Find us at www.keysight.com Page 1
FieldFox Handheld Analyzers
4/6.5/9/14/18/26.5/32/44/50/54 GHz
This configuration guide describes configurations, options, and
accessories for the FieldFox “B”-Series family of portable analyzers.
Use this guide, along with the technical overview and data sheet, for a
complete description of the analyzers. The table on page 3 titled
“FieldFox Family and Options” shows a comparison of the functions
available in the FieldFox family of analyzers.
Note: Combination analyzer (combo) = Cable and antenna tester
(CAT) + Vector network analyzer (VNA) + Spectrum analyzer (SA)
The following accessories
are included with every
FieldFox:
•
AC/DC adapter
•
Battery
•
Soft carrying case
•
LAN cable
•

Find us at www.keysight.com Page 2
Table of Contents
FieldFox Family and Options
...................................................................................................................... 3
FieldFox RF and Microwave (Combination) Analyzers
.............................................................................. 4
FieldFox RF and Microwave (Combination) Analyzer FAQs
..................................................................... 6
ERTA System Typical Configuration ........................................................................................................... 10
FAQs – Applicable to all FieldFox RF and Microwave Analyzers
.......................................................... 11
FieldFox Signal Analyzers ........................................................................................................................... 13
FieldFox Signal Analyzer FAQs .................................................................................................................. 14
Upgrades ..................................................................................................................................................... 15
Documentation ............................................................................................................................................ 18
Calibration Kits ............................................................................................................................................ 18
Accessories ................................................................................................................................................. 20

Find us at www.keysight.com Page 3
FieldFox Family and Options
Combination Analyzers
N9913/4/5/6/7/8B
N9950/1/2/3B
Signal Analyzers
N9933/4/5/6/7/8B
N9960/1/2/3B
CAT / vector network analysis
VNA transmission/reflection
VNA full 2-port S-parameters
1-port mixed-mode S-parameters
Cable and antenna analyzer
Reflection meas. (RL, VSWR and scalar meas.)
Extended range transmission analysis (ERTA)
Interference analyzer and spectrogram
Spectrum analyzer time gating
Real-time spectrum analyzer (RTSA)
Indoor and outdoor mapping
Phased array antenna support
Over-the-air (OTA) LTE FDD
Over-the-air (OTA) LTE TDD
Analysis bandwidth, 40 MHz5
Analysis bandwidth, 120 MHz5
USB power sensor meas. versus frequency
Pulse meas. with USB peak power sensor
Base model functionality listed is the primary function of that instrument. For example, on the N991x/5xB combo
analyzers, cable and antenna analyzer is the standard function included with every N991x/5xB.
Option 305 is not available on the N993x/6xB. A subset of measurements, return loss and VSWR, is available as
Option 320.
Option 320 is not applicable to N991x/5xB. The N991x/5xB includes reflection measurements of return loss and
VSWR as standard functions.
On the N991x/5xB analyzers, order Options 233 and 210 to obtain a tracking generator with the spectrum analyzer.
There is no Option 220 on the N991x/5xB analyzers. Option 233 provides the spectrum analyzer capability and
Op tio n 2 10 the “t r ac k ing ” c apa b il ity .

Find us at www.keysight.com Page 4
Combination Analyzers
N9913/4/5/6/7/8B
N9950/1/2/3B
Spectrum Analyzers
N9933/4/5/6/7/8B
N9960/1/2/3B
Remote control capability
DC bias variable-voltage source
Frequency extender support1
PathWave VSA (89600 VSA) software
FieldFox RF and Microwave (Combination) Analyzers
Analyzer models
Step 1. Select the model that provides the desired frequency range.
4 GHz FieldFox RF analyzer
6.5 GHz FieldFox RF analyzer
9 GHz FieldFox microwave analyzer
14 GHz FieldFox microwave analyzer
18 GHz FieldFox microwave analyzer
26.5 GHz FieldFox microwave analyzer
32 GHz FieldFox microwave analyzer
44 GHz FieldFox microwave analyzer
50 GHz FieldFox microwave analyzer
54 GHz FieldFox microwave analyzer
Models N9913/33B, N9914/34B and N9915/35B do not suppor t f r equ en c y e xte n de rs. Th i s i s b eca use th e m ixe r s’
starting LO frequency is higher than 9 GHz and the FieldFox Port 1 provides the LO to the mixer. For a list of
supported OML frequency extenders, see Accessories page 22.

Find us at www.keysight.com Page 5
Analyzer options
Step 2. Select optional measurement capabilities.
Any of these options can easily be added as a software upgrade in the future.
Prerequisite options/notes
CAT / vector network analysis
Requires 210, recommend 211. See FAQ #7
VNA transmission/reflection
Recommend ordering a calibration kit. See FAQ #4 and FAQ #6
VNA full 2-port S-parameters
Requires 210, recommend ordering a calibration kit. See FAQ #5
1-port mixed-mode S-parameters
210 and 211 required for full VVM functionality. See FAQ #8
Extended range transmission analysis
(ERTA)
Requires 233 and 210. Recommend 307. Requires two FieldFox units. See
FAQ # 9. See page 10 for typical configuration.
Interference analyzer and spectrogram
Spectrum analyzer time gating
Real-time spectrum analyzer (RTSA)
Requires 233, Recommend 235. See FAQ # 11
Indoor and outdoor mapping
Requires 233, 307, and at least one of 312, 360, 370, 377 or 378.
See FAQ #15
Requires 233, 235, 309 and accessory item N9910X-713 BNC to SMB cable.
See FAQ #13 for external preamplifier and noise source requirements.
Requires 233. Also requires triaxial antenna. See FAQ #16
Phased array antenna support
Requires 233. N991x/3xB (x>5) models require external mixer. No external
mixer required for N995x/6xB models. See FAQ #14
Over-the-air (OTA) LTE FDD
Requires 233 and 307. Recommend 235.
Over-the-air (OTA) LTE TDD
Requires 233 and 307. Recommend 235.
Requires 233 and 307. Recommend 235. N991x/3xB (x>5) models require
external mixer. See FAQ #14 No external mixer required for N995x/6xB
models. 5G TF is pre-5G standard
Requires 233, B10, and 307. Recommend 235. N991x/3xB (x>5) models with
FR2 frequencies above 26.5 GHz require external mixer. See FAQ #18. No
external mixer required for N995x/6xB models.
Analysis bandwidth, 40 MHz1
Requires 233. Recommend 350, 351 or 89600 VSA software.
Analysis bandwidth, 120 MHz1
Requires 233. Recommend 350, 351, 378 or 89600 VSA software.
USB power sensor meas. versus frequency
Need to order USB power sensor 2. See FAQ A
No power sensor required. See FAQ B
Pulse meas. with USB peak power sensor
Requires 302 and USB peak power sensor. See FAQ G and FAQ H
List of compatible sensors available from www.keysight.com/find/fieldfoxsupport

Find us at www.keysight.com Page 6
Prerequisite options/notes
Remote control capability
Need to order GPS antenna, N9910X-825. See FAQ C
DC bias variable-voltage source
Recommend N9910X-713 cable. See FAQ D
Frequency extender support
Requires 233. Optional 350, 351, 360, 370, 377, 378, PathWave VSA
software. See Accessories, page 22
PathWave VSA (89600 VSA) software
Requires 233, 235 and 307. See FAQ #17
FieldFox RF and Microwave (Combination) Analyzer FAQs
1. What is included with a base
N991x/5xB analyzer?
The base model includes the cable and antenna analyzer
Measurements: DTF (dB, linear, VSWR), return loss and DTF, return loss (dB), and 1-port cable
loss
Calibrations: CalReady, OSL, and response calibration
Note: 2-port insertion loss is NOT included with the base model, if 2-port insertion loss is needed,
order Option 210
Note: Base analyzer does not have phase information, for S11 or S21 phase, order Option 210
2. What is included with N991x/5xB
Option 233?
Basic spectrum analysis, four traces, different detector types, radio standard selection, limit lines
Channel power, occupied bandwidth, adjacent channel power, spectrum emission mask
AM/FM tune and listen, field strength measurements, antenna factors, frequency counter marker
Tracking generator (TG)/Independent source:
- TG CW mode (source CW frequency can be set independent of SA frequency) - included
- TG CW coupled mode (source CW frequency auto coupled to SA’s center frequency) - included
- TG tracking mode (traditional TG operation, swept SA coupled to swept source) - (requires
Option 210)
3. What is included with N991x/5xB
Option 236?
Interference analyzer and spectrogram, trace playback and recording
4. What is included with N991x/5xB
Option 210?
Option 210 adds a VNA with transmission/reflection (T/R) capability
Measurements: S21, S11, magnitude and phase
Additionally, in the CAT mode, you can measure 2-port insertion loss
Calibrations: CalReady, OSL, response, and enhanced response calibration
If you need all four S-parameters, order Options 210 and 211
If you need 2-port calibration, order Options 210 and 211
Adds tracking mode to the tracking generator/independent source included with Option 233,
spectrum analyzer
5. What is included with N991x/5xB
Option 211?
Option 211 adds full 2-port S-parameter capability to the VNA mode
Measurements: All four S-parameters (S11, S21, S22, S12), magnitude and phase
Calibrations: CalReady, OSL, response, enhanced response, and full 2-port calibration

Find us at www.keysight.com Page 7
6. Can I measure group delay on
N991x/5xB analyzers?
If you have phase measurement capability, then you can measure group delay. Option 210 is
required for any phase measurement capability. So, if you do not have Option 210, you cannot
measure group delay.
7. What is included with N991x/5xB
Option 010?
S11/S21 in time domain if Option 210 is ordered. To get time domain data for all four Sparameters and full 2-port calibration, order Option 211.
View both time and frequency domain data at the same time
Low-pass, impulse, and band-pass modes
Minimum, medium, and maximum window
8. What is included with N991x/5xB
Option 308?
With Option 308: 1-port cable trimming
With Options 308 and 210: 1-port cable trimming, 2-port transmission
With Options 308, 210, and 211: 1-port cable trimming, 2-port transmission, A/B and B/A
Note: A/B and B/A measurements require an external source
9. What are the requirements for
Option 209?
Extended Range Transmission Analysis (ERTA) or Option 209 is a scalar measurement system
based on the use of two (2) FieldFox units. One FieldFox acts as the source and reference
receiver, while the second FieldFox acts as the measurement receiver. When different frequency
models are used in an ERTA pair, the system frequency range is limited to the lowest of the pair.
A. Two (2) FieldFox units. FieldFox units can be any of these models:
- FieldFox combination analyzers: N9913/14/15/16/17/18/50/51/52/53B
- FieldFox signal analyzers: N9933/34/35/36/37/38/60/61/62/63B
The two FieldFox units used in ERTA do not have to be the same model.
- ERTA requires the following options on Combo FieldFox models
(N9913/14/15/16/17/18/50/51/52/53B):
- Option 210, VNA transmission/reflection
- Option 233, spectrum analyzer
ERTA requires the following options on SA FieldFox models (N9933/34/35/36/37/38/60/61/62/63B)
- Option 220, tracking generator
Both FieldFox units (the one used as the source, and the other used as the receiver) must have
the options listed above. The ERTA option (209) cannot be installed unless 210 and 233 are
present on a combo analyzer; or 220 is present on a SA analyzer.
With either the Combo or SA FieldFox units, the following options are highly recommended:
- Option 235, preamplifier – this option increases the measurement dynamic range by
increasing the received signal power
- Option 307, GPS receiver – this option increases the dynamic range by increasing the
frequency accuracy and permitting the use of a narrower RBW
B. Power splitter, two-resistor model, Keysight 11667A, 11667B, or 11667C. Other power splitters
can be used but the specifications listed are based on the match and tracking performance of
11667A, 11667B, or 11667C. Three-resistor power splitters are not recommended.
C. N9910X-712, Trigger/Reference-in cable, SMA (m) to BNC(f), 1 m, quantity two
D. N9910X-713, Trigger/Reference-out cable, SMB (m) to BNC (m), 1 m, quantity two
E. LAN connection – For ERTA, the two FieldFox units communicate via a LAN connection. For a
direct connection, a LAN cable is required. Or, both analyzers can be on a local area network.
F. N9910X-825, GPS Antenna. Necessary if Option 307 is ordered.

Find us at www.keysight.com Page 8
10. What is included with Option
355?
FieldFox analog demodulation has two parts: (1) Tune and listen, and (2) AM/FM metrics. Tune
and listen is available with the purchase of the spectrum analyzer option 233. AM/FM metrics
becomes available when Option 355 is purchased. AM/FM metrics provides the user with RF
spectrum view, demodulated baseband signal waveform, carrier power, frequency deviation,
SINAD and more.
11. What is included with Option
350?
Real-time spectrum analyzer (RTSA) or Option 350 provides real-time measurements. The
FieldFox must be equipped with spectrum analysis capability. The preamplifier option is
recommended, as elusive signals often have low power levels. The real-time bandwidth options
include 10 MHz (standard), 40 MHz (Option B04), or 120 MHz (Option B10). RTSA includes trace
recording and playback capabilities. It does not include a frequency-mask trigger (FMT).
12. Is Spectrum Analyzer Trace
Recording and Playback
standard or an option?
Spectrum Analyzer mode (Option 233) does not include Trace Recording and Playback by default.
To obtain this capability in SA mode, Option 236 Interference Analyzer and Spectrogram needs to
be purchased.
RTSA mode (Option 350) does include Trace Recording and Playback by default in RTSA mode.
Purchasing RTSA mode (Option 350) does not enable Trace Recording and Playback in SA mode
(Option 233).
Trace record/playback features
SA mode
SA & Interference Analyzer
Options 233 and 236
RTSA mode
RTSA
Option 350
Record and playback spectrum traces
Save trace data with GPS time stamp over time
Record and playback spectrogram data
13. What are the requirements for
Noise figure (NF) Option 356?
Requires spectrum analyzer mode (Option 233 on combination models), internal preamplifier
(Option 235) and DC bias variable voltage source (Option 309). An external noise source is also
required and FieldFox supports Keysight noise source models 346A/B/C/K40/K01. Also
recommended to improve accuracy is an external preamplifier Keysight models U7227A/C/F or
U7228A/C/F. Requires accessory item N9910X-713 BNC to SMB cable for DC bias variable
voltage source to noise source connection.
14. What is required for phased array
antenna support (Option 360)
and 5GTF over-the-air (OTA)
measurements (Option 377)?
Requires spectrum analyzer mode (Option 233 on combination models) and GPS receiver (Option
307). Highly recommend internal preamplifier (Option 235). N991x/3xB (x>5) models require
external mixer since phased array antenna and 5GTF operates at 28 GHz. See FAQ #16 for more
OML mixer information. No external mixer required for N995x/6xB models.
15. What is included with indoor and
outdoor mapping (Option 352)?
The FieldFox mapping function is available in the following modes: Channel Scanner (312),
Phased-Array Antenna (360), and OTA LTE (370), OTA 5G TF (377), OTA 5G NR (378). Mapping
is currently not available in SA or RTSA modes. Outdoor mapping requires the availability of GPS
(Option 307). Maps can be saved to the FieldFox internal memory, SD card or USB drive. Using a
direct wired LAN connection, FieldFox will automatically access OpenStreetMap (OSM) once
location coordinates (latitude and longitude) and zoom levels have been entered the Map Explorer
menu. If using the l FieldFox Map Support Tool , OSM map files can be downloaded to a .zip
file and imported to FieldFox internal memory. If the FieldFox GPS receiver is enabled and OSM
maps have been previously saved to FieldFox with those GPS coordinates, FieldFox can
automatically load the corresponding map to match the current GPS coordinates.
16. What is required for EMF
measurements (Option 358)?
Requires triaxial antenna. Supported antenna is AGOS advanced technologies Triaxial Isotropic
Antenna model SDIA-6000 30 MHz to 6 GHz. It can also be ordered as Keysight 85572A-006.
EMF measurements are supported with spectrum analyzer mode (Option 233 on combination
models) and OTA 5G NR (Option 378).
RTSA trace recordings can be recalled and played back in SA mode Spectrogram. This has the added benefit that the
measurements ar e s how n ‘ s lo w er’ , m ak i ng it eas i er fo r th e h um an ey e t o d e ci p her th e s ign a l c ont ent .

Find us at www.keysight.com Page 9
17. What is required for N6820ES
Surveyor 4D Software?
Surveyor 4D software connected to FieldFox spectrum analyzer mode offers a versatile, truly
portable spectrum monitoring system that covers VLF to 50 GHz, including 5G millimeter wave
bands. The software runs on an external PC or tablet. FieldFox required options include spectrum
analyzer mode (Option 233 on combination models), preamplifier (Option 235) and built-in GPS
receiver (Option 307). Core Surveyor 4D software for Windows (Option N6820ES-114) is required
to run the Surveyor 4D software. Other Surveyor 4D software optional licenses that are supported
include basic modulation recognition application (N6820ES-MR1) and universal signal detection
(N6820ES-USD). Requires Surveyor 4D software version 4.3 or later (May 2019). Frequencies
above 26.5 GHz will require external mixer for N991x/3xB (x>5) models. For external mixer
information, FAQ #18. N995x/6xB models eliminate the external mixer requirement.
18. What is required for 5G NR over-
the-air (OTA) measurements
(Option 378)?
Requires spectrum analyzer mode (Option 233 on combination models), 120 MHz analysis
bandwidth (Option B10) and GPS receiver (Option 307). Highly recommend internal preamplifier
(Option 235). FR2 frequencies above 26.5 GHz will require external mixer for N991x/3xB (x>5)
models. N995x/6xB models eliminate the external mixer requirements. For Keysight direct sales,
mixer is orderable as Keysight model N9910XM28-H2A for 3.5 mm test ports or N99010xM28-H2N
for type N test ports. For indirect sales, the mixer is orderable as OML Inc. model M28H2ADC-K,
please see website www.omlinc.com for more information or contact a Keysight representative.
OML mixer RF input interface is 2.92 mm (f). See Page 22 “Accessories” section for other supported
OML mixers and OML frequency extender module adapter kits.
Keysight model: N9910XM28-H2A/N9910XM28-H2N or OML model: M28H2ADC-K
Supported on FieldFox models:
N9916B, N9917B, N9918B, N9936B, N9937B, N9938B
IF output frequency range
Conversion factor IF = 1 GHz
(Includes internal IF amplifier)
Figure 1. OML external mixer diagram
OML mixer DC +5V SMB (m) to
FieldFox USB port +5V
OML mixer LO Input (Port 1) SMA (f) to
FieldFox RF Output (Port 1) 3.5 mm (m)
OML mixer IF Output (Port 2) SMA (f) to
FieldFox RF Input (Port 2) 3.5 mm (m)
OML mixer RF Input 24 to 40 GHz 2.92 mm (f)

Find us at www.keysight.com Page 10
ERTA System Typical Configuration
Combo analyzer: Required Options 210, 233. Recommended: 235, 307
SA analyzer: Required: Option 220. Recommended: 235, 307
11667A (Type-N) or 11667B (3.5 mm)
Type-N(m) to Type-N(m) adapter
N9910X-850 (for use with 11667A or Type-N systems)
N9910X-712, SMA(m) to BNC(f)
N9910X-713, SMB(m) to BNC(m)
2 of each
Total of 4 cables
Connecting FieldFox source port 1 to power splitter input
Connecting power splitter output arm to FieldFox port 2
RF jumper cable or adapter
Power splitter output arm to DUT input
RF jumper cable or adapter
DUT output to FieldFox receiver port 2
LAN cable to connect two FieldFox units directly, or the analyzers must be on
the LAN
GPS antenna, recommended. Necessary if Option 307 is ordered.
Figure 2. ERTA system diagram
The trigger cables and LAN cables must be at least as long as the separation distance between the two ends of the
DUT.

Find us at www.keysight.com Page 11
FAQs – Applicable to all FieldFox RF and Microwave Analyzers
A. What USB power sensors work
with Option 302?
All Keysight U2000x Series USB power sensors are supported with FieldFox.
Visit: www.keysight.com/find/fieldfoxsupport for an up-to-date listing.
B. What is the difference between
USB power sensor (Option 302)
and built-in power meter (Option
310)?
Option 302
USB power sensor
Option 310
Built-in power meter (or channel power meter)
Option 302 allows users to
connect a USB power
sensor to FieldFox's USB
port and make broadband
power measurements
Option 310 is a channelized power measurement
capability built into FieldFox analyzers. Maximum
bandwidth is 100 MHz.
External hardware
USB power sensor
required
None. Uses internal receiver.
Broadband diode detector
measures all frequencies
Tuned receiver, so measures frequencies within defined
channel bandwidth
Frequency range of the analyzer
Set CW frequency, set channel width/span
Depends on channel width and attenuator setting
30 minutes to meet
accuracy specifications
InstAlign accuracy: ± 0.5 dB typical for a CW signal.
Since the measurement is within a certain frequency
channel or bandwidth, to make an accurate
measurement, the user needs to know the exact center
frequency and the signal's bandwidth and set those
accurately.
The power sensor can
easily be moved to the
measurement point, with a
USB cable connecting the
detector to FieldFox.
The measurement point needs to be connected to
FieldFox's RF input port. If an RF jumper cable is used,
the user needs to account for the loss of the cable with
an offset value (can be entered into the analyzer).
Yes, on/off, and nominal
power level control
No access to FieldFox's source from the built-in power
meter mode

Find us at www.keysight.com Page 12
C. What do I need to get GPS
information?
1. The recommended GPS solution is to order:
- Option 307 - built-in GPS receiver
- A GPS antenna such as N9910X-825
- Other GPS antennas can also be used
- The connector for GPS antenna on the instrument is SMA (f)
2. Alternatively, you can purchase a USB-based GPS receiver. You do not need to purchase any
FieldFox options for the USB-based GPS to work. However, the USB-based GPS only provides
time and location data, and time synchronization capability. It cannot be used to increase the
frequency accuracy of the instrument.
D. What is the connector for
Option 309, DC output?
The DC output has a SMB (m) connector. Recommend ordering N9910X Option 713 bias-tee power
cable SMB (f) to BNC (m).
E. What are the connectors for the
Reference/Trigger In and
Reference/ Trigger Out?
The connector for the Ref/Trig In is SMA (f). Recommend ordering N9910X Option 712 Trig/Ref in
SMA (m) to BNC (f) cable.
The connector for the Ref/Trig Out is SMB (m). Recommend ordering N9910X Option 713 bias-tee
power cable SMB (f) to BNC (m).
F. What is Option 030 remote
control capability?
1. Option 030 provides a license for FieldFox to allow remote control via an iOS device.
2. Not supplied by user, but necessary for operation of Option 030 are:
- iOS device: iPad, iPhone, or iPod Touch with iOS 6.1 or higher with free FieldFox app
- A Wi-Fi or 3G/4G network connection between FieldFox and iOS device
G. What USB sensor is required
for Option 330?
Option 330 or pulse measurements requires Option 302 and a Keysight USB peak power sensor. Visit
www.keysight.com/find/usbsensorsforfieldfox for a list of supported peak power sensors. Average
power sensors cannot be used with Option 330, only peak power sensors. The peak power sensor
needs to be purchased separately.
H. What measurement capabilities
are included with Option 330?
Average power, peak power, and peak to average ratio
Analog gauge display and digital display, dBm and watts
Relative/absolute measurements, dB or %, minimum and maximum limits
Trace graph for pulse profiling with gating
Rise time, fall time, pulse width, pulse period, pulse repetition frequency
I. What is included with Option
208?
Option 302, USB power sensor measurements, includes CW power measurements (one frequency at
a time). With Option 208 added, you can make swept-frequency power measurements. You can plot
source power, gain, and receive power versus frequency. Additionally, the source frequency can be
offset from the receiver frequency. The power sensor needs to be purchased separately.

Find us at www.keysight.com Page 13
FieldFox Signal Analyzers
Analyzer models
Step 1. Select the model that provides the desired frequency range.
4 GHz FieldFox signal analyzer
6.5 GHz FieldFox signal analyzer
9 GHz FieldFox signal analyzer
14 GHz FieldFox signal analyzer
18 GHz FieldFox signal analyzer
26.5 GHz FieldFox signal analyzer
32 GHz FieldFox signal analyzer
44 GHz FieldFox signal analyzer
50 GHz FieldFox signal analyzer
54 GHz FieldFox signal analyzer
Analyzer options
Step 2. Select optional measurement capabilities.
You can also add any of these options as a software upgrade in the future.
Prerequisite options/notes
Only available on N9938B. Option 100 is only available at time of
purchase. It is not available as an upgrade.
Extended range transmission analysis (ERTA)
Requires 220. Recommend 307. Requires two FieldFox units.
See FAQ # 9. See page 10 for typical configuration.
Full-band tracking generator
CW, CW coupled, and tracking
Interference analyzer and spectrogram
Spectrum analyzer time gating
Reflection measurements (Return Loss,
VSWR and Scalar)
320 requires 220 on all models. On N9938B, 320 also requires 100.
350
Real-time spectrum analyzer (RTSA)
Recommend 235. See FAQ # 11
Indoor and outdoor mapping
Requires 307, and at least one of 312, 360, 370, 377 or 378.
See FAQ #15
Requires 235, 309 and accessory item N9910X-713 BNC to SMB cable.
See FAQ #13 for external preamplifier and noise source requirements.
Requires triaxial antenna. See FAQ #16
Phased array antenna support
N991x/3xB (x>5) models require an external mixer. See FAQ #14. No
external mixer required for N995x/6xB models.
Over-the-air (OTA) LTE FDD
Requires 307, recommend 235.
Order Option 100 for 3.5 mm (m) test port connectors. With N9938B-100, the spectrum analyzer is built with 3.5 mm
test port connectors instead of the standard Type-N (f). Option 100 is a prerequisite for Option 320 for N9938B.

Find us at www.keysight.com Page 14
Prerequisite options/notes
Over-the-air (OTA) LTE TDD
Requires 307, recommend 235.
Requires 307, recommend 235. N991x/3xB (x>5) models require an
external mixer. See FAQ #14. No external mixer required for N995x/6xB
models.
Requires B10 and 307. Recommend 235. N991x/3xB (x>5) models with
FR2 frequencies above 26.5 GHz require external mixer. See FAQ #18.
No external mixer required for N995x/6xB models.
Analysis bandwidth, 40 MHz1
Recommend 350, 351 or 89600 VSA software.
Analysis bandwidth, 120 MHz1
Recommend 350, 351, 378 or 89600 VSA software.
USB power sensor meas. versus frequency
Need to order USB power sensor 2. See FAQ A
No power sensor required. See FAQ B
Pulse meas. with USB peak power sensor
Requires 302 and USB peak power sensor. See FAQ G and FAQ H
Reflection measurements (Return Loss,
VSWR and Scalar)
Requires 220 on all models. On N9938B specifically, also requires 100.
Remote control capability
Need to order GPS antenna, N9910X-825. See FAQ C
DC bias variable-voltage source
Recommend N9910X-713 cable, See FAQ D
Frequency extender support
Optional 350, 351, 360, 370, 377, 378, PathWave VSA software. See
Accessories, page 22
PathWave VSA (89600 VSA) software
Requires 235 and 307, see page 9, FAQ #17
FieldFox Signal Analyzer FAQs
1. What is included with the basic signal
analyzer?
Basic spectrum analysis, four traces, different detector types, radio standard selection,
limit lines
Channel power, occupied bandwidth, adjacent channel power, spectrum emission mask
AM/FM tune and listen, field strength measurements, antenna factors, frequency counter
marker
2. What is included with Option 236?
Interference analyzer and spectrogram
Trace playback and recording
3. What is included with Option 320?
Normalization using data/memory
4. What is the difference between Option 320
and the CAT mode on the combo base model?
Option 320 on the N993x/6xB SA offers RL and VSWR. CAT mode on the N991x/5x
combo analyzers offer RL and VSWR, DTF, insertion loss, and various calibration
capabilities such as OSL.
5. What is included with Option 355?
FieldFox analog demodulation has two parts: (1) Tune and listen, and (2) AM/FM
metrics. Tune and listen are available as a standard feature on all N993x/6x FieldFox
spectrum analyzers. AM/FM metrics becomes available when Option 355 is purchased.
AM/FM metrics provides the user with RF spectrum view, demodulated baseband signal
waveform, carrier power, frequency deviation, SINAD and more.
FAQs on pages 11 and 12 apply to all FieldFox models.
List of compatible sensors available from www.keysight.com/find/fieldfoxsupport

Find us at www.keysight.com Page 15
Upgrades
Information on upgrades is available from: www.keysight.com/find/fieldfoxsupport
FieldFox RFand Microwave (combination) Analyzer Upgrades
N9913BU, N9914BU, N9915BU, N9916BU, N9917BU, N9918BU,
N9950BU, N9951BU, N9952BU, N9953BU
Requires 210, recommend 211
Remote control capability
USB power sensor measurements versus
frequency
Extended range transmission analysis (ERTA)
Requires 233 and 2101, recommend 307
VNA transmission and reflection
VNA full 2-port S-parameters
Interference analyzer and spectrogram
Spectrum analyzer time gating
External USB power sensor support
Requires 210 and 211 for full VVM functionality
DC bias variable-voltage source
Recommend N9910X-713 cable
Requires 302 and USB peak power sensor
Real-time spectrum analyzer (RTSA)
Requires 233, recommend 235
Indoor and outdoor mapping
Requires 233, 307, and at least one of 312, 360,
370, 377 or 378.
Requires 233, 235, 309 and accessory cable
N9910X-713
Requires 233. Also requires triaxial antenna. See
FAQ #16
Phased array antenna support 2
Over-the-air (OTA) LTE FDD
Requires 233 and 307, recommend 235
Over-the-air (OTA) LTE TDD
Requires 233 and 307, recommend 235
Over-the-air (OTA) 5G TF3
Requires 233 and 307, recommend 235
Option 209 is a system based on two FieldFox units. See FAQ #9, for a detailed description of the system
requirements.
See FAQ #13 for external preamplifier and noise source requirements.

Find us at www.keysight.com Page 16
Requires 233, B10, and 307, recommend 235;
N991x/3xB models with FR2 frequencies above 26.5
GHz require external mixer. See FAQ #18
Analysis bandwidth, 40 MHz4
Requires 233. Recommend 350, 351 or 89600 VSA
software.
Analysis bandwidth, 120 MHz4
Requires 233. Recommend 350, 351, 378 or 89600
VSA software.
FieldFox Signal Analyzer Upgrades
N9933BU, N9934BU, N9935BU, N9936BU, N9937BU, N9938BU, N9960BU, N9961BU, N9962BU,
N9963BU
Remote control capability
USB power sensor measurements versus
frequency
Extended range transmission analysis (ERTA)
Requires 2205, recommend 307
Full-band tracking generator
Interference analyzer and spectrogram
Spectrum analyzer time gating
External USB power sensor support
DC bias variable-voltage source
Recommend N9910X-713 cable
Reflection measurements (Return Loss, VSWR
and Scalar)
Option 220 for all models
Option 100 and 220 for N9938B
Requires 302 and USB peak power sensor
Real-time spectrum analyzer (RTSA)
Indoor and outdoor mapping
Requires 307, and at least one of 312, 360,
370, 377 or 378.
Requires 235, 309 and accessory cable
N9910X-713
Requires triaxial antenna. See FAQ #16
Phased array antenna support 3
External mixer for RF/µwave models
Over-the-Air (OTA) LTE FDD
Requires 307, recommend 235
Over-the-Air (OTA) LTE TDD
Requires 307, recommend 235
Over-the-Air (OTA) 5G TF 3
Requires 307, recommend 235
Requires B10 and 307, recommend 235.
FR/µwave models with FR2 frequencies
above 26.5 GHz require external mixer.
See FAQ #18

Find us at www.keysight.com Page 17
Analysis bandwidth, 40 MHz 4
Recommend 350, 351 or 89600 VSA
software.
Analysis bandwidth, 120 MHz 4
Recommend 350, 351, 378 or 89600 VSA
software.
For N9938B, Option 320 is only available as a software upgrade if the spectrum analyzer is already equipped with
Option 100, within is 3.5 connectors on the test port. Option 100 must have been ordered at the time of original
purchase. It cannot be added later.
2 See FAQ #13 for external preamplifier and noise source requirements.
3 Requires external mixer for N991x/3xB (x>5) models. See FAQ #14. No external mixer required for N995x/6xB.
4 10 MHz standard.
5 Option 209 is a system based on two FieldFox units. See FAQ #9 for the detailed system requirements description

Find us at www.keysight.com Page 18
Documentation
By default, a printed copy of the User’s Guide is not included in FieldFox orders. If you wish to receive the printed User’s Guide,
please order N99xxB Option ABA.
Do not include User's Guide
Printed User's Guide in English
The latest FieldFox User’s Guide (manual) is available online from: www.keysight.com/find/fieldfoxsupport
The Service Guide, SCPI Programming Guide, Quick Reference Guide, and Data Link software help file can also be found via
the website above.
Calibration Kits
FieldFox analyzers support most standard HP/Agilent/Keysight mechanical calibration kits and all Keysight USB ECal modules.
Component list shows calibration components, some calibration kits also include adaptors. Custom calibration kits can be
created and uploaded to FieldFox using Data Link software.
Open, short, load (all male)
Open, short, load (all female)
Open, short, load (both female and male)
Open, short, load (all male)
Open, short, load (all female)
Open, short, load (all male)
Open, short, load, thru (all male)
Open, short, load, thru (all female)
Open, short, load (both female and male)
Open, short, load, thru (all male)
Open, short, load, thru (all female)
Open, short, load, thru (female and male)
Open, short, fixed load, sliding load
(female and male)
300 kHz to 18 GHz
or DC to 18 GHz
Connectors configurable
N7550A
This calibration kit is not eligible for annual re-calibration. There are also no data report calibrations (UK6, 1A7 and
A6J). If annual calibration is required, please order 85514A or 85515A.

Find us at www.keysight.com Page 19
Open, short, load (both female and male)
Open, short, load, all male
Open, short, load, thru (all male)
Open, short, load, thru (all female)
Open, short, fixed load (both female and
male)
Open, short, fixed load (both female and
male)
Open, short, fixed load, sliding load (both
female and male)
Open, short, fixed load (both female and
male), two-line lengths
300 kHz to 26.5 GHz
or DC to 26.5 GHz
Connectors configurable
N7550A
2.92 mm (same as K connector)
Open, short, fixed load, thru (all female)
Open, short, fixed load, thru (all male)
Open, short, fixed load, sliding load (both
female and male)
Open, short, fixed load (female and male)
Open, short, fixed load (all female)
Open, short, fixed load (all male)
Open, short, fixed load (female and male)
Open, short, load, fixed load, sliding load
(both female and male)
R eco mme n d o rde ri n g q u an tit y 2 of N99 10X Op tio n 8 4 6, 50 to 7 5 Ω a d apt er .
S ame as Mau ry ’ s 8 770 C47
S ame as Mau ry ’ s 8 770 D47

Find us at www.keysight.com Page 20
Short, termination, offset length
Short, termination, offset length
Short, termination, offset length
Short, termination, offset length
Short, shim, termination, standard section
Short, shim, termination, standard section
Short, shim, termination, standard section
All cables listed below are rugged phase-stable cables.
USB preamplifier, 10MHz to 4 GHz
www.keysight.com/find/U7227A
USB preamplifier, 100MHz to 26.5 GHz
www.keysight.com/find/U722CA
USB preamplifier, 2 to 50 GHz
www.keysight.com/find/U7227F
USB preamplifier, 10MHz to 4 GHz
www.keysight.com/find/U7228A
USB preamplifier, 100MHz to 26.5 GHz
www.keysight.com/find/U7228C
USB preamplifier, 2 to 50 GHz
www.keysight.com/find/U7228F

Find us at www.keysight.com Page 21
346 Series noise source family
www.keysight.com/find/346noisesources
Antenna, directional, multiband, 800 to 2500 MHz, 10 dBi, Type-N (f)
Antenna, telescopic whip, 70 MHz to 1 GHz, BNC (m)
Antenna, directional, log periodic, 600 MHz to 9 GHz, Type-N (f)
Antenna, cellular narrowband, 824 to 869 MHz, Type-N (f)
Antenna, cellular narrowband, PCS 1850 to 1990 MHz, Type-N (f)
Antenna, GPS, active, SMA (m)
5G Phased Array Antenna 28 GHz
Triaxial Isotropic Antenna 30 MHz to 6 GHz
RF and microwave adaptors
Coaxial adapter, 3.5 mm (m) to 3.5 mm (m), 26.5 GHz
Coaxial adapter, 3.5 mm (f) to 3.5 mm (f), 26.5 GHz
Coaxial adapter, 3.5 mm (m) to 3.5 mm (f), 26.5 GHz
Coaxial adapter, NMD 2.4 mm (f) to Type-N (f), 50-ohm, 18 GHz
Coaxial adapter, NMD 2.4 mm (f) to 2.92 mm/K (f), 40 GHz
Coaxial adapter, NMD 2.4 mm (f) to 3.5 mm (f), 26.5 GHz
3.5 mm NMD (f) to 3.5 mm (f) adapter, 26.5 GHz
3.5 mm NMD (f) to Type-N (f) adapter, 18 GHz
Coaxial adapter, Type-N (m) to 7/16 DIN (f)
Adapter kit: Type-N (f) to 7/16 DIN (f), Type-N (f) to 7/16 DIN (m), Type-N (f) to Type-N (f)
Coaxial adapter, Type-N (m) 50 ohm to Type-N (f) 75 ohm
Adapter kit: Type-N (f) to TNC (m) adapter, Type-N (f) to TNC (f) adapter, 11 GHz
Coaxial adapter, Type-N (f) to 3.5 mm (f), 18 GHz
Coaxial adapter, Type-N (f) to 3.5 mm (m), 18 GHz
Coaxial adapter, Type-N (m) to Type-N (m), 18 GHz
Coaxial adapter, Type-N (f) to Type-N (f), 18 GHz
Coaxial adapter, Type-N (m) to Type-N (f), 18 GHz
Coaxial adapter, 2.4 mm (f) to 2.4 mm (f), 50 GHz
Coaxial adapter, 2.4 mm (f) to 2.92 mm/K (f), 40 GHz
Currently is not RoHS-compliant.

Find us at www.keysight.com Page 22
OML frequency extender modules
Purchase OML frequency extenders directly from OML, Inc. One mixer, OML model number M28H2ADC-K (24 to 40 GHz), has been set up
as a Keysight special handling part number N9910XM28-H2A or N9910XM28-H2N and is available for sale directly through Keysight. Contact
OML, Inc. directly (www.omlinc.com) for pricing, ordering and datasheet information or contact a Keysight representative for assistance.
FieldFox operating modes that support frequency extenders include: Spectrum analyzer, real-time spectrum analyzer, I/Q analyzer, overthe-air (5G NR, LTE FDD, 5GTF), phased array antenna support and PathWave vector signal analysis software (formerly 89600 VSA).
OML mixer frequency range
Frequency range with FieldFox
models N9918/38B and N9917B/37B
Frequency range with FieldFox
models N9916/36B
OML frequency extender module adapter kits
OML frequency extender module adapter kits make for easier connection to FieldFox units with N-Type or 3.5 mm. Frequency extender
adaptors work with OML frequency extender model number M28H2ADC-K (24 to 40 GHz), or Keysight special handling part number
N9910XM28-H2A that is available for sale directly through Keysight. Alternatively, Keysight also offers a special handling part number
N9910M28-H2A that has Type-N (m) connectors for LO input and IF output. Users can connect the frequency extender directly to the
FieldFox analyzer with Type-N test ports eliminating the need for adapters. Please see N9910M28 web page for more detailed information.
When ordering the OML frequency extender as Keysight model number N9910XM28-H2A, add the adapter kits shown below as Keysight
model numbers N9910M28 -AK4 and -AK5. Note: -AK1, -AK2, -AK3 are intended for N9910XM28-H2A only.
Coaxial straight Male-N to Male-SMA, Qty 2 included, connects mixer directly to FieldFox with N-Type
ports
Coaxial straight Female-SMA to Female-N, Qty 2 included, spacer for FieldFox units with 3.5 mm ports
and used with N9910XM28-AK1 when GPS antenna is mounted vertically
Coaxial straight Male-SMA to Female-SMA, Qty 2 included, connects mixer directly to FieldFox with 3.5
mm ports
Female-SMA to Male-SMA, Right Angle, Qty 1, included for connecting GPS antenna at right angle and
used for GPS antenna attachment with N9910XM28-AK1 or N9910XM28-AK3 adapter kits. Can also be
used to provide a right-angle connection to Ref/Trig input.
Waveguide horn antenna and mounting fixture
When ordering the OML frequency extender adapter kits separately (not added to an order with Keysight model number N9910XM28-H2A
or N9910XM28-H2N), order the adapter kits shown above (N9910M28-AKx) as the Keysight part numbers shown below.
Coaxial straight Male-N to Male-SMA, order Qty 2, connects mixer directly to FieldFox with N-Type ports
Coaxial straight Female-SMA to Female-N, order Qty 2, spacer for FieldFox units with 3.5 mm ports and
used with (part number 1250-1636 adapter kit shown above) when GPS antenna is mounted vertically
Coaxial straight Male-SMA to Female-SMA, order Qty 2, connects mixer directly to FieldFox with 3.5 mm
ports
Female-SMA to Male-SMA, Right Angle, Qty 1, for connecting GPS antenna at right angle and used for
GPS antenna attachment with (part number 1250-1636 or 1250-3851 adapter kits shown above)
Antenna and mounting fixture, 0.75-inch square flange plastic, Qty 1 included, to be used with 0955-3591
below
Waveguide horn antenna, pyramidal Ka-band 26.5 to 40 GHz WR-28, Qty 1 included, also order 09506352 above for mounting fixture

Find us at www.keysight.com Page 23
Other RF and microwave accessories
Fixed attenuator, 40 dB, 100 W, DC to 3 GHz, Type-N (m) to Type-N (f)
Fixed attenuator, 40 dB, 50 W, DC to 8.5 GHz, Type-N (m) to Type-N (f)
External bias-tee, 2.5 MHz to 6 GHz, 1 W, 0.5 A
Torque wrench, 17 mm, 90 N-cm, 8 in-lb.
Trig/Ref in Cable SMA (m) to BNC (f), 1 m or 3.28 ft
Bias-tee power cable SMB (f) to BNC (m), 1 m or 3.28 ft
Other FieldFox accessories
Extra high capacity battery
DC car charger and adapter
Extra soft carrying case with backpack and shoulder strap
Also recommend ordering N9910X-713 Bias-Tee Power Cable, SMB(f) to BNC(m), 3.28 ft., to connect to the FieldFox
DC source.

Find us at www.keysight.com Page 24
N9910X-701
Type-N (m) to Type-N
(m) cable, 3.28 ft
N9910X-812
Type-N (m) to Type-N (m)
cable, 12 ft
N9910X-708
3.5 mm (m) to 3.5
mm (f) cable, 3.28 ft
N9910X-816
Type-N (m) to Type-N (f)
cable, 3.28 ft
N9910X-820
Antenna, directional
N9910X-821
Antenna, telescopic
whip ™
N9910XA-823
Antenna, cellular
narrowband
N9910X-848
Coaxial adapter, Type-N(f)
to 3.5 mm (f)
N9910X-822
Antenna, directional
N9910X-875
DC car charger and adapter
N9910X-825
Antenna, GPS, active
N9910X-876
Extra high capacity
battery
N9910X-874
External bias-tee
N9910X-872
External battery
charger
N4690B
2-port ECal, Type-N,
18 GHz
N9910X-881
Hard transit case
N9910X-800
3-in-1 OSL cal kit, Type-N
(m), 6 GHz
N9910X-811
Type-N (m) to Type-N
(f) cable, 5 ft
N991X0-801
3-in-1 OSL cal kit, Type-N
(f), 6 GHz

Find us at www.keysight.com Page 25
85514A
4-in-1 OSLT cal kit,
Type-N (m)
9 GHz
85520A
4-in-1 OSLT cal kit, 3.5 mm
(m), 26.5 GHz
85515A
4-in-1 OSLT cal kit,
Type-N (f),
9 GHz
85521A
4-in-1 OSLT cal kit, 3.5 mm
(f), 26.5 GHz
85518A
4-in-1 OSLT cal kit,
Type-N (m), 18 GHz
85033D/E
3.5 mm cal kit, 9 GHz
85519A
4-in-1 OSLT cal kit,
Type-N (f),
18 GHz
85052D
3.5 mm cal kit, 26.5 GHz
85054D
Economy cal kit,
Type-N, 18 GHz
85571A-0281
5G Phased Array Antenna
28 GHz
85572A-006 Triaxial
Isotropic Antenna (30
MHz to 6 GHz)
85056D
2.4 mm cal kit, 50 GHz
This product is currently not RoHS-compliant.

Find us at www.keysight.com Page 26
N9911X211/212/213/214 WR90 economical cal kit
N4691B
3.5 mm, 2-port ECal,
26.5 GHz
N4692A
2.92 mm, 2-port ECal,
40 GHz
N4693A
2.4 mm 2-port ECal,
50 GHz
X11644A
WR-90 standard cal
kit
Learn more at: www.keysight.com
For more information on Keysight Technologies’ products, applications, or services,
please contact your local Keysight office. The complete list is available at:
www.keysight.com/find/contactus
Thi s info rmatio n is sub ject t o cha nge wi thout notic e. © K eysight T echno logies , 2019 - 2021, Publi shed in USA , March 15, 2021, 59 92-3701EN