PNA Family Network Analyzer Configurations .................................................................................................................................................. 05
Test set and power configuration options ..............................................................................................................................................05
PNA-X Series Test Set and Power Configuration Options ............................................................................................................................... 10
PNA Series Test Set and Power Configuration Options ....................................................................................................................................15
PNA-L Series Test Set and Power Configuration Options ................................................................................................................................ 18
PNA Family Applications and Options ............................................................................................................................................................... 19
PNA Family Network Analyzer Upgrade Kits .................................................................................................................................................... 29
Frequency, test ports, test set and power configurations ....................................................................................................................29
Material measurements ...........................................................................................................................................................................32
Signal integrity measurements ...............................................................................................................................................................32
Test set options ........................................................................................................................................................................................33
Cables and adapter sets ..........................................................................................................................................................................34
For devices with 1.0 mm connectors ......................................................................................................................................................35
For devices with 1.85 mm connectors ....................................................................................................................................................35
For devices with 2.4 mm connectors ......................................................................................................................................................36
For devices with K connectors (2.92 mm) ..............................................................................................................................................37
For devices with 3.5 mm or SMA connectors ........................................................................................................................................39
For devices with Type-N connectors ...................................................................................................................................................... 41
For devices with 7 mm connectors ......................................................................................................................................................... 42
For devices with waveguide ....................................................................................................................................................................42
General Accessories ........................................................................................................................................................................................... 44
Power meters and sensors ..................................................................................................................................................................... 44
This configuration guide describes standard configurations, options, accessories, upgrade kits and compatible peripherals for the PNA
Family microwave network analyzers. This guide should be used with the Keysight Technologies, Inc. PNA Family data sheets for a
complete description of these analyzers.
PNA-X Series
– N5249B 900 Hz/10 MHz to 8.5 GHz
– N5241B 900 Hz/10 MHz to 13.5 GHz
– N5242B 900 Hz/10 MHz to 26.5 GHz
– N5244B 900 Hz/10 MHz to 43.5 GHz
– N5245B 900 Hz/10 MHz to 50 GHz
– N5247B 900 Hz/10 MHz to 67 GHz
PNA Series
– N5221B 900 Hz/10 MHz to 13.5 GHz
– N5222B 900 Hz/10 MHz to 26.5 GHz
– N5224B 900 Hz/10 MHz to 43.5 GHz
– N5225B 900 Hz/10 MHz to 50 GHz
– N5227B 900 Hz/10 MHz to 67 GHz
Find us at www.keysight.com
PNA-L Series
– N5239B 300 kHz to 8.5 GHz
– N5231B 300 kHz to 13.5 GHz
– N5232B 300 kHz to 20 GHz
– N5234B 10 MHz to 43.5 GHz
– N5235B 10 MHz to 50 GHz
Page 3
Keysight Offers the Following Options for All PNA Family Network Analyzers
Certification options
Commercial calibration certification with test data
(Option UK6)
Complete set of measurements which tests unit to
manufacturer’s published specifications. Includes calibration
label, calibration certificate, and data report. Conforms to ISO
9001.
ISO 17025 compliant calibration (Option 1A7)
Complete set of measurements which tests unit to
manufacturer’s published specifications. Includes calibration
label, ISO 17025 calibration certificate, and data report,
measurement uncertainties and guardbands on all customer
specifications. Conforms to ISO 17025 and ISO 9001.
ANSI Z540 compliant calibration (Option A6J)
Complete set of measurements which tests unit to
manufacturer’s published specifications. Includes pre- and
post-adjustment data with measurement uncertainty information
compliant to the ANSI/NCSL Z540 standard.
Documentation
The PNA Series instruments are equipped with an Online Help
system available within the instrument in English only. All PNA
documentation is available on the web:
www.keysight.com/find/pna
Calibration software licenses
Built-in performance test software for standard
compliant cal (S93898A)
Adds built-in performance testing and calibration software
for self-maintainers. Requires additional equipment. See the
analyzer’s Service Guide for more information on equipment
required.
Find us at www.keysight.com
Page 4
PNA Family Network Analyzer Configurations
PNA-X SeriesPNA SeriesPNA-L SeriesTest Port Connector
N5249B 900 Hz/10 MHz to 8.5 GHzN5239B 300 kHz to 8.5 GHz3.5 mm (male)
N5241B 900 Hz/10 MHz to 13.5 GHzN5221B 900 Hz/10 MHz to 13.5 GHzN5231B 300 kHz to 13.5 GHz3.5 mm (male)
N5242B 900 Hz/10 MHz to 26.5 GHzN5222B 900 Hz/10 MHz to 26.5 GHzN5232B 300 kHz to 20 GHz3.5 mm (male)
N5244B 900 Hz/10 MHz to 43.5 GHzN5224B 900 Hz/10 MHz to 43.5 GHzN5234B 10 MHz to 43.5 GHz2.4 mm (male)
N5245B 900 Hz/10 MHz to 50 GHzN5225B 900 Hz/10 MHz to 50 GHzN5235B 10 MHz to 50 GHz2.4 mm (male)
N5247B 900 Hz/10 MHz to 67 GHz N5227B 900 Hz/10 MHz to 67 GHz1.85 mm (male)
Test set and power configuration options
Choose one test set and power configuration option. Option 2xx indicates two test ports. Option 4xx indicates four test ports. To add
options to a product, order the corresponding item number (N52xxB-xxx).
⦁⦁⦁⦁⦁⦁⦁
⦁⦁
⦁⦁⦁⦁Not available on 67 GHz model
⦁⦁⦁⦁⦁
⦁⦁⦁⦁⦁⦁Not available on 67 GHz model
⦁⦁⦁⦁⦁⦁⦁
⦁⦁⦁⦁⦁⦁⦁⦁
PNA Series
Option 200
Option 201⦁
Option 205⦁⦁⦁Only available on N5221/22/27B
Option 2102-port metrology option
Option 217⦁⦁⦁Not available on 67 GHz model
Option 219⦁⦁⦁⦁
Option 220⦁⦁⦁⦁⦁
Option 400
Option 401
1
1
⦁⦁
⦁
Option 405⦁⦁⦁
Option 410
Option 417
Option 419
1
1
1
⦁⦁⦁⦁Not available on 67 GHz model
⦁⦁⦁⦁⦁
⦁4-port metrology option
Option 420⦁⦁⦁⦁⦁⦁
PNA-L Series
Option 200
Option 216⦁⦁
Option 400Available on only N5231/32B
Option 416
1. To independently control the frequency of the second internal source, one of the following soft ware
2. Adds one source at tenuator to be shared with all test ports.
2
applications is required: S93080/029/082/083/084/086/087/089/090x/093/094A, or S94510/511A.
⦁⦁Available on only N5231/32B
Find us at www.keysight.com
Page 5
PNA Family Network Analyzer Configurations (Continued)
PNA-X SeriesPNA SeriesPNA-L SeriesTest Port Connector
N5249B 900 Hz/10 MHz to 8.5 GHzN5239B 300 kHz to 8.5 GHz3.5 mm (male)
N5241B 900 Hz/10 MHz to 13.5 GHzN5221B 900 Hz/10 MHz to 13.5 GHzN5231B 300 kHz to 13.5 GHz3.5 mm (male)
N5242B 900 Hz/10 MHz to 26.5 GHzN5222B 900 Hz/10 MHz to 26.5 GHzN5232B 300 kHz to 20 GHz3.5 mm (male)
N5244B 900 Hz/10 MHz to 43.5 GHzN5224B 900 Hz/10 MHz to 43.5 GHzN5234B 10 MHz to 43.5 GHz2.4 mm (male)
N5245B 900 Hz/10 MHz to 50 GHzN5225B 900 Hz/10 MHz to 50 GHzN5235B 10 MHz to 50 GHz2.4 mm (male)
N5247B 900 Hz/10 MHz to 67 GHz N5227B 900 Hz/10 MHz to 67 GHz1.85 mm (male)
Hardware options
DescriptionFor PNA-X
Series
Add IF inputsN524xB-020N522xB-020N/AUsed for antenna measurements and mm-wave extenders
Add pulse modulator to first sourceN524xB-021N522xB-021N/A
Add pulse modulator to second sourceN524xB-022N522xB-022N/ARequires one of Option 222, 224, 4xx
Add low-noise receiverN524xB-029N/AN/AS93029A application sof tware is needed to control
For PNA
Series
For PNA-L
Series
Additional Information
the noise receiver for noise figure and noise power
measurements. For N5241/42/49B, requires one of
options 21x, 22x, 41x, or 42x. For N5244/45/47B,
requires one of options 22x or 42x. On N5247B, noise
receiver works up to 50 GHz only.
Find us at www.keysight.com
Page 6
PNA Family Network Analyzer Configurations (Continued)
PNA-X SeriesPNA SeriesPNA-L SeriesTest Port Connector
N5249B 900 Hz/10 MHz to 8.5 GHzN5239B 300 kHz to 8.5 GHz3.5 mm (male)
N5241B 900 Hz/10 MHz to 13.5 GHzN5221B 900 Hz/10 MHz to 13.5 GHzN5231B 300 kHz to 13.5 GHz3.5 mm (male)
N5242B 900 Hz/10 MHz to 26.5 GHzN5222B 900 Hz/10 MHz to 26.5 GHzN5232B 300 kHz to 20 GHz3.5 mm (male)
N5244B 900 Hz/10 MHz to 43.5 GHzN5224B 900 Hz/10 MHz to 43.5 GHzN5234B 10 MHz to 43.5 GHz2.4 mm (male)
N5245B 900 Hz/10 MHz to 50 GHzN5225B 900 Hz/10 MHz to 50 GHzN5235B 10 MHz to 50 GHz2.4 mm (male)
N5247B 900 Hz/10 MHz to 67 GHz N5227B 900 Hz/10 MHz to 67 GHz1.85 mm (male)
Application software
1
The S93xxxB software products replace the S93xxxAs, and the S93xxxAs will be discontinued in June 2019.
DescriptionFor PNA-X
Series
For PNA
Series
For PNA-L
Series
Additional Information
Automatic fixture removalS93007B/AS93007B/AS93007B/A
Time domain analysisS93010B/AS93010B/AS93010B/A
Enhanced time domain analysis with
TDR
Real time S-parameter and power
measurement uncertainty
S93011B/AS93011B/AS93011B/AIncludes all capability of S93010B/A
Basic pulsed-RF measurementsS93025B/AS93025B/AN/AIncludes control of internal pulse generators and provides
pulse widths to 200 ns using wideband detection
Advanced pulsed-RF measurementsS93026B/AS93026B/AN/AIncludes all capability of S93025B/A, and provides pulse
widths to 100 ns using wideband detection, and 20 ns using
narrowband detection
Add mechanical noise tuner control for
noise figure/parameter measurements
Noise figure measurements with vector
correction
2
Frequency-offset measurements
S93027B/AN/AN/AProvides ability to control Maury Microwave’s LXI impedance
tuners. Requires application sof tware S93029B/A.
S93029B/AS93029B/AN/AStandard receivers are used if hardware option N524xB-029
is not present
S93080B/AS93080B/AS93080B/A Provides ability to independently set the frequency
of internal sources and receivers, and to configure
external sources. This functionality is included with
S93029/082/083/084/086/087/089/090x/093/094B/A or
S94510/511A.
Scalar mixer/converter measurementsS93082B/AS93082B/AS93082B/AProvides SMC measurement class. S93082B/A is a subset of
S93083B/A
Vector and scalar mixer/converter
measurements
3
S93083B/AS93083B/AN/AProvides SMC+Phase and VMC measurement classes
Embedded-LO capabilityS9 3084B/AS930 8 4B/AN/AWorks with S93029/082/083/086/087B/A
Gain-compression measurementsS93086B/AS9 3086B/AN/A
Intermodulation distortion measurements 4S93087B/AS93087B/AN/ANot available with PNA test set options 200, 210, 400, and 410
Source phase controlS93088B/AS93088B/AN/A
Differential and I/Q device measurementsS93089B/AS93089B/AN/ARequires a 4-port test set option (4xx)
1. The S9xxxxA sof tware license t ypes are fixed-perpetual (1FP), transportable-perpetual (1TP), fixed-1-year (1FY), and transportable-1-year (1TY). The
S93xx xB software has four license types: Node-locked, Transportable, USB Portable and Floating/Network, and has four term choices for each perpetual
and time-based types. Please refer to “Keysight Software Licensing Options, Provide Flexibility and Support ” on page 29 for more details. The fixed-perpetual (1FP) is the only license type that can be ordered as part of the instrument and installed. The other license t ypes must be ordered separately and
installed from the web after the receipt of the instrument.
2. For N522xB and N5241/42/49B, vector-noise-corrected measurements require an ECal for use as an impedance tuner. For N5244/45/47B with Option 029,
an internal tuner is included. Noise calibration requires a power meter when using a standard receiver. When using the low-noise receiver (Option 029),
either a power meter or a 346-series noise source is required (Keysight 346C or 346C-K01 recommended). A power meter is required for measuring mixers
and converters.
3. A configurable test set is required for VMC measurements to connect a reference mixer, or for SMC+Phase measurements using the comb-generator-based
calibration. When ordered with PNA test set Options 200, 210, 400, or 410 (no front-panel jumpers), phase and delay measurements can only by done using
SMC+Phase with a calibration mixer.
4. S93087B/A can be used without PNA-X Options 22x or 42x, but exernal equipment such as a signal generator and a combiner may be required.
Refer to page 20 for more details.
5. S93015B/A is not available on N5231B, N5232B and N5239B.
Find us at www.keysight.com
Page 7
PNA Family Network Analyzer Configurations (Continued)
PNA-X SeriesPNA SeriesPNA-L SeriesTest Port Connector
N5249B 900 Hz/10 MHz to 8.5 GHzN5239B 300 kHz to 8.5 GHz3.5 mm (male)
N5241B 900 Hz/10 MHz to 13.5 GHzN5221B 900 Hz/10 MHz to 13.5 GHzN5231B 300 kHz to 13.5 GHz3.5 mm (male)
N5242B 900 Hz/10 MHz to 26.5 GHzN5222B 900 Hz/10 MHz to 26.5 GHzN5232B 300 kHz to 20 GHz3.5 mm (male)
N5244B 900 Hz/10 MHz to 43.5 GHzN5224B 900 Hz/10 MHz to 43.5 GHzN5234B 10 MHz to 43.5 GHz2.4 mm (male)
N5245B 900 Hz/10 MHz to 50 GHzN5225B 900 Hz/10 MHz to 50 GHzN5235B 10 MHz to 50 GHz2.4 mm (male)
N5247B 900 Hz/10 MHz to 67 GHz N5227B 900 Hz/10 MHz to 67 GHz1.85 mm (male)
Application software 1 (Continued)
The S93xxxB software products replace the S93xxxAs, and the S93xxxAs will be discontinued in June 2019.
DescriptionFor PNA-X
Series
Spectrum analysis, up to 8.5 GHz
Spectrum analysis, up to 13.5 GHz
Spectrum analysis, up to 26.5 GHz
Spectrum analysis, up to 43.5 GHz
Spectrum analysis, up to 50 GHz
Spectrum analysis, up to 67 GHz
Spectrum analysis, up to 90 GHz
Spectrum analysis, up to 120 GHzS93093B/AS93093B/AN/A
Spectrum analysis, beyond 120 GHzS93094 B/AS93094 B/AN/A
Active hot parametersS93110B/AN/AN/ARequires a 4-port test set option (4x x)
Low-frequency extension (LFE) is disabled with Option 425
Active hot parametersS9 3111B/AN/AN/AExport-restricted version for N5247B with maximum operation
to 50 GHz
Requires a 4-port test set Option (4x x)
Low-frequency extension (LFE) is disabled with Option 425
Fast CW measurementsS93118B/AS93118B/AN/A
True-mode stimulusS93460B/AS93460B/AN/ARequires a 4-por t test set option (4xx)
N-port measurements
1. The S9xxxxA sof tware license t ypes are fixed-perpetual (1FP), transportable-perpetual (1TP), fixed-1-year (1FY), and transportable-1-year (1TY). The S93xxxB sof tware
has four license t ypes: Node-locked, Transportable, USB Por table and Floating/Network, and has four term choices for each perpetual and time-based types. Please refer
to “Keysight Sof tware Licensing Options, Provide Flexibility and Support” on page 29 for more details. (Note: S93093B/A, S93094B/A, S93898B/A, S93110B/A, S94510A
and S94511A have fixed-license types only). The fixed-perpetual (1FP) is the only license type that can be ordered as par t of the instrument and installed. The other license
types must be ordered separately and installed from the web af ter the receipt of the instrument.
2. For use with PNA or PNA-X models, a test set with internal receiver at tenuators is recommended to avoid receiver compression when measuring large input signals. For
use with PNA-L models, test set option 216 or 416 is recommended so that external attenuators can be connected via the front-panel jumpers to avoid receiver compression
as needed.
3. When ordering a test set, select an appropriate interface kit. Refer to Multiport Measurements section on page 32 for more details.
4. When N524xB is conf igured as a multiport analyzer using S93551B/A and a multiport test set, the combiner feature of Option 22x or 42x is temporarily disabled.
When configured as a standalone analyzer, the combiner feature is enabled.
5. A fully configured NVNA system requires two comb generators with power supplies, Keysight calibration kits (mechanical or ECal), and a power meter and sensor or USB
power sensor.
6. Pulse capability requires option 021 and S93025B/A or S93026B/A.
7. Pulse capability requires option 021, 022 and S93025B/A or S93026B/A.
8. Requires EXG, MXG, or PSG signal generator for X-parameter extraction (the PNA-X’s 10 MHz reference output can be used for 10 MHz tone-spacing applications).
9. X-parameters is a trademark and registered trademark of Keysight Technologies in the U.S., Europe, Japan, and elsewhere. The X-parameters format and underlying
equations are open and documented. For more information, visit www.keysight.com/find/eesof-x-parameters-info.
10. Currently CW stimulus only.
11. Use of this application will generally require ex ternal sources, couplers attenuators, wafer probe station and more to complete system configuration. Please work with your
local Keysight application engineer for details.
S94522AN/AN/ARequires application software S94510A or S94511A
Find us at www.keysight.com
Page 8
PNA Family Network Analyzer Configurations (Continued)
PNA-X SeriesPNA SeriesPNA-L SeriesTest Port Connector
N5249B 900 Hz/10 MHz to 8.5 GHzN5239B 300 kHz to 8.5 GHz3.5 mm (male)
N5241B 900 Hz/10 MHz to 13.5 GHzN5221B 900 Hz/10 MHz to 13.5 GHzN5231B 300 kHz to 13.5 GHz3.5 mm (male)
N5242B 900 Hz/10 MHz to 26.5 GHzN5222B 900 Hz/10 MHz to 26.5 GHzN5232B 300 kHz to 20 GHz3.5 mm (male)
N5244B 900 Hz/10 MHz to 43.5 GHzN5224B 900 Hz/10 MHz to 43.5 GHzN5234B 10 MHz to 43.5 GHz2.4 mm (male)
N5245B 900 Hz/10 MHz to 50 GHzN5225B 900 Hz/10 MHz to 50 GHzN5235B 10 MHz to 50 GHz2.4 mm (male)
N5247B 900 Hz/10 MHz to 67 GHz N5227B 900 Hz/10 MHz to 67 GHz1.85 mm (male)
Accessories, calibration options
DescriptionFor PNA-X SeriesFor PNA SeriesFor PNA-L SeriesAdditional information
Accessories
Rack mount kit for use without handlesN524x B -1CMN522x B -1CMN523x B -1CM
Rack mount kit for use with handlesN 5 24xB-1C PN522x B -1CPN523 x B -1CP
Pulse I/O adapterN1966AN1966AN/A
Comb generator
Calibration software
Built-in performance test software for standard compliant
calibration
Calibration documentation
ISO 17025 compliant calibrationN524x B-1A 7N522xB-1A7N523 x B -1A7
Commercial calibration certificate with test dataN524xB-UK6N522xB-UK6N523xB-UK6
ANSI Z540 compliant calibrationN524xB-A6JN522xB-A6JN523xB-A6J
1
U9391C/F/GN /AN/A
S93898B/AS93898B/AS93898B/A
2
1. A fully configured NVNA system requires two comb generators with power supplies, Keysight calibration kits
(mechanical or ECal), and a power meter and sensor or USB power sensor.
2. Additional hardware required. Please refer to the analyzer’s service guide for required service-test
equipment.
Find us at www.keysight.com
Page 9
PNA-X Series Test Set and Power Configuration Options
Test port 1
R1
Test port 2
R2
AB
Source 1
OUT 1OUT 2
Pulse
modulator
R A B C D
IF inputs
Rear panel
To receivers
LO
Pulse generators
Standard source
10 MHz - 8.5/13.5/26.5/43.5/50/67.5 GHz
Pulse modulator
R1
A
Test
port
A'
LF source
900 Hz - 100 MHz
R1'
External bias
1
The PNA-X is an integrated vector network analyzer featuring
a built-in S-parameter test set, one or two synthesized sources
used for device stimulus, a solid-state drive, USB interfaces,
and a 12.1” LCD touch screen display. The N5241B, N5242B, and
N5249B have 50 ohm, ruggedized 3.5 mm (m) test ports. The
N5244B and the N5245B have 50 ohm, ruggedized 2.4 mm (m)
test ports. The N5247B has 50 ohm, ruggedized 1.85 mm (m)
test ports. Included with each instrument is a mouse, keyboard
(U.S. style), and one day of on-site productivity assistance
(PS-S20-PNA).
A test set and power configuration option is mandatory, choose
one of the following:
2-ports, single source, with configurable test set
(Option 201)
The standard 2-port test set comes with six front-panel access
loops. The loops provide access to the signal path between (a)
the source output and the reference receiver, (b) the source
output and directional coupler thru arm and (c) the coupled arm
of the directional coupler and the port receiver. The standard test
set also includes a solid-state internal RF bypass switch in the R1
reference-receiver path.
2-ports, single source, with configurable test set
and low frequency extension (Option 205)
Along with 2-port single source with the access loops with
Option 201, Option 205 adds bias tees and additional hardware
to extend the start frequency of the PNA-X down to 900 Hz.
The extended start frequency is available only for the following
measurement classes: standard, gain compression (amplifier and
converters), and for magnitude-only measurements using SMC
(scalar mixer/converter) or SMC+Phase. In the standard channel,
pulsed RF, true-mode stimulus, and source phase control are not
supported for measurements below 10 MHz. The block diagram
below shows how the low-frequency hardware is configured
for one test port; the other test ports are configured similarly.
For test port 1, the combiner and noise tuner (not shown) are
only available for use down to 10 MHz, and for test port 2, the
low-noise receiver (not shown) is only available for use down to
10 MHz.
1. The block diagrams shown above include hardware that must be ordered
as separate options, such as pulse modulators (Options 021 and 022),
and IF access (Option 020), or is controlled by application software, as
is the case for the pulse generators. In addition, the combiner type and
attenuator values vary by model number. Refer to the product data sheet
for the correct block diagram for a specific model.
Find us at www.keysight.com
Page 10
PNA-X Series Test Set and Power Configuration Options 1 (Continued)
R1
Test port 2
R2
A
B
To receivers
LO
Source 2
Output 1
Source 2
Output 2
Pulse generators
Rear panel
1
2
3
4
Test port 1
Source 1
OUT 1OUT 2
Pulse
modulator
Source 2
OUT 1OUT 2
Pulse
modulator
J9J10J11J8J7J2 J1
35 dB
65 dB
35 dB
65 dB
J6 J5
RF
OUT
LO
OUT
RR1 R2A B
IF inputs
Test port 1
R1
Test port 2
R2
35 dB
65 dB
35
dB
65 dB
AB
Source 1
OUT 1OUT 2
Pulse
modulator
R A B C D
IF inputs
Rear panel
To receivers
LO
Pulse generators
Test port 1
R1
Test port 2
R2
35 dB
65 dB
35
dB
65 dB
AB
Source 1
OUT 1OUT 2
Pulse
modulator
R A B C D
IF inputs
Rear panel
To receivers
LO
Pulse generators
2-ports, single source, with extended power
range (Option 217)
This configuration comes with front-panel access loops,
and source and receiver attenuators at each port. The
source attenuators are settable in 5 dB steps up to 65 dB in
N5241/42/49B, and in 10 dB steps up to 60 dB in N5244/45B.
The receiver attenuators are settable in 5 dB steps up to 35
dB. The maximum power rating on the test port couplers is +43
dBm (additional attenuators or isolators are typically required to
protect other components inside the instrument). Option 217 is
not available on the N5247B.
2-ports, dual sources, with extended power
range, combiner, and mechanical switches
(Option 222)
Along with the access loops and attenuators of Option 217,
Option 222 includes an internal second source, a combiner,
mechanical switches, and more access loops. The internal
second source provides an additional signal (fixed or swept)
for two-tone intermodulation testing of amplifiers, or for
use as a local oscillator for testing mixers and frequency
converters. The mechanical switches switch the combiner in
and out as needed, as well as enabling the additional access
loops for advanced configurations. The second source is
available through two RF connectors on the front panel,
from port 1 when combined with source 1, or via rear-panel
access loops. The maximum power rating on the test port
couplers is +43 dBm (additional attenuators or isolators are
typically required to protect other components inside the
instrument). Option 222 is not available on the N5247B. To
independently control the frequency of the second internal
source, one of the following software applications is required:
S93080/029/082/083/084/086/087/089/090x/093/094B/A.
2-ports, single source, with extended power
range and bias-tees (Option 219)
This configuration comes with front-panel access loops, and
bias tees and source and receiver attenuators at each port. The
source attenuators are settable in 5 dB steps up to 65 dB in
N5241/42/49B, in 10 dB steps up to 60 dB in N5244/45B, and in
10 dB steps up to 50 dB in N5247B. The receiver attenuators are
settable in 5 dB steps up to 35 dB in N5241/42/44/45/49B, and
10 dB steps up to 50 dB in N5247B. The bias tees are connected
directly to the test port couplers, which limits the maximum power
rating on the pair to +30 dBm (additional attenuators or isolators
are typically required to protect other components inside the
instrument).
Find us at www.keysight.com
1. The block diagrams shown above include hardware that must be ordered
as separate options, such as pulse modulators (Options 021 and 022),
and IF access (Option 020), or is controlled by application software, as
is the case for the pulse generators. In addition, the combiner type and
attenuator values vary by model number. Refer to the product data sheet
for the correct block diagram for a specific model.
Page 11
PNA-X Series Test Set and Power Configuration Options 1 (Continued)
Test port 3
C
R3
Test port 1
R1
Test port 4
R4
Test port 2
R2
ADB
Source 2
OUT 1OUT 2
Pulse
modulator
Source 1
OUT 1OUT 2
Pulse
modulator
Pulse generators
To receivers
LO
R A B C D
IF inputs
Rear panel
C
R3
R1
R4R2
35 dB
65 dB
35 dB
65 dB65 dB
35 dB
65 dB
A
35 dB
DB
OUT 1OUT 2
Pulse
modulator
OUT 1OUT 2
Pulse
modulator
To receivers
LO
R A B C D
IF inputs
Rear panel
Source 1
Source 2
Test port 1
Test port 3
Test port 2
Pulse generators
Test port 4
R1
Test port 2
R2
A
B
To receivers
LO
Source 2
Output 1
Source 2
Output 2
Pulse generators
Rear panel
1
2
3
4
Test port 1
Source 1
OUT 1OUT 2
Pulse
modulator
Source 2
OUT 1OUT 2
Pulse
modulator
J9J10J11J8J7J2 J1
35 dB
65 dB
35 dB
65 dB
J6 J5
RF
OUT
LO
OUT
RR1 R2A B
IF inputs
2-ports, dual sources, with extended power
range, bias tees, and mechanical switches
(Option 224)
Along with the access loops, attenuators, and bias tees of
Option 219, Option 224 includes an internal second source, a
combiner, mechanical switches, and more access loops. The
internal second source provides an additional signal (fixed or
swept) for two-tone intermodulation testing of amplifiers, or
for use as a local oscillator for testing mixers and frequency
converters. The mechanical switches switch the combiner in
and out as needed, as well as enabling the additional access
loops for advanced configurations. The second source is
available through two RF connectors on the front panel,
from port 1 when combined with source 1, or via rear-panel
(N5241/42/44/45/49B) or front-panel (N5247B) access
loops. The bias tees are connected directly to the test port
couplers, which limits the maximum power rating on the pair
to +30 dBm (additional attenuators or isolators are typically
required to protect other components inside the instrument).
To independently control the frequency of the second internal
source, one of the following software applications is required:
S93080/029/082/083/084/086/087/089/090x/093/094B/A.
To independently control the frequency of the second internal
source, one of the following software applications is required:
S93080/029/082/083/084/086/087/089/090x/093/094B/A.
4-ports, dual sources, with extended power range
(Option 417)
This configuration comes with two sources, front-panel
access loops, and source and receiver attenuators at each
port. The source attenuators are settable in 5 dB steps up
to 65 dB in N5241/42/49B, and in 10 dB steps up to 60 dB
in N5244/45B. The receiver attenuators are settable in 5 dB
steps up to 35 dB. The maximum power rating on the test
port couplers is +43 dBm (additional attenuators or isolators
are typically required to protect other components inside the
instrument). Option 417 is not available on the N5247B. To
independently control the frequency of the second internal
source, one of the following software applications is required:
S93080/029/082/083/084/086/087/089/090x/093/094B/A,
and S94510/511A.
4-ports, dual sources, with configurable test set
(Option 4 01)
The standard 4-port test set comes with 12 front-panel access
loops and a built-in second source. The loops provide access to
the signal path between (a) the source output and the reference
receiver, (b) the source output and directional coupler thru arm
and (c) the coupled arm of the directional coupler and the port
receiver. The internal second source provides an additional
signal (fixed or swept) for two-tone intermodulation testing of
amplifiers, or for use as a local oscillator when testing mixers and
frequency converters. Source 1 is accessible through test ports 1
and 2, and source 2 is accessible through test ports 3 and 4. The
standard test set also includes a solid-state internal RF bypass
switch in the R1 reference-receiver path.
Find us at www.keysight.com
1. The block diagrams shown above include hardware that must be ordered
as separate options, such as pulse modulators (Options 021 and 022),
and IF access (Option 020), or is controlled by application software, as
is the case for the pulse generators. In addition, the combiner type and
attenuator values vary by model number. Refer to the product data sheet
for the correct block diagram for a specific model.
Page 12
PNA-X Series Test Set and Power Configuration Options 1 (Continued)
Test port 3
C
R3
Test port 1
R1
Test port 4
R4
Test port 2
R2
A
D
B
To receivers
LO
Pulse generators
Rear panel
1
2
3
4
Source 1
OUT 1OUT 2
Pulse
modulator
Source 2
(standard)
OUT 1OUT 2
Pulse
modulator
J9J10J11J8J7J2 J1J4 J3
35 dB35 dB35 dB
35 dB
65 dB65 dB65 dB65 dB
J6 J5
RF
OUT
LO
OUT
R A B C D
IF inputs
Test port 3
C
R3
Test port 1
R1
Test port 4
R4
Test port 2
R2
35 dB
65 dB
35 dB
65 dB65 dB
35 dB
65 dB
A
35 dB
DB
Source 2
OUT 1OUT 2
Pulse
modulator
Source 1
OUT 1OUT 2
Pulse
modulator
Pulse generators
To receivers
LO
R A B C D
IF inputs
Rear panel
4-ports, dual sources, with extended power range
and bias-tees (Option 419)
This configuration comes with two sources, front-panel access
loops, and bias tees and source and receiver attenuators at
each port. The source attenuators are settable in 5 dB steps
up to 65 dB in N5241/42/49B, in 10 dB steps up to 60 dB
in N5244/45B, and in 10 dB steps up to 50 dB in N5247B.
The receiver attenuators are settable in 5 dB steps up to
35 dB in N5241/42/44/45/49B, and 10 dB steps up to 50 dB in
N5247B. The bias tees are connected directly to the test port
couplers, which limits the maximum power rating on the pair
to +30 dBm (additional attenuators or isolators are typically
required to protect other components inside the instrument).
To independently control the frequency of the second internal
source, one of the following software applications is required:
S93080/029/082/083/084/086/087/089/090x/093/094B/A or
S94510/511A.
4-ports, dual sources, with extended power
range, combiner, and mechanical switches
(Option 422)
Along with two sources and the access loops and attenuators
of Option 417, Option 422 includes a combiner, mechanical
switches, and more access loops. The internal second source
provides an additional signal (fixed or swept) for two-tone
intermodulation testing of amplifiers, or for use as a local
oscillator for testing mixers and frequency converters. The
mechanical switches switch the combiner in and out as needed,
as well as enabling the additional access loops for advanced
configurations. The second source drives ports 3 and 4, and is
also available from port 1 when combined with source 1, or via
rear-panel access loops. The maximum power rating on the test
port couplers is +43 dBm (additional attenuators or isolators
are typically required to protect other components inside the
instrument). Option 422 is not available on the N5247B. To
independently control the frequency of the second internal
source, one of the following software applications is required:
S93080/029/082/083/084/86/087/089/090x/093/094B/A or
S94510/511A.
1. The block diagrams shown above include hardware that must be ordered
as separate options, such as pulse modulators (Options 021 and 022),
and IF access (Option 020), or is controlled by application software, as
is the case for the pulse generators. In addition, the combiner type and
attenuator values vary by model number. Refer to the product data sheet
for the correct block diagram for a specific model.
Find us at www.keysight.com
Page 13
PNA-X Series Test Set and Power Configuration Options (Continued)
Standard source
10 MHz - 8.5/13.5/26.5/43.5/50/67.5 GHz
Pulse modulator
R1
A
Test
port
A'
LF source
900 Hz - 100 MHz
R1'
External bias
Test port 3
C
R3
Test port 1
R1
Test port 4
R4
Test port 2
R2
A
D
B
To receivers
LO
Pulse generators
Rear panel
1
2
3
4
Source 1
OUT 1OUT 2
Pulse
modulator
Source 2
(standard)
OUT 1OUT 2
Pulse
modulator
J9J10J11J8J7J2 J1J4 J3
35 dB35 dB35 dB
35 dB
65 dB65 dB65 dB65 dB
J6 J5
RF
OUT
LO
OUT
R A B C D
IF inputs
4-ports, dual sources, with extended power
range, bias tees, combiner, and mechanical
switches (Option 423)
Along with two sources and the access loops, attenuators,
and bias tees of Option 419, Option 423 includes a combiner,
mechanical switches, and more access loops. The internal
second source provides an additional signal (fixed or swept) for
two-tone intermodulation testing of amplifiers, or for use as a
local oscillator for testing mixers and frequency converters. The
mechanical switches switch the combiner in and out as needed,
as well as enabling the additional access loops for advanced
configurations. The second source drives ports 3 and 4, and
is also available from port 1 when combined with source 1, or
via rear-panel (N5241/42/44/45/49B) or front-panel (N5247B)
access loops. The bias tees are connected directly to the test
port couplers, which limits the maximum power rating on the
pair to +30 dBm (additional attenuators or isolators are typically
required to protect other components inside the instrument).
To independently control the frequency of the second internal
source, one of the following software applications is required:
S93080/029/082/083/084/086/087/089/090x/093/094B/A or
S94510/511A.
4-ports, dual sources, with extended power
range, bias tees, combiner, mechanical switches,
and low-frequency extension (Option 425)
Along with two sources and the access loops, attenuators,
bias tees, combiner, and mechanical switches of Option 423,
Option 425 adds additional hardware to extend the start
frequency of the PNA-X down to 900 Hz. The extended star t
frequency is available only for the following measurement
classes: standard, gain compression (amplifier and converters),
and for magnitude-only measurements using SMC (scalar
mixer/converter) or SMC+Phase. In the standard channel,
pulsed RF, true-mode stimulus, and source phase control
are not supported for measurements below 10 MHz. To
independently control the frequency of the second internal
source, one of the following software applications is required:
S93080/029/082/083/084/086/087/089/090x/093/094B/A
or S94510/511A. The block diagram below shows how the
low-frequency hardware is configured for one test port; the other
test ports are configured similarly. For test port 1, the combiner
and noise tuner (not shown) are only available for use down to
10 MHz, and for test port 2, the low-noise receiver (not shown) is
only available for use down to 10 MHz.
1. The block diagrams shown above include hardware that must be ordered
as separate options, such as pulse modulators (Options 021 and 022),
and IF access (Option 020), or is controlled by application software, as
is the case for the pulse generators. In addition, the combiner type and
attenuator values vary by model number. Refer to the product data sheet
for the correct block diagram for a specific model.
Find us at www.keysight.com
Page 14
Test port 1Test port 2
AB
R1
R2
Source
OUT 1OUT 2
Pulse
modulator
To receivers
LO
Pulse generators
RABCD
IF inputs
Rear panel
Test port 1
R1
Test port 2
R2
AB
Source
OUT 1OUT 2
Pulse
modulator
To receivers
LO
Pulse generators
RABCD
IF inputs
Rear panel
Standard source
10 MHz - 8.5/13.5/26.5/43.5/50/67.5 GHz
Pulse modulator
R1
A
Test
port
A'
LF source
900 Hz - 100 MHz
R1'
External bias
PNA Series Test Set and Power Configuration Options
1
The PNA is an integrated vector network analyzer featuring a
built-in S-parameter test set, one or two synthesized sources
used for device stimulus, a solid-state drive, USB interfaces, and
a 12.1” LCD touch screen display. The N5221B and the N5222B
have 50 ohm, ruggedized 3.5 mm (m) test ports. The N5224B
and the N5225B have 50 ohm, ruggedized 2.4 mm (m) test ports.
The N5227B has 50 ohm, ruggedized 1.85 mm (m) test ports.
Included with each instrument is a mouse, keyboard (U.S. style),
test port torque wrench, and one day of on-site productivity
assistance (PS-S20-PNA).
A test set and power configuration option is mandatory. Choose
one of the following:
2-ports, single source, base configuration (Option
200/210)
The 2-port with base configuration has no front-panel access
loops.
2-ports, single source, with configurable test set,
bias tees, and low-frequency extension (Option
205)
Along with the front-panel loops and R1 reference-receiver
switch of Option 201, Option 205 adds bias tees and additional
hardware to extend the start frequency of the PNA down to
900 Hz. The extended start frequency is available only
for the following measurement classes: standard, gain
compression (amplifier and converters), and for magnitudeonly measurements using SMC (scalar mixer/converter) or
SMC+Phase. In the standard channel, pulsed RF, true-mode
stimulus, and source phase control are not supported for
measurements below 10 MHz. The block diagram below shows
how the low-frequency hardware is configured for one test port;
the other test por ts are configured similarly.
2-ports, single source, with configurable test set
(Option 201)
The 2-port configurable test set comes with six front-panel
access loops. The loops provide access to the signal path
between (a) the source output and the reference receiver, (b)
the source output and directional coupler thru arm and (c) the
coupled arm of the directional coupler and the port receiver at all
ports. Also included is a solid-state internal RF bypass switch in
the R1 reference-receiver path.
Find us at www.keysight.com
1. The block diagrams shown above include hardware that must be ordered
as separate options, such as pulse modulators (Option 021), and IF
access (Option 020), or is controlled by application sof tware, as is
the case for the pulse generators. In addition, the combiner type and
attenuator values vary by model number. Refer to the product data sheet
for the correct block diagram for a specific model.
Page 15
Test port 1
R1
Test port 2
R2
35 dB
65 dB65 dB
A
35 dB
B
Source
OUT 1OUT 2
Pulse
modulator
To receivers
LO
Pulse generators
RABCD
IF inputs
Rear panel
R1
R2
35 dB
65 dB65 dB
A
35 dB
B
Source
OUT 1OUT 2
Pulse
modulator
To receivers
LO
Pulse generators
RABCD
IF inputs
Rear panel
Test port 3
R3
Test port 1Te st port 4
R4
Test port 2
R2
R1
ACDB
Source 2
OUT 1OUT 2
Pulse
modulator
Source 1
OUT 1OUT 2
Pulse
modulator
Pulse generators
To receivers
LO
RABCD
IF inputs
Rear panel
PNA Series Test Set and Power Configuration Options 1 (Continued)
Standard source
10 MHz - 8.5/13.5/26.5/43.5/50/67.5 GHz
Pulse modulator
R1
A
Test
port
A'
LF source
900 Hz - 100 MHz
R1'
External bias
2-ports, single source, with extended power
range (Option 217)
This configuration comes with front-panel access loops, and
source and receiver attenuators at each port. The source
attenuators are settable in 5 dB steps up to 65 dB in N5221/22B,
and in 10 dB steps up to 60 dB in N5224/25B. The receiver
attenuators are settable in 5 dB steps up to 35 dB. The maximum
power rating on the test port couplers is +43 dBm (additional
attenuators or isolators are typically required to protect other
components inside the instrument). Option 217 is not available on
the N5227B.
2-ports, single source, with extended power
range, bias-tees, and low-frequency extension
(Option 220)
Along with the front-panel access loops, bias tees, source
and receiver attenuators of Option 219, Option 220 adds
additional hardware to extend the start frequency of the PNA
down to 900 Hz. The extended start frequency is available
only for the following measurement classes: standard, gain
compression (amplifier and converters), and for magnitudeonly measurements using SMC (scalar mixer/converter) or
SMC+Phase. In the standard channel, pulsed RF, true-mode
stimulus, and source phase control are not supported for
measurements below 10 MHz. The block diagram below shows
how the low-frequency hardware is configured for one test port;
the other test por ts are configured similarly.
2-ports, single source, with extended power
range and bias-tees (Option 219)
This configuration comes with front-panel access loops, and bias
tees and source and receiver attenuators at each port. The source
attenuators are settable in 5 dB steps up to 65 dB in N5221/22B,
in 10 dB steps up to 60 dB in N5224/25B, and in 10 dB steps
up to 50 dB in N5227B. The receiver attenuators are settable in
5 dB steps up to 35 dB in N5221/22/24/25B, and 10 dB steps up
to 50 dB in N5227B. The bias tees are connected directly to the
test port couplers, which limits the maximum power rating on the
pair to +30 dBm (additional attenuators or isolators are typically
required to protect other components inside the instrument).
Find us at www.keysight.com
4-ports, dual source, base configuration (Option
40 0/410)
The 4-port with base configuration has no front-panel access
loops. To independently control the frequency of the second
internal source, one of the following software applications is
required: S93080/029/082/083/084/086/087/089/090x/093/
094B/A.
1. The block diagrams shown above include hardware that must be ordered
as separate options, such as pulse modulators (Options 021 and 022),
and IF access (Option 020), or is controlled by application software, as
is the case for the pulse generators. In addition, the combiner type and
attenuator values vary by model number. Refer to the product data sheet
for the correct block diagram for a specific model.
Page 16
Test port 3
C
R3
Test port 1
R1
Test port 4
R4
Test port 2
R2
35 dB
65 dB
35 dB
65 dB65 dB
35
dB
65 dB
A
35 dB
DB
Source 2
OUT 1OUT 2
Pulse
modulator
Source 1
OUT 1OUT 2
Pulse
modulator
Pulse generators
To receivers
LO
RABCD
IF inputs
Rear panel
PNA Series Test Set and Power Configuration Options 1 (Continued)
Standard source
10 MHz - 8.5/13.5/26.5/43.5/50/67.5 GHz
Pulse modulator
R1
A
Test
port
A'
LF source
900 Hz - 100 MHz
R1'
External bias
Test port 3
C
R3
Test port 1
R1
Test port 4
R4
Test port 2
R2
ADB
Source 2
OUT 1OUT 2
Pulse
modulator
Source 1
OUT 1OUT 2
Pulse
modulator
Pulse generators
To receivers
LO
RABCD
IF inputs
Rear panel
4-ports, dual source, with configurable test set
(Option 4 01)
The 4-port configurable test set comes with two internal
sources, and twelve front-panel access loops. The loops provide
access to the signal path between (a) the source output and the
reference receiver, (b) the source output and directional coupler
thru arm and (c) the coupled arm of the directional coupler
and the port receiver at all ports. Also included is a solid-state
internal RF bypass switch in the R1 reference-receiver path.
To independently control the frequency of the second internal
source, one of the following software applications is required:
S93080/029/082/083/084/086/087/089/090x/093/094B/A.
4-ports, dual source, with extended power range
(Option 417)
This configuration comes with two sources, front-panel
access loops, and source and receiver attenuators at each
port. The source attenuators are settable in 5 dB steps up
to 65 dB in N5221/22B, and in 10 dB steps up to 60 dB in
N5224/25B. The receiver attenuators are settable in 5 dB
steps up to 35 dB. The maximum power rating on the test
port couplers is +43 dBm (additional attenuators or isolators
are typically required to protect other components inside the
instrument). Option 417 is not available on the N5227B. To
4-ports, dual source, and low-frequency
extension (Option 405)
Along with the two sources, 12 front-panel access loops and
R1 reference-receiver switch of option 401, Option 405 adds
additional hardware to extend the start frequency of the PNA
down to 900 Hz. The extended start frequency is available
only for the following measurement classes: standard, gain
compression (amplifier and converters), and for magnitudeonly measurements using SMC (scalar mixer/converter) or
SMC+Phase. In the standard channel, pulsed RF, true-mode
stimulus, and source phase control are not supported for
measurements below 10 MHz. The block diagram below shows
how the low-frequency hardware is configured for one test port;
the other test por ts are configured similarly.
independently control the frequency of the second internal
source, one of the following software applications is required:
S93080/029/082/083/084/086/087/089/090x/093/094B/A.
1. The block diagrams shown above include hardware that must be ordered
as separate options, such as pulse modulators (Options 021 and 022),
and IF access (Option 020), or is controlled by application software, as
is the case for the pulse generators. In addition, the combiner type and
attenuator values vary by model number. Refer to the product data sheet
for the correct block diagram for a specific model.
Find us at www.keysight.com
Page 17
Test port 3
C
R3
Test port 1
R1
Test port 4
R4
Test port 2
R2
35 dB
65 dB
35 dB
65 dB65 dB
35
dB
65 dB
A
35 dB
DB
Source 2
OUT 1OUT 2
Pulse
modulator
Source 1
OUT 1OUT 2
Pulse
modulator
Pulse generators
To receivers
LO
RABCD
IF inputs
Rear panel
Standard source
10 MHz - 8.5/13.5/26.5/43.5/50/67.5 GHz
Pulse modulator
R1
A
Test
port
A'
LF source
900 Hz - 100 MHz
R1'
External bias
PNA Series Test Set and Power Configuration Options 1 (Continued)
4-ports, dual source, with extended power range
and bias-tees (Option 419)
This configuration comes with two sources, front-panel access
loops, and bias tees and source and receiver attenuators
at each port. The source attenuators are settable in 5 dB
steps up to 65 dB in N5221/22B, in 10 dB steps up to 60 dB
in N5224/25B, and in 10 dB steps up to 50 dB in N5227B.
The receiver attenuators are settable in 5 dB steps up to
35 dB in N5221/22/24/25B, and 10 dB steps up to 50 dB in
N5227B. The bias tees are connected directly to the test port
couplers, which limits the maximum power rating on the pair
to +30 dBm (additional attenuators or isolators are typically
required to protect other components inside the instrument).
To independently control the frequency of the second internal
source, one of the following software applications is required:
S93080/029/082/083/084/086/087/089/090x/093/094B/A.
4-ports, dual source, with extended power range,
bias-tees, and low-frequency extension (Option
420)
4-ports, dual source, with extended power range, bias-tees,
and low-frequency extension (Option 420). Along with the two
sources, front-panel access loops, bias tees, source and receiver
attenuators of Option 419, Option 420 adds additional hardware
to extend the start frequency of the PNA down to 900 Hz. The
extended start frequency is available only for the following
measurement classes: standard, gain compression (amplifier and
converters), and for magnitude-only measurements using SMC
(scalar mixer/converter) or SMC+Phase. In the standard channel,
pulsed RF, true-mode stimulus, and source phase control are not
supported for measurements below 10 MHz. The block diagram
below shows how the low-frequency hardware is configured for
one test port; the other test ports are configured similarly.
1. The block diagrams shown above include hardware that must be ordered
as separate options, such as pulse modulators (Options 021 and 022),
and IF access (Option 020), or is controlled by application software, as
is the case for the pulse generators. In addition, the combiner type and
attenuator values vary by model number. Refer to the product data sheet
for the correct block diagram for a specific model.
Find us at www.keysight.com
Page 18
Source
To receivers
A
DCB
R
LO
Test port 2Test port 3Test port 4Test port 1
Source
To receivers
A
R1
R2
B
LO
Test port 2Test port 1
60 dB
60 dB
Source
To receivers
A
R1
R2
B
LO
Test port 2
Test port 1
PNA-L Series Test Set and Power Configuration Options
D
BC
Source
To receivers
A
R
LO
Test port 4Test port 3Test port 2Test port 1
60 dB
The PNA-L is an integrated vector network analyzer featuring a
built-in S-parameter test set, one synthesized source used for
device stimulus, a solid state drive, USB interfaces, and a 12.1”
LCD touch screen display. The N5239B, N5231B and the N5232B
have 50 ohm, ruggedized 3.5 mm (m) test ports. The N5234A and
N5235B have 50 ohm, ruggedized 2.4 mm (m) test portcluded
with each instrument is a mouse, keyboard (U.S. style). For
one day of on-site productivity assistance (not included with
instrument purchase), request quantity 1 each PS-S20-PNA.
A test set and power configuration option is mandatory. Choose
one of the following:
2 ports, single source, base configuration (Option
200)
The 2-port with base configuration has no front-panel access loops.
2 ports, single source, with configurable test set
and source attenuators (Option 216)
4 ports, single source, base configuration (Option
400)
The 4-port base configuration has no front-panel loops, and is
available only on the N5231B and N5232B.
4 ports, single source, with configurable test set
and source attenuator (Option 416)
The 4-port test set comes with a configurable test set and one
source attenuator to be shared with all ports. The configurable
test set adds nine front-panel access loops. The loops provide
access to the signal path between (a) the source output and the
reference receiver, (b) the source output and directional coupler
thru arm at all ports, and (c) the coupled arm of the directional
coupler and the port receiver at all ports. The source attenuator
is settable in 10 dB steps up to 60 dB. This configuration is
available only on the N5231B and N5232B.
The 2-port test set comes with a configurable test set and
source attenuator at each port. The configurable test set adds six
front-panel access loops. The loops provide access to the signal
path between (a) the source output and the reference receiver,
(b) the source output and directional coupler thru arm, and (c) the
coupled arm of the directional coupler and the port receiver at all
ports. The source attenuators are settable in 10 dB steps up to 60 dB.
Find us at www.keysight.com
Page 19
PNA Family Applications and Options
Measurement application software
Solid black series name indicates the feature is available on that
series, while gray series name with strikethrough indicates the
feature is not available on that series. For example:
PNA: Available on PNA Series
PNA: Not available on PNA Series
Automatic fixture removal (S93007B/A)
PNA-X PNA PNA-L
Many devices do not have coaxial connectors and are put in
fixtures in order to measure them in a coaxial environment.
Accurately removing the effects of the fixture is required to
get a good measurement of the device under test (DUT). This
application adds a powerful application wizard to guide you
through characterizing a fixture and removing it from the
measurement. Devices can be single ended or differential. Files
can be saved in a variety of formats for later use in PNA, ADS,
and PLTS.
Real time S-parameter and power measurement
uncer t aint y (S93015B /A)
PNA-X PNA PNA-L
The real time S-parameter and power measurement uncertainty
(S93015B/A) provides uncertainties for both S-parameter and
power measurements on the PNA-X, PNA and PNA-L. The
real-time display of the uncertainty associated with power
and S-parameter traces increases the confidence in the
reproducibility of measurements. This allows users to implement
pass/fail tests easily because now the instrument quantifies
the gray region that is in between a full pass or a full fail, apply
more realistic limit lines which can increase the production yield
and reduce the defect percentage on the finished products. This
application easily establishes a metric to quantify the quality of
the measurement process, so your company’s quality control
procedures are simplified. It includes the uncertainty information
for most Keysight calibration kits, and provides national
metrology institute traceability through Keysight’s calibration
kits. This application also helps you to include uncertainty
information for your product’s specifications and data sheets.
Frequency offset measurements (S93080B/A)
Time domain analysis (S93010B/A)
PNA-X PNA PNA-L
This application enables the analyzer to view reflection and
transmission responses in time or distance. Use time domain
to tune filters, gate out the response of fixtures and cables,
characterize the impedance of transmission lines and more.
If eye-diagram analysis, the enhanced time domain analysis
S93011B/A or high-speed interconnect testing is required, PLTS
N1930B software must be used.
Enhanced time domain analysis with TDR
(S9 3 011B/A)
PNA-X PNA PNA-L
This application enables the analyzer to perform enhanced
time domain analysis for high-speed data applications. All
functionality of the S93010B/A are included (TDR/ TDT mode). In
addition, the S93011B/A enables more detailed measurements
and evaluations, such as eye-diagram/mask modes, without
adding PLTS software. Jitters and/or emphasis/equalization
capabilities enables simulation of real-world signals and
environment. The S93011B/A covers up to 67 GHz bandwidth
with 6.66 psec rise time. Full calibration is available and the
automatic deskew ensures easy removal of fixture and probe
effects. To get the best accuracy, mechanical calibration kits
or E-cal with DC option are recommended. When S93011B/A
is used on a unit equipped with low frequency extension(LFE)
function, the LFE function is disabled. If PAM4, W-element
modeling, or greater than 4-ports or more detailed post proces
data analysis is required, the N1930B PLTS is required.
2
PNA-X PNA PNA-L
This application enables the analyzer to set the frequency of
the internal sources independently from where the receivers
are tuned, and is required to configure an external source
using External Device Configuration. This ability is important
for measuring amplifiers, mixers, and frequency converters.
The functionality provided by S93080B/A is also included with
S93029/082/083/084/086/087/089/090x/093/094B/A or
S94510/511A.
Scalar mixer/converter measurements
(S93082B/A)
PNA-X PNA PNA-L
With a simple setup and calibration, this application delivers the
highest accuracy for scalar conversion-loss/gain measurements
by combining one-port and power-meter calibrations to
remove mismatch errors. S93082B/A provides an intuitive and
easy-to-use user interface for setting up mixer and converter
measurements, with single or dual conversion stages. It can
control the analyzer’s built-in source(s) as well as external signal
generators for use as LO signals. Supported external sources
include the Keysight ESG, PSG, EXG, and MXG Series, as well
as other SCPI-controlled signal generators. S93082B/A is a
subset of S93083B/A, so they should not be installed together.
S93082B/A is compatible with S93084B/A, which enables
measurements of converters with internal LOs.
1. When a comb generator is used as a phase reference for calibration and
the start frequency of the measurement is less than 55 MHz, a user-supplied calibration mixer is required. For measurements between 50 GHz
and 67 GHz, an additional high-pass filter is required (two back-to-back
Keysight V281A waveguide-to-coax adapters recommended; must be
ordered separately).
2. When the S93011B/A is shipped separately from the instrument, system
default calibration is needed at the installation.
Find us at www.keysight.com
Page 20
PNA Family Applications and Options (Continued)
Measurement application software (Continued)
Vector and scalar mixer/converter measurements
(S93083B/A)
PNA-X PNA PNA-L
This application includes the scalar mixer/converter plus phase
(SMC+Phase) measurement class that provides fully calibrated
conversion gain/loss, relative phase, and absolute group delay
measurements of mixers and converters without the need for
reference or calibration mixers. Eliminating the calibration
mixer requires a U9391C/F/G comb generator 1 and an external
DC power supply capable of sourcing +15 V and 300 mA for
U9391C/F or 800 mA for U9391G. A vector mixer/converter
measurement (VMC) class is also included for measuring the
phase dif ference between multiple paths or devices, or for
measuring phase shifts within a device. Using VMC or the
comb-generator-based calibration for SMC+Phase requires an
instrument with a configurable test set (i.e., has front-panel RF
loops). For units without front-panel loops, SMC+Phase can be
used with a calibration mixer supplied by the user. S93083B/A
provides an intuitive and easy-to-use user interface for setting
up mixer and converter measurements, with single or dual
conversion stages. It can control the analyzer’s built-in source(s)
as well as external signal generators for use as LO signals.
Supported external sources include the Keysight ESG, PSG,
EXG, and MXG Series, as well as other SCPI-controlled signal
generators. S93083B/A is a superset of S93082B/A, so they
should not be installed together. S93083B/A is compatible with
S93084B/A, which enables measurements of converters with
internal LOs.
The intermodulation distortion (IMD) application makes it
very easy to set up and calibrate swept-IMD measurements
of both amplifiers and frequency converters. It controls the
frequency and power of internal and external sources and
tunes the receivers to the main tones as well as the IMD
products in a single measurement channel. The user can sweep
either the center frequency of the two stimulus signals, the
frequency spacing of the two stimulus signals about a fixed
center frequency, or the power of one or both stimulus signals
or the power of the LO signal. The analyzer can measure
intermodulation distortion products of order 2, 3, 5, 7, or 9,
and can display the associated intercept points. In addition, an
IM Spectrum mode gives a spectrum-analyzer-like display for
confirming or trouble-shooting measurements. Not available with
PNA Options 200, 210, 400 and 410. When configured with a
2-port PNA or 2-port PNA-X with either Option 201, 217, or 219,
an external signal generator and a combiner are required. When
configured with a 4-port PNA or 4-port PNA-X with Option 401,
417, or 419, the two internal sources and an unused test por t
coupler configured as a combiner can be used for two-tone IMD
measurements. When configured with PNA-X Option 22x or 42x,
the two internal sources and internal combiner can be used for
two-tone IMD measurements.
Source phase control (S93088B/A)
PNA-X PNA PNA-L
Embedded LO capability (S93084B/A)
PNA-X PNA PNA-L
This application tunes the analyzer’s receivers to the output
frequency of the converter under test without the need for
access to internal LOs or a common reference signal. S93084B/A
is intended to work with S93029/082/083/086/087B/A
measurement applications.
Gain compression measurements (S93086B/A)
PNA-X PNA PNA-L
The gain compression application (GCA) provides input power,
output power, gain, and phase at the compression point of an
amplifier or frequency converter, over a specified frequency
range. GCA's SMART Sweep is very fast and easy-to-use. GCA
also includes a guided calibration that corrects for absolute
power levels, frequency response, and mismatch errors.
Find us at www.keysight.com
This application allows users to set calibrated, arbitrary phase
differences between two signal sources. The sources can be the
analyzer’s internal sources or external signal generators routed
through the analyzer’s test set. The phase difference can be
fixed, or swept between two specified phase values. Option 088
also controls the relative power level between the sources using
the receiver-leveling feature. Option 088 is targeted for activeload control, where the analyzer provides a precise, electronically
settable impedance to the output port of a device, while gain and
output power are measured. This capability can be combined
with external load-pull software to create traditional load-pull
power contours. Not available with PNA Options 200 and 210.
Page 21
PNA Family Applications and Options (Continued)
Measurement application software (Continued)
Differential and I/Q device measurements
(S93089B/A)
PNA-X PNA PNA-L
This application combines source-phase control of multiple
internal or external sources with frequency-of fset mode,
enabling simplified test of I/Q modulators/conver ters and
differential mixers, and harmonic measurements of dif ferential
amplifiers. The phase difference between sources can be
fixed (for example, at 90 or 180 degrees), or swept between
two specified phase values. Providing accurate control of the
relative phase between sources eliminates the need for hybrid
couplers and baluns to create quadrature or differential signals.
After achieving the desired phase alignment, the instrument’s
receivers can be tuned to all frequencies needed to characterize
the DUT. On an I/Q modulator for example, measurements
can be made of both the desired and suppressed conversion
bands, along with LO leakage, harmonics and other spurious
signals. Phase sweeps can be used to determine a DUT’s phase
imbalance versus frequency. Users can specify measurements
with individual receivers or multiple receivers combined with a
wide range of mathematical operators. Power measurements
can employ match correction for increased accuracy. S93089B/A
only works on 4-port PNA or PNA-X models.
Spectrum analysis (S93090xB/A)
PNA-X PNA PNA-L
The spectrum analyzer (SA) application adds high-performance
microwave spectrum analysis to PNA-X, PNA, and PNA-L Series
network analyzers. With fast stepped-FFT sweeps resulting from
optimized data processing, the SA application provides quick
spurious searches over broad frequency ranges. Simultaneous
spectrum measurements can be done using up to five test and
reference receivers. This multi-channel SA can be used with
the internal swept-signal generators for efficient measurements
of spurious signals emanating from mixers and frequency
converters. The SA application employs source-power and
receiver-response calibration as well as fixture de-embedding,
providing in-fixture and on-wafer spectrum measurements with
the highest level of accuracy. Accurate and fast noise power ratio
(NPR) measurement capability is also included in this software
application. It provides the ability of setting up and controlling
of external signal generator/arbitrary waveform generators and
performing the calibration of the flatness of a wideband signal
and distor tion signals in notches, and achieving very fast NPR
measurements. It is recommended to use this option with PNA
or PNA-X instruments with internal receiver attenuators to avoid
receiver compression when measuring large signals. For use with
PNA-L models, test set option 216 or 416 is recommended so
that external attenuators can be connected via the front-panel
jumpers to avoid receiver compression. The upper frequency
range of the SA application is determined by the installed SA
license or the stop frequency of the instrument, whichever
is smaller. There are several frequency choices intended for
standalone instruments: S930900B/A to 8.5 GHz, S930901B/A to
13.5 GHz, S930902B/A to 26.5 GHz, S930904B/A to 43.5 GHz,
S930905B/A to 50 GHz, and S930907B/A to 67 GHz. Intended
for use with analyzers configured with broadband or banded
millimeter-wave extenders, several more choices are available:
S930909B/A to 90 GHz, S93093B/A to 120 GHz, and S93094B/A
for frequencies above 120 GHz.
Find us at www.keysight.com
Spectrum analysis, up to 120 GHz (S93093B/A)
PNA-X PNA PNA-L
S93093B/A has all of the capability of the S93090xB/A spectrum
analyzer application, with an upper frequency of 120 GHz. It is
intended for analyzers configured with broadband or banded
millimeter-wave frequency extenders, using a millimeter-wave
controller. With this configuration, the analyzer’s internal receiver
attenuators are not in the receiver paths, so they cannot be used
to reduce signal levels. External attenuators may be required to
avoid compressing the receivers in the millimeter-wave frequency
extenders. When using S93093B/A for millimeter-wave spectrum
analysis, an N5261/62A or an N5292A millimeter-wave controller
is required. When S93093B/A is installed on a standalone
network analyzer, it will provide spectrum analysis up to the
frequency limit of the instrument.
Page 22
PNA Family Applications and Options (Continued)
Measurement application software (Continued)
Spectrum analysis, beyond 120 GHz (S93094B/A)
PNA-X PNA PNA-L
S93094B/A has all of the capability of the S93090xB/A
spectrum analyzer application, with an upper frequency limit
determined solely by the broadband or banded millimeter-wave
frequency extenders used in the system. With this configuration,
the analyzer’s internal receiver attenuators are not in the
receiver paths, so they cannot be used to reduce signal levels.
External attenuators may be required to avoid compressing the
receivers in the millimeter-wave frequency extenders. When
using S93094B/A for millimeter-wave spectrum analysis, an
N5261/62A or an N5292A millimeter-wave controller is required.
When S93094B/A is installed on a standalone network analyzer,
it will provide spectrum analysis up to the frequency limit of the
instrument.
Active hot parameters (S93110B/A/S93111B/A)
PNA-X PNAPNA-L
Active hot parameters allows the PNA-X Series a more accurate
method for testing Hot S-parameter, gain and output power than
traditional methods by utilizing the X-parameter technology.
It removes active device and system interaction to precisely
calculate the active parameters and output power into a nominal
50 Ω environment. The advanced theory removes system-to-
system correlation problems. S93110/111B/A also provides
key parameters of optimal load for maximum power, maximum
power delivered to optimal load, and the DUT’s fundamental
X-parameters. Total 14 traces (parameters) are available with
various sweep types, such as frequency sweep, power sweep,
or two-dimensional frequency and power sweep. Requires
4-port option configuration. LFE function is diabled when using
on Option 425. S93110B/A covers up to the PNA-X’s highest
frequency. S93111B/A is the export-controlled version and covers
up to 50 GHz on the N5247B.
True-mode stimulus (S93460B/A)
PNA-X PNA PNA-L
S93460A provides mismatch-corrected true-mode (true
differential mode and true common mode) stimulus and
enables accurate balanced measurements under real operating
conditions. It also provides balanced measurements with
forward-only sweeps, reverse-only sweeps, and frequency
or power sweeps with arbitrary phase and amplitude offsets.
S93460B/A only works on 4-port PNA or PNA-X models.
N-port measurements (S93551B/A)
PNA-X PNA PNA-L
S93551B/A adds a multiport analyzer mode, which enables full
N-port error correction and measurement capabilities using an
external test set. Only the standard measurement class is available
in the multiport analyzer mode. Not available with PNA Options
200, 210, 400 and 410. For multiport analysis greater than 8 ports,
it is highly recommended to use N1930B PLTS software to manage
the large data files that grow exponentially (12 port S-parameter
files have 144 S-parameter elements).
1
1. When configuring N524xB as a multiport analy zer using S93551B/A and a
multiport test set, the combiner feature of Option 22x or 42x is temporarily disabled. When configured as a standalone analyzer, the combiner
feature is enabled. When ordering a test set, select an appropriate
interface kit. Refer to page 32 Multipor t Measurements section for more
details.
Find us at www.keysight.com
Page 23
PNA Family Applications and Options (Continued)
Noise figure options and applications
Add low-noise receiver (Option 029)
PNA-X PNA PNA-L
This option adds a low-noise receiver to the PNA-X to provide
wideband noise figure and noise-power measurements on
a broad range of devices. The noise receiver has three gain
settings, and contains the necessary filters to eliminate
out-of-band noise conversion. For N5241/42/49B instruments,
Option 029 adds a mechanical switch at port one to allow use
of an external ECal module as an impedance tuner to provide
high-accuracy noise figure measurements. For N5244/45/47B
instruments, Option 029 adds a built-in impedance tuner at port
one with a bypass switch. The noise receiver start frequency is
10 MHz and for N5241/42/44/45/49B instruments, it works up to
the stop frequency of the instrument. For N5247B instruments,
the low-noise receiver and tuner work up to 50 GHz only. For
noise figure measurements between 50 and 67 GHz, any of
the standard network analyzer receivers can be used. Option
029 is intended for use with S93029B/A software. Without the
software, the noise hardware cannot be utilized.
Noise figure measurements with vector correction
(S93029B/A)
PNA-X PNA PNA-L
This sof tware application enables high-accuracy noise figure and
noise-power measurements of amplifiers, frequency converters,
and mixers, utilizing Keysight’s unique vector-source-correction
technique that uses a source-impedance tuner to remove the
effects of imperfect system-source match. This approach yields
accuracy that surpasses that provided by the Y-factor method
and other cold-source implementations, especially for in-fixture,
on-wafer, and automated-test environments. A scalar-calibrated
method is also available that offers less accuracy, but is faster
and does not require an impedance tuner.
If S93029B/A is used on a PNA-X configured with Option
029, then it makes full use of the built-in low-noise receiver.
Optionally, noise figure measurements can be made using the
standard receivers for high-gain (> 60 dB), narrowband devices
that might otherwise overload the low-noise receiver, or for
noise figure measurements between 50 and 67 GHz on the
N5247B. If running on a PNA, a PNA-X without Option 029, or
for measurements up to 67 GHz, then the instrument’s standard
receivers are used. For those cases, an external preamplifier and
filter(s) is required for devices with < 30 dB of excess noise (gain
plus noise figure in dB) up to 20 GHz, < 40 dB up to 50 GHz, or
< 45 dB up to 67 GHz. Instruments with front panel jumpers are
recommended as they provide a convenient spot for adding a
preamplifier and filter for low-gain, low-noise-figure devices.
S93029B/A controls Keysight N46901 Series ECal modules
configured as impedance tuners for use with N522xB PNA
models or N5241/42/49B PNA-X models, or a built-in tuner for
N5244/45/47B PNA-X models with Option 029.
For calibration, a standard mechanical cal kit or ECal module is
required for the S-parameter portion of the cal (an ECal used
as a tuner cannot be shared for calibration). To calibrate the
low-noise receiver, either a noise source (346C or 346C-K01
recommended) or power meter is required. To calibrate a
standard receiver for noise figure measurements, a power meter
is required. For measurements of mixers and converters, a
power meter is always required, independent of whether a noise
source or power meter is used to calibrate the noise receiver. All
calibration accessories must be ordered separately.
Add mechanical noise tuner control for noise
figure/parameter measurements (S93027B/A )
PNA-X PNA PNA-L
Noise figure measurements using application sof tware
S93029B/A utilize an ECal module as an impedance tuner to
provide source-corrected noise figure and noise parameter
measurements of nominally matched devices, with gamma-opts
< 0.3. To measure noise parameters of unmatched devices with
higher gamma-opts, an external tuner is needed. This application
software enables control of Maury Microwave LXI tuners in place
of an ECal module, extending noise parameter measurements to
devices with gamma-opts < 0.9. Requires application software
S93029B/A. Refer to Maury Microwave’s website for more
information about compatible L XI tuners.
1. 85090 or N4430 Series ECal modules are not supported.
Find us at www.keysight.com
Page 24
C
R3
Test port 1
R1
Test port 4
R4
A
D
Rear panel
Pulse generators
1
2
3
4
Source 1
OUT 1OUT 2
Pulse
modulator
Source 2
OUT 1OUT 2
Pulse
modulator
Test port 2
R2
B
Noise receiver
10 MHz -
6 GHz
6-8.5/
13.5/
26.5 GHz
To receivers
LO
+28 V
Test port 3
Signal
combiner
+
-
Impedance tuner for noise
figure measurements
J9J10J11J8J7J2J1J4J3
35 dB35 dB35 dB
35 dB
65 dB
65 dB
65 dB
65 dB
J6J5
RF
OUT
LO
OUT
R A B C D
IF inputs
IF inputs
PNA Family Applications and Options (Continued)
PNA-X block diagrams with noise figure option
N5241/42 /4 9 B 4-port
block diagram with
noise figure option
1
Rear panel
+28V
+
-
R1
60 dB
Tuner
Rear panel+28 V
+
-
1. S93029B/A software is required to control the impedance tuner and tuner switch at port one, and the noise
Find us at www.keysight.com
OUT 1
Pulse
modulator
Tuner
R1
50 dB50 dB50 dB50 dB
Test port 1
receiver and noise switch at port two.
J9J10J11J8J7J2J1J4J3
Signal
combiner
Source 1
OUT 1OUT 2
Pulse
modulator
OUT 1OUT 2
Source 2
Pulse
modulator
J6J5
RF
OUT
R3
Test port 1
Source 1
A
35 dB35 dB35 dB
60 dB
OUT 2
Signal
combiner
C
Test port 3
J12J6J5J7J2J1J4J3
RF2
OUT
Source 2
(standard)
OUT 1OUT 2
Pulse
modulator
R3
A
50
dB
Test port 3
C
LO
OUT
R4
RF1
OUT
50 dB
60 dB
LO
OUT
R4
Test port 4
Pulse generators
LO
Test port 4
LO
D
IF inputs
R A B C D
1
2
3
4
To receivers
R2
60 dB
R A B C D
Pulse generators
1
2
To receivers
R2
D
50 dB
3
4
Test port 2
Noise receiver
10 MHz-
50 GHz
6 GHz
B
Test port 2
Noise receivers
10 MHz -
6 GHz
B
6 -43.5/
35 dB
6 -50
GHz
50 dB
N5244/45B 4-port
block diagram with
noise figure option
N5247B 4-port
block diagram with
noise figure option
1
1
Page 25
PNA Family Applications and Options (Continued)
Noise figure measurement summary
OverviewS93029B/A without Option 029S93029B/A with Option 029
DescriptionNoise figure application using standard receivers
only, for all PNA/PNA-X models
Required optionsNot recommended with PNA Options 200, 210, 400,
410
Includes low-noise receiverNoYes
Includes filters for LO-harmonic
NoYes
rejection
Includes source tuner bypass switchNoYes
Use standard receivers for noise figure
measurements
2
Vector noise calibration available using
YesYes
YesYes
ECal as tuner
Vector noise calibration using built-in
NoYes, for N5244/45/47B
tuner
Recommended ECal for vector noise
calibration
3
3.5 mm N4691D-M0F (N5221/22/41/42/49B)3.5 mm N4691D-M0F (N5241/42/49B)
2.4 mm N4693D-M0F (N5224/25/44/45B)Built-in for N5244/45/47B
1.85 mm N4694D-M0F (N5227/47B)
Included tuner accessories for m-f ECal3.5 mm N5242-20169 cable, 85052-60013 m-f
adapter (N5221/22/41/42/49B)
2.4 mm N5245-20140 cable, 85056-60007 m-f
adapter
(N5224/25/44/45B)
1.85 mm N5247-20142 cable, 85058-60115 m-f
adapter (N5227/47B)
Recommended adapter for f-f ECal
tuner (N4691D/93D/94D-F0F)
3.5 mm 85052-60014 m-m adapter
(N5221/22/41/42/49B)
2.4 mm 85056-60005 m-m adapter
(N5224/25/44/45B)
1.85 mm 85058-60113 m-m adapter (N5227/47B)
Scalar noise calibration availableYesYes
S-parameter, conversion gain/loss measurements
Max freq (GHz)8.5/13.5/26.5/43.5/50/678.5/13.5/26.5/43.5/50/67
NF measurements, amplifiers
Max frequency, using low-noise
N/A8.5/13.5/26.5/43.5/50
receivers (GHz)
Max frequency, using standard
receivers (GHz)
2
Calibration accessories for low-noise
8.5/13.5/26.5/43.5/50/678.5/13.5/26.5/43.5/50
N/ACal kit or ECal, 346C or 346C-K01 noise source or
receivers
Calibration accessories for standard
Cal kit or ECal, power meterCal kit or ECal, power meter
receivers
Noise figure application using standard or low-noise
receivers, for all PNA-X models
For N5241/42/49B, one of Options 21x, 22x, 41x or 42x
For N5244/45/47B, one of Options 22x or 42x
1
1
1
3.5 mm N5242-20169 cable, 85052-60013 m-f adapter
(N5241/42/49B)
N/A for N5244/45B, due to built-in tuner
1.85 mm N5247-20142 cable, 85058-60115 m-f
adapter (N5247B, for use with external 67 GHz ECal)
3.5 mm 85052-60014 m-m adapter (N5241/42/49B)
N/A for N5244/45/47B, due to built-in tuner
power meter
1. For N5247B, the low-noise receiver and tuner works up to 50 GHz only.
2. External preamplifier and filter(s) required if DUT excess noise (gain plus noise figure) is < 30 dB up to
20 GHz, < 4 0 dB up to 50 GHz, or < 45 dB up to 67 GHz.
3. Only N4690 Series ECal modules are suppor ted for use as an impedance tuner.
Find us at www.keysight.com
Page 26
PNA Family Applications and Options (Continued)
Noise figure measurement summary
OverviewS93029B/A without Option 029S93029B/A with Option 029
NF measurements, converters
Max DUT input frequency (GHz)8.5/13.5/26.5/43.5/50/678.5/13.5/26.5/43.5/50/67
Max DUT output frequency, using
low-noise receivers (GHz)
Max DUT output frequency, using
standard receivers (GHz)
1
Calibration accessories for low-noise
receivers
Calibration accessories for standard
receivers
N/A8.5/13.5/26.5/43.5/50
8.5/13.5/26.5/43.5/50/678.5/13.5/26.5/43.5/50/67
N/ACal kit or ECal, power meter, 346C or 346C-K01 noise
source (optional)
Cal kit or ECal, power meterCal kit or ECal, power meter
1. External preamplifier and filter(s) required if DUT excess noise (gain plus noise figure) is < 30 dB up to
20 GHz, < 4 0 dB up to 50 GHz, or < 45 dB up to 67 GHz.
Find us at www.keysight.com
Page 27
PNA Family Applications and Options (Continued)
1 2 3 4 5 6 7 8
9 01 11 21 31 41 51
Pulse, antenna, mm-wave applications and
options
Solid black series name indicates the feature is available on that
series, whil e gray series name with strikethrough
indicates the feature is not available on that series. For example:
PNA: Available on PNA Series
PNA: Not available on PNA Series
Basic pulsed-RF measurements (S93025B/A)
PNA-X PNA PNA-L
This application enables four internal pulse generators that can
be used to control the internal pulse modulators (Options 021
and 022), and it provides an integrated pulse application that
uses the wideband-detection method. The pulse application
provides an easy way to set up point-in-pulse measurements
with pulse width as narrow as 200 ns, and pulse-profile
measurements with 50 ns minimum timing resolution. Using the
built-in pulse modulators, the PNA and PNA-X are complete
pulsed-RF measurement solutions, eliminating the need for
external test sets and pulse generators. S93025B/A also controls
external pulse generators and modulators, and can synchronize
to external master pulses. Option 021 is recommended for
forward-only pulsed-RF measurements, and Options 021
and 022 are recommended for bi-directional pulsed-RF
measurements. The N1966A Pulse I/O adapter is recommended
if using external master pulses or external pulse modulators.
to external master pulses. Option 021 is recommended for
forward-only pulsed-RF measurements, and Options 021 and 022
are recommended for bi-directional pulsed-RF measurements.
The N1966A Pulse I/O adapter is recommended if using external
master pulses or external pulse modulators.
Add pulse modulator to internal first source
(Option 021) PNA-X PNA PNA-L
This option enables the internal pulse modulator on Source1
Out1. Control of the modulator can be done via pin 8 of the Pulse
I/O D-sub connector on the rear panel of the analyzer using an
external pulse generator, or by using one of the internal pulse
generators enabled with S93025/26B/A. The N1966A pulse I/O
adapter is recommended if using an external pulse generator.
Add pulse modulator to internal second source
(Option 022) PNA-X PNA PNA-L
This option enables the internal pulse modulator on Source2
Out1. Control of the modulator can be done via pin 8 of the Pulse
I/O D-sub connector on the rear panel of the analyzer using an
external pulse generator, or by using one of the internal pulse
generators enabled with S93025/26B/A. The N1966A pulse I/O
adapter is recommended if using an external pulse generator.
Requires one of text set options 22x or 4xx.
Add IF inputs for antenna and millimeter-wave
(Option 020) PNA-X PNA PNA-L
Pulse I/O D-sub connector (DB-15 female)
Advanced pulsed-RF measurements (S93026B/A)
PNA-X PNA PNA-L
This application includes all of the capability of S93025B/A
(including enabling the four internal pulse generators), and
adds the narrowband-pulse-detection method to extend pulse
measurement capability to 20 ns pulse widths for point-in-pulse
measurements, and 10 ns timing resolution for pulse-profile
measurements. With narrowband-detection mode, S93026B/A
sets the coef ficient of the analyzer’s digital-IF filters to null out
unwanted spectral components, enables the receiver IF gates,
and performs optimization for measurement sensitivity. Using
the built-in pulse modulators, the PNA and PNA-X are complete
pulsed-RF measurement solutions, eliminating the need for
external test sets and pulse generators. S93026B/A also controls
external pulse generators and modulators, and can synchronize
This option enables external IF inputs on the rear panel of the
analyzer for applications such as antenna test and for use with
millimeter-wave test set controllers (for more information about
millimeter-wave network analyzer configurations, see MillimeterWave Network Analyzers Technical Overview, 5989-7620EN).
Fast CW sweep (S93118B/A)
PNA-X PNA PNA-L
This option uses a FIFO (first-in first-out) buffer to allow external
point-trigger acquisition of 400,000 data points per second on five
measurement receivers. When enabled, there is no display update,
no background computation, or other interference from the vector
network analyzer application. All the data gathered is placed into
a 500-million-point FIFO buffer. Data may be read from the FIFO
buffer at the same time as it is filled.
Nonlinear vector network analysis
Please refer to 5989-8575EN Nonlinear Vector Network
Analyzer Brochure for more information.
Find us at www.keysight.com
Page 28
PNA Family Applications and Options (continued)
Accessories
Solid black series name indicates the feature is available on that
series, while gray series name with strikethrough indicates the
feature is not available on that series. For example:
PNA: Available on PNA Series
PNA: Not available on PNA Series
Rack mount kit without handles (Option 1CM)
PNA-X PNA PNA-L
Adds a rack mount flange kit 1CM042A and a rail kit (E3663AC)
for use without handles.
Rack mount kit with handles (Option 1CP)
PNA-X PNA PNA-L
Adds a rack mount flange kit with handles (5063-1555) and a rail
kit (E3663AC) for use with handles.
Pulse I/O adapter (N1966A)
PNA-X PNA PNA-L
This adapter enables coaxial connections between the Pulse
I/O D-sub connector on the rear panel of the analyzer and the
coaxial inputs and outputs of external pulse generators and
external pulse modulators. Coaxial connectors are SMB-male.
The PULSE IN connectors are for controlling the analyzer’s
internal IF gates, which are enabled with S93026B/A and used
with narrowband detection. The PULSE OUT connectors are
from the four internal pulse generators, which are enabled
with S93025/26B/A. The PULSE SYNC IN connector is used to
synchronize the internal pulse generators with an external timing
pulse. The RF PULSE MOD IN connector controls the internal
pulse modulator(s) which are enabled with Options 021 and 022.
Comb Generators
U9391C 10 MHz to 26.5 GHz
U9391F 10 MHz to 50 GHz
U9391G 10 MHz to 67 GHz
PNA-X PNAPNA-L
The U9391C/F/G provides precision phase calibration, traceable
to the National Institute of Standards and Technology (NIST)
standard. It is used for nonlinear measurements with the PNA-X
nonlinear vector network analyzer (NVNA). NVNA requires two
comb generators, one is connected during measurements and
another is used only during calibration. A comb generator is also
used to characterize the VNA receivers for delay measurements
of frequency converters using PNA-X or PNA instruments and the
SMC+Phase measurement class (part of S93083B/A).
CalPod calibration refresh modules allow in-situ calibration
refreshes to be performed at the push of a button without
removing the DUT or re-connecting calibration standards.
CalPods are designed for any measurement situation where it
is desirable to ensure that a valid calibration is present before
recording measurement data. For example, they are useful for
removing environmental effects such as cable movement and
thermal-based changes of cables, connectors, and adapters, as
well as connector and switch-matrix repeatability errors. The
modules are especially useful in temperature, or thermal-vacuum
chamber testing. CalPod modules are equipped with 2.92 mm
connectors.
Keysight Software Licensing Options Provide Flexibility and Support
Projects ramp up and down, teams grow and shrink, and projects move location. In such a dynamic environment, you need flexible
licensing options that allow you to balance your project’s requirements. Whether your software will be a staple for years to come or
you have a short-term need for a leading-edge measurement application, Keysight’s licensing puts you in charge.
Choose your term. Choose your type. Keep control of your budget.
– Select a node-locked, transportable, USB portable or floating license type, depending on how much flexibility you need.
– Select a time-based or perpetual license term, depending on how long you need to use the software.
– Each license is sold with a KeysightCare software support subscription which provides technical suppor t with ensured response
time, proactive software updates, enhancements and fixes.
Choose a license term and type that best suits your requirements from the table below.
Table 1. License term
License TermOptions
PerpetualPerpetual licenses can be used indefinitely.
Time-basedTime-based licenses can be used through the term of the license (6, 12, 24, or 36 months).
Table 2. License type
License TypeDescriptions
Node lockedLicense can be used on one specified instrument/computer.
TransportableLicense can be used on one instrument/computer at a time but may be transferred to another using Keysight
Software Manager (internet connection required).
USB portableLicense can be used on one instrument/computer at a time but can be transferred to another using a certified USB
dongle (available for additional purchase, Keysight part number E8900-D10).
Floating (single site)Networked instruments/computers can access a license from a server one at a time. Multiple licenses may be
purchased for concurrent usage.
KeysightCare Software Support Subscription provides peace of mind amid evolving technologies.
– Ensure your software is always current with the latest enhancements and measurement standards.
– Gain additional insight into your measurement problems with live access to our team of technical experts.
– Stay on schedule with fast turnaround times and priority escalations when you need support.
Table 3. KeysightCare software support subscription
SubscriptionDescriptions
KeysightCare software support
subscription
Find us at www.keysight.com
Perpetual licenses are sold with a 12 (default), 24, 36, or 60-month software support subscription. Support
subscriptions may be renewed for a fee after that.
Time-based licenses include a software support subscription through the term of the license.
Page 30
Ordering Information
– Step 1. Choose your software product.
– Step 2. Choose your license term: perpetual or time based.
– Step 3. Choose your license type: node-locked, transportable, USB portable, or floating.
– Step 4. Depending on the license term, choose your support subscription duration.
License Term
ProductLicense TypePerpetualTime-based
LicenseSupport subscriptionLicense & Support subscription
z = subscription durationz = subscription duration
L 12 months (default)F 6 months
X 24 monthsL 12 months
Y 36 monthsX 24 months
Z 60 monthsY 36 months
1. USB por table license requires a certified USB dongle (available for additional purchase, Keysight part
number E8900-D10)
Find us at www.keysight.com
Page 31
PNA Family Network Analyzer Upgrade Kits
Frequency, test ports, test set and power configurations
Upgrade kits are available to add options after initial purchase. To upgrade the PNA-X/PNA/PNA-L, order the corresponding item number. The model and
serial numbers of the instrument to be retrofitted are required as part of the order. To add application software, order the appropriate standalone model
numbers shown in the tables on pages 7 and 8.
DescriptionRequired OptionFor PNA-X
Series
Frequency upgrade
1
For PNA
Series
For PNA-L
Series
User
Installable
Extend analyzer's frequency range to 13.5 GHzN5239/49BN5249BU-613N/AN5239BU-613No
Extend analyzer's frequency range to 20 GHzN5231/39BN /AN /AN5231/39BU-620 No
Extend analyzer's frequency range to 26.5 GHzN5221/41/49BN5241/49BU-626 N5221BU-626 N /ANo
Extend analyzer's frequency range to 50 GHzN5224/34/44BN5244BU-650N5224BU-650N5234BU-650No
Tes t por t s
Expand 2-ports, single source without configurable
N522xB-200N/AN522xBU-600N/ANo
test set to 4-ports
Expand 2-ports, single source with configurable test
N522 x /4xB-201N524xBU-601N522xBU-601N/ANo
set to 4-ports
Expand 2-ports, single source with configurable test
N522xB-205N/AN522xBU-605N/ANo
set and low-frequency extension to 4-ports
Expand 2-ports, single source with configurable test
N522x /4xB-217N524xBU-617N522xBU-617N/ANo
set and extended power range to 4-ports
Expand 2-ports, single source with configurable test
N522x/4x B-219N524xBU-619N522xBU-619N/ANo
set, extended power range, and bias-tees to 4-ports
Expand 2-ports, single source with configurable test
N522xB-220N/AN522xBU-620N/ANo
set, extended power range, and bias-tees to 4-ports
Expand 2-ports, internal second source with
N524xB-222N524xBU-622N/AN/ANo
configurable test set, extended power range,
combiner, and mechanical switches to 4-ports
Expand 2-ports, internal second source with
N524xB-224N524xBU-623N/AN/ANo
configurable test set, extended power range, biastees, combiner, and mechanical switches to 4-ports
Test set and power configuration
Add configurable test set, 2-portsN522xB-200N/AN522xBU-201N/ANo
Add configurable test set and source attenuators,
N523xB-200N/AN /AN523xBU-216No
2-por ts
Add low frequency extension, 2-portsN522xB/41/42B-201,
or N522xB-217, 219
N5241/42BU-205 N522xBU-205 (for
201), N522xBU-220
N/ANo
(for 217 or 219)
Add extended power range, 2-ports
Add bias-tees, 2-ports
2
2
N522 x /4xB-201N524xBU-217N522xBU-217N/ANo
N522x/4xB-217 or
N524xBU-219N522xBU-219N/ANo
N524xB-222
Add extended power range and bias tees, 2-portsN5227/47B-201N5247BU-219N5227BU-219N /ANo
Add internal 2nd source, combiner and mechanical
Add pulse modulator to internal 1st sourceN524xBU-021N522xBU-021N/AYes
Add pulse modulator to internal 2nd sourceRequires one of Options
N524xBU-022N522xBU-022N/AYes
22x, 40x, 41x, or 42x
Add IF inputsN524xBU-020N522xBU-020N/AYes
A to B model upgrades
The A to B model upgrade kit includes a new front-panel assembly
N524xAU-690N522xAU-690N523xAU-690No
with 12.1” multi-touch display, a new solid-state hard drive, and a new
instrument cover and handles with Keysight’s dark-gray color scheme
2
1. Not available on N5227/47B.
2. May also require update of CPU, SPAM, and synthesizer assemblies, supplied in separate upgrade kits.
For more information, visit na.support.keysight.com/pna
Find us at www.keysight.com
Page 33
PNA-X upgrade path
Frequency
N5241BU-626
N5244BU-650
201
205
217
219
217
219
229
1
401
417
419
417
419
429
1
601
617
619
2-ports4-ports
217/029
219/029
417/029
419/029
419
1
219
1
229
1
205
3
429
1
419
2
H
N5249BU-613
N5249BU-626
13.5 GHz
26.5GHz
43.5GHz
50GHz
67GHz
8 5 G z
.
H
422/029
423/029
419
423
1
423
1
423
419
422
224
219
222
222/029
224/029
219
224
1
224
1
622
623
229
224
224
229
429
429
423
423
425/029
425
425
2
425
4
429
4
219
2
PNA Family Network Analyzer Upgrade Kits (Continued)
Upgrade paths
PNA upgrade path
Frequency
13.5GHz
N5221BU-626
26.5GHz
1. This upgrade path only available for N5241/42/49B.
2. This upgrade path only available for N5227B and N5247B.
3. This upgrade path only available for N5241/42B.
Find us at www.keysight.com
8.5 GHz
13.5 GHz
20 GHz
Frequency
N5239BU-613
N5231BU-620
43.5GHz
N5224BU-650
50 GHz
67 GHz
N5239BU-620
2-ports4-ports
200
201
3
205
205
219
201
2
217
217
220
220
220
219
219
PNA-L upgrade path
43.5 GHz
N5234BU-650
50 GHz
600
601
617
619
620
400
401
401
417
417
419420
419
2-ports
200
216
216
405
419
420
605
405
2
420
4-ports
400
416
416
Page 34
Applications
Material measurements
The Keysight N1500A materials measurement suite streamlines
the process of measuring complex permittivity and permeability
with a network analyzer. Various type of measurements, such
as transmission line and free space, arch reflectivity, resonant
cavity, and coaxial probe are available as options. The easy-touse software guides the user through setup and measurement,
instantly converting S-parameter network analyzer data into
the data format of your choice and displaying the results within
seconds. Results can be charted in a variety of formats: [r’, [r”,
tand, µr’, µr”, tandµ, and Cole-Cole.
Signal integrity measurements
N1930B Physical Layer Test System (PLTS)
Software
The PLTS sof tware platform has become an industry standard
for calibration, measurement, and analysis of linear passive
interconnects such as cables, connectors, backplanes, and
printed circuit boards. Utilizing either a vector network
analyzer (VNA) or a time domain reflectometer (TDR), fast and
accurate measurements can be obtained without in-depth
knowledge of microwave measurement techniques. Refer to
www.keysight.com/find/plts or the technical overview (literature
number 5989-6841EN) for more details.
Multiport measurements
Multiport test sets are designed to work with the PNA family
of network analyzers to provide a single set of connections to
devices with more than four ports. Test sets come with different
port counts and frequency ranges, and are built to work with
2- or 4-port network analyzers. They are configured as switching
or extension test sets, using electro-mechanical or solid-state
switches.
Test set types: switching and extension
Switching test sets provide an economical solution for RF
applications. They are connected directly to the test ports of the
VNA, and a group of test por ts share the directional couplers
and receivers in the VNA. Extension test sets are connected to
the sources and test receivers through the configurable test
set of the VNA. They feature a directional coupler for every test
port, and all switching occurs behind the directional couplers,
providing the ultimate in flexibility, stability, and performance for
RF and microwave applications.
Switch types: electro-mechanical and solid-state
Electro-mechanical switches have less insertion loss, higher
power handling, and a more linear response compared to solidstate switches. They are recommended for testing active devices,
high-power devices, and devices that require wide dynamic
range. However, they have limited switching life (mostly 5 million
cycles) and long setting times. In contrast, solid-state switches
have unlimited switching life, very fast switching speed, and
excellent repeatability. Thus, they are often used for high-volume
S-parameter measurements of passive devices.
Test set model number
Multiport test set model numbers represent the type of test set;
note the numbering scheme below.
Note that there are some test sets that do not follow this numbering scheme such as U3022AE10, U3025AE06,
and U3025AE10, which use solid-state switches, and U3022AS66, which includes 1x6 switching test set and six
calibration distribution ports.
Find us at www.keysight.com
Page 35
Applications (Continued)
Test set options
One of the following test set options must be selected.
Standard configuration (Option 700)
– The standard configuration is the basic test set
configuration, which does not include signal conditioning
devices such as amplifiers.
Add amplifiers for improved dynamic range (Option 001)
– Option 001 adds an amplifier between each test port coupler
and the receiver switch to improve system dynamic range. It
is primarily offered for test sets with solid-state switches, to
compensate for insertion loss.
Add amplifiers and bias-tees (Option 002)
– Option 002 adds an amplifier between each test port coupler
and the receiver switch to improve system dynamic range,
and adds bias-tees for all test ports on the test set as well as
the analyzer. It is primarily offered for test sets with solidstate switches to compensate for insertion loss.
Interface kits
The interface kit includes a set of semi-rigid RF jumper cables
and two pairs of rear locking feet that connect and lock the
analyzer and the test set together. When ordering a multiport
test set, the analyzer that is used with the test set must
be specified to add one of the following interface kits. The
availability depends on the test set model. There are following
three interface kit models based on the jumper connector layouts
on the test set. Therefore, only one interface kit model (“PX”,
“PN”, or “PL”) is available on each test set. Each interface kit
model has one digit suffix indicating the connector type; 1 for
1.85 mm, 2 for 2.4 mm and 3 for 3.5 mm (or SMA).
U3 0 21PX xInterface kit for test set with jumper connectors to align
with N524xB PNA-X and N522xB PNA
U3 0 21PNxInterface kit for test set with jumper connectors to align
with E836xB/C PNA and N5230A/C-x25 2-port PNA-L
U3 0 21PL xInterface kit for test set with jumper connectors to align
with N523xA/B-416 4-port PNA-L
Option 261For use with E8361A/C 2-port PNA
Option 262For use with E8362B/C 2-port PNA, or N5230A/C-225 or
N523xA/B-216 2-port PNA-L
Option 263For use with E8363B/3C/4B/4C 2-port PNA, or
N5230A/C-425/525 2-port PNA-L
Option 430For use with N5230A/C-425/426 or N523xA/B-416
Option 242For use with N5221/22/41/42/49B-2xx 2-port PNA/PNA-X
Option 442For use with N5221/22/41/42/49B-4xx 4-port PNA /PNA-X
Option 245For use with N5224/25/44/45B-2xx 2-port PNA/PNA-X
Option 445For use with N5224/25/44/45B-4xx 4-port PNA /PNA-X
Option 247For use with N5227/47B-2xx 2-port PNA/PNA-X
Option 447For use with N5227/47B-4xx 4-port PNA/PNA-X
Millimeter-wave measurements
N5290/91A single-sweep millimeter-wave
solutions
PNA (N522xB) and PNA-X (N524xB) network analyzers can
be transformed into single-sweep solutions that operate from
900 Hz to 110 GHz (N5290A), or up to 120 GHz with over-range
capability to 125 GHz (N5291A). The N5290/91A solutions come
fully configured around the PNA/PNA-X network analyzers,
and include a millimeter-wave test set controller (N5292A),
frequency-extender modules (N5293/95AXxx), and the
necessary cables to allow users to make either 2- or 4-port
measurements over the entire frequency range. The broadband
N5290/91A millimeter-wave solutions provide high-performance
measurement capability complimented by measurement
applications from the PNA /PNA-X that include pulsed-RF, gain
compression, 4-port true-differential, scalar mixer/converter
measurements, and spectrum analysis.
Banded waveguide solutions to 1.5 THz
Banded waveguide millimeter-wave solutions cover waveguide
bands from 50 GHz to 1.5 THz. A 2- or 4-port PNA or PNA-X in
conjunction with an N5292A millimeter-wave controller (with
either a 2- or 4-port option), provides complete millimeter-wave
solutions. These systems are configured with a PNA or PNA-X
which has IF inputs (Option 020), and a configurable test set
(one of Options 201/217/219/222/224/401/417/419/422/42. In
addition, frequency-offset capability is required from one of
software models 93029/080/082/083/084/086/087/089/090x/
093/094A. When configured with the N5292A millimeter-wave
controller, a special cable adapter will be required to connect
the RF, LO, and IF signals from the banded millimeter-wave
extenders to the controller. A separate DC power supply is also
required to power the frequency extenders.
For a complete list of millimeter-wave products and options, and
ordering instructions, please refer to the N5290/91A MillimeterWave Network Analyzer Configuration Guide (5992-2179EN),
and the Banded Millimeter-Wave Network Analyzers to 1.5 THz
Technical Overview (5992-2177EN).
When ordering an additional cable set, a spare cable or rear
locking feet, refer to the multiport test set user’s guide or go to:
www.keysight.com/find/multiport
Find us at www.keysight.com
Page 36
Network analyzer
test set
Network analyzer
test set
Test port
adapter
Device
under
test
Single cable
Device
under
test
Cable set
Applications (Continued)
Measurement Accessories
A complete list of RF and microwave test accessories is available
on our Web site: www.keysight.com/find/mta
Accessories are available in these connector types: 50 Ω
Type-N, 3.5 mm, 7 mm, 2.4 mm, 2.92 mm, 1.85 mm, 1.0 mm, and
waveguide. Test port cables and a calibration kit should be added
for a complete measurement system. A verification kit is used to
verify corrected system performance.
Cables and adapter sets
Keysight of fers cables in the following types:
– Single cables in semi-rigid and flexible
– Cable sets in semi-rigid and flexible
There are also adapter sets available that protect the test port
and convert the port to the desired connector interface. These
kits contain:
– One male adapter
– One female adapter
To attain the best mechanical rigidity for device connection, use
a single cable and the appropriate special adapter set. To attain
the greatest flexibility for device connection, use a cable set.
Calibration kits
Coaxial measurements
Mechanical calibration kits include standards, such as opens,
shorts and loads, which are measured by the network analyzer
for increased measurement accuracy.
Choose a calibration kit for each connector type to be used.
Economy, includes:
– Open standards (male and female)
– Short standards (male and female)
– Fixed-termination standards (male and female)
Standard, includes the devices in the economy kit and adds:
– Sliding load standards (male and female) or a series of offset
shorts
Precision, includes the devices in the economy kit and adds:
– 50 Ω airline(s) for TRL calibration
– TRL adapters
Electronic calibration (ECal) kits replace mechanical calibration
standards with one solid-state calibration module that is
controlled by the network analyzer via USB, to present
many different impedances to the test ports. A full two-port
calibration can be performed quickly with a single connection.
This technique reduces operator errors and connector wear and
abrasion.
Find us at www.keysight.com
For more information about ECal modules, refer to the technical
overview 5963-3743E (N4690, 85090, N4430 and N7550 Series).
Waveguide measurements
For waveguide measurements, Keysight offers mechanical
calibration kits that include:
– Waveguide-to-coax adapters (X, P, K, R, Q, U, V)
– Precision waveguide section
– Flush short circuit
– Fixed terminations
– Straight section
Page 37
For devices with 1.0 mm connectors
For devices with 1.85 mm connectors
Mechanical calibration/verification kit
85059B DC to 120 GHz precision calibration kit. Includes:
– 85059-60027 1.0 mm (m) short, 1.3 mm
– 85059-60029 1.0 mm (m) short, 2.45 mm
– 85059-60031 1.0 mm (m) short, 3.326 mm
– 85059-60033 1.0 mm (m) short, 4.039 mm
– 85059-60028 1.0 mm (f) short, 1.3 mm
– 85059-60030 1.0 mm (f) short, 2.45 mm
– 85059-60032 1.0 mm (f) short, 3.326 mm
– 85059-60034 1.0 mm (f) short, 4.039 mm
– 85059-60053 1.0 mm (m) open
– 85059-60054 1.0 mm (f) open
– 85059-60019 1.0 mm (m) 50 GHz load
– 85059-60020 1.0 mm (f) 50 GHz load
– 85059-60044 1.0 mm m-m adapter
– 85059-60045 1.0 mm f-f adapter
– 85059-60046 1.0 mm m-f adapter
– 8710-2812 6 mm 4 in-lb torque wrench
– 8710-2813 14 mm 4 in-lb torque wrench
– 8710-2156 6 mm open-end wrench
Cables
– 11500I 1.0 mm (f-f) test port cable (8.8 cm)
– 11500J 1.0 mm (m-f) test port cable (16.0 cm)
– 11500K 1.0 mm (m-f) test port cable (20.0 cm)
– 11500L 1.0 mm (m-f) test port cable (24.0 cm)
Adapter set
Mechanical calibration kit
85058B standard: DC to 67 GHz. Includes:
– 85058-60101 1.85 mm (m) short 5.4 mm
– 85058-60102 1.85 mm (m) short 6.3 mm
– 85058-60103 1.85 mm (m) short 7.12 mm
– 85058-60104 1.85 mm (m) short 7.6 mm
– 85058-60105 1.85 mm (f) short 5.4 mm
– 85058-60106 1.85 mm (f) short 6.3 mm
– 85058-60107 1.85 mm (f) short 7.12 mm
– 85058-60108 1.85 mm (f) short 7.6 mm
– 85058-60109 1.85 mm male open
– 85058-60110 1.85 mm female open
– 85058-60111 1.85 mm male load
– 85058-60112 1.85 mm female load
– 85058-60113 1.85 mm (m) to 1.85 mm (m) adapter
– 85058-60114 1.85 mm (f) to 1.85 mm (f) adapter
– 85058-60115 1.85 mm (m) to 1.85 mm (f) adapter
85058E economy: DC to 67 GHz. Includes:
– 85058-60101 1.85 mm (m) short 5.4 mm
– 85058-60105 1.85 mm (f) short 5.4 mm
– 85058-60109 1.85 mm male open
– 85058-60110 1.85 mm female open
1
1
1
– 85058-60123 1.85 mm male load
– 85058-60124 1.85 mm female load
– 85058-60113 1.85 mm (m) to 1.85 mm (m) adapter
– 85058-60114 1.85 mm (f) to 1.85 mm (f) adapter
– 85058-60115 1.85 mm (m) to 1.85 mm (f) adapter
– V281C 1.0 mm(f) to V-band waveguide adapter
– V281D 1.0 mm (m) to V-band waveguide adapter
– W281C 1.0 mm (f) to W-band waveguide adapter
– W281D 1.0 mm (m) to W-band waveguide adapter
– 11920A 1.0 mm (m) to 1.0 mm (m) adapter
– 11920B 1.0 mm (f) to 1.0 mm (f) adapter
– 11920C 1.0 mm (m) to 1.0 mm (f) adapter
– 11921A 1.0 mm (m) to 1.85 mm (m) adapter
– 11921B 1.0 mm (f) to 1.85 mm (f) adapter
– 11921C 1.0 mm (m) to 1.85 mm (f) adapter
– 11921D 1.0 mm (f) to 1.85 mm (m) adapter
– 11922A 1.0 mm (m) to 2.4 mm (m) adapter
– 11922B 1.0 mm (f) to 2.4 mm (f) adapter
– 11922C 1.0 mm (m) to 2.4 mm (f) adapter
– 11922D 1.0 mm (f) to 2.4 mm (m) adapter
– 11923A 1.0 mm (f) connector launch assembly
1. For on-wafer applications, two 11500J/K /L cables are required; one
cable for each test port.
Find us at www.keysight.com
Page 38
For devices with 1.85 mm connectors (Continued)
For devices with 2.4 mm connectors
Electronic calibration kits
N4694A Microwave ECal: 10 MHz to 67 GHz, 2-ports. Includes:
– Option M0F module with: N4694-60001 1.85 mm (f) to
1.85 mm (m) ECal module
– Option 00M module with: N4694-60002 1.85 mm (m) to
1.85 mm (m) ECal module
– Option 00F module with: N4694-60003 1.85 mm (f) to
1.85 mm (f) ECal module
– Option 00A adds:
– 85058-60113 1.85 mm (m) to 1.85 mm (m) adapter
– 85058-60114 1.85 mm (f) to 1.85 mm (f) adapter
– Option 150: Replaces standard storage container with a
wooden box
N4694D 1 Microwave ECal: DC or 10 MHz to 67 GHz, 2-ports.
Includes:
– Option F0F: Both connectors are 1.85 mm female on module
– Option M0F: 1 female and 1 male 1.85 mm connector on
module
– Option M0M: Both connectors are 1.85 mm male on module
– Option 0DC: DC to 67 GHz
– Option 100: 10 MHz to 67 GHz
– Option 00A adds:
– 85058-60113 1.85 mm (m) to 1.85 mm (m) adapter
– 85058-60114 1.85 mm (f) to 1.85 mm (f) adapter
Cables
– N4697E 2 Single, flexible:
– 1.85 mm (f) to 1.85 mm (f), 96.5 cm, 38 inches
– N4697F 2 Set, flexible:
– One 1.85 mm (f) to 1.85 mm (f) cable, 62.2 cm,
24.5 inches, p/n N4697-60100
– One 1.85 mm (f) to 1.85 mm (m) cable, 62.2 cm,
24.5 inches, p/n N4697-60200
– N4421B-K67 Single, flexible: 1.85 mm (f) to 1.85 mm (m),
91.4 cm, 36 inches
Adapter set
Mechanical calibration kit
85056A standard: DC to 50 GHz. Includes:
– 00901-60003 2.4 mm (m) fixed broadband load
– 00902-60004 2.4 mm (f) fixed broadband load
– 00915-60003 2.4 mm (m) sliding load
– 00915-60004 2.4 mm (f) sliding load
– 85056-60005 2.4 mm (m) to 2.4 mm (m) adapter
– 85056-60006 2.4 mm (f) to 2.4 mm (f) adapter
– 85056-60007 2.4 mm (m) to 2.4 mm (f) adapter
– 85056-60020 2.4 mm (m) short
– 85056-60021 2.4 mm (f) short
– 85056-60022 2.4 mm (m) open
– 85056-60023 2.4 mm (f) open
– 85056D economy: DC to 50 GHz. Includes:
– 00901-60003 2.4 mm (m) fixed broadband load
– 00902-60004 2.4 mm (f) fixed broadband load
– 85056-60005 2.4 mm (m) to 2.4 mm (m) adapter
– 85056-60006 2.4 mm (f) to 2.4 mm (f) adapter
– 85056-60007 2.4 mm (m) to 2.4 mm (f) adapter
– 85056-60020 2.4 mm (m) short
– 85056-60021 2.4 mm (f) short
– 85056-60022 2.4 mm (m) open
– 85056-60023 2.4 mm (f) open
Electronic calibration kits
N4693A Microwave ECal: 10 MHz to 50 GHz, 2-ports. Includes:
– Option M0F module with: N4693-60001 2.4 mm (f) to
2.4 mm (m) ECal module
– Option 00M module with: N4693-60002 2.4 mm (m) to
2.4 mm (m) ECal module
– Option 00F module with: N4693-60003 2.4 mm (f) to
2.4 mm (f) ECal module
– Option 00A adds:
– 85056-60005 2.4 mm (m) to 2.4 mm (m) adapter
– 85056-60006 2.4 mm (f) to 2.4 mm (f) adapter
– Option 150: Replaces standard storage container with a
wooden box
– 85130H 2 1.85 mm to 1.85 mm
1. The PNA Series must have firmware revision A.12.85.00 or above for
operation with the N469xD Series ECal.
2. Special rugged female connector specifically for connecting to the
network analyzer test port, but does not mate with a standard male
connector.
Find us at www.keysight.com
N4693D 1 Microwave ECal: DC or 10 MHz to 50 GHz, 2-ports.
Includes:
– Option F0F: Both connectors are 2.4 mm female on module
– Option M0F: 1 female and 1 male 2.4 mm connector on
module
– Option M0M: Both connectors are 2.4 mm male on module
– Option 0DC: DC to 50 GHz
– Option 100: 10 MHz to 50 GHz
– Option 00A adds:
– 85056-60005 2.4 mm (m) to 2.4 mm (m) adapter
– 85058-60006 2.4 mm (f) to 2.4 mm (f) adapter
Page 39
For devices with 2.4 mm connectors (Continued)
For devices with K connectors (2.92 mm)
Cables
Note: Keysight offers the following 2.4 mm test port cables.
Adapters will be necessary when using these cables for 2.92 mm
measurements.
– 85133C 1 single, semi-rigid: 2.4 mm (f) to PSC-2.4 mm (f),
81 cm, 32 inches
– 85133D1 set, semi-rigid: One 2.4 mm (f) to 2.4 mm (m),
53 cm, 21 inches, p/n 85133-60001
– One 2.4 mm (f) to 2.4 mm (f), 53 cm, 21 inches, p/n
85133-60002
– 85133E1 single, flexible: 2.4 mm (f) to PSC-2.4 mm (f), 97 cm,
38 inches
– 85133F 1 set, flexible:
– One 2.4 mm (f) to 2.4 mm (f), 63 cm, 25 inches, p/n
85133-6 0 016
– One 2.4 mm (f) to 2.4 mm (m), 63 cm, 25 inches, p/n
8513 3- 60017
– 85133H 1 Single, flexible: 2.4 mm (f) to 2.4 mm (m), 63 cm,
25 inches
– N4421AK20 Single, flexible: 2.4 mm (f) to 2.4 mm (m),
91.4 cm, 36 inches
Adapter set
Mechanical calibration kits
85056KE01 DC to 40 GHz
For use with user supplied 2.92 mm test port cables. 2.92 mm
(K connector) calibration kit with fixed and sliding loads. The
Keysight 85056KE01 calibration kit is an ordering convenience
to allow the pass through ordering from Keysight for the Maury
8770C47 calibration kit.
85056KE02 DC to 40 GHz
For use with user supplied 2.92 mm test ports cables. 2.92 mm
(K connector) calibration kit with fixed loads only. The Keysight
85056KE02 calibration kit is an ordering convenience to allow
the pass through ordering from Keysight for the Maury 8770F47
calibration kit.
The 85056KE01 and 85056KE02 contains one NMD 2.4 mm2
(f) to 2.92 mm (f) and one NMD 2.4 mm2 (f) to 2.92 mm (m)
test port adapter to adapt the 2.4 mm test ports of the PNA to
2.92 mm. It also supplies 2.92 mm to 2.92 mm in-series adapters
(3 adapters) and a PNA Cal Coefficients on a USB stick. Users
must supply their own 2.92 mm or K-connector test port cables.
Also included is a 2.92 mm torque wrench.
– 85130E 2.4 mm 1 to 7 mm
– 85130F 2.4 mm 1 to 3.5 mm
– 85130G 2.4 mm 1 to 2.4 mm
Maury Microwave Terms and Conditions for Warranty and Return
apply. Maury Microwave Corp. calibration kits are to be returned
directly to Maury Microwave for service, repair, or calibration
issues and not to Keysight Technologies. For additional
information go to www.maurymicrowave.com.
Keysight Technologies does not guarantee the performance
of the Maury calibration kits or the system performance when
connected to Keysight Microwave PNA Series network analyzers.
1. Special rugged female connector specifically for connecting to the
network analyzer test port, but does not mate with a standard male
connector.
2. Special rugged female connector specifically for connecting to the
network analyzer test port, but does not mate with standard 2.4 mm
male connector
Find us at www.keysight.com
Page 40
For devices with K connectors (2.92 mm) (Continued)
Mechanical calibration kits, continued
Electronic calibration kits
N4692A Microwave ECal: 10 MHz to 40 GHz, 2-ports. Includes:
– Option M0F module with: N4692-60001 2.92 mm (f)
to 2.92 mm (m) ECal module
– Option 00M module with: N4692-60002 2.92 mm (m) to
2.92 mm (m) ECal module
– Option 00F module with: N4692-60003 2.92 mm (f) to
2.92 mm (f) ECal module
– Option 00A adds:
– N4692-60021 2.92 mm (m) to 2.92 mm (m) adapter
– N4692-60022 2.92 mm (f) to 2.92 mm (f) adapter
– Option 150: Replaces standard storage container with a
wooden box
N4692D 1 Microwave ECal: DC or 10 MHz to 40 GHz, 2-ports.
Includes:
– Option F0F: Both connectors are 2.92 mm female on module
– Option M0F: 1 female and 1 male 2.92 mm connector on
module
– Option M0M: Both connectors are 2.92 mm male on module
– Option 0DC: DC to 40 GHz
– Option 100: 10 MHz to 40 GHz
– Option 00A adds:
– N4692-60021 2.92 mm (m) to 2.92 mm (m) adapter
– N4692-60022 2.92 mm (f) to 2.92 mm (f) adapter
Cables
Note: Keysight offers the following 2.4 mm test port cables.
Adapters will be necessary when using these cables for 2.92 mm
measurements.
– 85133C 2 single, semi-rigid: 2.4 mm (f) to PSC-2.4 mm (f),
81 cm, 32 inches
– 85133D 2 set, semi-rigid:
– One 2.4 mm (f) to 2.4 mm (m), 53 cm, 21 inches, p/n
85133-60001
– One 2.4 mm (f) to 2.4 mm (f), 53 cm, 21 inches, p/n
85133-60002
– 85133E 2 single, flexible: 2.4 mm (f) to PSC-2.4 mm (f), 97 cm,
38 inches
– 85133F
– 85133H 2 Single, flexible: 2.4 mm (f) to 2.4 mm (m), 63 cm,
– N4421AK20 Single, flexible: 2.4 mm (f) to 2.4 mm (m),
2
set, flexible:
– One 2.4 mm (f) to 2.4 mm (f), 63 cm, 25 inches,
p/n 8 5133-60 016
– One 2.4 mm (f) to 2.4 mm (m), 63 cm, 25 inches,
p/n 85133-6 0 017
25 inches
91.4 cm, 36 inches
Adapters
1. The PNA Series must have firmware revision A.12.85.00 or above for the
operation with the N469xD Series ECal.
2. Special rugged female connector specifically for connecting to the
network analyzer test port, but does not mate with a standard male
connector.
– 11904A 2.4 mm (m) to 2.92 mm (m)
– 11904B 2.4 mm (f) to 2.92 mm (f)
– 11904C 2.4 mm (m) to 2.92 mm (f)
– 11904D 2.4 mm (f) to 2.92 mm (m)
– 11904S 2.4 mm to 2.92 mm
– Adapter set, contains 4 matched adapters
Find us at www.keysight.com
Page 41
For devices with 3.5 mm or SMA connectors
Mechanical calibration kits
85052B standard: DC to 26.5 GHz. Includes:
– 00902-60003 3.5 mm (m) fixed load
– 00902-60004 3.5 mm (f) fixed load
– 00911-60019 3.5 mm (m) sliding load
– 00911-60020 3.5 mm (f) sliding load
– 85052-60006 3.5 mm (m) short
– 85052-60007 3.5 mm (f) short
– 85052-60008 3.5 mm (m) open
– 85052-60009 3.5 mm (f) open
– 85052-60012 3.5 mm (f) to 3.5 mm (f) adapter
– 85052-60013 3.5 mm (f) to 3.5 mm (m) adapter
– 85052-60014 3.5 mm (m) to 3.5 mm (m) adapter
85052C precision TRL: DC to 26.5 GHz. Includes:
– 00902-60003 3.5 mm (m) fixed load
– 00902-60004 3.5 mm (f) fixed load
– 85052-60006 3.5 mm (m) short
– 85052-60007 3.5 mm (f) short
– 85052-60008 3.5 mm (m) open
– 85052-60009 3.5 mm (f) open
– 85052-60032 3.5 mm (f) to 3.5 mm (f) adapter
– 85052-60033 3.5 mm (m) to 3.5 mm (m) adapter
– 85052-60034 3.5 mm (f) to 3.5 mm (m) adapter
– 85052-60035 3.5 mm short TRL line
– 85052-60036 3.5 mm long TRL line
Electronic calibration kits
85093C RF ECal: 300 kHz to 9 GHz, 2-ports; Standard module
includes:
– Option M0F with: 85093-60008 3.5 mm (f) to 3.5 mm (m)
ECal module
– Option 00F module with: 85093-60010 3.5 mm (f) to
3.5 mm (f) ECal module
– Option 00M module with: 85093-60009 3.5 mm (m) to
3.5 mm (m) ECal module
– Option 00A adds:
– 85052-60012 3.5 mm (f) to 3.5 mm (f) adapter
– 85052-60014 3.5 mm (m) to 3.5 mm (m) adapter
– Option 150: Replaces standard storage container with a
wooden box
85052D economy: DC to 26.5 GHz. Includes:
– 00902-60003 3.5 mm (m) fixed load
– 00902-60004 3.5 mm (f) fixed load
– 85052-60006 3.5 mm (m) short
– 85052-60007 3.5 mm (f) short
– 85052-60008 3.5 mm (m) open
– 85052-60009 3.5 mm (f) open
– 85052-60012 3.5 mm (f) to 3.5 mm (f) adapter
– 85052-60013 3.5 mm (f) to 3.5 mm (m) adapter
– 85052-60014 3.5 mm (m) to 3.5 mm (m) adapter
Find us at www.keysight.com
Page 42
85093C-xxx mixed-connector options:
Port A optionPort B option
Type(f)(m)Type(f)(m)Type (f)(m)
3.5 mm 101 102 Type-N 50 ohm203 204 7-16 205206
N4431B Microwave ECal: 300 kHz to 13.5 GHz, 4-ports. Includes:
– Option 010 module with: N4431-60006 4 x 3.5 mm (f) ECal
Option 150: Replaces standard storage container with a wooden
box
N4690B Microwave ECal: 300 kHz to 18 GHz, 2-ports. Includes:
– Option M0F module with: N4690-60004 Type-N (f) to
Type-N (m) ECal module
– Option 00M module with: N4690-60005 Type-N (m) to
Type-N (m) ECal module
– Option 00F module with: N4690-60006 Type-N (f) to Type-N
(f) ECal module
– Option 00A adds:
– 85054-60037 Type-N (f) to Type-N (f) adapter
– 85054-60038 Type-N (m) to Type-N (m) adapter
N4690D 2 Microwave ECal: DC or 300 kHz to 18 GHz, 2-ports.
Includes:
– Option F0F: Both connectors are Type-N 50 Ω female on
module
– Option M0F: 1 female and 1 male Type-N 50 Ω connector on
module
– Option M0M: Both connectors are Type-N 50 Ω male on
module
– Option 0DC: DC to 18 GHz
– Option 003: 300 kHz to 18 GHz
– Option 00A adds:
– 85054-60037 Type-N (f) to Type-N (f) adapter
– 85054-60038 Type-N (m) to Type-N (m) adapter
Cables
Use the test port cables recommended for devices with 7 mm
connectors, and 7 mm to Type-N adapters that are from the
85054B/D Type-N calibration kit (see 7 mm connector section).
Option 150: Replaces standard storage container with a wooden
box
1. Special rugged female connector specifically for connecting to the
network analyzer test port, but does not mate with a standard male
connector.
2. The PNA Series must have firmware revision A.12.85.00 or above for the
operation with the N469xD Series ECal.
Find us at www.keysight.com
Page 44
For devices with 7 mm connectors
Adapter sets
Mechanical calibration kits
85050B standard: DC to 18 GHz. Includes:
– 00909-60008 7 mm coax termination
– 85050-60006 7 mm fixed broadband load
– 85050-80007 7 mm shor t
– 85050-80010 7 mm open
– 85050-80011 7 mm sliding load
85050C precision TRL: DC to 18 GHz. Includes:
– 00909-60008 7 mm coax termination
– 85050-60003 7 mm to 7 mm airline
– 85050-60005 7 mm to 7 mm TRL adapter
– 85050-60006 7 mm fixed broadband load
– 85050-80008 7 mm short
– 85050-80009 7 mm short collet
– 85050-80010 7 mm open
85050D economy: DC to 18 GHz. Includes:
– 85050-60006 7 mm fixed broadband load
– 85050-80007 7 mm shor t
– 85050-80010 7 mm open
Electronic calibration kits
N4696B Microwave ECal: 300 kHz to 18 GHz, 2-ports, 7 mm
connectors
Option 150: Replaces standard storage container with a wooden
box
– 85130E 2.4 mm to 7 mm
– R281A adapter (2.4 mm (f) to WR-28 waveguide adapter)
– R281B adapter (2.4 mm (m) to WR-28 waveguide adapter)
– Q281A adapter (2.4 mm (f) to WR-22 waveguide adapter)
– Q281B adapter (2.4 mm (m) to WR-22 waveguide adapter)
For devices with waveguide
Mechanical calibration kits
X Band
X11644A standard, WR-90: 8.2 to 12.4 GHz. Includes:
– 00896-60008 X-band standard section
– 00910-60003 X-band termination
– 11644-20018 X-band short
– 11644-20021 X-band shim
– X281C adapter (included in calibration kit): WR-90 to 7 mm
P Band
P11644A standard, WR-62: 12.4 to 18 GHz. Includes:
– 00896-60007 P-band standard section
– 00910-60002 P-band termination
– 11644-20017 P-band short
– 11644-20020 P-band shim
– P281C adapter (included in calibration kit): WR-62 to 7 mm
K Band
N4696D 1 Microwave ECal: DC or 300 kHz to 18 GHz, 2-ports,
7 mm connectors. Includes:
– Option 0DC: DC to 18 GHz
– Option 003: 300 kHz to 18 GHz
Cables
– 85132E single, flexible: 3.5 mm (f) to 7 mm, 97.2 cm,
38.25 inches
– 85132F set, flexible: two 3.5 mm (f) to 7 mm cables, 62.9 cm
each, 24.75 inches each 2, p/n 85132-60004
– 85133F cable set (set, flexible, 2.4 mm, 53 cm each,
21 inches each)
– 85134F cable set (set, flexible, 2.4 mm (f) to 3.5 mm (f) and
(m), 53 cm each, 21 inches each)
– 85135E single, flexible: 2.4 mm (f) to 7 mm, 96 cm, 38 inches
– 85135F set, flexible: two 2.4 mm (f) to 7 mm cables, 53 cm
each, 21 inches each, p/n 85135-60002
1. The PNA Series must have firmware revision A.12.85.00 or above for the
operation with the N469xD Series ECal.
2. Special rugged female connector specifically for connecting to the
network analyzer test port, but does not mate with a standard male
connector.
2
– K11644A standard, WR-42: 18 to 26.5 GHz. Includes:
– 00896-60006 K-band standard section
– 00910-60001 K-band termination
– 11644-20016 K-band short
– 11644-20019 K-band shim
– K281C adapter (included in calibration kit): WR-42 to 3.5 mm
(f) Option 012 WR-42 to 3.5 mm (m)
R Band
R11644A standard, WR-28: 26.5 to 40 GHz. Includes:
– 00914-20028 R-band termination
– 11644-20005 R-band short
– 11644-20003 R-band shim
– 11644-60001 R-band 10 cm straight waveguide
– 11644-60016 R-band 5 cm straight waveguide
Find us at www.keysight.com
Page 45
Q Band
Q11644A standard, WR-22: 33 to 50 GHz. Includes:
– 11644-60005 Q-band termination
– 11644-20004 Q-band short
– 11644-20001 Q-band shim
– 11644-60002 Q-band 10 cm straight waveguide
– 11644-60017 Q-band 5 cm straight waveguide
U Band
U11644A standard, WR-19: 40 to 60 GHz. Includes:
– 11644-60006 U-band termination
– 11644-20004 U-band short
– 11644-20002 U-band shim
– 11644-60003 U-band 10 cm straight waveguide
– 11644-60018 U-band 5 cm straight waveguide
V Band
V11644A standard, WR-15: 50 to 75 GHz. Includes:
– 11644-60025 V-band termination
– 11644-20015 V/W-band short
– 11644-20013 V-band shim
– 11644-60012 V-band standard section
W Band
W11644A standard, WR-10: 75 to 110 GHz.Includes:
– 11643-60026 W-band termination
– 11644-20015 V/W-band short
– 11644-20014 W-band shim
– 11644-60013 W-band standard section
Verification kits
85057B 45 MHz to 50 GHz 2.4 mm kit
Includes attenuators, airline and mismatch airline with data on a
USB drive for use in confirming calibrated system performance,
traceable to national standards. Test procedure is provided in the
service manual.
85058V 45 MHz to 67 GHz 1.85 mm kit
Includes attenuators, match thru and mismatch thru with data on
a USB drive for use in confirming calibrated system performance,
traceable to national standards. Test procedure is provided in the
service manual.
85059V 10 MHz to 110 GHz 1.0 mm kit
Includes a matched airline (85059-60048) and a mismatch airline
(85059-60047), with data on a USB drive for use in confirming
calibrated system performance traceable to national standards.
Test procedure is provided in the service manual.
General Accessories
Spare drive
– N5242-60134 Windows 7 spare drive with mounting cradle
for all N522x/3x/4xB models with 2.2 GHz CPU (version 7)
For information about spare drives for older PNA models, please
refer to the configuration guide 5990-7745EN.
1
All Keysight verification kits include:
– Precision Z0 airline or match thru
– Mismatched airline or mismatch thru
– Fixed attenuators (except 85059V)
– Traceable measured data and uncertainties
85051B 45 MHz to 18 GHz 7 mm kit
Includes attenuators, airline and mismatch airline with data on a
USB drive for use in confirming calibrated system performance,
traceable to national standards. Test procedure is provided in the
service manual.
85053B 300 kHz to 26.5 GHz 3.5 mm kit
Includes attenuators, airline and mismatch airline with data on a
USB drive for use in confirming calibrated system performance,
traceable to national standards. Test procedure is provided in the
service manual.
85055A 300 kHz to 18 GHz Type-N kit
Includes attenuators, airline and mismatch airline with data on a
USB drive for use in confirming calibrated system performance,
traceable to national standards. Test procedure is provided in the
service manual.
performance tests to verify proper instrument operation.
– USB power sensors
– U848x Series USB thermocouple power sensors
– U2020 X-Series USB peak and average power sensors
– U2000 Series USB power sensors
– U2040 X-Series USB and LAN power sensors
– Power meters
– P Series power meters (N1911A and N1912A) and all
supported sensors
– EPM Series power meters (N1913A and N1914A) and all
supported sensors
– EPM-P Series power meters (E4416A and E4417A) and all
supported sensors
– E Series power meters (E4418 and E4419) and all supported
sensors
– HP 437B/438A power meters
2
Find us at www.keysight.com
Page 46
General Accessories (Continued)
Comb generators
Two are required for NVNA. Also requires separate power supply.
– U9391C 10 MHz to 26.5 GHz comb generator
– U9391F 10 MHz to 50 GHz comb generator
– U9391G 10 MHz to 67 GHz comb generator
Amplifiers
– 83006A power amplifier, 10 MHz to 26.5 GHz, 20 dB gain,
power out: +18 dBm to 10 GHz or +16 dBm to 20 GHz or
+14 dBm to 26.5 GHz
– 83017A power amplifier, 50 MHz to 26.5 GHz, 25 dB gain,
power out: +20 dBm to 20 GHz, or +15 dBm to 26.5 GHz
– 83018A power amplifier, 2 to 26.5 GHz, 27 dB gain to 20
GHz or 23 dB to 26.5 GHz, power out: +24 dBm to 20 GHz or
+21 dBm to 26.5 GHz
– 83020A power amplifier, 2 to 26.5 GHz, 30 dB gain to
20 GHz or 27 dB to 26.5 GHz, power out: +30 dBm to 20 GHz
or +26 dBm to 26.5 GHz
– 83050A power amplifier, 2 to 50 GHz, 23 dB gain, power out:
+20 dBm to 40 GHz or +17 dBm to 50 GHz
– 83051A power amplifier, 45 MHz to 50 GHz, 23 dB gain
power out: +12 dBm to 45 GHz or +10 dBm to 50 GHz
Equipment rack accessories
– E3663AC Rail kit (included with Option 1CM and 1CP)
– 1CM042A Rack mount flange kit, for use without handles
(included with Option 1CM)
– 5063-1555 Rack mount flange kit with handles
(included with Option 1CP)
3
Monitors
Any VGA-compatible monitor can be connected directly to the
rear panel. Monitors with other video interfaces (for example,
HDMI or DisplayPort) require USB-based video adapters (must
be supplied by the user). Touch-screen monitors are supported.
Interface cables
Choose the appropriate cables to connect each peripheral to the
network analyzer.
– 10833A GPIB cable, 1.0 m (3.3 ft)
– 10833B GPIB cable, 2.0 m (6.6 ft)
– 10833D GPIB cable, 0.5 m (1.6 ft)
– 82357B GPIB to USB interface
Couplers
– 87300B coaxial coupler, 1 to 20 GHz, SMA (f), 10 dB
coupling
– 87300C coaxial coupler, 1 to 26.5 GHz, 3.5 mm (f), 10 dB
coupling
– 87301B coaxial coupler, 10 to 46 GHz, 2.92 mm (f), 10 dB
coupling
– 87301D coaxial coupler, 1 to 40 GHz, 2.4 mm (f) or optional
2.92 mm (f), 13 dB coupling
– 87301E coaxial coupler, 2 to 50 GHz, 2.4 mm (f), 10 dB
coupling
– 87310B 90o coaxial coupler, 1 to 18 GHz, SMA (f), 3 dB
coupling
Learn more at: www.keysight.com
1. All spare drives use solid-state storage. For more information, refer to
na.support.keysight.com/pna/hdnumbers.html.
2. For the latest guide to power meters and power sensors, refer to the
Keysight web site: www.keysight.com/find/powermeters.
3. 5063-1555 is a complete rack mount kit with handles. N52xxB comes
with ruggedized handles, which must be replaced with classic handles
shipped with the rack mount kit.
For more information on Keysight Technologies’ products, applications or services,
please contact your local Keysight office. The complete list is available at: