Keysight U1191A, U1194A, U1192A, U1193A Quick Start Manual

Page 1
NOTE
Keysight U1190A Series Handheld Clamp Meter
Quick Start Guide
Verify that you received the following items in the shipment of your clamp meter:
One pair of red and black test leadsTwo 1.5 V AAA alkaline batteriesOne K-type thermocouple (U1194A only)One soft carrying casePrinted copies of the Certificate of Calibration (CoC) and
the U1190A Series Quick Start Guide (this manual)
The descriptions and instructions in this guide apply to the U1191A, U1192A, U1193A, and U1194A handheld clamp meters.
The model U1194A appears in all illustrations. All related documents and software are available for download
at www.keysight.com/find/hhTechLib.
Page 2
U1190A Series Handheld Clamp Meter
Mesh of wires or cables
1 Open the clamp jaw
slightly to reveal the wire separator tip.
2 Separate the
desired wire or cable by hooking it in the clamp jaw.
3 Secure the
wire or cable and read the measurement.
Install the Batteries
Install the Batteries
Your clamp meter is powered by two
1.5 V AAA alkaline batteries (included with the shipment).
1 Turn the clamp meter OFF and remove
the test leads from the terminals.
2 Loosen the screw on the battery cover
with a suitable Phillips screwdriver.
3 Remove the battery cover and observe
the polarity markings.
4 Insert the batteries and replace the
battery cover and screw.
Power ON the Clamp Meter
To po w e r O N y o u r c l a m p m e t e r, turn the rotary switch from the OFF position to any other posi tion.
Using the Wire Separator and Hook
-
2 U1190A Series Quick Start Guide
Page 3
U1190A Series Handheld Clamp Meter
Hold/MaxMin button
Function buttons
Rotary switch
Display screen
Input terminals
Front view
Clamp jaw
Jaw markings
Handle
Battery cover
Flashlight
Hand guard
Rear view
The Clamp Meter at a Glance
The Clamp Meter at a Glance
U1190A Series Quick Start Guide 3
Page 4
U1190A Series Handheld Clamp Meter
NOTE
WARNING
Understanding the Rotary Switch
Understanding the Rotary Switch
Some rotary switch positions have a shifted function printed in
orange. Press to switch between the shifted and primary
function.
Legend
Functions shown in the primary display
Off
AC A
DC A
Frequency (current path)
AC V
Frequency (voltage path)
DC V
Resistance
Continuity
Diode
Capacitance
Non-contact voltage detector
U1194A U1193A U1192A U1191A
✔✔✔✔ ✔✔✔✔ ✔
✔✔✔
✔✔✔✔
✔✔✔
✔✔✔✔ ✔✔✔✔ ✔✔✔✔ ✔✔✔✔ ✔✔✔
✔✔✔
Temperature
DC μA
AC μA
Remove the test leads from the measuring source or target before changing the rotary switch position.
4 U1190A Series Quick Start Guide
✔ ✔ ✔
Page 5
U1190A Series Handheld Clamp Meter
3
4
Voltage source
AC
2
1
WARNING
Understanding the Function Buttons
Understanding the Function Buttons
Legend
[1]
The LED flashlight function is available for U1194A/U1193A/U1192A models only.
Key response when pressed for:
Less than 1 second More than 1 second
Freezes the present reading in the display.
Records the maximum, minimum, or average value.
Switches between the primary and shifted functions.
Turns the LCD backlight on or off.
Turns the LED flashlight on or off.
[1]
Sets the null/relative mode. -
Non-contact voltage detector (Vsense)
If the presence of AC voltage is sensed, the clamp meter’s beeper will sound.
Press to change the Vsense sensitivity from Hi.SE (high sensi­tivity) to Lo.SE (low sensitivity) and vice versa.
-
U1190A Series Quick Start Guide 5
Voltage could still be present even if there is no alert indication. Never touch live voltages or conductors without the necessary insulation protection.
Page 6
U1190A Series Handheld Clamp Meter
3
1
2
4
5
Conductor
WARNING
CAUTIONCAUTION
Current flow
Current flow
Correct Incorrect
Performing Measurements
Performing Measurements
Current measurement
Press the handle to open the clamp jaw. Clamp around a con ductor and ensure that the con­ductor fits the markings on the clamp jaw.
Press to cycle between AC current, DC current, or to read the frequency of the AC current.
-
Ensure that the test leads are disconnected from the input terminals when measuring current with the clamp meter’s jaw.
Ensure that the clamp meter measures only one conductor at a time. Measuring multiple conductors may cause inac­curacy in measurement reading due to the vector sum of currents flowing in the conductors.
6 U1190A Series Quick Start Guide
Page 7
U1190A Series Handheld Clamp Meter
2
4
AC
Voltage source
1
3
DC
3
Voltage source
1
2
Performing Measurements
AC voltage measurement
Set up your clamp meter to mea­sure AC voltage as shown. Probe the test points and read the dis play.
Press to measure the fre­quency of the AC voltage source.
-
DC voltage measurement
Set up your clamp meter to mea­sure DC voltage as shown. Probe the test points and read the dis play.
-
U1190A Series Quick Start Guide 7
Page 8
U1190A Series Handheld Clamp Meter
3
Resistor
1
2
CAUTION
4
1
3
CLOSED
OPEN
2
NOTE
Performing Measurements
Resistance measurement
Set up your clamp meter to mea­sure resistance as shown. Probe the test points and read the dis
-
play.
To avoid possible damage to your clamp meter or to the equipment under test, dis­connect the circuit power and discharge all high-volt­age capacitors before mea­suring resistance or testing for continuity.
Continuity test
Set up your clamp meter to test for continuity as shown. Press
to switch to the continuity test function ( is shown on the display).
The beeper will sound and the backlight will flash when the circuit-under-test is shorted.
8 U1190A Series Quick Start Guide
Page 9
U1190A Series Handheld Clamp Meter
3
Forward-bias diode
1
2
NOTE
2
4
Capacitor
1
3
CAUTION
Performing Measurements
Diode test
Set up your clamp meter to test diodes as shown. Probe the test points and read the display.
This test sends a current through a semiconductor junction, and then measures the junction’s voltage drop. A good diode allows current to flow in one direction only.
Capacitance measurement
Set up your clamp meter to mea­sure capacitance as shown. Press
to switch to the capacitance
measurement function.
To avoid possible damage to the clamp meter or to the equipment under test, dis­connect circuit power and discharge all high-voltage capacitors before measur­ing capacitance. Use the DC V function to confirm that the capacitor is fully discharged.
U1190A Series Quick Start Guide 9
Page 10
U1190A Series Handheld Clamp Meter
2
4
1
3
K-type thermocouple probe
Heat source
WARNING
AC
2
4
1
Voltage source
DC
Voltage source
LOAD
3
LOAD
WARNING
Performing Measurements
Temperature measurement (U1194A only)
The clamp meter uses a type-K thermocouple probe for measuring temperature. Press temperature measurement function.
Do not connect the thermocouple to electrically live circuits. Doing so will potentially cause fire or electric shock.
to switch to the
Current measurement up to μA (U1194A only)
Set up your clamp meter to measure low current as shown. Press the current measurement function.
Always use the proper function, range, and terminals for current measurements. Use the clamp jaw for currents above 600
to switch to
μA.
10 U1190A Series Quick Start Guide
Page 11
Contacting Keysight
CAUTIONCAUTION
WARNING
CAT III
600 V
CAT IV
300 V
To obtain service, warranty, or technical assistance, contact us at the fol­lowing phone numbers:
United States Call Center: 800-829-4444
Canada Call Center: 877-894-4414
China Call Center: 800-810-0189
Europe Call Center: 31-20-547-2111
Japan Call Center: (81) 426-56-7832
For other countries, contact your country’s Keysight support organization. A list of contact information for other countries is available on the Keysight Web site:
www.keysight.com/find/assist
Safety Notices Safety Information
A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAU- TION notice until the indi­cated conditions are fully understood and met.
A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not pro­ceed beyond a WARNING notice until the indicated conditions are fully under­stood and met.
This meter is safety-certified in compliance with EN 61010-1 (IEC 61010-1:2001 and IEC/EN 61010-2-032:2002) for a CAT III 600 V and CAT IV 300 V pollution degree 2 envi­ronment. EMC is designed in compliance with IEC 61326-1:2005/EN 61326-1:2006. Use with standard or compatible test probes.
Safety Symbols
Earth (ground) terminal
Equipment protected throughout by double insula­tion or reinforced insulation
Caution, risk of danger (refer to the instrument manual for specific Warning or Caution information)
Application around and removal from HAZARDOUS LIVE conductors is permitted
Category III 600 V overvoltage protection
For further safety information details, refer to the
Keysight U1190A Series Handheld Clamp Meter User’s Guide.
Category IV 300 V overvoltage protection
Page 12
This information is subject to change without notice.
© Keysight Technologies 2011, 2015
Edition 2, January 2015
*U1191-90001*
U1191-90001
www.keysight.com