This EXA conguration guide will help you
determine which performance options,
measurement applications, accessories,
and services to include with your new EXA
or to add as upgrades to an existing EXA.
This step-by-step process will help you configure your new N9010A EXA X-Series signal analyzer as well as add millimeter-wave
capabilities. Tailor the per formance to meet your requirements. For detailed specifications, refer to the specification guide (N9010-
90025). For a summar y of specifications, refer to the data sheet (5989-6529EN).
Included in base product
Standard options and accessories come with the EXA base model at no additional charge and do not need to be ordered. They include:
– Spectrum analyzer measurement application
– Dual-core, high-performance processor, 8 GB RAM, removable solid-state drive
– Frequency reference
– Mechanical attenuator
– 10 MHz/25 MHz analysis bandwidth
– Enhanced phase noise
– Windows Embedded Standard 7
– Real-time link
– Benchtop configuration
– Mouse
– User guide
– Front-panel protective cover
– Power cord
– 3-year return-to-Keysight warranty
Step 1. Select maximum frequency range (required option)
DescriptionOption numberAdditional information
Frequency range, 10 Hz to 3.6 GHzN9010A-503
Frequency range, 10 Hz to 7 GHzN9010A-507
Frequency range, 10 Hz to 13.6 GHzN9010A-513
Frequency range, 10 Hz to 26.5 GHzN9010A-526
Frequency range, 10 Hz to 32 GHzN9010A-532
Frequency range, 10 Hz to 44 GHzN9010A-544
Step 2. Add a preamplier
DescriptionOption numberAdditional information
Preampliers improve the noise oor for low-level signal detection
Preamplier, 100 kHz to 3.6 GHzN9010A-P03Compatible with frequency range options N9010A-503, N9010A-507, N9010A-513,
N9010A-526, N9010A-532, and N9010A-544
Preamplier, 100 kHz to 7 GHz N9010A-P07Compatible with frequency range options N9010A-507, N9010A-513, N9010A-526,
N9010A-532, and N9010A-544
Preamplier, 100 kHz to 13.6 GHzN9010A-P13Compatible with frequency range options N9010A-513, N9010A-526
Preamplier, 100 kHz to 26.5 GHzN9010A-P26Compatible with frequency range option N9010A-526
Preamplier, 100 kHz to 32 GHzN9010A-P32Compatible with frequency range option N9010A-532
Preamplier, 100 kHz to 44 GHzN9010A-P44Compatible with frequency range option N9010A-544
Step 3. Choose frequency reference
DescriptionOption numberAdditional information
Frequency referenceStandardAging rate: ± 1 x 10–6/year
Precision frequency reference
10 MHz
N9010A-PFR Reduces frequency drift for more accurate measurements; aging rate: ± 1 x 10–7/year
Step 4. Choose an attenuator
DescriptionOption numberAdditional information
Mechanical attenuatorStandard10 dB steps, 0 to 60 dB
Fine step attenuatorN9010A-FSAAllows 2 dB steps for the full 60 dB range of the mechanical attenuator
Electronic attenuator up to 3.6 GHzN9010A-EA3In addition to the mechanical attenuator; 1 dB steps, 0 to 24 dB
Useful for most cellular communications, wireless connectivity, and audio/video broadcasting
measurement applications
40 MHz analysis bandwidth N9010A-B40 Extends the analysis (demod) bandwidth to 40 MHz (Option MPB required for measurements
at frequency > 3.6 GHz); also enables fast sweep capability licensed as N9010A-FS1 and
N9010A-FS2
Microwave preselector bypass N9010A-MPBRequired for wide analysis bandwidth measurements with Option B40 at frequency > 3.6 GHz;
also enables fast sweep capability licensed as N9010A-FS1 and N9010A-FS2
Step 6. Choose performance options
DescriptionOption numberAdditional information
Enhanced phase noiseStandard
Digital processor with 2 GB capture
N9010A-DP2Comes standard with Option B40; also enables fast sweep capability licensed as N9010A-FS1
memory
1
Licensed as N9010A-EP5
and N9010A-FS2
Fast powerN9010A-FP2Accelerates the power measurements such as ACPR; requires Option B40
Noise oor extensionN9010A-NFEImproves analyzer’s DANL performance (instrument alignment based processes); licensed as
N9010A-NF2
Step 7. Add optional features
DescriptionOption numberAdditional information
Enhanced display packageN9010A-EDPIncludes spectrogram, trace zoom, and zone span
Basic precompliance EMIN9010A-EMCPerform basic EMI precompliance measurements with CISPR 16-1-1 detectors and bandwidths;
tune and listen, and measure at marker are also available
External source controlN9010A-ESCExternal source control for Keysight EXG, MXG, and PSG signal generators for scalar stimu-
lus-response measurements; supports external mixing; includes 3 BNC cables and 1 crossover
LAN cable
External mixingN9010A-EXMProvides external mixing with Keysight and third-party mixers; single port 2 for LO out and IF in
(SMA female); compatible with Options 532 and 544 only
Time domain scanN9010A-TDSImproves scan speed for EMC pre-compliance tests; requires N6141A EMC pre-compliance
measurement application and Option DP2, or B40
Step 8. Select operating system
DescriptionOption numberAdditional information
Windows Embedded Standard 7StandardLicensed as N9010A-W7X
N9010A-SSDProvides a fully-imaged, removable solid-state drive in addition to the one installed in the
instrument
N9010A-SF1Prevents the launching of Windows programs from the instrument application
program
Security features, prohibit saving
results
1. All RF and microwave instruments with serial number prefix break of MY/SG/US5648 are installed with the N9010A-EP5 for the enhanced phase noise
performance. The N9010A-EP5 is not upgradable.
2. When used with the Keysight 11970 Series ex ternal mixers, an external diplexer is required. Recommended diplexer can be purchased from Keysight as
N9029AE13, or from OML Inc. as DPL.313B.
N9010A-SF2Prevents the saving/recall of measurement results or user congurations to/from instrument’s
Second IF outputN9010A-CR3 Wideband IF out; output center frequency depends on IF BW option (25/40); output on Aux IF
connector at rear panel
Arbitrary IF outputN9010A-CRPIF out 10 to 75 MHz (in 500 kHz steps); output on Aux IF connector at rear panel
Y-axis screen video outputN9010A-YASScreen video (0-1 volt open circuit) on rear panel analog out
Real-time linkStandardThe LVDS connector allows EXA to connect to X-COM data recorder or data streaming (up
to 40 MHz BW), and to the N5106A PXB baseband generator and channel emulator; requires
Option B40 or DP2; licensed as N9010A-RTL
Step 11. Choose measurement application or software and license type
Note: The last two letters of the ordering numbers indicate the license type—FP stands for fixed perpetual, TP for transportable perpetual; it is
recommended that you configure each application with the same license type; visit www.keysight.com/find/X-Series_transportable for more
information about transportable licenses
N9073A-2FPN9073A-2TPAdds HSPA measurements; requires 1FP/1TP
N9073A-3FPN9073A-3TPAdds HSPA+ measurements; requires 1FP/1TP, 2FP/2TP
N9073A-XFPN9073A-XTPAdds single acquisition combined measurement, a SCPI-command-based
measurement optimized for high-volume, high-throughput manufacturing;
requires 1FP/1TP; not compatible with Options DP2, B40, or MPB; not compatible with Options 532 or 544
GSM/EDGE/EVO
N9071A-2FPN9071A-2TPStandard-based, one-button GSM/EDGE measurements
N9071A-3FPN9071A-3TPAdds EDGE Evolution and VAMOS measurements; requires 2FP/2TP
N9071A-XFPN9071A-XTPAdds single acquisition combined measurement, a SCPI-command-based
measurement optimized for high-volume, high-throughput manufacturing;
requires 2FP/2TP; not compatible with Options DP2, B40, or MPB; not compatible with Options 532 or 544
N9051B-3FPN90 51B-3 T PAdds phase and frequency measurements; requires 2FP/2TP
N9 0 51B-4 FPN9 051B- 4TPAdds extended analysis and statistics; requires 2FP/2TP
N9 0 51B-5FPN9 051B-5TPExtends capture depth to 50 MSa; requires 2FP/2TP
SCPI command
N9062A-2FPNot availableAdds capability to emulate the R&S FSP/FSU/FSE spectrum analyzers
language
compatibility
Remote language
compatibility
89600 VSA softwareNot available89 601B
N9061A-1FPNot availableAdds capability to emulate the 8566/68 spectrum analyzers
N9061A-2FPNot availableAdds capability to emulate the 856xE/EC spectrum analyzers
Industry-leading measurement software for evaluating and troubleshooting
(transportable license
is standard)
signals in R&D; PC-based software supporting more than 40 measurement
platforms, plus more than 75 signal standards and modulation types including
Mouse, USB interfaceStandardEvery EX A is shipped with a USB mouse, which enhances the usability of the
Windows operating system
User guideStandard – US – English localization
– All user documentation is included in the EXA’s embedded, context-sensi-
tive help system and on a DVD that is shipped with the instrument
– User documentation can be downloaded from:
www.keysight.com/find/exa_manuals
Front-panel protective coverStandard
Power cordStandardDependent upon region of use
Adapter, 2.4 mm (F) to 2.9 mm (F)StandardShip standard only for Option 532
Adapter, 2.4 mm (F) to 2.4 mm (F)StandardShip standard only for Option 544
Rack mount N9010A-1CMAdds rack mount anges to the EX A
Front handles N9010A-1CNAdds front handles to the EX A
Rack mount with handlesN9010A-1CPAdds rack mount anges and handles to the EXA
Rack slideN9010A-1CR Adds a non-tilting rack slide to the EXA
Accessory pouchN9010A-BAGEasily store and carry the N9010A-KB2 keyboard and USB mouse in this
attachable pouch
USB DVD-ROM/CD-R/RW driveN9010A-DVREnhances the usability of the Windows operating system
Hard transit caseN9010A-HTCUltra-durable, wheeled carrying case offers maximum protection and portability
US 65-key USB keyboardN9010A-KB2Compact design ts in N9010A-BAG accessory pouch for convenient storage
Keyboard, USB interfaceN9010A-KYBEnhances the usability of the Windows operating system
(Note: Does not t N9010A-BAG accessory pouch)
Minimum loss pad, 50 to 75 Ω (type-N to BNC)N9010A-MLP– 50 Ω type-N male to 75 Ω BNC female adapter
– Frequency range: 9 MHz to 2 GHz– Input/output return loss: 20 and 11 dB
– Insertion loss: 5.7 dB
V-Band waveguide harmonic mixers, 50 to 75 GHzM1970V-001Requires Option EXM; USB mixer with smart features
Extended V-band waveguide harmonic mixers,
M1970V-002Requires Option EXM; USB mixer with smart features
50 to 80 GHz
E-Band waveguide harmonic mixers, 60 to 90 GHzM1970ERequires Option EXM; USB mixer with smart features
W-Band waveguide harmonic mixers, 75 to 110 GHzM1970WRequires Option EXM; USB mixer with smart features
E-band waveguide harmonic mixer, 60 to 90 GHzM1971E- 0 01Requires Option EXM; USB mixer with smart features and 3 signal paths
Extended E-band waveguide harmonic mixer,
M1971E- 0 0 3Requires Option EXM; USB mixer with smart features and 3 signal paths
55 to 90 GHz
V-band waveguide harmonic mixer, 55 to 75 GHzM1971VRequires Option EXM; USB mixer with smart features and 3 signal paths
W-band waveguide harmonic mixer, 75 to 110 GHzM1971WRequires Option EXM; USB mixer with smart features and 3 signal paths
26 - 40 GHz waveguide harmonic mixer11970ARequires Option EXM and N9029AE13 diplexer
33 - 50 GHz waveguide harmonic mixer11970QRequires Option EXM and N9029AE13 diplexer
40 - 60 GHz waveguide harmonic mixer11970URequires Option EXM and N9029AE13 diplexer
50 - 75 GHz waveguide harmonic mixer11970VRequires Option EXM and N9029AE13 diplexer
75 - 110 GHz waveguide harmonic mixer11970WRequires Option EXM and N9029AE13 diplexer
90 to 140 GHz OML harmonic mixerN9029AE08Ordering convenience; requires Option EXM
110 to 170 GHz OML harmonic mixerN9029AE06Ordering convenience; requires Option EXM
140 to 220 GHz OML harmonic mixerN9029AE05Ordering convenience; requires Option EXM
220 to 325 GHz OML harmonic mixerN9029AE03Ordering convenience; requires Option EXM
LO/IF DiplexerN9029AE13Ordering convenience; needed for 11970 Series external mixers
For more information on accessories go to: www.keysight.com/find/accessories
50 to 75 GHz frequency extension moduleN9029AV15VDI signal analyzer frequency extension module; requires Option EXM
60 to 90 GHz frequency extension moduleN9029AV12VDI signal analyzer frequency extension module; requires Option EXM
75 to 110 GHz frequency extension moduleN9029AV10VDI signal analyzer frequency extension module; requires Option EXM
90 to 140 GHz frequency extension moduleN9029AV08VDI signal analyzer frequency extension module; requires Option EXM
110 to 170 GHz frequency extension moduleN9029AV06VDI signal analyzer frequency extension module; requires Option EXM
140 to 220 GHz frequency extension moduleN9029AV05VDI signal analyzer frequency extension module; requires Option EXM
220 to 330 GHz frequency extension moduleN9029AV03VDI signal analyzer frequency extension module; requires Option EXM
325 to 500 GHz frequency extension moduleN9029AV02VDI signal analyzer frequency extension module; requires Option EXM
550 to 750 GHz frequency extension moduleN9029AV1BVDI signal analyzer frequency extension module; requires Option EXM
750 to 1100 GHz frequency extension moduleN9029AV01VDI signal analyzer frequency extension module; requires Option EXM
Power supply for VDI moduleN5 2 6 2 V DI-175Required for the N9029AVxx VDI module
USB external preamplier, 10 MHz to 4 GHzU7227ARequires rmware A.14.00 or higher
USB external preamplier, 0.1 to 26.5 GHzU7227CRequires rmware A.14.00 or higher
USB external preamplier, 2 to 50 GHzU7227FRequires rmware A.14.00 or higher
For more information on accessories go to: www.keysight.com/find/accessories
Getting started guide EX A KoreanN9010A-AB1
Getting started guide EX A ChineseN9010A-AB2
Getting started guide EX A GermanN9010A-ABD
Getting started guide EX A FrenchN9010A-ABF
Getting started guide EX A JapaneseN9010A-ABJ
Getting started guide EX A RussianN9010A-AKT
Step 15. Choose warranty length
DescriptionOption numberAdditional information
Return-to-Keysight warranty, 3 yearsStandard3-year warranty is included at no additional charge
Warranty Assurance Plan, Return-to-Keysight,
R-51B-001-5C
5 years
Step 16. Add calibration, technical training, support, and upgrade services
DescriptionOption numberAdditional information
Commercial calibration certicate with test dataN9010A-UK6Calibration certicate only available at time of instrument purchase; only
N9010A-AMGProvides ISO 17025A accredited calibration from factory
ANSI Z 5 4 0-1-19 94 Calib r a t ionN9010A-A6JProvides ANSI Z540 compliant calibration from factory
Calibration Assurance Plan, Return-to-Keysight,
3 years
R-50C-011-3 Keysight tests your instrument against its original specications and
automatically makes adjustments if outside of specied parameters; pre- and
post-adjustment measurement data reports also provided
Service: remote scheduled
productivity assistance
PS-S10-100 Hourly phone-in technical support service designed to help you understand
and operate your equipment through convenient phone and Web access
Service: 1-day start-up assistance PS-S20-01 Training on how to operate your instrument effectively (recommended)
Service: productivity assistance PS-S20 -100 Daily instrument and application consulting using your equipment and device
under test
Service: custom engineering service PS-X10-100 Application-specic technical assistance
Other calibration options may be available; for more information on calibration go to: www.keysight.com/find/calibration
For more information on training and application support services go to: www.keysight.com/find/training
Fast license-key upgrades for performance options that do not require additional
hardware:
1. Place an order for the upgrade with Keysight and request to receive the option
upgrade entitlement certificate and a one-time software upgrade license through
email
2. Redeem the certificate through the Web by following the instructions on the
certificate
3. Install the license file and latest software in the EXA
4. Begin using the new capability
Installation and testing information is available at: www.keysight.com/find/exa_upgrades
Upgrades for analysis bandwidth depend on the vintage of the instrument and the
options already installed. More than one option may be required to achieve desired wider
analysis bandwidth. Use our web-based calculator to find the upgrade options you may
need: www.keysight.com/find/BW-selector
1, 2
You can upgrade!
Options can be
added after your
initial purchase.
All of our X-Series
application options
are license-key upgradeable.
DescriptionUpgrade
number
Requirements
(EXA must already
Additional information
include the following)
Increase frequency from 3.6 to 7 GHz,N9010AK-F01503
Increase frequency from 3.6 to 13.6 GHzN9010AK-F02503
Increase frequency from 3.6 to 26.5 GHzN9010AK-F03503
Increase frequency from 3.6 to 32 GHzN9010AK-F04503Requires serial number ≥ MY/SG/US52180000
Increase frequency from 3.6 to 44 GHzN9010AK-F05503Requires serial number ≥ MY/SG/US52180000
Increase frequency from 7 to 13.6 GHzN9010AK-F06507
Increase frequency from 7 to 26.5 GHzN9010AK-F07507
Increase frequency from 7 to 32 GHzN9010AK-F08507Requires serial number ≥ MY/SG/US52180000
Increase frequency from 7 to 44 GHzN9010AK-F09507Requires serial number ≥ MY/SG/US52180000
Increase frequency from 13.6 to 26.5 GHzN9010AK-F10513
Increase frequency from 13.6 to 32 GHzN9010AK-F11513Requires serial number ≥ MY/SG/US52180000
Increase frequency from 13.6 to 44 GHzN9010AK-F12513Requires serial number ≥ MY/SG/US52180000
Increase frequency from 26.5 to 32 GHzN9010AK-F13526Requires serial number ≥ MY/SG/US52180000
Increase frequency from 26.5 to 44 GHzN9010AK-F14526Requires serial number ≥ MY/SG/US52180000
Increase frequency from 32 to 44 GHzN9010AK-F15532Includes 44 GHz preamp
Increase analysis bandwidth from 10 to 25 MHzN9010AK-B25 3None
Increase analysis bandwidth from 10 to 40 MHzN9010AK-B40DP2 or MPB
Increase analysis bandwidth from 25 to 40 MHzN9010AK-BU1B25 and DP2 or MPB
Increase analysis bandwidth to 40 MHz. Includes
microwave preselector bypass. Options 507, 513,
and 526 only.
N9010AK-HL4507, 513, or 526
Serial prex < US/SG/MY5648
N9010AK-HLA507, 513, or 526
Includes hardware and license key; also adds
microwave preselector bypass; not compatible
with Option 503, 532 or 544
Serial prex ≥ US/SG/MY5648
Increase analysis bandwidth to 40 MHz. Includes
microwave preselector bypass. Options 532 and
544 only.
N9010AK-HL7532 or 544
Serial prex < US/SG/MY5648
N9010AK-HLF532 or 544
Includes hardware and license key; also adds
microwave preselector bypass; not compatible
with Options 503, 507, 513, or 526
Serial prex ≥ US/SG/MY5648
Increase analysis bandwidth to 40 MHz,
Option 503 only.
N9010AK-HL8503
Serial prex < US/SG/MY5648
Includes hardware and license key; only
compatible with Option 503
N9010AK-HL9503
Serial prex ≥ US/SG/MY5648
1. At the time of manufacture, the hardware related to many of these options was fully adjusted and the option performance was verified to be within its
warranted specifications. Within two years of the initial calibration date of the analyzer, this option is fully calibrated with no further adjustment or
verification testing.
2. If this analyzer has been adjusted as part of a repair or calibration during its first two years, or if the analyzer is more than two years old, additional
adjustment and performance verif ication tests are required to ensure that some newly installed options are functioning properly. However, the completion
of these tests does not guarantee that the analyzer meets all warranted specifications.
3. This upgrade option is for instruments ordered before May 1, 2011.
Add preamplier, 3.6 GHzN9010AK-P03None
Add preamplier, 7 GHzN9010AK-P 07507, 513, 526, 533, or 544 Not compatible with Option 503
Add preamplier, 13.6 GHzN9010A K-P13513 or 526Not compatible with Option 503, 507, 532, or 544
Add preamplier, 26.5 GHzN9010AK-P26526Not compatible with Option 503, 507, 513, 532, or 544
Add preamplier, 32 GHzN9010AK-P32532
Add preamplier, 44 GHz N9010AK-P44544
Upgrade to the precision frequency referenceN9010A K-PFRNone
Add basic EMI precompliance featuresN9010AK-EMCNone
Add external source controlN9010AK-ESCNoneAdds feature to control the Keysight EXG, MXG, and
PSG signal generators; supports external mixing;
includes 3 BNC cables and 1 cross-over LAN cable for
scalar stimulus/response measurements
Add external mixingN9010AK-EXM532 or 544Includes additional hardware
Add second IF outputN9010AK-CR3B40, DP2 or MPB, or
CRP, 532, or 544
Add arbitrary IF output N9010AK-CRPFront End Controller with
Press System > Show > Hardware to check HW ID
HW ID of 41 or 75
Add second IF output and arbitrary IF outputN9010AK-HL3NoneIncludes hardware and license key
Add fast powerN9010AK-FP2B40For fast power measurements such as ACPR
Add noise oor extensionN9 010AK-NFENoneInstrument alignment based; licensed as N9010A-NF2
Add security features, exclude launch programN9010AK-SF1NonePrevents the launching of Windows programs from the
instrument application
Add security features, prohibit saving resultsN9010AK-SF2NonePrevents the saving/recall of measurement results or
user congurations to/from instrument’s data storage
Add time domain scan capabilityN9020AK-TDSN6141A and DP2, or B40For EMC pre=compliance tests only
Add Y-axis screen video outputN9010AK-YASNone
Upgrade to multi-touch user interface
Multi-touch user interfaceN9010AK-MTUPC6 or PC7Not all applications supported by N9010A with
standard user interface (UI) are supported with
multi-touch UI
Multi-touch user interface with processorN9010AK-MTPNoneUpgrade to dual-core high-performance processor
(PC7). Not all applications supported by N9010A
with standard user interface (UI) are supported with
multi-touch UI
Add enhanced display packageN9010AK-EDPNone
Upgrade operating system to Windows Embedded Standard 7
From 32-bit processorN9094AK-W7X1
N9094AK-PC6
PC1, PC2, or PC3Upgrade the existing 32-bit processor with Windows
1
XP to a quad-core 64-bit performance processor,
16 GB RAM, with removable solid-state drive and
Windows 7
From 64-bit processorN9094AK-W7X1
N9094AK-SSD
PC4 or PC5For existing 64-bit processors provides Windows 7
NoneFor Windows 7 operating system provices faster
1
processor for speed enhancement
1. At the time of manufacture, the hardware related to many of these options was fully adjusted and the option performance was verified to be within its
warranted specifications. Within two years of the initial calibration date of the analyzer, this option is fully calibrated with no further adjustment or
verification testing.
2. If this analyzer has been adjusted as part of a repair or calibration during its first two years, or if the analyzer is more than two years old, additional
adjustment and performance verif ication tests are required to ensure that some newly installed options are functioning properly. However, the completion
of these tests does not guarantee that the analyzer meets all warranted specifications.
From PC6 or PC7 processorN9010AK-MTUPC6 or PC7Allows signal analyzer to run multi-touch applications
From other processor N9010AK-MTPNoneAllows signal analyzer to run multi-touch applications
Portable congurationN9010AK-PRCNoneNot compatible with Options 1CM, 1CP, 1CN, 1CR
Front panel cover, additionalN9010AK-CVRNone
USB DVD-ROM/CD-R/RW driveN9010AK-DVRNone
Electronic attenuator, 3.6 GHzN9010AK-E A3None
Fine step attenuatorN9010AK-FSANone
Hard transit caseN9010AK-HTCNone
Keyboard, USB interfaceN9010AK-K YBNoneEnhances the usability of the Windows Professional
US 65-key USB keyboardN9010AK-KB2NoneCompact design ts in N9010A-BAG accessory pouch
Accessory pouchN9010AK-BAGNoneEasily store and carry the N9010AK-KB2 keyboard and
Minimum loss pad, 50 to 75 Ω (type-N to BNC)N9010AK-MLPNone
Mouse, USB interfaceN9010AK-MSENone
Rack mount kitN9010 A K-1CMNoneNot compatible with Options PRC, 1CP, 1CN
Front handle kitN9010AK-1CNNoneNot compatible with Options PRC, 1CP, 1CM
Rack mount and handle kitN 9 010 A K-1CPNoneNot compatible with Options PRC, 1CM, 1CN
Rack slide kitN 9 0 10AK-1C RNoneNot compatible with Options PRC
Getting started guide EX A KoreanN9010AK-AB1None
Getting started guide EX A ChineseN9010AK-AB2None
Getting started guide EX A GermanN9010AK-ABDNone
Getting started guide EX A FrenchN9010AK-ABFNone
Getting started guide EX A JapaneseN9010AK-ABJNone
Getting started guide EX A RussianN9010AK-AKTNone
PC4 or PC5For Windows 7 operating system provides additional
1
Additional information
removable solid-state drive
and upgrades to a dual-core 64-bit performance
processor, 8 GB RAM
operation system (Note: Does not t N9010A-BAG
accessory pouch)
for convenient storage
USB mouse in this attachable pouch
1. Must be ordered under N9010AK.
Related Literature
Keysight N9010A EXA signal analyzers
Publication titlePublication number
EXA X-Series Signal Analyzer N9010A, Brochure5989-6527EN
N9010A EXA X-Series Signal Analyzer, Data Sheet5989-6529EN
X-Series Measurement Applications, Brochure5989-8019EN
Our unique combination of hardware, software, support, and people can help
you reach your next breakthrough. We are unlocking the future of technology.
From Hewlett-Packard to Agilent to Keysight
myKeysight
www.keysight.com/find/mykeysight
A personalized view into the information most relevant to you.
Keysight Services
www.keysight.com/find/service
Our deep offering in design, test, and measurement services deploys an
industry-leading array of people, processes, and tools. The result? We help
you implement new technologies and engineer improved processes that
lower costs.
Keysight’s committed to superior product quality and lower total cost
of ownership. Keysight is the only test and measurement company with
three-year warranty standard on all instruments, worldwide. And, we provide
a one-year warranty on many accessories, calibration devices, systems and
custom products.
Up to ten years of protection and no budgetary surprises to ensure your
instruments are operating to specification, so you can rely on accurate
measurements.
For more information on Keysight
Technologies’ products, applications or
services, please contact your local Keysight
office. The complete list is available at: