duced in any form or by any means
(including electronic storage and
retrieval or translation into a foreign
language) without prior agreement and
written consent from Keysight Technologies as governed by United States and
international copyright laws.
Manual Part Number
M9182-90001
Edition
Edition 4, November 30, 2017
Printed in:
Printed in Malaysia
Published by:
Keysight Technologies
Bayan Lepas Free Industrial Zone,
11900 Penang, Malaysia
Technology Licenses
The hardware and/or software
described in this document are furnished under a license and may be
used or copied only in accordance with
the terms of such license.
Declaration of Conformity
Declarations of Conformity for this
product and for other Keysight products may be downloaded from the
Web. Go to http://www.keysight.com/
go/conformity. You can then search by
product number to find the latest Declaration of Conformity.
U.S. Government Rights
The Software is “commercial computer
software,” as defined by Federal Acquisition Regulation (“FAR”) 2.101. Pursuant to FAR 12.212 and 27.405-3 and
Department of Defense FAR Supplement (“DFARS”) 227.7202, the U.S.
government acquires commercial computer software under the same terms
by which the software is customarily
provided to the public. Accordingly,
Keysight provides the Software to U.S.
government customers under its standard commercial license, which is
embodied in its End User License
Agreement (EULA), a copy of which can
be found at http://www.keysight.com/
find/sweula. The license set forth in the
EULA represents the exclusive authority
by which the U.S. government may use,
modify, distribute, or disclose the Software. The EULA and the license set
forth therein, does not require or permit, among other things, that Keysight:
(1) Furnish technical information
related to commercial computer software or commercial computer software
documentation that is not customarily
provided to the public; or (2) Relinquish
to, or otherwise provide, the government rights in excess of these rights
customarily provided to the public to
use, mod ify, reproduce, release, perform, display, or disclose commercial
computer software or commercial computer software documentation. No
additional government requirements
beyond those set forth in the EULA
shall apply, except to the extent that
those terms, rights, or licenses are
explicitly required from all providers of
commercial computer software pursuant to the FAR and the DFARS and are
set forth specifically in writing elsewhere in the EULA. Keysight shall be
under no obligation to update, revise or
otherwise modify the Software. With
respect to any technical data as
defined by FAR 2.101, pursuant to FAR
12.211 and 27.404.2 and DFARS
227.7102, the U.S. government
acquires no greater than Limited Rights
as defined in FAR 27.401 or DFAR
227.7103-5 (c), as applicable in any
technical data.
Warranty
THE MATERIAL CONTAINED IN THIS
DOCUMENT IS PROVIDED “AS IS,”
AND IS SUBJECT TO BEING
CHANGED, WITHOUT NOTICE, IN
FUTURE EDITIONS. FURTHER, TO THE
MAXIMUM EXTENT PERMITTED BY
APPLICABLE LAW, KEYSIGHT DISCLAIMS ALL WARRANTIES, EITHER
EXPRESS OR IMPLIED, WITH REGARD
TO THIS MANUAL AND ANY INFORMATION CONTAINED HEREIN, INCLUDING BUT NOT LIMITED TO THE
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE. KEYSIGHT
SHALL NOT BE LIABLE FOR ERRORS
OR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION
WITH THE FURNISHING, USE, OR
PERFORMANCE OF THIS DOCUMENT
OR OF ANY INFORMATION CONTAINED HEREIN. SHOULD KEYSIGHT
AND THE USER HAVE A SEPARATE
WRITTEN AGREEMENT WITH WARRANTY TERMS COVERING THE MATERIAL IN THIS DOCUMENT THAT
CONFLICT WITH THESE TERMS, THE
WARRANTY TERMS IN THE SEPARATE
AGREEMENT SHALL CONTROL.
Safety Information
A CAUTION notice denotes a hazard. It
calls attention to an operating procedure, practice, or the like that, if not
correctly performed or adhered to,
could result in damage to the product
or loss of important data. Do not proceed beyond a CAUTION notice until
the indicated conditions are fully
understood and met.
A WARNING notice denotes a hazard. It
calls attention to an operating procedure, practice, or the like that, if not
correctly performed or adhered to,
could result in personal injury or death.
Do not proceed beyond a WARNING
notice until the indicated conditions are
fully understood and met.
2Keysight M9180 Series Startup Guide
Page 3
Trademarks
Microsoft® and Windows® are U.S. registered trademarks of Microsoft
Corporation.
MATLAB is a U.S registered Trademark of The MathWorks, Inc.
PXI is a registered trademark of the PXI Systems Alliance.
Visual Studio is a registered trademark of Microsoft Corporation in the United
States.
LabVIEW is a registered trademark of National Instruments.
Keysight M9180 Series Startup Guide3
Page 4
Safety Symbols
The following symbols on the instrument and in the documentation indicate
precautions which must be taken to maintain safe operation of the instrument.
Caution, risk of danger (refer to this
manual for specific Warning or Caution
information)
Alternating current (AC)Frame or chassis (ground) terminal
Direct current (DC)
Indicates that antistatic precautions
should be taken.
Earth (ground) terminal
Standby Power. Unit is not completely
disconnected from AC mains when
power switch is in standby position
4Keysight M9180 Series Startup Guide
Page 5
Safety Considerations
Read the information below before using this instrument.
The following general safety precautions must be observed during all phases of
operation, service, and repair of this instrument. Failure to comply with these
precautions or with specific warnings elsewhere in this manual violates safety
standards for design, manufacture, and intended use of the instrument. Keysight
Technologies assumes no liability for the customer’s failure to comply with these
requirements.
General
Do not use this product in any manner not specified by the manufacturer. The
protective features of this product must not be impaired if it is used in a manner
specified in the operation instructions.
Before applying power
Verify that all safety precautions are taken. Make all connections to the unit before
applying power. Note the instrument's external markings described under Safety
Symbols.
Ground the instrument
PXI chassis are provided with a grounding-type power plug. The instrument
chassis and cover must be connected to an electrical ground to minimize shock
hazard. The ground pin must be firmly connected to an electrical ground (safety
ground) terminal at the power outlet. Any interruption of the protective
(grounding) conductor or disconnection of the protective earth terminal will cause
a potential shock hazard that could result in personal injury.
Do not operate in an explosive atmosphere
Do not operate the Keysight module/chassis in the presence of flammable gases
or fumes.
Keysight M9180 Series Startup Guide5
Page 6
Do not operate near flammable liquids
Do not operate the Keysight module/chassis in the presence of flammable liquids
or near containers of such liquids.
Do not remove instrument cover
Only qualified, service-trained personnel who are aware of the hazards involved
should remove instrument covers. Always disconnect the power cable and any
external circuits before removing the instrument cover.
Cleaning
Clean the outside of the Keysight module, chassis, or accessory with a soft,
lint-free, slightly dampened cloth. Do not use detergent or chemical solvents.
Keep away from live circuits
Operating personnel must not remove equipment covers or shields. Procedures
involving the removal of covers and shields are for use by service-trained
personnel only. Under certain conditions, dangerous voltages may exist even with
the equipment switched off. To avoid dangerous electrical shock, DO NOT perform
procedures involving cover or shield removal unless you are qualified to do so.
Do not operate damaged equipment
Whenever it is possible that the safety protection features built into this product
have been impaired, either through physical damage, excessive moisture, or any
other reason, REMOVE POWER and do not use the product until safe operation
can be verified by service-trained personnel. If necessary, return the product to an
Keysight Technologies Sales and Service Office for service and repair to ensure
the safety features are maintained.
6Keysight M9180 Series Startup Guide
Page 7
Do not block the primary disconnect
WARNING
The primary disconnect device is the appliance connector/power cord when a
chassis used by itself, but when installed into a rack or system the disconnect
may be impaired and must be considered part of the installation.
Do not modify the instrument
Do not install substitute parts or perform any unauthorized modification to the
product. Return the product to an Keysight Sales and Service Office to ensure that
safety features are maintained.
In case of damage
Instruments that appear damaged or defective should be made inoperative and
secured against unintended operation until they can be repaired by qualified
service personnel.
– IEC Measurement Category II. The HI and LO input terminals may be
connected to mains in IEC Category II installations for line voltages up to
300 VAC. To avoid the danger of electric shock, do not connect the inputs
to mains for line voltages above 300 VAC. The M9181A DMM is limited to
240 VAC. See IEC Measurement Category II overvoltage protection below
for further information.
Keysight M9180 Series Startup Guide7
– The DMM comes installed with four shields (bottom, top and two edge
strips). These shields must be in place for performance and safety
reasons. Removal or improper assembly of these shields can result in
lethal voltages occurring within your PC. Be sure to check your
installation before closing the cover on your chassis.
Page 8
WARNING
– During and after installing your DMM, verify that no loose wires or ribbon
NOTE
cables infringe upon any of the internal circuits of the DMM, as this may
apply measurement voltages to your chassis, causing electrocution and/
or damage to your chassis!
– To avoid shock hazard, install the DMM only into a chassis that has its
power connector connected to a power receptacle with an earth safety
ground.
– When making any measurements above 50 VDC or 40 VAC, only use
safety test leads, such as Keysight test leads.
IEC Measurement Category II overvoltage protection
To protect against the danger of electric shock, the Keysight M9180 Series digital
multimeters (DMMs) provide overvoltage protection for line-voltage mains
connections meeting both of the following conditions:
The HI and LO input terminals are connected to the mains under Measurement
Category II conditions, defined below,
and
The mains are limited to a maximum line voltage of 300 VAC (240 VAC for the
M9181A).
IEC Measurement Category II includes electrical devices connected to mains at an
outlet on a branch circuit. Such devices include most small appliances, test
equipment, and other devices that plug into a branch outlet or socket. The M9180
Series DMMs may be used to make measurements with the HI and LO inputs
connected to mains in such devices, or to the branch outlet itself (up to 300 VAC,
or 240 VAC for the M9181A). However, the DMMs may not be used with their HI
and LO inputs connected to mains in permanently installed electrical devices such
as the main circuit-breaker panel, sub-panel disconnect boxes, or permanently
wired motors. Such devices and circuits are subject to overvoltages that may
exceed the protection limits of the M9180 Series.
The M9182A and M9183 can measure voltages up to 330 VAC in circuits that are
isolated from mains (CAT I).
8Keysight M9180 Series Startup Guide
Page 9
Regulatory Markings
ISM
The CE mark is a registered trademark
of the European Community. This CE
mark shows that the product complies
with all the relevant European Legal
Directives.
ICES/NMB-001 indicates that this ISM
device complies with the
Canadian ICES-001.
Cet appareil ISM est conforme a la
norme NMB-001 du Canada.
RECOGNIZED COMPONENT
Conforms to UL STD 61010-1:
Certified to CSA STD C22.2. No.
61010-1
This is the symbol for an Industrial,
Scientific, and Medical Group 1 Class A
product.
The RCM mark is a registered
trademark of the Australian
Communications and Media Authority.
Keysight M9180 Series Startup Guide9
Page 10
Waste Electrical and Electronic Equipment (WEEE) Directive
This instrument complies with the WEEE Directive marking requirement. This
affixed product label indicates that you must not discard this electrical or
electronic product in domestic household waste.
Product category
With reference to the equipment types in the WEEE directive Annex 1, this
instrument is classified as a “Monitoring and Control Instrument” product.
The affixed product label is as shown below.
Do not dispose in domestic household waste.
To return this unwanted instrument, contact your nearest Keysight Service Center,
or visit http://about.keysight.com/en/companyinfo/environment/takeback.shtml
for more information.
Sales and Technical Support
To contact Keysight for sales and technical support, refer to the support links on
the following Keysight websites:
– www.keysight.com/find/pxi-dmm
(product-specific information and support, software and documentation
updates)
– www.keysight.com/find/assist
(worldwide contact information for repair and service)
– www.keysight.com/find/tips
(information on preventing damage to your Keysight equipment)
The Keysight M9180 Series digital multimeters (DMM) deliver high-performance
measurement with fast, easy installation and configuration via the Keysight
Connection Expert and a soft front panel (SFP).
Keysight PXI 6½ digit DMM Modules
– M9181A, PXI 6½ digit Digital Multimeter, basic features
– M9182A, PXI 6½ digit Digital Multimeter, high performance
– M9183A, PXI 6½ digit Digital Multimeter, enhanced high performance
Keysight also supplies software drivers that allow you to support the modules in
many popular PXI chassis and programming environments. The soft front panel
allows you to exercise the DMMs.
This Startup Guide, and the documentation listed below, can be found on the
Keysight M9180 Series PXI Digital Multimeters Software and Product Information
CD that came with your module.
– Help file for the Keysight PXI DMM Modules Soft Front Panel
– Help file for the Keysight PXI DMM Modules IVI-C/IVI-COM device drivers
– Help file for the Keysight PXI DMM Modules LabVIEW G device drivers
– Keysight M9182A/M9183 PXI DMM Modules data sheet
For the latest specifications, software, and example programs, please see the
Keysight web site at: www.keysight.com/find/pxi-dmm.
Keysight M9180 Series Startup Guide13
Page 14
Step 1: Unpack and Inspect the Module
CAUTION
CAUTION
NOTE
Step 1: Unpack and Inspect the Module
Keysight’s PXI DMMs are shipped in materials which prevent static electricity
damage. The modules should only be removed from the packaging in an
anti-static area ensuring that correct anti-static precautions are taken. Store
all modules in anti-static envelopes when not in use.
ESD
Electrostatic discharge (ESD) can damage or destroy electronic components. All
work on electronic assemblies should be performed at a static-safe work station.
Purchase acceptable ESD accessories from your local supplier.
– Conductive table-mat and wrist-strap combination.
– Conductive floor-mat and heel-strap combination.
Both types, when used together, provide a significant level of ESD protection. Of
the two, only the table-mat and wrist-strap combination provides adequate ESD
protection when used alone. To ensure user safety, the static-safe accessories
must provide at least 1 MΩ of isolation from ground.
Inspect for damage
After unpacking the DMM, carefully inspect it for any shipping damage. Report
any damage to the shipping agent immediately, as such damage is not covered by
the warranty.
To avoid damage when handling a module; do not touch exposed connector
pins.
Information on preventing damage to your Keysight equipment can be found at
www.keysight.com/find/tips.
14Keysight M9180 Series Startup Guide
Page 15
Step 1: Unpack and Inspect the Module
NOTE
Return the module for service
Should it become necessary to return an Keysight DMM for repair or service,
follow the steps below:
1 Review the warranty information shipped with your product.
2 Contact Keysightto obtain a Return Material Authorization (RMA) and return
address. For assistance finding Keysight contact information go to
www.keysight.com/find/assist (worldwide contact information for repair and
service) or refer to the Support information on the product web page at:
www.keysight.com/find/pxi-dmm.
3 Write the following information on a tag and attach it to the malfunctioning
equipment.
– Name and address of owner. A Post Office box is not acceptable as a return
address.
– Product model number (for example, M9182A)
– Product serial number (for example, MYXXXXXXXX). The serial number
label is located on the side of the module.
– A description of failure or service required.
4 Carefully pack the module in its original ESD bag and packing carton. If the
original carton is not available, use bubble wrap or packing peanuts and place
the instrument in a sealed container and mark the container “FRAGILE.”
5 On the shipping label, write ATTENTION REPAIR DEPARTMENT and the RMA
number.
If any correspondence is required, refer to the product by serial number and
model number.
Keysight M9180 Series Startup Guide15
Page 16
Step 2: Verify Shipment Contents
Step 2: Verify Shipment Contents
Your shipment should have included the following:
– The Keysight PXI DMM module that you ordered.
– This document (Keysight M9180 Series PXI 6½ Digit Digital Multimeters
Startup Guide) in hard copy.
–The Keysight M9180 Series PXI Digital Multimeters Software and Product
Information CD (M9182-10001). This CD contains software, drivers and all
product printed documentation in PDF format for the PXI DMMs.
–An Automation-Ready CD with Keysight IO Libraries Suite
– Any other accessories that you ordered (cables, connectors, etc.).
16Keysight M9180 Series Startup Guide
Page 17
Step 3: Install the Software on the Controller
M9045A
PCIe Laptop
Adapter
M9021A
System Interface
Module
M9018B
18 Slot PXIe Chassis
Y1202A
PCIe Cable
Y1200A
PCIe Cable
PXIe Embedded
System Controller
M9047A
PCIe Desktop
Adapter
Desktop PC/
Rackmount PC
Laptop PC
System Controller
System Chassis:
System Interface:
NOTE
Step 3: Install the Software on the Controller
The following illustration shows typical installations.
Do not install the PXI modules in the PXI chassis yet! You must install the
software prior to installing the modules in the chassis so that Keysight IO
Libraries Connection Expert finds them.
Keysight M9180 Series Startup Guide17
Page 18
Step 3: Install the Software on the Controller
System requirements
The following table lists the minimum system requirements for Keysight IO
Libraries. In general, any x86 or x64 (except Itanium) should work but there may
be a significant decrease in performance.
Operating
System
Processor
Speed
Available
memory
Available
hard disk
space
Minimum
display
[a] Because of the installation procedure, less memory may be required for operation than is required for installation.
Windows 7 SP1 (32- and 64-bit)
1 GHz 32-bit (x86),
1 GHz 64-bit (x64),
no support for Itanium64
1 GB minimum1 GB minimum1 GB minimum
1.5 GB available hard disk space,
includes:
– 1 GB available for Microsoft.NET
[a]
Framework 4.6
– 100MB for Keysight IO Libraries
Suite
1024x768, 96 or 120 DPI1024x768, 96 or 120 DPI1024x768, 96 or 120 DPI
Windows 8 and Windows 8.1 (32and 64-bit)
1 GHz 32-bit (x86),
1 GHz 64-bit (x64),
no support for Itanium64 or
Windows 8 RT
2.5 GB available hard disk space,
includes:
– 2 GB available for Microsoft.NET
Framework 3.5 and 4.6
– 100MB for Keysight IO Libraries
Suite
Windows 10 (32- and 64-bit)
1 GHz 32-bit (x86),
1 GHz 64-bit (x64),
no support for Itanium64 or
Windows 8 RT
2.5 GB available hard disk space,
includes:
– 2 GB available for Microsoft.NET
Framework 3.5 and 4.6
– 100MB for Keysight IO Libraries
Suite
18Keysight M9180 Series Startup Guide
Page 19
Power the controller
NOTE
– If you are using a desktop, laptop, or rackmount PC as a controller:
1 Install any peripheral devices in the PC (e.g., PCIe Interface adapters, etc.).
Follow the manufacturers instructions.
2 Power up the computer.
3 Choose the automatic option for any “Found Hardware” dialogs
– If you are using a PXI embedded computer as the controller:
1 Install the embedded computer module into the PXI chassis following the
manufacturer’s instructions.
2 Connect peripherals such as a mouse, keyboard, monitor, CD-ROM drive,
etc.
3 Power up the chassis.
4 Choose the automatic option for any “Found Hardware” dialogs
Install Keysight IO Libraries Suite
Step 3: Install the Software on the Controller
Install Keysight IO Library Suite (IOLS), which includes the Keysight Connection
Expert, the IVI Shared Components, and the VISA Shared Components.
Keysight IO Libraries must be installed prior to installing and running any other
software and prior to powering up the chassis.
1 Insert the Automation-Ready CD with Keysight IO Libraries Suite into the
CD-ROM drive of your controller.
– Wait a few seconds for the auto-run window to appear.
– If the auto-run window does not appear automatically:
–Click Start > Run...
–Type:
<drive>:Autorun\IOLibraries.hta
where <drive> is your CD drive letter.
Keysight M9180 Series Startup Guide19
Page 20
Step 3: Install the Software on the Controller
NOTE
2 Follow the installation instructions that came with the Keysight IO Libraries
Suite.
If the IVI Shared Components and VISA Shared Components are not already
installed on your PC, Keysight IO Libraries Suite installs them in the standard,
default locations. If the IVI Shared Components and VISA Shared Components
are already installed, the Keysight IO Libraries Suite installer will upgrade them
to the latest version, using the same installation location used by the older
version. If this is a first-time installation, you will be able to select installation
locations for these components by choosing a Custom Installation.
Install instrument drivers and Soft Front Panel
1 Insert the Keysight M9180 Series PXI Digital Multimeters Software and
Product Information CD into the CD-ROM drive of your PC.
Wait a few seconds for the auto-run window to appear. If the auto-run window
does not appear automatically:
– Click Start > Run...
– Type:
<drive>:Autorun.exe where <drive> is your CD drive letter.
2 Select the Install Driver Software link. Follow the installer prompts. Accept all
of the default directories specified during installation if prompted.
3 After the Welcome screen, you will be prompted three times for license
agreements. The software installer installs the following drivers:
– Keysight Mod ular Software License Agreement. The installer program
installs the Soft Front Panel (SFP) application and other object code to
connect to the switches. Accept the license terms and click Next.
– Keysight IVI Driver Source Code License Agreement. The Interchangeable
Virtual Instrument (IVI) driver is available for programming the Keysight
switch modules using Microsoft
®
Studio
Instruments
, C, C++, C#, Visual Basic), Keysight VEE, MATLAB®, or National
®
LabVIEWTM. Accept the license terms and click Next.
®
development environments (e.g., Visual
– Keysight Software License Agreement for drivers for use with LabVIEW
Software. The LAbVIEW driver provides access to the functionality of the
switches through LabVIEW VIs. This driver works in National Instruments
20Keysight M9180 Series Startup Guide
Page 21
Step 3: Install the Software on the Controller
NOTE
LabVIEW development environments. Before this driver can be installed,
your computer must already have the IVI Shared Components installed.
Accept the license terms and click Next.
Installing Keysight IO Libraries also installs the IVI Shared Components. The IVI
Shared Components are required before IVI drivers (e.g., IVI-COM, IVI-C) can be
installed from the product reference CD.
4 Next, the installer indicates the LabVIEW installations found on your host
computer. Click Next.
5 After accepting the licenses, the driver software is ready to be installed on your
host computer. Click Install.
6 The installation program will take several minutes to finish the installation; do
not cancel the installation process. When the installation wizard is finished,
you will be prompted to reboot your host computer. Do not reboot the host
computer at this time! Select “No, I will restart my computer later.” Power
down the host computer.
Keysight M9180 Series Startup Guide21
Page 22
Step 4: Connect the PC to the PXI Chassis
NOTE
Step 4: Connect the PC to the PXI Chassis
To ensure proper operation and the PC’s ability to enumerate all of the PXI
modules, you must use an approved embedded PC, desktop PC, or laptop PC
along with approved PCIe adapter and cable.
Using a remote PC
Refer to the following figure. Make certain that both the PC and the PXI chassis
are turned off. If you are using the M9018A 18 Slot PXIe chassis, install the
Keysight M9021 System Interface Module in the chassis.
– If you are using a desktop or rackmount PC, install the M9047 PCIe Desktop
Adapter in the PC. With an Keysight Y1202 cable, connect the adapter to the
System Interface module.
– If you are using a laptop PC then install the M9045 PCIe ExpressCard Adapter
in the laptop PC. With an Keysight Y1200 cable, connect the adapter to the
System Interface module or the embedded computer on the PXI chassis.
22Keysight M9180 Series Startup Guide
Page 23
Step 4: Connect the PC to the PXI Chassis
M9045A
PCIe Laptop
Adapter
M9021A
System Interface
Module
M9018B
18 Slot PXIe Chassis
Y1202A
PCIe Cable
Y1200A
PCIe Cable
PXIe Embedded
System Controller
M9047A
PCIe Desktop
Adapter
Desktop PC/
Rackmount PC
Laptop PC
System Controller
System Chassis:
System Interface:
Using an embedded computer
Refer to the figure above. If you are using an embedded controller in the PXI
chassis, you should have installed it prior to installing the Keysight IO Libraries
and instrument drivers. No cables or other adapters are required. After
installation, proceed to Step 5: Install the DMM Modules in the PXI Chassis.
Keysight M9180 Series Startup Guide23
Page 24
Step 5: Install the DMM Modules in the PXI Chassis
CAUTION
NOTE
Step 5: Install the DMM Modules in the PXI Chassis
– PXI hardware does not support “hot-swap” capabilities (changing
modules while power is applied to the chassis).
– Before installing Keysight PXI Modules into the chassis, the chassis must
be powered off and unplugged to prevent damage to the PXI module.
These modules can be used in a chassis with a cPCI, PXI-1, or PXIh
chassis peripheral slot.
The module can be installed in any standard PXI slot marked
with a peripheral slot compatibility image (a circle containing
the slot number).
The module can also be installed in any hybrid PXI slot marked
with a peripheral slot compatibility image (the letter "H" and a
solid circle containing the slot number).
1 Make sure the PXI chassis power is turned off.
2 If the chassis has multiple fan speed settings, ensure that the fans are set to
automatic. Do not set the fan speed to low or turn them off.
3 Position the chassis so that there is ample space between the chassis fan
intake and exhaust vents. Blockage by walls or obstructions affects the air flow
needed for cooling. (Refer to the chassis documentation for more information
about cooling).
4 Holding the PXI module by the injector/ejector handle, slide it into an available
PXI (or hybrid) slot, as shown in the following figure.
– Install the module into the PXI slot of the chassis by placing the module
card edges into the front module guides (top and bottom).
– Slide the module to the rear of the chassis and assure that the injector/
ejector handle is pushed down in the unlatched (downward) position.
24Keysight M9180 Series Startup Guide
Page 25
Step 5: Install the DMM Modules in the PXI Chassis
– Slide the module completely into the chassis. When you begin to feel
resistance, push up on the injector/ejector handle to fully seat the module
into the chassis.
5 Latch the module by pulling up on the injector/ejector handle and secure the
front panel to the chassis using the module front-panel mounting screws.
6 Tighten the screws on the module (or remote controller) front panel.
Performance may suffer if the screws are not securely tightened.
7 Install all chassis covers, filler panels, and air scoops after installing the
module. Missing filler panels may disrupt necessary air circulation in the
chassis.
8 If you are using a remote controller, connect the Cable Interface Card in the
chassis to host computer.
9 Plug in and power up the PXI chassis. Verify that the chassis fans are operating
and free of obstructions that may restrict airflow.
10 If you are using a remote controller (rackmount, desktop, or laptop PC), reboot
the controller.
Keysight M9180 Series Startup Guide25
Page 26
Step 6: Verify Operation of the DMM
NOTE
Step 6: Verify Operation of the DMM
Run Keysight IO Libraries Connection Expert
If Keysight Connection Expert is already running on the controller, click the
Refresh All button to identify any hardware you have just installed or
re-connected.
If Connection Expert is not already running, run it now to verify your I/O
configuration: In the Windows Notification area, click the IO icon ( ), then click
Keysight Connection Expert.
Locate your interfaces and instruments in the Keysight Connection Expert
Explorer Pane. Click on them to see their properties (displayed in the right-hand
pane). Observe their state, also displayed in the right-hand pane -- if
communication to the interface or instrument has been successfully established,
it will be in the Verified state, denoted by a green check mark.The following
illustration shows the Keysight Connection Expert.
26Keysight M9180 Series Startup Guide
Page 27
Step 6: Verify Operation of the DMM
You can use the Soft Front Panel (SFP) software to open and close the relays and
verify operation of the PXI DMM modules. The Soft Front Panel Software was
installed as part of the Software installation process.
Refer to the SFP help file on the Keysight M9180 Series PXI Digital Multimeters Software and Product Information CD for specific detailed information on using
the SFP. The following graphic shows an example of the SFP for the DMM
modules.
Verify operation
To verify basic operational readiness, use the Soft Front Panel software to
configure and take a few basic measurements. For example, you could apply a
short across the input terminals and take a DCV measurement or 2W Ω
measurement. Both measurements should report values near zero. Module
specifications are guaranteed by design.
Conduct self test
Use the Utility menu on the Soft Front Panel software to run a module self test.
Keysight M9180 Series Startup Guide27
Page 28
Step 6: Verify Operation of the DMM
28Keysight M9180 Series Startup Guide
Page 29
Module Functional Description
The Keysight M9180 Series DMM modules conform to the single slot, 3U height
(128 mm) Eurocard standard. These modules meet PXI Specification 2.2. Local
bus, trigger bus, and star trigger are not included. The modules also include:
– CPCI Ejector Handle
– The front panel secures to the chassis by two M2.5 × 6 mm pan-head
Posi-drive screws.
There are no user serviceable or field replaceable components on these modules.
Module Functional Description
Keysight M9180 Series Startup Guide29
Page 30
Module Functional Description
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.
30Keysight M9180 Series Startup Guide
Page 31
This information is subject to change
without notice. Always refer to the
Keysight website for the latest
revision.