Keysight u1273a, keysight u1273ax Quick Start Manual

Page 1
Keysight U1273A/U1273AX Handheld Digital Multimeter
Quick Start Guide
Page 2
Page 3
U1273A/U1273AX Handheld Digital Multimeter
NOTE
Verify that you received the following items in the shipment of your multimeter:
One pair of 4 mm test probes
One K-type thermocouple lead kit
Four 1.5 V AAA alkaline batteries (for U1273A) or lithium
batteries (for U1273AX)
Printed copies of the Certificate of Calibration (CoC) and
the U1273A/U1273AX Quick Start Guide (this manual)
If any item is missing or damaged, keep the shipping materials and contact the nearest Keysight Sales Office.
The descriptions and instructions in this guide apply to the U1273A/U1273AX handheld digital multimeter.
All related documents and software are available for download at www.keysight.com/find/hhTechLib.
U1273A/U1273AX Quick Start Guide 1
Page 4
U1273A/U1273AX Handheld Digital Multimeter
NOTE
Install the Batteries
Install the Batteries
Your multimeter is powered by four 1.5 V AAA batteries (included with the shipment).
1 Turn the rotary switch to OFF and remove
the test leads from the terminals.
2 Lift the tilt stand and loosen the screws
with a suitable Phillips screwdriver.
3 Remove the battery cover and observe the
polarity markings.
4 Insert the batteries and replace the battery cover and screws.
Turn On the Multimeter
To power ON your multimeter, turn the rotary switch from the OFF position to any other position.
Your multimeter is capable of remote data logging. To use this feature, you will need an IR-USB cable (U1173A, purchased separately) and the Keysight GUI Data Logger Software (down­loadable from www.keysight.com/find/hhTechLib).
Auto Dim
By default, the multimeter’s Auto Dim function is enabled. The multimeter’s backlight will dim automatically after 90 seconds of inactivity. Press any button to cancel this effect and reset the Auto Dim timer.
You may change how the multimeter’s backlight behavior through the Setup menu. Refer to the User’s Guide for further instructions.
2 U1273A/U1273AX Quick Start Guide
Page 5
U1273A/U1273AX Handheld Digital Multimeter
Display screen
Keypad
Rotary switch
Input terminals
Test lead/probe holders
IR communication port
Battery cover
Tilt stand
(Lift tilt stand for access)
The Multimeter at a Glance
The Multimeter at a Glance
U1273A/U1273AX Quick Start Guide 3
Page 6
U1273A/U1273AX Handheld Digital Multimeter
NOTE
S
h
i
f
t
V
i
e
w
E
s
c
Z
LOW
Smart
Auto
Understanding the Rotary Switch
Understanding the Rotary Switch
Press to switch between the primary and shifted func- tions shown on the rotary switch.
Legend Description
Z
(low input impedance) AC/DC V for eliminating
LOW
ghost voltages
Off
AC V
AC V with Low Pass Filter
AC mV
AC mV with Low Pass Filter
DC V
AC V or AC+DC V
DC mV
AC mV or AC+DC mV
Resistance
Continuity or Smart (offset compensation)
Diode
Auto-diode
Capacitance
Temperature
DC mA (or A)
4 U1273A/U1273AX Quick Start Guide
AC mA (or A) or AC+DC mA (or A)
DC A
AC A or AC+DC A
Page 7
U1273A/U1273AX Handheld Digital Multimeter
S
c
a
l
e
N
u
l
l
P
e
a
k
M
a
x
M
i
n
A
u
t
o
T
r
i
g
H
o
l
d
Exit
Dual
Setup
H
z
%
m
s
L
o
g
A
u
t
o
R
a
n
g
e
S
h
i
f
t
V
i
e
w
E
s
c
Understanding the Keypad
Understanding the Keypad
Legend
Key response when pressed for:
Less than 1 second More than 1 second
Sets the Null/Relative mode.
Starts the MaxMin recording.
Freezes the present reading in the display.
Switches between avail­able dual-combination displays.
Sets the Scale mode for the specified ratio and unit display.
Starts and stops the Peak recording.
Automatically freezes the present reading once the reading is stable.
Exits the Hold, Null, MaxMin, Peak, fre­quency test, and dual display modes.
Increases the OLED brightness incremen­tally when LOW, MEDIUM, or HIGH set-
Enters and exits the mul­timeter’s Setup menu.
ting is selected.
U1273A/U1273AX Quick Start Guide 5
Switches between fre­quency, pulse width, and duty cycle measure­ments.
Sets a manual range and disables autoranging.
Switches between the primary and shifted functions.
Starts and stops the Data Logging.
Enables auto-ranging.
Enters and exits the Log Review menu.
Page 8
U1273A/U1273AX Handheld Digital Multimeter
WARNING
Z
LOW
Smart
Auto
or
Understanding the Input Terminals
Understanding the Input Terminals
Ensure that the terminal connections are correct for that particular measurement function before starting any measurement. To avoid damage to the device, do not exceed the input limit.
Rotary position Input terminals Overload protection
1000 Vrms
1000 Vrms for short
circuit <0.3 A
11 A/1000 V
fast-acting fuse
440 mA/1000 V fast-acting fuse
6 U1273A/U1273AX Quick Start Guide
Page 9
U1273A/U1273AX Handheld Digital Multimeter
DC
1
2
3
4
Performing Measurements and Tests
Performing Measurements and Tests
Voltage measurements
The figure below highlights the primary functions allowing voltage measurements in your multimeter.
Set up your multimeter as shown in the figure below to per­form voltage measurements. When measuring DC voltage from a mixed signal in DC measurement mode, ensure that the Filter (
) is enabled.
U1273A/U1273AX Quick Start Guide 7
Page 10
U1273A/U1273AX Handheld Digital Multimeter
CAUTIONCAUTION
Setup
H
z
%
m
s
L
o
g
Exit
Dual
Setup
H
z
%
m
s
L
o
g
Setup
S
h
i
f
t
V
i
e
w
E
s
c
Performing Measurements and Tests
1 Press for more than 1 second to enter the multimeter’s
setup menu.
2 Browse to Menu 6 > Filter, and press to edit the
value.
3 Press or to enable the Filter.
Refer to the table below for the respective firmware ver­sions.
Version 1.64 or older Version 1.95 or newer
on DC
4 Press to save your changes.
5 Press and hold until the multimeter restarts and returns
to normal operation. Turn the multimeter to DC Voltage mode to verify that the LPF symbol is turned on.
To avoid possible electric shock or personal injury, enable the Filter
() to verify the presence of hazardous DC
voltages. Displayed DC voltages can be influenced by high frequency AC components and must be filtered to assure an accurate reading.
LPF during AC measurements:
Press while performing AC voltage measurements to pass the measured signal through a low pass filter.
Passing the measured signal through a LPF help blocks unwanted voltages such as electronic noise.
Use the LPF function to improve measurement on compos­ite sine waves that are typically generated by inverters and variable frequency motor drives.
8 U1273A/U1273AX Quick Start Guide
Page 11
Z
Z
LOW
measurements:
LOW
U1273A/U1273AX Handheld Digital Multimeter
Performing Measurements and Tests
Rotate the rotary switch’s position to
to enable low impedance mea-
surements.
Use the Z
(low input impedance) function to remove
LOW
ghost or induced voltages from your measurement.
Z
can remove ghost voltages from your measurements
LOW
by dissipating the coupling voltage. Use Z
to reduce the
LOW
possibility of false readings in areas where the presence of ghost voltages are suspected.
U1273A/U1273AX Quick Start Guide 9
Page 12
U1273A/U1273AX Handheld Digital Multimeter
Smart
1
2
3
4
S
h
i
f
t
V
i
e
w
E
s
c
Exit
Dual
Performing Measurements and Tests
Resistance measurements
Set up your multimeter as shown in the figure below to per­form resistance measurements.
Smart measurements:
Use the Smart (offset compensation) function to measure
10 U1273A/U1273AX Quick Start Guide
resistors affected by DC offset or leakage current.
Smart  removes unexpected DC voltages within the instru- ment, at the input, or at the circuit being measured, which will add error to resistance measurements. Press to switch between the bias voltage (BiAS) display or leakage current (LEAk) display, calculated based on the bias voltage and corrected resistance value, on the secondary display.
While performing resistance mea­surements, press until BiAS is shown on the secondary display to enable the Smart function.
Page 13
U1273A/U1273AX Handheld Digital Multimeter
S
h
i
f
t
V
i
e
w
E
s
c
Exit
Dual
Smart
ON
(closed)
OFF
(open)
1
2
4
5
3
S
h
i
f
t
V
i
e
w
E
s
c
NOTE
Performing Measurements and Tests
Continuity tests
Set up your multimeter as shown in the figure below to per­form continuity tests. Press to switch to the continuity test function ( is shown on the display).
The beeper will sound as a continuity indication. Press to switch between normal open ( ) and normal close ( ) contacts.
• Normal open: Circuit is normally open, the beeper will sound when a short is detected.
• Normal close: Circuit is normally closed, the beeper will sound when an open is detected.
The continuity function detects intermittent shorts and opens lasting as short as 1 ms. A brief short or open causes the multi­meter to emit a short beep.
U1273A/U1273AX Quick Start Guide 11
Page 14
U1273A/U1273AX Handheld Digital Multimeter
1
2
3
4
S
h
i
f
t
V
i
e
w
E
s
c
Performing Measurements and Tests
Diode tests
Set up your multimeter as shown in the figure below to per­form diode tests.
Auto
Auto-diode tests:
Press to use the auto diode function.
The Auto-diode function tests both the forward bias and reverse bias directions of your diode simultaneously. The forward bias voltage is shown on the primary display and the reverse bias voltage is shown on the secondary display.
•GOOD is shown briefly on the secondary display along with a brief beep if the diode is found to be in good condition. If the diode is out of the thresholds, NGOOD is shown instead.
12 U1273A/U1273AX Quick Start Guide
Page 15
U1273A/U1273AX Handheld Digital Multimeter
1
2
3
4
NOTE
Performing Measurements and Tests
Capacitance measurements
Set up your multimeter as shown in the figure below to per­form capacitance measurements.
is shown on the bottom left of the display when the capaci­tor is charging, and is shown when the capacitor is dis­charging.
U1273A/U1273AX Quick Start Guide 13
Page 16
U1273A/U1273AX Handheld Digital Multimeter
S
h
i
f
t
V
i
e
w
E
s
c
WARNING
1
2
4
5
3
S
h
i
f
t
V
i
e
w
E
s
c
K-type thermocouple
Heat source
NOTE
Performing Measurements and Tests
Temperature measurements
Set up your multimeter as shown in the figure below to per­form temperature measurements. Press to switch to the temperature measurement function.
Do not connect the thermocouple to electrically live circuits. Doing so will potentially cause fire or electric shock.
The multimeter uses a type-K (default setting) temperature probe for measuring temperature.
14 U1273A/U1273AX Quick Start Guide
Page 17
U1273A/U1273AX Handheld Digital Multimeter
S
h
i
f
t
V
i
e
w
E
s
c
WARNING
AC
LOAD
1
2
3
4
NOTE
Performing Measurements and Tests
Current measurements
Set up your multimeter as shown in the figure below to per­form current measurements. Press to switch between AC, DC, AC+DC, or % scale current measurements. When mea­suring DC current from a mixed signal in DC measurement mode, ensure that the Filter (
Always use the proper function, range, and terminals for current measurements. Set the positive input terminal to the terminal for currents below 440 mA, and the
terminal for currents above 440 mA.
) is enabled.
For better accuracy when measuring low currents (up to A), turn the rotary switch to the position.
U1273A/U1273AX Quick Start Guide 15
Page 18
U1273A/U1273AX Handheld Digital Multimeter
Smart
Smart
To check Fuse 1 To check Fuse 2
Check the Fuse
Check the Fuse
Follow the instructions below for a quick check on the fuses (Fuse 1 and Fuse 2) of your multimeter.
Fuse
Part
number
1 2110-1400 440 mA/1000 V 102  OL
2 2110-1402 11 A/1000 V 0.05  OL
Displayed readings
Fuse rating
Fuse healthy Replace fuse
16 U1273A/U1273AX Quick Start Guide
Page 19
U1273A/U1273AX Handheld Digital Multimeter
NOTE
Check the Fuse
To c he ck Fu se 1: Ensure that the probe tip is touching the
top half metal contact inside the µA mA terminal.
To c he ck Fu se 2: Ensure that the probe tip is touching the
left half metal contact inside the A terminal.
The multimeter will sound an input warning alert if the probe tip is in contact with any other sides of the µA mA or A termi­nal other than the sides specified in the instructions above.
U1273A/U1273AX Quick Start Guide 17
Page 20
U1273A/U1273AX Handheld Digital Multimeter
Check the Fuse
18 U1273A/U1273AX Quick Start Guide
Page 21
Contacting Keysight
CAUTIONCAUTION
WARNING
CAT III 1000 V
CAT IV
600 V
To obtain service, warranty, or technical assistance, contact us at the fol­lowing phone numbers:
United States Call Center: 800-829-4444
Canada Call Center: 877-894-4414
China Call Center: 800-810-0189
Europe Call Center: 31-20-547-2111
Japan Call Center: (81) 426-56-7832
For other countries, contact your country’s Keysight support organization. A list of contact information for other countries is available on the Keysight Web site: www.keysight.com/find/assist
Safety Notices Safety and EMC Information
A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAU- TION notice until the indi­cated conditions are fully understood and met.
A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not pro­ceed beyond a WARNING notice until the indicated conditions are fully under­stood and met.
This meter is safety-certified in compliance with EN/IEC 61010-1:2001, ANSI/UL 61010-1:2004, and CAN/CSA-C22.2 No. 61010-1-04 for CAT III 1000 V/CAT IV 600 V pollution degree 2 environment. EMC is designed in compliance with IEC 61326-1:2005/EN 61326-1:2006. Use with standard or compatible test probes.
Safety Symbols
Earth (ground) terminal
Equipment protected throughout by double insula­tion or reinforced insulation
Caution, risk of electric shock
Caution, risk of danger (refer to the instrument manual for specific Warning or Caution information)
Category III 1000 V overvoltage protection
For further safety information details, refer to the
Keysight U1273A/U1273AX Handheld Digital Multimeter User’s Guide.
Category IV 600 V overvoltage protection
Page 22
Page 23
This information is subject to change without notice.
© Keysight Technologies 2012 – 2014
Edition 3, August 2014
*U1273-90004*
U1273-90004
www.keysight.com
Loading...