Keysight U1273A/
U1273AX Handheld
Digital Multimeter
Quick Start
Guide
Page 2
Contacting Keysight
CAUTION
WARNING
CAT III
1000 V
CAT IV
600 V
Safety symbols
www.keysight.com/find/assist
(worldwide contact information for
repair and service)
Safety and EMC Information
This meter is safety-certified in
compliance with EN/IEC
61010-1:2001, ANSI/UL
61010-1:2004, and CAN/
CSA-C22.2 No. 61010-1-04 for
CAT III 1000 V/CAT IV 600 V
pollution degree 2 environment.
EMC is designed in compliance
with IEC 61326-1:2005/EN
61326-1:2006. Use with standard
or compatible test probes.
Safety Notices
A CAUTION notice denotes a
hazard. It calls attention to an
operating procedure, practice, or
the like that, if not correctly
performed or adhered to, could
result in damage to the product or
loss of important data. Do not
proceed beyond a CAUTION notice
until the indicated conditions are
fully understood and met.
Earth (ground) terminal
Equipment protected
throughout by double
insulation or reinforced
insulation
Caution, risk of electric
shock
Caution, risk of danger
(refer to this manual for
specific Warning or Caution
information)
Category III 1000 V
overvoltage protection
Category IV 600 V
overvoltage protection
A WARNING notice denotes a
hazard. It calls attention to an
operating procedure, practice, or
the like that, if not correctly
performed or adhered to, could
result in personal injury or
death. Do not proceed beyond a
WARNING notice until the
indicated conditions are fully
understood and met.
For further safety information details, refer to the
Keysight U1273A/U1273AX Handheld Digital Multimeter User’s Guide.
Verify that you received the following items in the
NOTE
shipment of your multimeter:
✔One pair of red and black test leads
✔One pair of 4 mm test probes
✔One K-type thermocouple lead kit
✔Four 1.5 V AAA alkaline batteries (for U1273A)
or lithium batteries (for U1273AX)
✔Printed copies of the Certificate of Calibration
(CoC) and the U1273A/U1273AX Quick Start
Guide (this manual)
If any item is missing or damaged, keep the
shipping materials and contact the nearest
Keysight Sales Office.
The descriptions and instructions in this guide apply
to the U1273A/U1273AX handheld digital
multimeter.
All related documents and software are available for
download at www.keysight.com/find/hhTechLib.
Keysight U1273A/U1273AX Quick Start Guide5
Page 6
Install the Batteries
NOTE
Your multimeter is powered by four 1.5 V AAA
batteries (included with the shipment).
1Turn the rotary switch to OFF
and remove the test leads
from the terminals.
2Lift the tilt stand and loosen
the screws with a suitable
Phillips screwdriver.
3Remove the battery cover and observe the
polarity markings.
4Insert the batteries and replace the battery
cover and screws.
Turn On the Multimeter
To power ON your multimeter, turn the rotary
switch from the OFF position to any other
position.
Your multimeter is capable of remote data logging.
To use this feature, you will need an IR-USB cable
(U1173A, purchased separately) and the Keysight
GUI Data Logger Software (downloadable from
www.keysight.com/find/hhTechLib).
6Keysight U1273A/U1273AX Quick Start Guide
Page 7
Auto Dim
By default, the multimeter’s Auto Dim function is
enabled. The multimeter’s backlight will dim
automatically after 90 seconds of inactivity. Press
any button to cancel this effect and reset the Auto
Dim timer.
You may change how the multimeter’s backlight
behavior through the Setup menu. Refer to the
User’s Guide for further instructions.
Keysight U1273A/U1273AX Quick Start Guide7
Page 8
The Multimeter at a Glance
Display screen
Keypad
Rotary switch
Input terminals
Test lead/probe holders
IR communication port
Battery cover
Tilt stand
(Lift tilt stand for access)
8Keysight U1273A/U1273AX Quick Start Guide
Page 9
Understanding the Rotary Switch
NOTE
S
h
i
f
t
V
i
e
w
E
s
c
Z
LOW
Smart
Auto
Press to switch between the primary and
shifted functions shown on the rotary switch.
LegendDescription
Z
(low input impedance) AC/DC V for eliminating ghost
LOW
voltages
Off
AC V
AC V with Low Pass Filter
AC mV
AC mV with Low Pass Filter
DC V
AC V or AC+DC V
DC mV
AC mV or AC+DC mV
Resistance
Continuity or Smart Ω (offset compensation)
Diode
Auto-diode
Capacitance
Temperature
DC mA (or A)
AC mA (or A) or AC+DC mA (or A)
DC μA
AC μA or AC+DC μA
Keysight U1273A/U1273AX Quick Start Guide9
Page 10
Understanding the Keypad
S
c
a
l
e
N
u
l
l
P
e
a
k
M
a
x
M
i
n
A
u
t
o
T
r
i
g
H
o
l
d
Exit
Dual
Setup
H
z
%
m
s
L
o
g
A
u
t
o
R
a
n
g
e
S
h
i
f
t
V
i
e
w
E
s
c
Key response when pressed for:
Legend
Less than 1 secondMore than 1 second
Sets the Null/Relative mode.
Starts the MaxMin recording.
Freezes the present reading in
the display.
Switches between available
dual-combination displays.
Increases the OLED brightness
incrementally when LOW,
MEDIUM, or HIGH setting is
selected.
Switches between frequency,
pulse width, and duty cycle
measurements.
Sets the Scale mode for the
specified ratio and unit display.
Starts and stops the Peak
recording.
Automatically freezes the
present reading once the
reading is stable.
Exits the Hold, Null, MaxMin,
Peak, frequency test, and dual
display modes.
Enters and exits the
multimeter’s Setup menu.
Starts and stops the Data
Logging.
Sets a manual range and
disables autoranging.
Switches between the primary
and shifted functions.
10Keysight U1273A/U1273AX Quick Start Guide
Enables auto-ranging.
Enters and exits the Log
Review menu.
Page 11
Understanding the Input Terminals
WARNING
Z
LOW
Smart
Auto
or
Ensure that the terminal connections are correct for
that particular measurement function before starting
any measurement. To avoid damage to the device, do
not exceed the input limit.
Rotary positionInput terminalsOverload protection
1000 Vrms
1000 Vrms for short
circuit <0.3 A
11 A/1000 V
fast-acting fuse
440 mA/1000 V
fast-acting fuse
Keysight U1273A/U1273AX Quick Start Guide11
Page 12
Performing Measurements and Tests
Voltage measurements
The figure below highlights the primary functions
allowing voltage measurements in your
multimeter.
Set up your multimeter as shown in the figure
below to perform voltage measurements. When
measuring DC voltage from a mixed signal in DC
measurement mode, ensure that the Filter () is
enabled.
12Keysight U1273A/U1273AX Quick Start Guide
Page 13
1Press for more than 1 second to enter the
Setup
H
z
%
m
s
L
o
g
Exit
Dual
Setup
H
z
%
m
s
L
o
g
Setup
multimeter’s setup menu.
2Browse to Menu 6 > Filter, and press to
edit the value.
3Press or to enable the Filter.
Refer to the table below for the respective
firmware versions.
Version 1.64 or olderVersion 1.95 or newer
onDC
4Press to save your changes.
5Press and hold until the multimeter
restarts and returns to normal operation. Turn
the multimeter to DC Voltage mode to verify
Keysight U1273A/U1273AX Quick Start Guide13
that the LPF symbol is turned on.
Page 14
CAUTION
To avoid possible electric shock or personal injury,
S
h
i
f
t
V
i
e
w
E
s
c
Z
LOW
enable the Filter
() to verify the presence of
hazardous DC voltages. Displayed DC voltages can
be influenced by high frequency AC components
and must be filtered to assure an accurate reading.
LPF during AC measurements:
Press while performing
AC voltage measurements to
pass the measured signal
through a low pass filter.
–Passing the measured signal through a LPF
help blocks unwanted voltages such as
electronic noise.
–Use the LPF function to improve measurement
on composite sine waves that are typically
generated by inverters and variable frequency
motor drives.
Z
measurements:
LOW
Rotate the rotary switch’s
position to to enable low
impedance measurements.
–Use the Z
(low input impedance) function
LOW
to remove ghost or induced voltages from
your measurement.
–Z
can remove ghost voltages from your
LOW
measurements by dissipating the coupling
voltage. Use Z
to reduce the possibility of
LOW
false readings in areas where the presence of
ghost voltages are suspected.
14Keysight U1273A/U1273AX Quick Start Guide
Page 15
Resistance measurements
S
h
i
f
t
V
i
e
w
E
s
c
Set up your multimeter as shown in the figure
below to perform resistance measurements.
Smart Ω measurements:
While performing resistance
measurements, press
until BiAS is shown on the
secondary display to enable
the Smart Ω function.
–Use the Smart Ω (offset compensation)
function to measure resistors affected by DC
offset or leakage current.
–Smart Ω removes unexpected DC voltages
within the instrument, at the input, or at the
circuit being measured, which will add error to
Keysight U1273A/U1273AX Quick Start Guide15
Page 16
resistance measurements. Press to switch
Exit
Dual
S
h
i
f
t
V
i
e
w
E
s
c
Exit
Dual
between the bias voltage (BiAS) display or
leakage current (LEAk) display, calculated
based on the bias voltage and corrected
resistance value, on the secondary display.
Continuity tests
Set up your multimeter as shown in the figure
below to perform continuity tests. Press to
switch to the continuity test function ( is
shown on the display).
The beeper will sound as a continuity indication.
Press to switch between normal open ()
and normal close () contacts.
–Normal open: Circuit is normally open, the
beeper will sound when a short is detected.
–Normal close: Circuit is normally closed, the
beeper will sound when an open is detected.
16Keysight U1273A/U1273AX Quick Start Guide
Page 17
NOTE
The continuity function detects intermittent shorts
and opens lasting as short as 1 ms. A brief short or
open causes the multimeter to emit a short beep.
Keysight U1273A/U1273AX Quick Start Guide17
Page 18
Diode tests
S
h
i
f
t
V
i
e
w
E
s
c
Set up your multimeter as shown in the figure
below to perform diode tests.
Auto-diode tests:
Press to use the auto
diode function.
–The Auto-diode function tests both the
forward bias and reverse bias directions of
your diode simultaneously. The forward bias
voltage is shown on the primary display and
the reverse bias voltage is shown on the
secondary display.
18Keysight U1273A/U1273AX Quick Start Guide
Page 19
–GOOD is shown briefly on the secondary
NOTE
display along with a brief beep if the diode is
found to be in good condition. If the diode is
out of the thresholds, NGOOD is shown
instead.
Capacitance measurements
Set up your multimeter as shown in the figure
below to perform capacitance measurements.
is shown on the bottom left of the display when
the capacitor is charging, and is shown when the
capacitor is discharging.
Keysight U1273A/U1273AX Quick Start Guide19
Page 20
Temperature measurements
S
h
i
f
t
V
i
e
w
E
s
c
WARNING
K-type thermocouple
Heat source
NOTE
Set up your multimeter as shown in the figure
below to perform temperature measurements.
Press to switch to the temperature
measurement function.
Do not connect the thermocouple to electrically live
circuits. Doing so will potentially cause fire or electric
shock.
The multimeter uses a type-K (default setting)
temperature probe for measuring temperature.
20Keysight U1273A/U1273AX Quick Start Guide
Page 21
Current measurements
S
h
i
f
t
V
i
e
w
E
s
c
WARNING
NOTE
Set up your multimeter as shown in the figure
below to perform current measurements. Press
to switch between AC, DC, AC+DC, or %
scale current measurements. When measuring
DC current from a mixed signal in DC
measurement mode, ensure that the Filter () is
enabled.
Always use the proper function, range, and terminals for
current measurements. Set the positive input terminal to
the terminal for currents below 440 mA, and
the terminal for currents above 440 mA.
For better accuracy when measuring low currents
(up to μA), turn the rotary switch to the position.
Keysight U1273A/U1273AX Quick Start Guide21
Page 22
Check the Fuse
To check Fuse 1To check Fuse 2
Follow the instructions below for a quick check on
the fuses (Fuse 1 and Fuse 2) of your multimeter.
Fuse
Part
number
12110-1400440 mA/1000 V≈102 ΩOL
22110-140211 A/1000 V≈0.05 ΩOL
Displayed readings
Fuse rating
Fuse healthyReplace fuse
22Keysight U1273A/U1273AX Quick Start Guide
Page 23
NOTE
–To check Fuse 1: Ensure that the probe tip is
touching the top half metal contact inside the
µA mA terminal.
–To check Fuse 2: Ensure that the probe tip is
touching the left half metal contact inside the
A terminal.
The multimeter will sound an input warning alert if
the probe tip is in contact with any other sides of
the µA mA or A terminal other than the sides
specified in the instructions above.
Keysight U1273A/U1273AX Quick Start Guide23
Page 24
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.
24Keysight U1273A/U1273AX Quick Start Guide
Page 25
This information is subject to change
without notice. Always refer to the
Keysight website for the latest revision.