Agilent 5352B Data Sheet

Agilent 5352B 40 GHz CW Microwave Counter
Data Sheet
Input 1
Frequency Range: 500 MHz to 40 GHz (500 MHz to 46 GHz with Opt. 005)
Sensitivity Full Operating Environment 500 MHz to 26.5 GHz: -25 dBm
Maximum Input: +7 dBm
Damage Level: +25 dBm
Input 2
Frequency Range 10 Hz to 525 MHz 50 ohm: 10 MHz to 525 MHz 1 Mohm: 10 Hz to 80 MHz
Sensitivity Full operating environment 50 ohm: 10 MHz to 525 MHz, 25 mV rms (15 mV typical @ 25° C) 1 Mohm: 10 Hz to 80 MHz, 25 mV rms (15 mV typical @ 25° C)
Maximum Input 50 ohm: + 10 dBm 1 Mohm: 1V rms
Damage Level 50 ohm or 1 Mohm dc to 5 kHz: 250 V (dc + ac peak); >5 kHz: 5.5 V rms (+28 dBm) + 1.25 X 10^6 Vrms/freq
Connector: Replaceable fuse, type BNC (female)
Resolution: Selectable, 1 Hz to 1 MHz
High Resolution 1 Mohm mode, 1 second gate:
0.01 Hz for <100 kHz input
0.01 Hz for <1 MHz input
0.02 0.1 Hz for <10 MHz input
0.03 1 Hz for >10 MHz input
Timebases
Standard TCXO Aging rate: 1 X 10^-7/month Temp (0 to 50° C): 1 X 10^-6
Option 001 Aging rate: 5 X 10^-10/day Temp (0 to 50° C): 7 X 10^-9
Option 010 Aging rate: 1 X 10^-10/day Temp (0 to 50° C): 7 X 10^-9
Timebase Output 10 MHz and 1 MHz, 2.4 V square wave ac coupled into 1 kohm: 1.5V peak-to-peak into 50 ohm; rear panel BNC connectors
External Timebase 1, 2, 5, or 10 MHz, 0.7 V min. to 8 V max. peak-to-peak sine wave or square wave into >1 kohm shunted by <30 pF, via rear-panel BNC connector
General
Display: Segmented 24-character alphanumeric LCD (backlighted)
Built-in Features: Self-check, diagnostics, display and keyboard lockout, overload indicator, HP-IB teach-learn mode Data Output Over HP-IB bus; varies with frequency and resolution Auto Mode: >100 readings/s, 10 kHz resolution, no math functions, "DUMP" mode Manual mode: >120 readings/s, 10 kHz resolution, no math functions, "DUMP" mode
Math Functions: Scale, offset, smooth (exponential averaging)
Sample Rate: Variable from less than 50 ms between measurements to HOLD, which holds the display indefinitely or until trigger occurs.
Display Rate: 5/s, variable over HP-IB
Sleep Mode: Input 1 emissions reduced to <-70 dBm typical when sleep mode or Input 2 is selected.
Output
IF Output: Rear-panel BNC provides 30-110 MHz down-converted microwave signal at >-20 dBm into 50 ohm, ac­coupled.
HP-IB Interface Functions: SH1, AH1, T5, L4, SR1, RL1, PP0, DC1, DT1, C0, E1
Physical and Power Characteristics
Operating temperature: 0° C to 50° C
Power Requirements: 100 VA max
Line Select
Loading...