Keysight M8195A Getting Started Manual

Getting Started Guide
Keysight M8195A Arbitrary Waveform Generator
M
Notices
CAUTION
WARNING
© Keysight Technologies, Inc. 2014
No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Keysight Technologies, Inc. as governed by United States and international copyright laws.
Manual Part Number
M8195-91010
Edition
Second edition, October 2014
Keysight Technologies,
Deutschland GmbH
Herrenberger Str. 130
71034 Böblingen, Germany
For Assistance and Support
http://www.keysight.com/find/assist
Limitation of Warranty
The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by Buyer, Buyer-supplied software or interfacing, unauthorized modification or misuse, operation outside of the environmental specifications for the product, or improper site preparation or maintenance. No other warranty is expressed or implied. Keysight Technologies specifically disclaims the implied warranties of Merchantability and Fitness for a Particular Purpose.
ESD sensitive device
All front-panel connectors of the M8195A are sensitive to Electrostatic discharge (ESD). We recommend to operate the instrument in an electrostatic safe environment.
There is a risk of instrument malfunction when touching a connector.
Please follow this instruction:
Before touching the front-panel connectors, discharge yourself by touching the properly grounded mainframe.
Warranty
THE MATERIAL CONTAINED IN THIS
DOCUMENT IS PROVIDED “AS IS,”
AND IS SUBJECT TO BEING CHANGED, WITHOUT NOTICE, IN FUTURE EDITIONS. FURTHER, TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, KEYSIGHT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, WITH REGARD TO THIS MANUAL AND ANY INFORMATION CONTAINED HEREIN, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. KEYSIGHT SHALL NOT BE LIABLE FOR ERRORS OR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, USE, OR PERFORMANCE OF THIS DOCUMENT OR OF ANY INFORMATION CONTAINED HEREIN. SHOULD KEYSIGHT AND THE USER HAVE A SEPARATE WRITTEN AGREEMENT WITH WARRANTY TERMS COVERING THE MATERIAL IN THIS DOCUMENT THAT CONFLICT WITH THESE TERMS, THE WARRANTY TERMS IN THE SEPARATE AGREEMENT SHALL CONTROL.
Technology Licenses
The hardware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license.
Restricted Rights Legend
If software is for use in the performance of a U.S. Government prime contract or subcontract,
Software is delivered and licensed as
“Commercial computer software” as
defined in DFAR 252.227-7014 (June
1995), or as a “commercial item” as
defined in FAR 2.101(a) or as
“Restricted computer software” as
defined in FAR 52.227-19 (June 1987) or any equivalent agency regulation or contract clause. Use, duplication or disclosure of Software is subject to
Keysight Technologies’ standard
commercial license terms, and non­DOD Departments and Agencies of the U.S. Government will receive no greater than Restricted Rights as defined in FAR 52.227-19(c)(1-2) (June 1987). U.S. Government users will receive no greater than Limited Rights as defined in FAR 52.227-14 (June 1987) or DFAR 252.227-7015 (b)(2) (November 1995), as applicable in any technical data.
Safety Notices
A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met.
A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met.
General Safety
Precautions
The following general safety precautions must be observed during all phases of operation of this instrument. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the instrument. For safe operation the general safety precautions for the M9502A and M9505A AXIe chassis, must be followed. See: http://www.keysight.com/find/M9505A Keysight Technologies Inc. assumes no liability for the customer's failure to comply with these requirements. Before operation, review the instrument and manual for safety markings and instructions. You must follow these to ensure safe operation and to maintain the instrument in safe condition.
Initial Inspection
Inspect the shipping container for damage. If there is damage to the container or cushioning, keep them until you have checked the contents of the shipment for completeness and verified the instrument both mechanically and electrically. The Performance Tests give procedures for checking the operation of the instrument. If the contents are incomplete, mechanical damage or defect is apparent, or if an
instrument does not pass the operator’s checks, notify the nearest Keysight
Technologies Sales/Service Office.
WARNING To avoid hazardous electrical shock, do not perform electrical tests when there are signs of shipping damage to any portion of the outer enclosure (covers, panels, etc.).
General
This product is a Safety Class 3 instrument. The protective features of this product may be impaired if it is used in a manner not specified in the operation instructions.
Environment
Conditions
This instrument is intended for indoor use in an installation category II, pollution degree 2 environment. It is designed to operate within a temperature range of 0 °C – 40 °C (32 °F – 105 °F) at a maximum relative humidity of 80% and at altitudes of up to 2000 meters.
This module can be stored or shipped at temperatures between -40 °C and +70 °C. Protect the module from temperature extremes that may cause condensation within it.
Before Applying Power
Verify that all safety precautions are taken including those defined for the mainframe.
Line Power
Requirements
The Keysight M8190A operates when installed in an Keysight AXIe mainframe.
Do Not Operate in an
Explosive Atmosphere
Do not operate the instrument in the presence of flammable gases or fumes.
Do Not Remove the
Instrument Cover
Operating personnel must not remove instrument covers. Component replacement and internal adjustments must be made only by qualified personnel. Instruments that appear damaged or defective should be made inoperative and secured against unintended operation until they can be repaired by qualified service personnel.
Safety Summary
Symbol
Description
Indicates warning or caution. If you see this symbol on a product, you must refer to the manuals for specific Warning or Caution information to avoid personal injury or damage to the product.
C-Tick Conformity Mark of the Australian ACA for EMC compliance.
CE Marking to state compliance within the European Community: This product is in conformity with the relevant European Directives.
General Recycling Mark
Symbol
Description
This product complies with the WEEE Directive (2002/96/EC) marketing requirements. The affixed label indicates that you must not discard this electrical/electronic product in domestic household waste.
Product category: With reference to the equipment types in the WEEE Directive Annexure I, this product is classed as a “Monitoring and Control instrumentation” product.
Do not dispose in domestic household waste.
To return unwanted products, contact your local Keysight office, or see
www.keysight.com/environment/product/ for more information.
Safety Symbols
Table 1 Safety Symbol
Table 2 Compliance and Environmental Information
Contents
1 Introduction
2 M8195A Software Installation
2.1 Pre-Requisites 13
2.2 Installation Process 14
2.3 Post Installation Steps 22
2.4 How to use the Instrument 23
3 AXle Chassis
3.1 ESM Front Panel Connector 25
4 M8195A Maintenance
4.1 ESD Protection 28
4.2 Power and Ventilation Requirements 29
Contents
4.3 Thermal Protection 29
4.4 Battery 29
4.5 Cleaning Recommendation 29
5 Characteristics
5.1 Performance Specification 31
5.2 Operating Environment 31
5.3 General 31
M8195A Getting Started Guide 7
Keysight M8195A – Arbitrary Waveform Generator
Introduction
The Keysight M8195A is a 65 GSa/s Arbitrary Waveform Generator with highest bandwidth and channel density. It offers up to 16 GSa waveform memory. The M8195A is ideally suited to address following key applications:
Coherent optical – a single M8195A module can generate 2 independent
I/Q baseband signals (dual polarization = 4 channels) at up to 32 Gbaud and beyond.
Multi-level / Multi-channel digital signals – generate NRZ, PAM4, PAM8,
DMT, etc. signals at up to 32 Gbaud. Embed/De-embed channels, add Jitter, ISI, noise and other distortions.
Physics, chemistry, and electronics research – generate any
mathematically defined arbitrary waveforms, ultra-short yet precise pulses and extremely wideband chirps.
Wideband RF/µW – generate extremely wideband RF signals with an
instantaneous bandwidth of DC to 20 GHz for aerospace/defense/communication applications.
Getting Started Guide
1 Introduction
Introduction
Features and Benefits
The M8195A is an arbitrary waveform generator with highest sample rate, bandwidth, and channel density:
Sample rate up to 65 GSa/s (on each channel) Analog bandwidth: 20 GHz Vertical resolution: 8 bits 1, 2, or 4 differential channels per 1-slot high AXIe module (number of
channels is software upgradable)
Built-in frequency and phase response calibration Amplitude up to 1 Vpp (single ended) (2 Vpp (differential)) VT
Rise,20%...80% TFall,20%...80%
:18 ps (typ.)
Ultra low intrinsic Random Jitter RJ
rms
< 200 fs
Form factor: 1-slot AXIe module controlled via external PC or embedded
AXIe system controller M9536A
10 M8195A Getting Started Guide