Ordering Guide
The following steps will guide you through configuring your Keysight Technologies’ E5063A.
Description Additional information
Installation guide Contains the information necessary to start up with the E5063A.
CD ROM IO libraries
Power Cable
Calibration of Certification
Step 1. Choose frequency option (must choose one of the eight frequency options.)
Description Option no.
Network Analyzer 100 kHz to 500 MHz, S-parameter test set, 50 Ω system impedance E5063A-205
Network Analyzer 100 kHz to 1.5 GHz, S-parameter test set, 50 Ω system impedance E5 0 63A-215
Network Analyzer 100 kHz to 3 GHz, S-parameter test set, 50 Ω system impedance E5063A-235
Network Analyzer 100 kHz to 4.5 GHz, S-parameter test set, 50 Ω system impedance E5063A-245
Network Analyzer 100 kHz to 6.5 GHz, S-parameter test set, 50 Ω system impedance E5063A-265
Network Analyzer 100 kHz to 8.5 GHz, S-parameter test set, 50 Ω system impedance E5063A-285
Network Analyzer 100 kHz to 14 GHz, S-parameter test set, 50 Ω system impedance E5063A-2D5
Network Analyzer 100 kHz to 18 GHz, S-parameter test set, 50 Ω system impedance E5063A-2H5
Step 2. Choose software option (If not required, go to step 4.)
Description Option no. Requires Not compatible Additional information
Time Domain/Test wizard E5063A-011 None None
Time Domain E5063A-010 None E5063A-011 Adds time domain transform and gating capabilities
Wireless power transfer analysis
1. E5063A-011 is a superset of E5063A-010. E5063A-011 includes the capabilit y of E5063A-010.
E5063A-006 None None This option is required for wireless power transfer efficiency test of
1
This option is required for time domain analysis or PCB measurements
wireless power transfer modules
Step 3. Choose hardware option
Description Option no. Requires Not compatible Additional information
Add GPIB interface E5 0 63A-721 None E5063A-722 Must choose either Option 721 or 722
Without GPIB interface E5063A-722 None E50 63A-721 Must choose either Option 721 or 722
Add handler I/O interface E5063A-731 None E5 0 63A-732 Must choose either Option 731 or 732
Without handler I/O interface E5063A-7 32 None E5 0 6 3A-731 Must choose either Option 731 or 732
Step 4. Choose storage drive option (mandatory option)
Description Option no. Requires Not compatible Additional information
Standard storage drive E5063A-019 None None Option 019 is the only storage drive option for the E5063A.
Must choose this option
Page 3
03 | Keysight | E5063A ENA Series Network Analyzer - Configuration Guide
Step 5. Add accessory option (If not required, go to step 6.)
Description Option no. Requires Not compatible Additional information
Keyboard E5063A-810 None None USB Keyboard for simplifying word inputs.
Mouse E5063A-820 None None USB Mouse for simplifying measurement operation.
Rackmount Kit E5063A-1CM None None Not installable simultaneously with E5063A -1CP.
Front Handle Kit E5063A-1CN None None Not installable simultaneously with E5063A -1CP.
Handle/Rack Mount Kit E5063A-1CP None None Not installable simultaneously with E5063A -1CM or 1CN.
Step 6. Add calibration certificate (If not required, go to step 7.)
Description Option no. Additional information
ISO 17025 Compliant Calibration E5063A-1A7 ISO 17025 compliant calibration
ANSI Z540 compliant calibration E5063A-A6J ANSI Z540 compliant calibration
Step 7. Choose warranty plan
3 year return-to-keysight warranty and service is standard. The extended warranty option is available. Contact your local Keysight office or visit our web site for more information.
Step 8. Add related products
Description Option no. Requires Not compatible Additional information
USB Coaxial Switch, DC to 18 GHz, SPDT
USB Coaxial Switch, DC to 8 GHz Dual SP6T
USB Coaxial Switch, DC to 26.5 GHz Dual SP6T
1. The U1810B’s switching can be controlled with the graphical user interface of the option 011 Test Wizard, or with the E5063A’s SCPI command. (This command can be used even without the Option 011.)
U1810B None None The number of test ports can be expanded up to four by connecting this SPDT
switch to the E5063A’s port-1 and 2.
– For connecting both single-ended and dif ferential probes simultaneously
in the PCB measurements with the option E5063A-011.
– For testing multiple DUTs with one E5063A.
U1816A None None The number of test ports can be expanded up to 12 by connecting this SP6T
switch to the E5063A’s ports, which can provides a lower cost solution for multi-DUT (antenna) measurements
U1816C None None The number of test ports can be expanded up to 12 by connecting this SP6T
switch to the E5063A’s ports, which can provides a lower cost solution for multi-DUT (antenna) measurements
Page 4
04 | Keysight | E5063A ENA Series Network Analyzer - Configuration Guide
Frequency Upgrades
Upgrade kit option no. Description From To Customer installable
E5063AU-210 Upgrade from 500 MHz to 1.5 GHz E5063A-205 E5063A-215 No
E5063AU-230 Upgrade from 500 MHz to 3 GHz E5063A-205 E5063A-235 No E5063AU-240 Upgrade from 500 MHz to 4.5 GHz E5063A-205 E5063A-245 No E5063AU-260 Upgrade from 500 MHz to 6.5 GHz E5063A-205 E5063A-265 No E5063AU-280 Upgrade from 500 MHz to 8.5 GHz E5063A-205 E5063A-285 No E5063AU-2D0 Upgrade from 500 MHz to 14 GHz E5063A-205 E5063A-2D5 No E5063AU-2H0 Upgrade from 500 MHz to 18 GHz E5063A-205 E5063A-2H5 No E5063AU-231 Upgrade from 1.5 GHz to 3 GHz E50 63A-215 E5063A-235 No E5063AU-241 Upgrade from 1.5 GHz to 4.5 GHz E5063A-215 E5063A-245 No E5063AU-261 Upgrade from 1.5 GHz to 6.5 GHz E5 0 6 3A-215 E5063A-265 No E5063AU-281 Upgrade from 1.5 GHz to 8.5 GHz E5063A-215 E5063A-285 No E5063AU-2D1 Upgrade from 1.5 GHz to 14 GHz E5063A-215 E5063A-2D5 No E5063AU-2H1 Upgrade from 1.5 GHz to 18 GHz E5063A-215 E5063A-2H5 No E5063AU-243 Upgrade from 3 GHz to 4.5 GHz E5063A-235 E5063A-245 No E5063AU-263 Upgrade from 3 GHz to 6.5 GHz E5063A-235 E5063A-265 No E5063AU-283 Upgrade from 3 GHz to 8.5 GHz E5063A-235 E5063A-285 No E5063AU-2D3 Upgrade from 3 GHz to 14 GHz E5063A-235 E5063A-2D5 No E5063AU-2H3 Upgrade from 3 GHz to 18 GHz E5063A-235 E5063A-2H5 No E5063AU-265 Upgrade from 4.5 GHz to 6.5 GHz E5063A-245 E5063A-265 No E5063AU-285 Upgrade from 4.5 GHz to 8.5 GHz E5063A-245 E5063A-285 No E5063AU-2D5 Upgrade from 4.5 GHz to 14 GHz E50 63A-245 E5063A-2D5 No E5063AU-2H5 Upgrade from 4.5 GHz to 18 GHz E5063A-245 E5063A-2H5 No E5063AU-286 Upgrade from 6.5 GHz to 8.5 GHz E5063A-265 E5063A-285 No E5063AU-2D6 Upgrade from 6.5 GHz to 14 GHz E5063A-265 E5063A-2D5 No E5063AU-2H7 Upgrade from 6.5 GHz to 18 GHz E5063A-265 E5063A-2H5 No E5063AU-2D8 Upgrade from 8.5 GHz to 14 GHz E5063A-285 E5063A-2D5 No E5063AU-2H6 Upgrade from 8.5 GHz to 18 GHz E5063A-285 E5063A-2H5 No E5063AU-2HD Upgrade from 14 GHz to 18 GHz E5063A-2D5 E5063A-2H5 No
Hardware Upgrades
Upgrade model no.
E5063AU-721 Add GPIB interface E5063A-721 No None
E5 0 63AU-731 Add handler I/O interface E50 6 3A-731 No None
Description Option no. Customer
Software Upgrades
Upgrade model no.
E5063AU-011 Time Domain/Test wizard E5063A-011 Yes None This option is required for time domain
E5063AU-010 Time Domain E5063A-010 Yes None Adds time domain transform and
E5063AU-006 Wireless power transfer
Description Option no. Customer
E5063A-006 Yes None This option is required for wireless
analysis
installable
installable
Requires (Instrument must already include the following)
Requires (Instrument must already include the following)
Additional information
analysis or PCB measurements
gating capabilities
power transfer efficiency test of wireless power transfer modules
Page 5
05 | Keysight | E5063A ENA Series Network Analyzer - Configuration Guide
Test Accessories and Calibration Kits
Test accessories and calibration kits that can be used with the E5063A are listed in this section. A complete line of test accessories and calibration kits can be found at the following websites:
http://www.keysight.com/find/na_accessories http://www.keysight.com/find/accessories
Test accessories
Test accessories such as test port cable are necessary for a complete measurement system using the E5063A. Order test accessories in accordance with the desired measurement system.
Category Product Number Description
Cables N6314A 50 Ω type-N (m) to type-N (m) cable, DC to 12.4 GHz, 61 cm (24 in)
N6 315A 50 Ω type-N (m) to type-N (f) cable, DC to 12.4 GHz, 61 cm (24 in)
11500E 3.5 mm (m) to 3.5 mm (m) cable, 61 cm (24 in)
11500F 3.5 mm (m) to 3.5 mm (m) cable, 152 cm (60 in)
Adapters 11853A 50 Ω Type-N accessory kit
11878 A Type-N to 3.5 mm adapter kit
Calibration kits
Calibration is an accuracy enhancement procedure that effectively reduces the system errors that cause uncertainty in network measurement. Calibration kit is necessary to perform the calibration.
– Mechanical calibration kits include standards, such as opens, shorts and loads, which are measured by the network analyzer.
Choose a calibration kit for each connector type to be used.
– Electronic calibration (ECal) modules replace mechanical calibration standards with one solid-state calibration module that is
controlled by the network analyzer via USB. ECal modules provide many different impedances to the test ports which enables a full two-port calibration to be performed quickly with a single connection. This technique reduces operator errors and connector wear and abrasion.
Category Product Number Description
Mechanical calibration kits 85032F Standard Mechanical Calibration Kit, DC to 9 GHz, Type-N, 50 Ω
85054D Economy Mechanical Calibration Kit, DC to 18 GHz, Type-N, 50 Ω
Electronic calibration kits 85092C RF ECal: 300 kHz to 9 GHz, 2 ports, Type-N, 50 Ω
N4 431B Microwave ECal: 9 kHz to 13.5 GHz, 4 ports
N4432A Microwave ECal: 300 kHz to 18 GHz, 4 ports
N4690C Microwave ECal: 300 kHz to 18 GHz, 2 ports, Type-N, 50 Ω
Literature Resource
Description Publication number
E5063A Network Analyzer Data Sheet 5991-3615EN
E5063A Network Analyzer Brochure 5991-3614EN
E5063A PCB Analyzer Technical Overview 5991-3617EN
Network Analyzers Selection Guide 5989-7603EN
More literature is available on our web site.
Web Resource
Get the latest news, product and suppor t information, application literature and more.
http://www.keysight.com/find/e5063a
Page 6
06 | Keysight | E5063A ENA Series Network Analyzer - Configuration Guide
Evolving
Our unique combination of hardware, software, suppor t, and people can help you reach your next breakthrough. We are unlocking the future of technology.
From Hewlett-Packard to Agilent to Keysight
myKeysight www.keysight.com/find/mykeysight
A personalized view into the information most relevant to you.
Keysight Services www.keysight.com/find/service
Our deep offering in design, test, and measurement services deploys an industry-leading array of people, processes, and tools. The result? We help you implement new technologies and engineer improved processes that lower costs.
Three-Year Warranty www.keysight.com/find/ThreeYearWarranty
Keysight’s committed to superior product quality and lower total cost of ownership. Keysight is the only test and measurement company with three-year warranty standard on all instruments, worldwide. And, we provide a one-year warranty on many accessories, calibration devices, systems and custom products.
Keysight Assurance Plans www.keysight.com/find/AssurancePlans
Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements.
Keysight Channel Partners www.keysight.com/find/channelpartners
Get the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience.
For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at:
www.keysight.com/find/contactus
Americas
Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444
Asia Pacific
Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 11 2626 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100
Europe & Middle East
Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353
Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT)
United Kingdom 0800 0260637
For other unlisted countries: www.keysight.com/find/contactus
(B P-11- 29 -16)
www.keysight.com/find/e5063a
DEKRA Certified
ISO9001 Quality Management System
www.keysight.com/go/quality
Keysight Technologies, Inc. DEKRA Certified ISO 9001:2015 Quality Management System
This information is subject to change without notice. © Keysight Technologies, 2013 - 2017 Published in USA, January 18, 2017 5991-3616EN