Keysight E5052B Installation Manual

Page 1
Keysight E5052B Signal Source Analyzer
Installation Guide
Page 2
Notices
© Keysight Technologies
2007-2018
No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Keysight Technologies, Inc. as governed by United States and international copyright laws.
Trademark Acknowledgments
Manual Part Number
E5052-90046
Edition
Edition 7, February 2018
COVERING THE MATERIAL IN THIS DOCUMENT THAT CONFLICT WITH THESE TERMS, THE WARRANTY TERMS IN THE SEPARATE AGREEMENT WILL CONTROL.
Technology Licenses
The hard ware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license.
Declaration of Conformity
Declarations of Conformity for this product and for other Keysight products may be downloaded from the Web. Go to
http://www.keysight.com/go/confor mity. You can then search by product
number to find the latest Declaration of Conformity.
perform, display, or disclose commercial computer software or commercial computer software documentation. No additional government requirements beyond those set forth in the EULA shall apply, except to the extent that those terms, rights, or licenses are explicitly required from all providers of commercial computer software pursuant to the FAR and the DFARS and are set forth specifically in writing elsewhere in the EULA. Keysight shall be under no obligation to update, revise or otherwise modify the Software. With respect to any technical data as defined by FAR
2.101, pursuant to FAR 12.211 and
27.404.2 and DFARS 227.7102, the U.S. government acquires no greater than Limited Rights as defined in FAR
27.401 or DFAR 227.7103-5 (c), as applicable in any technical data.
Printed in Malaysia
Published by:
Keysight Technologies International Japan G.K,
1-3-3 Higashikawasaki-cho Chuo-ku Kobe-shi, Hyogo, Japan
Warranty
THE MATERIAL CONTAINED IN THIS DOCUMENT IS PROVIDED “AS IS,” AND IS SUBJECT TO BEING CHANGED, WITHOUT NOTICE, IN FUTURE EDITIONS. FURTHER, TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, KEYSIGHT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED WITH REGARD TO THIS MANUAL AND ANY INFORMATION CONTAINED HEREIN, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. KEYSIGHT SHALL NOT BE LIABLE FOR ERRORS OR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, USE, OR PERFORMANCE OF THIS DOCUMENT OR ANY INFORMATION CONTAINED HEREIN. SHOULD KEYSIGHT AND THE USER HAVE A SEPARATE WRITTEN AGREEMENT WITH WARRANTY TERMS
U.S. Government Rights
The Software is “commercial computer software,” as defined by Federal Acquisition Regulation (“FAR”) 2.101. Pursuant to FAR
12.212 and 27.405-3 and Department of Defense FAR Supplement (“DFARS”) 227.7202, the U.S. government acquires commercial computer software under the same terms by which the software is customarily provided to the public. Accordingly, Keysight provides the Software to U.S. government customers under its standard commercial license, which is embodied in its End User License Agreement (EULA), a copy of which can be found at
http://www.keysight.com/find/sweul a The license set forth in the EULA
represents the exclusive authority by which the U.S. government may use, modify, distribute, or disclose the Software. The EULA and the license set forth therein, does not require or permit, among other things, that Keysight: (1) Furnish technical information related to commercial computer software or commercial computer software documentation that is not customarily provided to the public; or (2) Relinquish to, or otherwise provide, the government rights in excess of these rights customarily provided to the public to use, modify, reproduce, release,
Safety Notices
A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met.
A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met.
This NOTE sign denotes important information. It calls attention to a procedure, practice, or condition that is essential for the user to understand.
Page 3
Keysight E5052B Signal Source Analyzer
Installation Guide
Safety Summary
The following general safety precautions must be observed during all phases of operation, service, and repair of this instrument. Failure to comply with these precautions or with specific WARNINGS elsewhere in this manual may impair the protection provided by the equipment. Such noncompliance would also violate safety standards of design, manufacture, and intended use of the instrument. Keysight Technologies assumes no liability for the customer’s failure to comply with these precautions.
The E5052B complies with INSTALLATION CATEGORY II as well as POLLUTION DEGREE 2 in IEC61010-1. The E5052B is an INDOOR USE product.
The LEDs in the E5052B are Class 1 in accordance with IEC60825-1, CLASS 1 LED PRODUCT.
Ground the Instrument
To avoid electric shock, the instrument chassis and cabinet must be grounded with the supplied power cable’s grounding prong.
DO NOT Operate in an Explosive Atmosphere
Do not operate the instrument in the presence of inflammable gases or fumes. Operation of any electrical instrument in such an environment clearly constitutes a safety hazard.
Keep Away from Live Circuits
Operators must not remove instrument covers. Component replacement and internal adjustments must be made by qualified maintenance personnel. Do not replace components with the power cable connected. Under certain conditions, dangerous voltage levels may remain even after the power cable has been disconnected. To avoid injuries, always disconnect the power and discharge circuits before touching them.
DO NOT Service or Adjust the Instrument Alone
Do not attempt internal service or adjustment unless another person, capable of rendering first aid and resuscitation, is present.
DO NOT Substitute Parts or Modify the Instrument
3
Page 4
-
Safety Summary Safety Summary
To avoid the danger of introducing additional hazards, do not install substitute parts or perform unauthorized modifications to the instrument. Return the instrument to a Keysight Technologies Sales and Service Office for service and repair to ensure that safety features are maintained in operational condition.
Dangerous Procedure Warnings
Warnings, such as the example below, precede potentially dangerous procedures throughout this manual. Instructions contained in the warnings must be followed.
Dangerous voltage levels, capable of causing death, are present in this instrument. Use extreme caution when handling, testing, and adjusting this instrument.
4 Keysight E5052B Signal Source Analyzer
Page 5
Safety Symbols
Safety Summary Safety Symbols
General definitions of safety symbols used on the instrument or in manuals are listed below.
Instruction Manual symbol: the product is marked with this symbol when it is necessary for the user to refer to the instrument manual.
Alternating current.
Direct current.
On (Supply).
Off (Supply).
Certification
Keysight Technologies certifies that this product met its published specifications at the time of shipment from the factory. Keysight Technologies further certifies that its calibration measurements are traceable to the United States National Institute of Standards and Technology, to the extent allowed by the Institution’s calibration facility or by the calibration facilities of other International Standards Organization members.
Exclusive Remedies
The remedies provided herein are Buyer’s sole and exclusive remedies. Keysight Technologies shall not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any other legal theory.
A chassis terminal; a connection to the instrument’s chassis, which includes all exposed metal structure.
Standby.
Assistance
Product maintenance agreements and other customer assistance agreements are available for Keysight Technologies products.
For any assistance, contact your nearest Keysight Technologies Sales and Service Office. Addresses are provided at the back of this manual.
Keysight E5052B Signal Source Analyzer 5
Page 6
-
Safety Summary Safety Symbols
6 Keysight E5052B Signal Source Analyzer
Page 7
Table o f Contents
1. Introduction
Manuals for E5052B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Contents of This Manual. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2. Installation
Checking the Shipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Environmental Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Operating Environments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Ventilation Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Protection Against Electrostatic Discharge (ESD). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Ensuring Adequate Free Space around Analyzer for Immediate Disconnection of Power
Cable in Case of Emergency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Installing Front Handles/Rack Mounting Flanges. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
How to Install the Handle Kit (Option 1CN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
How to Install the Rack-mount Kit (Option 1CM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
How to Install the Rack-mount and Handle Kit (Option 1CP) . . . . . . . . . . . . . . . . . . . . . 18
Contents
Connecting the Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Connecting Mouse and Keyboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Verification of the Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Verification and Connection of Power Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Blown fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Starting the E5052B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Turning the Power ON and OFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Disconnection from Supply Source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Removing / Mounting Removable Hard Disk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Initial Registration of E5052B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Windows 7 (HDD Revision NWxxx) and Windows 10 (HDD Revision NHxxx) . . . . . . . . . 26
Windows Vista Business (HDD Revision: NM321 or above) . . . . . . . . . . . . . . . . . . . . . . . 26
Windows Vista Business (HDD Revision: NM320 or below) . . . . . . . . . . . . . . . . . . . . . . . 30
Windows XP Pro for Embedded Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Online Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
3. Troubleshooting
Troubleshooting during Startup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
System Recovery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Keysight E5052B Installation Guide 7
Page 8
Contents
Types of system recoveries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
Factory Recovery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
User Recovery (only for HDD Revision NM320 or below) . . . . . . . . . . . . . . . . . . . . . . . . .52
8 Keysight E5052B Installation Guide
Page 9
Keysight E5052B Signal Source Analyzer
Installation Guide
1 Introduction
This chapter introduces the documentation for Keysight E5052B and the overview of this manual to use this manual efficiently. See this manual first when you use the E5052B for the first time.
Manuals for E5052B
Keysight provides the following three manuals for the E5052B. The latest version of all documentations can be downloaded from
http://www.keysight.com/find/e5052b-manual.
o Installation Guide
The installation guide (this manual) provides start up setup information when you use the E5052B for the first time and troubleshooting information when the Windows cannot be boot up.
o Online Help
The Online Help provides the information about the measurement operation, programming, built-in VBA, I/O interface This is pre-installed in the E5052B. Press [Help] hard key on the front panel to open.
o Service Guide
The service manual provides information about the parts, troubleshooting, performance test, adjustment and service menu.
9
Page 10
1-
Introduction Contents of This Manual
Contents of This Manual
The following shows the contents of this manual.
o Chapter 1, “Introduction.”
This chapter introduces the documentation for Keysight E5052B and the overview of this manual to use this manual efficiently. See this manual first when you use the E5052B for the first time.
o Chapter 2, “Installation.”
This chapter provides information about how to set up the Keysight E5052B.
o Chapter 3, “Troubleshooting.”
This chapter describes the troubleshooting during start up and the procedure of the operating system (OS) recovery when the Windows OS has been damaged.
10 Keysight E5052B Signal Source Analyzer
Page 11
Keysight E5052B Signal Source Analyzer
Installation Guide
2 Installation
This chapter provides information about how to set up the Keysight E5052B.
Contents of this Chapter
o “Checking the Shipment” on page 12
After you receive the analyzer, check all the items in the packing container.
o “Environmental Requirements” on page 13
Describes the system requirements needed to install the E5052B and how to secure space for heat radiation.
o “Installing Front Handles/Rack Mounting Flanges” on page 16
Shows how to mount the front handles used to transport the E5052B and how to install the flanges needed to install it in a rack.
o “Connecting the Accessories” on page 19
Provides information for connecting the mouse, keyboard, BNC adaptor to the E5052B.
o “Power Supply” on page 20
Shows how to check the power supply as well as check and connect the power cable.
o “Starting the E5052B” on page 23
Describes turning on/off of the Power switch and cutting off the power supply.
o “Initial Registration of E5052B” on page 26
Provides the procedure of initial registration for the Windows operating system of the E5052B.
11
Page 12
2-
Installation Checking the Shipment
Checking the Shipment
After you receive the analyzer, carry out checks during unpacking according to the following procedure.
When unpacking the analyzer, if the external face of the analyzer (such as the cover, front/rear panel, LCD screen, power switch, and port connectors) appear to be damaged during transport, do not turn on the power switch. Otherwise, you may get an electric shock.
Step 1. Check that the packing box or shock-absorbing material used to package the
analyzer has not been damaged.
If the packing box or shock-absorbing material has been damaged, leave the packing box and shock-absorbing material as is until other inspection items are checked as follows:
Step 2. Check the packaged items supplied with the analyzer for any damage or
defects.
Step 3. By referring to the furnished contents list, check that all packaged items
supplied with the analyzer have been provided as per the specified options.
Step 4. After checking, if one of the following applies, contact your nearest Keysight
Technologies sales and service office.
1. The packing box or shock-absorbing material used to package the analyzer has been damaged or the shock-absorbing material has traces where extreme force has been applied.
2. A packaged item supplied with the analyzer has mechanical damage or defects.
3. A packaged item supplied with the analyzer is missing.
4. A fault has been detected in the subsequent operation check of the analyzer.
If an abnormality is detected in step 1, contact the company that transported the analyzer as well as your nearest Keysight Technologies sales and service office. For inspection by the transport company, save the packing box, shock-absorbing material, and packaged items as you received them.
12 Keysight E5052B Signal Source Analyzer
Page 13
Installation Environmental Requirements
Environmental Requirements
Set up the E5052B where the following environmental requirements are met.
Operating Environments
Ensure that the operating environment meets the following requirements.
Temperature 10ºC to 40ºC
Temperature range at the error-correction
23ºC 5ºC (< 1ºC deviation from the temperature when performing the error-correction)
Humidity 20% to 80% at wet bulb temperature < +29ºC
(non-condensation)
Altitude 0 to 2,000 m (0 to 6,561 feet)
Vibration 0.21 G maximum, 5 Hz to 500 Hz
Above environmental requirements are NOT for the specifications and measurement accuracy of the analyzer, but for the operating environment of the analyzer.
Keysight E5052B Signal Source Analyzer 13
Page 14
2-
Installation Environmental Requirements
Ventilation Requirements
To ensure safety requirements, the specifications and measurement accuracy of the analyzer, you must keep environmental temperature within the specified range by providing appropriate cooling clearance around the analyzer or, for the rackmount type, by forcefully air-cooling inside the rack housing. For more information on environmental temperature to satisfy the specifications and measurement accuracy of the analyzer, see the specification in the E5052B Online Help.
When the environmental temperature around the analyzer is kept within the temperature range of the operating environment specification (See Section
“Operating Environments” on page 13), the analyzer conforms to the
requirements of the safety standard. Furthermore, under that temperature requirement, the analyzer still conforms to the requirements of the safety standard even when placing the analyzer with cooling clearance as follows:
Requirements
Back 180 mm
Sides 60 mm (both right and left)
Figure 2-1 Ventilation space at the installation
When measuring place the E5052B in a proper position as show in Figure
2-1.
14 Keysight E5052B Signal Source Analyzer
Page 15
Installation Environmental Requirements
Protection Against Electrostatic Discharge (ESD)
Set up a static-safe work-station to protect the electronic components from the damage by the electrostatic discharge (ESD) as shown in Figure 2-2.
Figure 2-2 Example of the static-safe work-station
Ensuring Adequate Free Space around Analyzer for Immediate Disconnection of Power Cable in Case of Emergency
As described in “Disconnection from Supply Source” on page 25, the power supply is disconnected by removing the power cable’s connector plug from either the AC outlet or the E5052B unit. When installing the E5052B, ensure that there is sufficient free space around the unit to permit quick disconnection of the plug (from AC outlet or E5052B unit) in case of emergency.
Keysight E5052B Signal Source Analyzer 15
Page 16
2-
Installation Installing Front Handles/Rack Mounting Flanges
Installing Front Handles/Rack Mounting Flanges
The E5052B can be installed on a workbench or in a rack. This section describes how to install the front handles (Option 1CN) used for moving or transporting the instrument, and how to install the analyzer in an equipment rack as part of a measurement system (Option 1CM: without the handles, Option 1CP: with the handles).
Table 2-1 Keysight E5052B handles/rack mounting options
Option Name Keysight Part
Number
1CN Handle Kit 5063-9230
1CM Rack-mount Kit 5063-9217
1CP Rack-mount and Handle Kit 5063-9224
Table 2-2 Contents of each option
Option Contents Quantity
1CN Front Handles 2
Screws 6
Trim Strips 2
1CM Rack-mounting flanges (locking side plate) 2
Screws 6
1CP Rack-mounting flanges (locking side plate) 2
Front Handles 2
Screws 8
16 Keysight E5052B Signal Source Analyzer
Page 17
Installation Installing Front Handles/Rack Mounting Flanges
Figure 2-3 Installing front handle/rack-mount kits
How to Install the Handle Kit (Option 1CN)
The handle kit is used for transport and relocation of the E5052B. While referring to Figure 2-3, install the handle kit by following these steps.
Step 1. Remove the adhesive-backed trim strip (1) from each side of the outer frame
of the E5052B front panel.
Step 2. Use the provided screws to mount the front handles (2) on each side of the
E5052B front panel frame.
Step 3. Attach the provided modified trim strip (3) to each front handle in order to
cover the front panel locking screws.
If the installed front handle becomes damaged, replace it with a new one immediately. A damaged handle can break while moving or lifting the instrument and cause personal injury or damage to the instrument.
Keysight E5052B Signal Source Analyzer 17
Page 18
2-
Installation Installing Front Handles/Rack Mounting Flanges
How to Install the Rack-mount Kit (Option 1CM)
The rack-mount kit includes two flanges (locking side plates) for mounting the E5052B on a rack (482.6 mm/19 inches) conforming to the EIA Standard. While referring to Figure 2-3, install the rack-mount kit by following these steps.
Step 1. Remove the adhesive-backed trim strip (1) from each side of the outer frame
of the E5052B front panel.
Step 2. Use the provided screws to mount a rack-mounting flange (4) on each side of
the E5052B front panel frame.
Step 3. Remove the four bottom feet of the E5052B (lift the bar marked TAB on the
inner side of the foot and slide the foot toward the bar).
Step 4. Mount the E5052B on the rack.
How to Install the Rack-mount and Handle Kit (Option 1CP)
The rack-mount and handle kit includes both the rack-mounting flanges (locking side plates) and front handles. While referring to Figure 2-3, install the rack-mount kit by following these steps.
Step 1. Remove the adhesive-backed trim strip (1) from each side of the outer frame
of the E5052B front panel.
Step 2. Use the provided screws to mount a front handle (2) and rack-mounting
flange (4) on each side of the E5052B front panel frame.
Use both a front handle and a rack-mounting flange in the same time certainly. Do not attempt to install flanges or handles separately with hard ware provided. Serious electrical damage will occur to the instrument.
Step 3. Remove the four bottom feet of the E5052B (lift the bar marked TAB on the
inner side of the foot and slide the foot toward the bar).
Step 4. Mount the E5052B on the rack.
18 Keysight E5052B Signal Source Analyzer
Page 19
Installation Connecting the Accessories
Connecting the Accessories
You need to connect some accessories before use.
Connecting Mouse and Keyboard
The E5052B allows you to connect Mouse and/or keyboard through USB. USB mouse and keyboard can be connected with the USB ports on the front or rear panels.
System Recovery of the E5052B requires the keyboard before turning on the power.
Keysight E5052B Signal Source Analyzer 19
Page 20
2-
Installation Power Supply
Power Supply
Before turning on the E5052B power, check the following.
Verification of the Power Supply
Confirm that the power supplied to the E5052B meets the following requirements:
Requirements
Voltage
90 to 132 VAC or 198 to 264 VAC
1
Frequency 47 to 63 Hz
Maximum power consumption 500 VA
1. Switched automatically by the E5052B in conformity to the voltage used.
Verification and Connection of Power Cable
The three-wire power cable attached to the E5052B has one wire serving as a ground. Using this power cable allows the E5052B to be grounded, thereby protecting you against electrical shock from the power outlet.
Step 1. Confirm that the power cable is not damaged.
NEVER use a power cable showing any sign of damage. Faulty cables can cause electrical shock.
Step 2. Use the supplied cable to connect between the power cable receptacle
(Figure 2-6 on page 24) on the rear panel of the E5052B and a three-wire power outlet with the grounding prong firmly connected in the ground slot.
Use the supplied power cable with grounding wire to securely ground the E5052B.
Figure 2-4 shows the power cable options.
20 Keysight E5052B Signal Source Analyzer
Page 21
Installation Power Supply
Figure 2-4 Power cable options
Keysight E5052B Signal Source Analyzer 21
Page 22
2-
Installation Power Supply
Blown fuses
If the fuse appears to have blown during operation, this instrument may be subject to failure and must be repaired. Ship the E5052B to the nearest Keysight Technologies Service Center.
The product uses the following fuse type: UL/CSA Type, Slow-Blo, 15 A-250 V
Do NOT replace the fuse yourself; doing this may expose you to dangerous electrical shock.
22 Keysight E5052B Signal Source Analyzer
Page 23
Installation Starting the E5052B
Starting the E5052B
This section describes how to turn on/off the E5052B power and how to cut off the power supply in an emergency.
Turning the Power ON and OFF
Perform the following steps to turn the power ON or OFF.
To Check the Removable Hard Disk Drive
Procedure
When the power is turned on, it is required to confirm the notch geometry is set as follows.
If the notch geometry is not set as follows, the error message “OS not found” will be shown when you turn on the power.
Figure 2-5 Removable Hard Disk Drive
e5071cse3008
Turning the Power ON
Step 1. Confirm if the Line Switch on the rear panel is on. The switch should always
be turned on.
Step 2. If the standby switch ( ) in the lower-left part of the front panel is in the
depressed ( ) position, press it to put it in the popped up position ( ).
Step 3. Press the standby switch to put it in the depressed position ( ).
This operation turns ON the power, and the E5052B starts the self-test.
Step 4. Confirm that the self-test indicates normal operation.
Normal operation is confirmed by the self-test if no error message appears.
Keysight E5052B Signal Source Analyzer 23
Page 24
2-
Installation Starting the E5052B
Turning the Power OFF
Step 1. Use either of the following methods to turn the power OFF.
Press the standby switch ( ) in the lower-left part of the front panel (now
in the pressed down ( ) position) to put it in the popped up ( ) position.
Click Turn off Computer from Windows Start menu
These operations will start the E5052B shutdown process (required software and hardware processes for turning the power off), and the power will turn OFF after a few seconds.
Under normal circumstances, always press the standby switch ( ), or click Turn off Computer from Windows Start menu, to execute the E5052B shutdown process. Never cut off the power supply directly by
disconnecting the power cable plug from the rear panel of the unit.
If the power supply is cut off directly by disconnecting the power cable plug from the instrument or the AC outlet, the shutdown process is not carried out and there is a risk of damage to the E5052B’s software or hard ware.
Figure 2-6 Line switch (Always ON) and power cable receptacle
24 Keysight E5052B Signal Source Analyzer
Page 25
Installation Removing / Mounting Removable Hard Disk
Disconnection from Supply Source
The power supply of the E5052B is cut off by disconnecting the plug of the power cable (on either AC outlet side or E5052B side). When it is necessary to disconnect the power supply in order to avoid shock hazards, etc., pull out the power cable plug from either the AC outlet side or the E5052B side.
To allow this operation to be performed smoothly, be sure to follow the guidelines in “Ensuring Adequate Free Space around Analyzer for
Immediate Disconnection of Power Cable in Case of Emergency” on page 15.
When turning the power OFF under normal circumstances, always follow the methods described in “Turning the Power OFF” on page 24.
Removing / Mounting Removable Hard Disk
For details of removing / mounting removable hard disk, refer to the following website http://ena.support.keysight.com/e5052b/manuals/webhelp/eng/
Keysight E5052B Signal Source Analyzer 25
Page 26
2-
Installation Initial Registration of E5052B
Initial Registration of E5052B
When you start up the E5052B at the first time, you need to perform the initial registration for Windows operating system of E5052B.
There are three methods of initial registration procedure depending on the windows licenses and HDD revisions of E5052B:
- Windows Vista Business (HDD Revision: NM321 or above)
- Windows Vista Business (HDD Revision: NM320 or below)
- Windows XP Pro fro Embedded Systems
- Windows 7 (HDD Revision NWxxx)
- Windows 10 (HDD Revision NHxxx)
The license is shown at the Windows License label on the rear panel of E5052B.
It is not possible to check the HDD revision installed on your E5052B before Windows is booted. Therefore, you should follow the procedures below.
For Windows Vista Business and Windows XP, you cannot use the front panel keys during the initial registration of the E5052B therefore connect the mouse and the keyboard before turning on the power.
If you perform the following procedure incorrectly, a message asking you whether to return to the previous registration screen and perform the registration appears. In this case, follow the instruction to return to the previous registration screen.
Windows 7 (HDD Revision NWxxx) and Windows 10 (HDD Revision NHxxx)
When you start up the E5052B for the first time, you need to perform the initial registration of the Windows operating system of the E5052B.
When the Windows agreement message box appears, click Agree. The rest of the procedure runs automatically.
Windows Vista Business (HDD Revision: NM321 or above)
Step 1. Turn on the E5052B.
Step 2. The Windows XP Professional Setup wizard appears. Click the Next > button
(Figure 2-7).
26 Keysight E5052B Signal Source Analyzer
Page 27
Installation
e5071cse1073 e5071cse1074
Initial Registration of E5052B
Figure 2-7 Windows XP Professional Setup wizard
Step 3. In the Windows XP Professional Setup dialog box, read the license
agreement, then select the I accept this agreement box and click the Next > button (Figure 2-8).
Figure 2-8 Windows XP Professional Setup dialog box (1/2)
Step 4. In the next dialog box, input E5052 in the Name box. Then, click the Next>
button (Figure 2-9).
Keysight E5052B Signal Source Analyzer 27
Page 28
2-
e5052bse1033
E5052
Installation Initial Registration of E5052B
Figure 2-9 Windows XP Professional Setup dialog box (2/2)
Step 5. The E5052B restart automatically.
Step 6. The Keysight Recovery Image Setup screen (Figure 2-10) appears. Click OK to
proceed.
Figure 2-10 Keysight Recovery Image Setup Screen(1/1)
Step 7. A progress bar appears (Figure 2-11) indicating the progress of the Recovery
Image setup. The complete process takes less than 5 minutes to finish.
28 Keysight E5052B Signal Source Analyzer
Page 29
Installation Initial Registration of E5052B
Figure 2-11 Keysight Recovery Image Setup Screen(1/2)
Step 8. A message dialog box appears after the completion of the Recovery Image
Setup procedure. The dialog box disappears automatically after a few seconds.
Step 9. The E5052B firmware is executed, then the measurement display appears.
Keysight E5052B Signal Source Analyzer 29
Page 30
2-
e5071cse1073 e5071cse1074
Installation Initial Registration of E5052B
Windows Vista Business (HDD Revision: NM320 or below)
Step 1. Turn on the E5052B.
Step 2. The Windows XP Professional Setup wizard appears. Click the Next > button
(Figure 2-12).
Figure 2-12 Windows XP Professional Setup wizard
Step 3. In the Windows XP Professional Setup dialog box, select the I accept this
agreement box and click the Next > button (Figure 2-13).
Figure 2-13 Windows XP Professional Setup dialog box (1/2)
Step 4. In the next dialog box, input E5052 in the Name box. Then, click the Next>
button (Figure 2-14).
30 Keysight E5052B Signal Source Analyzer
Page 31
Installation
e5052bse1033
E5052
Initial Registration of E5052B
Figure 2-14 Windows XP Professional Setup dialog box (2/2)
Step 5. After a while, the E5052B restarts automatically. Then, the measurement
display appears.
Keysight E5052B Signal Source Analyzer 31
Page 32
2-
Installation Initial Registration of E5052B
Windows XP Pro for Embedded Systems
Step 1. Turn on the E5052B.
Step 2. The screen shown in Figure 2-15 appears. Select Windows XP Professional
and press Enter.
Figure 2-15 System start up screen in Windows XP Pro for Embedded Systems (1/2)
Step 3. The screen as shown in Figure 2-16 appears. Press Enter.
Figure 2-16 System start up screen in Windows XP Pro for Embedded Systems (2/2)
32 Keysight E5052B Signal Source Analyzer
Page 33
Installation Initial Registration of E5052B
Step 4. The windows start up screen as shown in Figure 2-17 appears.
Figure 2-17 Windows XP Pro for Embedded Systems start up screen
Step 5. In the License agreement dialog box, select the I accept this agreement box
and click the Next > button. Figure 2-18 shows the license agreement dialog box in Windows XP Pro for Embedded Systems.
Figure 2-18 Windows XP Pro for Embedded Systems license agreement dialog box
Keysight E5052B Signal Source Analyzer 33
Page 34
2-
Installation Initial Registration of E5052B
Step 6. In the next dialog box, set the date and time for your Windows. Then, click
the Next> button as shown in Figure 2-19.
Figure 2-19 Date and Time Setting dialog box
Step 7. After a while, the E5061B restarts automatically.
34 Keysight E5052B Signal Source Analyzer
Page 35
Online Help
Installation Online Help
The Online Help provides the information about the quick start, measurement operation, programming, built-in VBA, I/O interface This is pre-installed in the E5052B. Press [Help] hard key on the front panel to open. Quick Start helps in understanding the E5052B operation quickly.
The latest version of Online Help is available at
http://ena.support.keysight.com/e5052b/manuals/webhelp/eng/
Keysight E5052B Signal Source Analyzer 35
Page 36
2-
Installation Online Help
36 Keysight E5052B Signal Source Analyzer
Page 37
Keysight E5052B Signal Source Analyzer
Installation Guide
3 Troubleshooting
This chapter describes the troubleshooting during start up and the procedure of the operating system (OS) recovery when the Windows OS has been damaged.
Troubleshooting during Startup
When you encounter the problem during start up, see Table 3-1. System recovery saves most of problems.
Table 3-1 Troubleshooting during startup
Symptom Solution
Turning on (|) the standby switch does not start up the system.
The system starts up, but it automatically shuts down immediately.
The system starts up, but it enters the service mode (The instrument status bar in the lower right part of the screen displays SVC in red).
The measurement screen appears after startup, but the power on test failed, appearing against a red background in the instrument message/warning area in the lower left part of the screen.
Confirm that the power cable is properly plugged in.
Confirm that the line switch on the rear panel is turned on
Execute the system recovery.
37
Page 38
3-
Troubleshooting System Recovery
System Recovery
By executing system recovery, you can return the system of the E5052B (the Windows operating system and the firmware) to the factory state (at the time
1
of purchase
System recovery is a function of Windows and not a function of the E5052B Firmware.
The system recovery procedure is different in accordance with the Windows OS license and HDD revision. The Windows OS license and HDD revision can be confirmed using the following procedure:
Step 1. Check the Windows License label on the rear panel of the E5052B.
Step 2. In the E5052B, from Windows Start Menu, click on My Computer.
).
Step 3. The volume label for C: drive is displayed in Hard Disc Drive area.
Strictly follow the steps described below. If you do any operation other than the following steps, the system may not be recovered.
1. If the hard disk failed and has been replaced after purchase, the state when the replace­ment was performed is recovered.
38 Keysight E5052B Signal Source Analyzer
Page 39
Troubleshooting System Recovery
Types of system recoveries
The following 2 types of system recoveries are available.
o Factory recovery
Returns the contents of the C drive to factory state.
Available for all Windows OS licenses.
o User recovery (available only for Windows Vista Business with HDD revision
NM320 or below)
Returns the contents of the C and F drives to user-specified state.
To use this function, you must prepare for recovery in advance.
For more information on preparation, see “Procedure to create the user
backup image (only available when HDD Revision is NM320 or below)” on page 52 for information on execution, see “Procedure to execute the user recovery function (only available when HDD Revision is NM320 or below)” on page 59.
Factory Recovery
Notes on executing factory recovery function
Executing factory recovery function causes the following conditions:
o In addition to the Windows operating system and the firmware, the
following settings of the E5052B are returned to factory state.
•Network setting
GPIB setting
•Printer setting
o The driver for the supported printer installed after purchase is deleted.
o You need to execute initial registration again.
Files you created using the save function (files in the F drive) are not affected, but we recommend backing them up before executing system recovery for precautionary purposes. For more information on backup, refer to “Backing Up the Data” as described in E5052B Online Help.
Procedure for Windows 7/10
HDD Revision: NWxxx or NHxxx
Step 1. Connect a keyboard if Windows 10.
Step 2. Press the standby switch of the E5052B to turn it on.
Step 3. When the screen as shown in the figure below appears, select Instrument
Image Recovery System and press [Enter].
Keysight E5052B Signal Source Analyzer 39
Page 40
3-
Troubleshooting System Recovery
Figure 3-1 Instrument Image Recovery System Selection Screen
Step 4. In the Keysight Software End User License Agreement dialog box, select the
Agree button.
Step 5. Type 2 to select Recover the original factory system image option and press
[Enter].
Figure 3-2 System recovery selection screen
Step 6. A confirmation message appears. Click OK to confirm the process.
40 Keysight E5052B Signal Source Analyzer
Page 41
Troubleshooting System Recovery
Figure 3-3 System recovery information screen
Step 7. The progress of the system configuration is displayed on the screen. The
recovery takes a few minutes depending on the amount of data.
Figure 3-4 System configuration progress screen
Step 8. Once the recovery process is completed, completion message prompts. Click
OK. The E5052B restarts automatically.
Figure 3-5 Recovery completion dialog box
Keysight E5052B Signal Source Analyzer 41
Page 42
3-
Troubleshooting System Recovery
Step 9. After the restart, execute initial registration. For information on the execution
procedure, refer to “Initial Registration of E5052B” on page 26.
Never turn off the power during the system recovery because doing so may cause serious damage to the E5052B.
Procedure for Windows Vista Business
HDD Revision: NM32x
O nl y th e re co ve ry fu nc ti on fo r Fa c to ry im a ge is lo a de d.
The User backup function is not available.
You need a keyboard for this operation.
Step 1. Turn ON the E5052B.
Step 2. The boot option is displayed. Use the downward arrow key to select the
“Keysight Recovery Solution” and press Enter
Step 3. Windows PE starts up and “Keysight Recovery Program” window is d isplayed.
Press 1, and then press Enter.
Figure 3-6 Keysight Recovery Program(1/1)
Step 4. A warning message is displayed. Press 1, and then press Enter.
42 Keysight E5052B Signal Source Analyzer
Page 43
Troubleshooting System Recovery
Figure 3-7 Keysight Recovery Program(1/2)
Step 5. Caution is displayed. Press 1, and then press Enter.
Figure 3-8 Keysight Recovery Program(1/3)
Step 6. Recovery function is performed.
Step 7. A message box appears after the completion of recovery process. Press any
key to continue.
Keysight E5052B Signal Source Analyzer 43
Page 44
3-
Troubleshooting System Recovery
Figure 3-9 Keysight Recovery Program(1/4)
Step 8. When factory recovery is finished, the E5052B restarts.
Step 9. After restart, the screen for initial registration appears. Execute initial
registration. For information on the execution procedure, refer to “Windows
Vista Business (HDD Revision: NM321 or above)” on page 26.
44 Keysight E5052B Signal Source Analyzer
Page 45
Troubleshooting System Recovery
HDD Revision: NM320 or below
You need a keyboard for this operation.
Step 1. Shut down the E5052B.
Step 2. Disconnect all of the USB device from the USB ports.
Step 3. Connect the keyboard to the E5052B.
Step 4. Press the standby switch of the E5052B to turn it on.
Step 5. When the screen as shown in the figure below appears, press of the
F11
keyboard.
Starting Acronis Loader...
Press F11 for Acronis Startup Recovery Manager...
e5071cse1055
Press F11 only once. If you press F11 twice or more and a screen which is not mentioned in this manual appears, reboot the instrument and restart the process from the first.
After several seconds, the next screen appears automatically even if you do not press any key, so do not miss it.
After Step 5, if the E5052B freezes with the cursor does not blink, turn the power off and remove unnecessary USB devices. Then, replace the keyboard with a PS/2 keyboard to execute the process again.
Keysight E5052B Signal Source Analyzer 45
Page 46
3-
e5071cse1079
e5052bse1018
Troubleshooting System Recovery
Step 6. Select Restore.
Figure 3-10 Activate Acronis Startup Recovery Manager
Step 7. A confirmation dialog box is displayed. Push the enter to select Yes to start
the recovery of the factory backup. The recovery takes a few minutes depending on the amount of data.
Figure 3-11 Recover Factory Backup
Step 8. When the recovery is finished, click OK. The E5052B restarts automatically.
46 Keysight E5052B Signal Source Analyzer
Page 47
Troubleshooting System Recovery
Step 9. After restart, the screen for initial registration appears. Execute initial
registration. For information on the execution procedure, refer to “Windows
Vista Business (HDD Revision: NM320 or below)” on page 30.
Step 10. Execute the calibration of the touch screen.
Never turn off the power during the system recovery because doing so may cause serious damage to the E5052B.
Keysight E5052B Signal Source Analyzer 47
Page 48
3-
Troubleshooting System Recovery
Procedure for Windows XP Pro for Embedded Systems
Only the recovery function for Factory image is loaded.
The User back up function is not available.
You need a keyboard for this operation.
Step 1. Turn ON the E5052B.
Step 2. The boot option is displayed. Use the downward arrow key to select the
“Keysight Recovery System” and press Enter
Figure 3-12 Keysight Recovery System selection screen
After several seconds, the next screen appears automatically even if you do not press any key.
48 Keysight E5052B Signal Source Analyzer
Page 49
Troubleshooting System Recovery
Step 3. Type 2 to select Recover the original factory system image option and press
Enter.
Figure 3-13 System recovery selection screen
Step 4. A confirmation message appears. Click OK to continue the process.
Figure 3-14 System recovery confirmation screen
Step 5. The progress of the system configuration is displayed on the screen. The
recovery takes a few minutes depending on the amount of data.
Keysight E5052B Signal Source Analyzer 49
Page 50
3-
Troubleshooting System Recovery
Figure 3-15 System configuration progress screen
Step 6. Once the recovery process is completed, completion message prompts. Click
OK. The E5052B restarts automatically
Figure 3-16 Recovery Option confirmation dialog box
Step 7. Type 5 to select Exit and Restart the instrument and click OK.
Figure 3-17 System recovery selection screen
50 Keysight E5052B Signal Source Analyzer
Page 51
Troubleshooting System Recovery
Step 8. After the restart, execute initial registration. For information on the execution
procedure, refer to“Windows XP Pro for Embedded Systems” on page 32.
Never turn off the power during the system recovery because doing so may cause serious damage to the E5052B.
Keysight E5052B Signal Source Analyzer 51
Page 52
3-
e5071cse1080
Troubleshooting System Recovery
User Recovery (only for HDD Revision NM320 or below)
Procedure to create the user backup image (only available when HDD Revision is NM320 or below)
This section describes how to create the user backup image. The C and F drives’ contents saved in this procedure are recalled when the user recovery function is executed.
Step 1. Close the E5052B application by pressing System > Service Menu >
Administrator Menu > Exit E5052B > OK.
Step 2. Close all other applications you currently open.
Step 3. From the Windows start menu, select All Programs > Acronis > Acronis True
Image.
Step 4. Click “No, Thanks” button.
Figure 3-18 Recover User Backup
52 Keysight E5052B Signal Source Analyzer
Page 53
Troubleshooting
e5071cse1125
e5071cse1126
System Recovery
Step 5. Click Backup
Step 6. Click Next button.
Keysight E5052B Signal Source Analyzer 53
Page 54
3-
e5071cse1127
e5052bse1019
Troubleshooting System Recovery
Step 7. Select “The entire disk contents or individual partition,” then click Next
button.
Step 8. Select the C drive and F drive.
54 Keysight E5052B Signal Source Analyzer
Page 55
Troubleshooting
e5052bse1020
e5071cse1130
System Recovery
Step 9. Select the destination folder and input a file name, then click Next button. It
is recommended to save the file to a directory which has enough space like the D drive. Also, never save the contents of the drive to the C, E or F drive.
Step 10. Select “Set the options manually” and click Next button.
Keysight E5052B Signal Source Analyzer 55
Page 56
3-
e5071cse1131
e5071cse1132
Troubleshooting System Recovery
Step 11. Select “Backup priority” in the left field and “High” in the right field, then click
Next button.
Step 12. If necessary, input comments and click Next button. The comments can be
omitted.
56 Keysight E5052B Signal Source Analyzer
Page 57
Troubleshooting
e5052bse1021
e5052bse1022
System Recovery
Step 13. Click Proceed button.
Step 14. The following screen appears during backup.
Keysight E5052B Signal Source Analyzer 57
Page 58
3-
e5052bse1023
Troubleshooting System Recovery
Step 15. The following screen appears when the user backup image was created. Click
OK.
Never turn off the power during creating the user backup image because doing so may cause serious damage to the E5052B.
58 Keysight E5052B Signal Source Analyzer
Page 59
Troubleshooting
e5071cse1080
e5071cse1136
System Recovery
Procedure to execute the user recovery function (only available when HDD Revision is NM320 or below)
Returns the contents of the C and F drives to a user-specified state. To use this function, you must create the user backup image in advance. For more information, see the description “Procedure to create the user backup image
(only available when HDD Revision is NM320 or below)” on page 52.
Step 1. Close the E5052B application by pressing System > Service Menu > Exit.
Step 2. Close all other applications you currently open.
Step 3. From the Windows start menu, select All Programs > Acronis > Acronis True
Image.
Step 4. Click “No, Thanks” button.
Step 5. Click Recovery.
Keysight E5052B Signal Source Analyzer 59
Page 60
3-
e5071cse1137
e5052bse1024
Troubleshooting System Recovery
Step 6. Click Next button.
Step 7. Select the saved backup image file, then click Next button.
60 Keysight E5052B Signal Source Analyzer
Page 61
Troubleshooting
e5071cse1139
e5052bse1025
System Recovery
Step 8. Select “Restore disks or partitions,” then click Next button.
Step 9. Select the C drive, then click Next button.
Keysight E5052B Signal Source Analyzer 61
Page 62
3-
e5052bse1026 e5071cse1145
Troubleshooting System Recovery
Step 10. Select the C drive to restore, then click Next button.
Step 11. Select “Active” and click Next button.
62 Keysight E5052B Signal Source Analyzer
Page 63
Troubleshooting
e5052bse1027 e5071cse1147
System Recovery
Step 12. Click Next button.
Step 13. Select “Yes, I want to assign a logical drive letter to the restored partition.”
and click Next button.
Keysight E5052B Signal Source Analyzer 63
Page 64
3-
e5052bse1077
e5052bse1028
Troubleshooting System Recovery
Step 14. Select “Yes, I want to restore another partition or hard disk drive.” then click
Next button.
Step 15. Select the F drive to restore, then click Next button.
64 Keysight E5052B Signal Source Analyzer
Page 65
Troubleshooting
e5052bse1029
e5052bse1078
System Recovery
Step 16. Select the F drive to restore, then click Next button.
Step 17. Select “Logical” and click Next button.
Keysight E5052B Signal Source Analyzer 65
Page 66
3-
e5052bse1030
e5052bse1031
Troubleshooting System Recovery
Step 18. Click Next button.
Step 19. Select “Yes, I want to assign a logical drive letter to the restored partition,”
then click Next button.
66 Keysight E5052B Signal Source Analyzer
Page 67
Troubleshooting
e5052bse1079
e5052bse1080
System Recovery
Step 20. Select “No, I do not.” and click Next button.
Step 21. Select “Set the options manually” and click Next button.
Keysight E5052B Signal Source Analyzer 67
Page 68
3-
e5052bse1081
e5052bse1032
Troubleshooting System Recovery
Step 22. Select “Restoration Priority” in the left field and “High” in the right field, then
click Next button.
Step 23. Click Proceed button.
68 Keysight E5052B Signal Source Analyzer
Page 69
Troubleshooting
e5052bse1082
System Recovery
Step 24. Click Reboot button.
Never turn off the power during the recovery of the user backup image because doing so may cause serious damage to the E5052B.
Step 25. After boot up, perform “Initial Registration of E5052B” on page 26 and
Calibration of Touch Screen.
Keysight E5052B Signal Source Analyzer 69
Page 70
3-
Troubleshooting System Recovery
70 Keysight E5052B Signal Source Analyzer
Page 71
Index
A
accessories
items packaged with the
E5052B
, 12
assistance, 5
C
cable
power cable options, 20
E
environmental requirements
operation environment, 13 ventilation space, 14
Exclusive Remedies, 5
F
front handles
how to install the handle
, 17
kit
disconnection from supply
source
, 25
power cable options, 20 shutdown, 24 verification and connection of
power cable
, 20
Q
Quick Start Guide
contents, 9, 10
R
rack-mount and handle kit
how to install the rack-mount
and handle kit
, 18
rack-mount kit
how to install the rack-mount
, 18
kit Registration, 26 Removable hard disk, 25
S
H
handle and rack-mount kit
how to install the rack-mount
and handle kit
, 18
handle kit
how to install the handle
, 17
kit
I
Initial registration, 26 inspection
checking the shipment, 12
M
manual
contents, 9, 10
P
power
check the power supply, 20 disconnecting device, 25
safety
symbols, 5
shutdown
turning the power OFF, 24
system
installing rack mount
flanges
, 16
System Recovery
How to Execute, 38
W
Windows XP, 26
71 Keysight E5063A Installation Guide
Page 72
Index
72 Keysight E5063A Installation Guide
Page 73
This information is subject to change without notice.
© Keysight Technologies 2007-2018
Edition 7, February 2018
*E5052-90046*
E5052-90046
www.keysight.com