Keysight U1273A, U1273AX Quick Start Manual

Page 1
Keysight U1273A/ U1273AX Handheld Digital Multimeter
Quick Start Guide
Page 2
CAUTION
WARNING
CAT III
1000 V
CAT IV
600 V
Safety symbols
www.keysight.com/find/assist
(worldwide contact information for repair and service)
Safety and EMC Information
This meter is safety-certified in compliance with EN/IEC 61010-1:2001, ANSI/UL 61010-1:2004, and CAN/ CSA-C22.2 No. 61010-1-04 for CAT III 1000 V/CAT IV 600 V pollution degree 2 environment. EMC is designed in compliance with IEC 61326-1:2005/EN 61326-1:2006. Use with standard or compatible test probes.
Safety Notices
A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met.
Earth (ground) terminal
Equipment protected throughout by double insulation or reinforced insulation
Caution, risk of electric shock
Caution, risk of danger (refer to this manual for specific Warning or Caution information)
Category III 1000 V overvoltage protection
Category IV 600 V overvoltage protection
A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met.
For further safety information details, refer to the
Keysight U1273A/U1273AX Handheld Digital Multimeter User’s Guide.
2 Keysight U1273A/U1273AX Quick Start Guide
Page 3
Table of Contents
Install the Batteries . . . . . . . . . . . . . . . . . . . . . . 6
Turn On the Multimeter . . . . . . . . . . . . . . . . . . . 6
The Multimeter at a Glance . . . . . . . . . . . . . . . 8
Understanding the Rotary Switch . . . . . . . . . . . 9
Understanding the Keypad . . . . . . . . . . . . . . . 10
Understanding the Input Terminals . . . . . . . . 11
Performing Measurements and Tests . . . . . . . 12
Voltage measurements . . . . . . . . . . . . . . . . . . . . . .12
Resistance measurements . . . . . . . . . . . . . . . . . . .15
Continuity tests . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Diode tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Capacitance measurements . . . . . . . . . . . . . . . . . .19
Temperature measurements . . . . . . . . . . . . . . . . . .20
Current measurements . . . . . . . . . . . . . . . . . . . . . .21
Check the Fuse . . . . . . . . . . . . . . . . . . . . . . . . 22
Keysight U1273A/U1273AX Quick Start Guide 3
Page 4
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.
4 Keysight U1273A/U1273AX Quick Start Guide
Page 5
Verify that you received the following items in the
NOTE
shipment of your multimeter:
One pair of red and black test leads One pair of 4 mm test probes One K-type thermocouple lead kit Four 1.5 V AAA alkaline batteries (for U1273A)
or lithium batteries (for U1273AX)
Printed copies of the Certificate of Calibration
(CoC) and the U1273A/U1273AX Quick Start Guide (this manual)
If any item is missing or damaged, keep the shipping materials and contact the nearest Keysight Sales Office.
The descriptions and instructions in this guide apply to the U1273A/U1273AX handheld digital multimeter.
All related documents and software are available for download at www.keysight.com/find/hhTechLib.
Keysight U1273A/U1273AX Quick Start Guide 5
Page 6
Install the Batteries
NOTE
Your multimeter is powered by four 1.5 V AAA batteries (included with the shipment).
1 Turn the rotary switch to OFF
and remove the test leads from the terminals.
2 Lift the tilt stand and loosen
the screws with a suitable Phillips screwdriver.
3 Remove the battery cover and observe the
polarity markings.
4 Insert the batteries and replace the battery
cover and screws.
Turn On the Multimeter
To power ON your multimeter, turn the rotary switch from the OFF position to any other position.
Your multimeter is capable of remote data logging. To use this feature, you will need an IR-USB cable (U1173A, purchased separately) and the Keysight GUI Data Logger Software (downloadable from
www.keysight.com/find/hhTechLib).
6 Keysight U1273A/U1273AX Quick Start Guide
Page 7
Auto Dim
By default, the multimeter’s Auto Dim function is enabled. The multimeter’s backlight will dim automatically after 90 seconds of inactivity. Press any button to cancel this effect and reset the Auto Dim timer.
You may change how the multimeter’s backlight behavior through the Setup menu. Refer to the User’s Guide for further instructions.
Keysight U1273A/U1273AX Quick Start Guide 7
Page 8
The Multimeter at a Glance
Display screen
Keypad
Rotary switch
Input terminals
Test lead/probe holders
IR communication port
Battery cover
Tilt stand
(Lift tilt stand for access)
8 Keysight U1273A/U1273AX Quick Start Guide
Page 9
Understanding the Rotary Switch
NOTE
S
h
i
f
t
V
i
e
w
E
s
c
Z
LOW
Smart
Auto
Press to switch between the primary and
shifted functions shown on the rotary switch.
Legend Description
Z
(low input impedance) AC/DC V for eliminating ghost
LOW
voltages
Off
AC V
AC V with Low Pass Filter
AC mV
AC mV with Low Pass Filter
DC V
AC V or AC+DC V
DC mV
AC mV or AC+DC mV
Resistance
Continuity or Smart Ω (offset compensation)
Diode
Auto-diode
Capacitance
Temperature
DC mA (or A)
AC mA (or A) or AC+DC mA (or A)
DC μA
AC μA or AC+DC μA
Keysight U1273A/U1273AX Quick Start Guide 9
Page 10
Understanding the Keypad
S
c
a
l
e
N
u
l
l
P
e
a
k
M
a
x
M
i
n
A
u
t
o
T
r
i
g
H
o
l
d
Exit
Dual
Setup
H
z
%
m
s
L
o
g
A
u
t
o
R
a
n
g
e
S
h
i
f
t
V
i
e
w
E
s
c
Key response when pressed for:
Legend
Less than 1 second More than 1 second
Sets the Null/Relative mode.
Starts the MaxMin recording.
Freezes the present reading in the display.
Switches between available dual-combination displays.
Increases the OLED brightness incrementally when LOW, MEDIUM, or HIGH setting is selected.
Switches between frequency, pulse width, and duty cycle measurements.
Sets the Scale mode for the specified ratio and unit display.
Starts and stops the Peak recording.
Automatically freezes the present reading once the reading is stable.
Exits the Hold, Null, MaxMin, Peak, frequency test, and dual display modes.
Enters and exits the multimeter’s Setup menu.
Starts and stops the Data Logging.
Sets a manual range and disables autoranging.
Switches between the primary and shifted functions.
10 Keysight U1273A/U1273AX Quick Start Guide
Enables auto-ranging.
Enters and exits the Log Review menu.
Page 11
Understanding the Input Terminals
WARNING
Z
LOW
Smart
Auto
or
Ensure that the terminal connections are correct for that particular measurement function before starting any measurement. To avoid damage to the device, do not exceed the input limit.
Rotary position Input terminals Overload protection
1000 Vrms
1000 Vrms for short
circuit <0.3 A
11 A/1000 V
fast-acting fuse
440 mA/1000 V
fast-acting fuse
Keysight U1273A/U1273AX Quick Start Guide 11
Page 12
Performing Measurements and Tests
Voltage measurements
The figure below highlights the primary functions allowing voltage measurements in your multimeter.
Set up your multimeter as shown in the figure below to perform voltage measurements. When measuring DC voltage from a mixed signal in DC measurement mode, ensure that the Filter ( ) is enabled.
12 Keysight U1273A/U1273AX Quick Start Guide
Page 13
1 Press for more than 1 second to enter the
Setup
H
z
%
m
s
L
o
g
Exit
Dual
Setup
H
z
%
m
s
L
o
g
Setup
multimeter’s setup menu.
2 Browse to Menu 6 > Filter, and press to
edit the value.
3 Press or to enable the Filter.
Refer to the table below for the respective firmware versions.
Version 1.64 or older Version 1.95 or newer
on DC
4 Press to save your changes.
5 Press and hold until the multimeter
restarts and returns to normal operation. Turn the multimeter to DC Voltage mode to verify
Keysight U1273A/U1273AX Quick Start Guide 13
that the LPF symbol is turned on.
Page 14
CAUTION
To avoid possible electric shock or personal injury,
S
h
i
f
t
V
i
e
w
E
s
c
Z
LOW
enable the Filter
() to verify the presence of
hazardous DC voltages. Displayed DC voltages can be influenced by high frequency AC components and must be filtered to assure an accurate reading.
LPF during AC measurements:
Press while performing AC voltage measurements to pass the measured signal through a low pass filter.
Passing the measured signal through a LPF
help blocks unwanted voltages such as electronic noise.
Use the LPF function to improve measurement
on composite sine waves that are typically generated by inverters and variable frequency motor drives.
Z
measurements:
LOW
Rotate the rotary switch’s position to to enable low
impedance measurements.
–Use the Z
(low input impedance) function
LOW
to remove ghost or induced voltages from your measurement.
–Z
can remove ghost voltages from your
LOW
measurements by dissipating the coupling voltage. Use Z
to reduce the possibility of
LOW
false readings in areas where the presence of ghost voltages are suspected.
14 Keysight U1273A/U1273AX Quick Start Guide
Page 15
Resistance measurements
S
h
i
f
t
V
i
e
w
E
s
c
Set up your multimeter as shown in the figure below to perform resistance measurements.
Smart Ω measurements:
While performing resistance measurements, press
until BiAS is shown on the secondary display to enable the Smart Ω function.
Use the Smart Ω (offset compensation)
function to measure resistors affected by DC offset or leakage current.
Smart Ω removes unexpected DC voltages
within the instrument, at the input, or at the circuit being measured, which will add error to
Keysight U1273A/U1273AX Quick Start Guide 15
Page 16
resistance measurements. Press to switch
Exit
Dual
S
h
i
f
t
V
i
e
w
E
s
c
Exit
Dual
between the bias voltage (BiAS) display or leakage current (LEAk) display, calculated based on the bias voltage and corrected resistance value, on the secondary display.
Continuity tests
Set up your multimeter as shown in the figure below to perform continuity tests. Press to
switch to the continuity test function ( is shown on the display).
The beeper will sound as a continuity indication. Press to switch between normal open ( )
and normal close ( ) contacts. – Normal open: Circuit is normally open, the
beeper will sound when a short is detected.
Normal close: Circuit is normally closed, the
beeper will sound when an open is detected.
16 Keysight U1273A/U1273AX Quick Start Guide
Page 17
NOTE
The continuity function detects intermittent shorts and opens lasting as short as 1 ms. A brief short or open causes the multimeter to emit a short beep.
Keysight U1273A/U1273AX Quick Start Guide 17
Page 18
Diode tests
S
h
i
f
t
V
i
e
w
E
s
c
Set up your multimeter as shown in the figure below to perform diode tests.
Auto-diode tests:
Press to use the auto diode function.
The Auto-diode function tests both the
forward bias and reverse bias directions of your diode simultaneously. The forward bias voltage is shown on the primary display and the reverse bias voltage is shown on the secondary display.
18 Keysight U1273A/U1273AX Quick Start Guide
Page 19
GOOD is shown briefly on the secondary
NOTE
display along with a brief beep if the diode is found to be in good condition. If the diode is out of the thresholds, NGOOD is shown instead.
Capacitance measurements
Set up your multimeter as shown in the figure below to perform capacitance measurements.
is shown on the bottom left of the display when the capacitor is charging, and is shown when the capacitor is discharging.
Keysight U1273A/U1273AX Quick Start Guide 19
Page 20
Temperature measurements
S
h
i
f
t
V
i
e
w
E
s
c
WARNING
K-type thermocouple
Heat source
NOTE
Set up your multimeter as shown in the figure below to perform temperature measurements.
Press to switch to the temperature measurement function.
Do not connect the thermocouple to electrically live circuits. Doing so will potentially cause fire or electric shock.
The multimeter uses a type-K (default setting) temperature probe for measuring temperature.
20 Keysight U1273A/U1273AX Quick Start Guide
Page 21
Current measurements
S
h
i
f
t
V
i
e
w
E
s
c
WARNING
NOTE
Set up your multimeter as shown in the figure below to perform current measurements. Press
to switch between AC, DC, AC+DC, or % scale current measurements. When measuring DC current from a mixed signal in DC measurement mode, ensure that the Filter ( ) is enabled.
Always use the proper function, range, and terminals for current measurements. Set the positive input terminal to
the terminal for currents below 440 mA, and the terminal for currents above 440 mA.
For better accuracy when measuring low currents (up to μA), turn the rotary switch to the position.
Keysight U1273A/U1273AX Quick Start Guide 21
Page 22
Check the Fuse
To check Fuse 1 To check Fuse 2
Follow the instructions below for a quick check on the fuses (Fuse 1 and Fuse 2) of your multimeter.
Fuse
Part
number
1 2110-1400 440 mA/1000 V ≈102 Ω OL
2 2110-1402 11 A/1000 V ≈0.05 Ω OL
Displayed readings
Fuse rating
Fuse healthy Replace fuse
22 Keysight U1273A/U1273AX Quick Start Guide
Page 23
NOTE
To check Fuse 1: Ensure that the probe tip is
touching the top half metal contact inside the µA mA terminal.
To check Fuse 2: Ensure that the probe tip is
touching the left half metal contact inside the A terminal.
The multimeter will sound an input warning alert if the probe tip is in contact with any other sides of the µA mA or A terminal other than the sides specified in the instructions above.
Keysight U1273A/U1273AX Quick Start Guide 23
Page 24
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.
24 Keysight U1273A/U1273AX Quick Start Guide
Page 25
This information is subject to change without notice. Always refer to the Keysight website for the latest revision.
© Keysight Technologies 2012-2017 Edition 4, June 1, 2017
Printed in Malaysia
*U1273-90004*
U1273-90004
www.keysight.com