Keysight U1231A, U1232A, U1233A Quick Start Guide

Keysight U1231A/ U1232A/U1233A Handheld Multimeter
Quick Start Guide
CAUTION
WARNING
CAT III
600 V
ENGLISH
Contacting Keysight
www.keysight.com/find/assist
Safety and EMC Information
This meter is safety-certified in compliance with EN 61010-1/IEC 61010-1. Measurement Category CAT III 600 V; Pollution Degree II.
EMC designed in compliance with EN61326-1/IEC61326-1. Use with standard or compatible test probes.
Safety Notices
Safety symbols
Earth (ground) terminal
Equipment protected throughout by double insulation or reinforced insulation
Caution, risk of danger (refer to this manual for specific Warning or Caution information)
Fuse
A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met.
Alternating current
Direct current
Battery, general
Category III 600 V overvoltage protection
A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met.
For further safety information details, refer to the
Keysight U1231A/U1232A/U1233A Handheld Multimeter User’s Guide.
2 Keysight U1231A/U1232A/U1233A Quick Start Guide
Verify that you received the following items in the
NOTE
shipment of your multimeter:
U1167A 4 mm tips probes test leads 4 x 1.5 V batteriesCertificate of Calibration
If any item is missing or damaged, keep the shipping materials and contact the nearest Keysight Sales Office.
The descriptions and instructions in this guide apply to the U1231A, U1232A, and U1233A handheld multimeters.
The model U1233A appears in all illustrations.
All related documents and software are available for download at www.keysight.com/find/hhTechLib.
ENGLISH
Keysight U1231A/U1232A/U1233A Quick Start Guide 3
ENGLISH
To PC (host)

Install the Batteries

Your multimeter is powered by four 1.5 V AAA alkaline batteries (included with the shipment).
1 Turn the multimeter OFF and
remove the test leads from the terminals.
2 Loosen the screw on the battery
cover with a suitable Phillips screwdriver.
3 Remove the battery cover and
observe the polarity markings.
4 Insert the batteries and replace the battery
cover and screw.

Turn On the Multimeter

To power ON your multimeter, turn the rotary switch to any other position.

Controlling the Multimeter Remotely

Your multimeter is capable of remote data logging.
To use this feature, you will need a PC running a Windows operating system, an IR-USB cable
(U1173A, purchased separately), and the Keysight GUI Data Logger Software.
4 Keysight U1231A/U1232A/U1233A Quick Start Guide
The Keysight GUI Data Logger software is
Vsense ind icator
Keypad
Rotary switch
LED flashl ight
Battery cover
Tilt stand
Display screen
Input terminals
Test lead/probe holders
IR communication port
(U1233A only)
downloadable for free from www.keysight.com/
find/hhTechLib.

The Multimeter at a Glance

ENGLISH
Keysight U1231A/U1232A/U1233A Quick Start Guide 5
ENGLISH
NOTE
S
h
i
f
t
E
s
c
WARNING
Hz
AUX
Hz
Hz
AUX
Hz
AUX

Understanding the Rotary Switch

Some rotary switch positions have a shifted function printed in orange. Press to switch
between the shifted and regular function.
Legend Functions shown in the primary display
Low input impedance — VZ
DC V/VZ
VZ
LOW
AC V for eliminating ghost voltages
LOW
AC V/Frequency
DC V
Resistance/Short continuity/Open continuity
Diode
Capacitance/Temperature (U1233A only)
Capacitance/Auxiliary Temperature (U1232A only)
Capacitance (U1231A only)
DC or AC A/Frequency
DC or AC μA/Frequency
Auto (AC or DC)/
LOW
[a]
Clamp-on AC or DC A/Frequency (U1231A only)
Auxiliary Temperature (U1231A only)
[a] Open continuity option must be enabled through the multimeter’s Setup ( >
). Open continuity is disabled by default.
Remove the test leads from the measuring source or target before changing the rotary switch position.
Refer to the U1231A/U1232A/U1233A User’s Guide for a complete list and description of all rotary switch labels for each separate multimeter model.
6 Keysight U1231A/U1232A/U1233A Quick Start Guide