Verify that you received the following items in the shipment of
your clamp meter:
✔ One pair of red and black test leads
✔ Two 1.5 V AAA alkaline batteries
✔ One K-type thermocouple (U1194A only)
✔ One soft carrying case
✔ Printed copies of the Certificate of Calibration (CoC) and
the U1190A Series Quick Start Guide (this manual)
If any item is missing or damaged, keep the shipping materials
and contact the nearest Keysight Sales Office.
The descriptions and instructions in this guide apply to the
U1191A, U1192A, U1193A, and U1194A handheld clamp
meters.
The model U1194A appears in all illustrations.
All related documents and software are available for download
at www.keysight.com/find/hhTechLib.
Page 2
U1190A Series Handheld Clamp Meter
Mesh of
wires or
cables
1 Open the clamp jaw
slightly to reveal the
wire separator tip.
2 Separate the
desired wire or
cable by hooking it
in the clamp jaw.
3 Secure the
wire or cable
and read the
measurement.
Install the Batteries
Install the Batteries
Your clamp meter is powered by two
1.5 V AAA alkaline batteries (included
with the shipment).
1 Turn the clamp meter OFF and remove
the test leads from the terminals.
2 Loosen the screw on the battery cover
with a suitable Phillips screwdriver.
3 Remove the battery cover and observe
the polarity markings.
4 Insert the batteries and replace the
battery cover and screw.
Power ON the Clamp Meter
To po w e r O N y o u r c l a m p m e t e r,
turn the rotary switch from the
OFF position to any other posi
tion.
Using the Wire Separator and Hook
-
2U1190A Series Quick Start Guide
Page 3
U1190A Series Handheld Clamp Meter
Hold/MaxMin button
Function buttons
Rotary switch
Display screen
Input terminals
Front view
Clamp jaw
Jaw markings
Handle
Battery cover
Flashlight
Hand guard
Rear view
The Clamp Meter at a Glance
The Clamp Meter at a Glance
U1190A Series Quick Start Guide3
Page 4
U1190A Series Handheld Clamp Meter
NOTE
WARNING
Understanding the Rotary Switch
Understanding the Rotary Switch
Some rotary switch positions have a shifted function printed in
orange. Press to switch between the shifted and primary
function.
Legend
Functions shown
in the primary display
Off
AC A
DC A
Frequency
(current path)
AC V
Frequency
(voltage path)
DC V
Resistance
Continuity
Diode
Capacitance
Non-contact voltage
detector
U1194A U1193A U1192A U1191A
✔✔✔✔
✔✔✔✔
✔
✔✔✔
✔✔✔✔
✔✔✔
✔✔✔✔
✔✔✔✔
✔✔✔✔
✔✔✔✔
✔✔✔
✔✔✔
Temperature
DCμA
AC μA
Remove the test leads from the measuring source or
target before changing the rotary switch position.
4U1190A Series Quick Start Guide
✔
✔
✔
Page 5
U1190A Series Handheld Clamp Meter
3
4
Voltage source
AC
2
1
WARNING
Understanding the Function Buttons
Understanding the Function Buttons
Legend
[1]
The LED flashlight function is available for U1194A/U1193A/U1192A models
only.
Key response when pressed for:
Less than 1 secondMore than 1 second
Freezes the present reading
in the display.
Records the maximum,
minimum, or average value.
Switches between the
primary and shifted functions.
Turns the LCD backlight
on or off.
Turns the LED flashlight
on or off.
[1]
Sets the null/relative mode.-
Non-contact voltage
detector (Vsense)
If the presence of AC voltage is
sensed, the clamp meter’s beeper
will sound.
Press to change the Vsense
sensitivity from Hi.SE (high sensitivity) to Lo.SE (low sensitivity) and
vice versa.
-
U1190A Series Quick Start Guide5
Voltage could still be
present even if there is no
alert indication. Never
touch live voltages or
conductors without the
necessary insulation
protection.
Page 6
U1190A Series Handheld Clamp Meter
3
1
2
4
5
Conductor
WARNING
CAUTIONCAUTION
Current
flow
Current
flow
CorrectIncorrect
✔✘
Performing Measurements
Performing Measurements
Current measurement
Press the handle to open the
clamp jaw. Clamp around a con
ductor and ensure that the conductor fits the markings on the
clamp jaw.
Press to cycle between AC
current, DC current, or to read
the frequency of the AC current.
-
Ensure that the test leads
are disconnected from the
input terminals when
measuring current with the
clamp meter’s jaw.
Ensure that the clamp meter measures only one conductor
at a time. Measuring multiple conductors may cause inaccuracy in measurement reading due to the vector sum of
currents flowing in the conductors.
6U1190A Series Quick Start Guide
Page 7
U1190A Series Handheld Clamp Meter
2
4
AC
Voltage source
1
3
DC
3
Voltage source
1
2
Performing Measurements
AC voltage measurement
Set up your clamp meter to measure AC voltage as shown. Probe
the test points and read the dis
play.
Press to measure the frequency of the AC voltage source.
-
DC voltage measurement
Set up your clamp meter to measure DC voltage as shown. Probe
the test points and read the dis
play.
-
U1190A Series Quick Start Guide7
Page 8
U1190A Series Handheld Clamp Meter
3
Resistor
1
2
CAUTION
4
1
3
CLOSED
OPEN
2
NOTE
Performing Measurements
Resistance measurement
Set up your clamp meter to measure resistance as shown. Probe
the test points and read the dis
-
play.
To avoid possible damage to
your clamp meter or to the
equipment under test, disconnect the circuit power
and discharge all high-voltage capacitors before measuring resistance or testing
for continuity.
Continuity test
Set up your clamp meter to test
for continuity as shown. Press
to switch to the continuity
test function ( is shown on the
display).
The beeper will sound and the
backlight will flash when the
circuit-under-test is shorted.
8U1190A Series Quick Start Guide
Page 9
U1190A Series Handheld Clamp Meter
3
Forward-bias
diode
1
2
NOTE
2
4
Capacitor
1
3
CAUTION
Performing Measurements
Diode test
Set up your clamp meter to test
diodes as shown. Probe the test
points and read the display.
This test sends a current
through a semiconductor
junction, and then measures
the junction’s voltage drop. A
good diode allows current to
flow in one direction only.
Capacitance measurement
Set up your clamp meter to measure capacitance as shown. Press
to switch to the capacitance
measurement function.
To avoid possible damage to
the clamp meter or to the
equipment under test, disconnect circuit power and
discharge all high-voltage
capacitors before measuring capacitance. Use the
DC V function to confirm
that the capacitor is fully
discharged.
U1190A Series Quick Start Guide9
Page 10
U1190A Series Handheld Clamp Meter
2
4
1
3
K-type
thermocouple
probe
Heat source
WARNING
AC
2
4
1
Voltage source
DC
Voltage source
LOAD
3
LOAD
WARNING
Performing Measurements
Temperature
measurement (U1194A
only)
The clamp meter uses a
type-K thermocouple probe
for measuring temperature.
Press
temperature measurement
function.
Do not connect the
thermocouple to
electrically live circuits.
Doing so will potentially
cause fire or electric
shock.
to switch to the
Current measurement
up to μA (U1194A only)
Set up your clamp meter to
measure low current as
shown. Press
the current measurement
function.
Always use the proper
function, range, and
terminals for current
measurements. Use the
clamp jaw for currents
above 600
to switch to
μA.
10U1190A Series Quick Start Guide
Page 11
Contacting Keysight
CAUTIONCAUTION
WARNING
CAT III
600 V
CAT IV
300 V
To obtain service, warranty, or technical assistance, contact us at the following phone numbers:
• United States Call Center: 800-829-4444
• Canada Call Center: 877-894-4414
• China Call Center: 800-810-0189
• Europe Call Center: 31-20-547-2111
• Japan Call Center: (81) 426-56-7832
For other countries, contact your country’s Keysight support organization.
A list of contact information for other countries is available on the Keysight
Web site:
www.keysight.com/find/assist
Safety NoticesSafety Information
A CAUTION notice denotes
a hazard. It calls attention
to an operating procedure,
practice, or the like that, if
not correctly performed or
adhered to, could result in
damage to the product or
loss of important data. Do
not proceed beyond a CAU-TION notice until the indicated conditions are fully
understood and met.
A WARNING notice
denotes a hazard. It calls
attention to an operating
procedure, practice, or the
like that, if not correctly
performed or adhered to,
could result in personal
injury or death. Do not proceed beyond a WARNING
notice until the indicated
conditions are fully understood and met.
This meter is safety-certified in compliance
with EN 61010-1 (IEC 61010-1:2001 and
IEC/EN 61010-2-032:2002) for a CAT III 600
V and CAT IV 300 V pollution degree 2 environment. EMC is designed in compliance
with IEC 61326-1:2005/EN 61326-1:2006.
Use with standard or compatible test
probes.
Safety Symbols
Earth (ground) terminal
Equipment protected
throughout by double insulation or reinforced insulation
Caution, risk of danger (refer
to the instrument manual for
specific Warning or Caution
information)
Application around and
removal from HAZARDOUS
LIVE conductors is permitted
Category III 600 V
overvoltage protection
For further safety information details, refer to the
Keysight U1190A Series Handheld Clamp Meter User’s Guide.
Category IV 300 V
overvoltage protection
Page 12
This information is subject to change without notice.