Configuring the U1177A Remotely via Hyper Terminal
NOTE
Configuring the U1177A Remotely via Hyper Terminal
Hyper Terminal is a program that enables you to configure
your U1177A remotely using AT commands — in this case
via a Bluetooth connection.
Before you begin, ensure that the Bluetooth connection on your PC is
enabled.
1 Set the U1177A slide switch to Setup.
2 From your PC, go to Start > All Programs > Accessories >
Communication > Hyper Terminal.
3 Set your telnet program. You may choose to set Hyper
Terminal as your default telnet program.
4 Create a new connection for your U1177A. Go to File >
New Connection. In the Connection Description window, type
U1177A and select the appropriate icon. Click OK.
5 The Connect To window will be displayed. Go to Connect
using and select a COM from the drop- down list. Click OK.
6 When the COM port settings are displayed, set the
parameters accordingly as below and click OK.
• Bit = 9600
• Data Bit = 8
• Parity = None
• Stop Bit = 1
• Flow Control = None
7 Configure or retrieve information from your U1177A using
the AT command list shown in the following pages.
U1177A Configuration Guide1
AT Command List
AT Command List
CommandUser description
ATG
Power Management
Control
ATI
Information
This command controls the deep sleep timer. The U1177A will enter the deep sleep
mode and turn off all the LEDs when there is no event activity. The timer will restart
once an event interrupts the timer. The U1177A will wake up once the UART
receives a proper signal.
ModifierDescription
• Set the deep sleep timer in seconds
• xxxxx can be set in the range of 60 to 65535.
ATG=xxxxx
ATG 0
ATG1 (Default)
ATG ?
This command allows you to acquire information
ModifierDescription
ATI0Acquire the firmware version
The accuracy is ±2 seconds.
• Setting G=0 will disable the timer
• Default value = 900
Disable wake up from UART. Changes to this setting may lead to
a system reboot.
Enable wake up from UART. Changes to this setting may lead to
a system reboot.
Acquire current settings
2U1177A Configuration Guide
ATI1Acquire the setting list
ATI2Acquire the RSSI at the online command mode
CommandUser description
AT Command List
ATL
Baud Rate Control
ATP
PIN Code Setting
This command sets the baud rate for the COM port.
ModifierDescription
ATL#Set the baud rate to 2400 bps
ATL0Set the baud rate to 4800 bps
ATL1 (Default)Set the baud rate to 9600 bps
ATL2Set the baud rate to 19200 bps
ATL?Acquire the current baud rate setting
This command sets the PIN number for your device. It can be used to set the PIN
code authorization to Off. Default PIN = 1234.
ModifierDescription
ATP=xxxx
(Default)
ATP0Turn off the PIN code authorization
ATP?Acquire the current PIN code setting
• Set PIN number
• xxxx can be set in the range of four numeric digits
ATZ
Restore
This command reboots and restores the device to default settings.
ModifierDescription
ATZ0Set the device to default settings
U1177A Configuration Guide3
AT Command List
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.
4U1177A Configuration Guide
www.keysight.com
Contact us
To obtain service, warranty, or technical
assistance, contact us at the following
phone or fax numbers:
United States:
(tel) 800 829 4444(fax) 800 829 4433
Canada:
(tel) 877 894 4414(fax) 800 746 4866
China:
(tel) 800 810 0189(fax) 800 820 2816
Europe:
(tel) 31 20 547 2111
Japan:
(tel) 0120 (421) 345 (fax) 0120 (421) 678
Korea:
(tel) (080) 769 0800 (fax) (080) 769 0900
Latin America:
(tel) (305) 269 7500
Ta i w a n :
(tel) 0800 047 866 (fax) 0800 286 331
Other Asia Pacific Countries:
(tel) (65) 6375 8100 (fax) (65) 6755 0042
Or visit Keysight World Wide Web at:
www.keysight.com/find/assist
Product specifications and descriptions in
this document are subject to change
without notice. Always refer to the
Keysight Web site for the latest revision.
This information is subject to change without notice.