140°F). Disk media and hard drive, 8% to 85% relative humidity.
10 minute per axis, ~ 0.3 g (rms).
axis,~ 2.41 g (rms); and swept sine resonant search, 5–500 Hz,
0.75 g (0-peak), 5 minute resonant dwell @ 4 resonances per axis.
_________________________
Physical Factors
_________________________
Weight 28.6 lbs. (13 kg)
_________________________
Dimensions See figure 1
_________________________
Safety IEC 348/ HD 401,
UL 1244, and CSA Standard C22.2
_________________________
EMC
CISPR 11:1990/EN 55011 (1991):
Group 1 Class A
IEC 801-2:1991/EN 50082-1 (1992):
4kV CD, 8 kV AD IEC 801-3:1984/EN 50082-1 (1992):3V/m IEC 801-4:1988/EN 50082-1 (1992): 1kV
_________________________
Weight 28.6 lb. (13kg)
Figure 1Figure 1
No. 231 (series M-89)
17.3 inches (440 mm)
13.0 in. (330 mm)
8.1 in. (205 mm)
14.5 in. (367 mm)
3
_________________________ Logic Analyzer Probes
_________________________
Input 100 k±2% Resistance
_________________________
Input approx. 8 pF Capacitance (see figure 2)
_________________________
RT= 250
High Frequency Model for Probe Inputs
Figure 2
C
= 7.5 pF
COMP
RIN= 100kCTG= 1 pF Z0=
150
_________________________
Minimum 500 mV peak-to-peak Input Voltage Swing
_________________________
Minimum 250 mV or 30% of input Input amplitude, whichever is Overdrive greater
_________________________
Threshold –6.0 V to +6.0 V in 50-mV Range increments
_________________________
Threshold Threshold levels may be Setting defined for pods
(17-channel groups) on
_________________________
Threshold ±(100 mV +3% of Accuracy* threshold setting)
_________________________
Input ± 10 V about the Dynamic threshold Range
_________________________
Maximum ±40 V peak Input Voltage
_________________________
+5 V 1/3 amp maximum Accessory per pod Current
_________________________
Channel Each group of 34 Assignment channels (a pod pair)
______________________________
[1] Time may vary depending upon the
mode of logic analyzer operation.
* Warranted Specification
an individual basis
can be assigned to Analyzer 1, Analyzer 2 or remain unassigned.
Loading...