Keysight E4402B Configurations Guide

Keysight Technologies
ESA-E Series Spectrum Analyzer
Configuration Guide
Introduction
This ESA configuration guide will help you determine which performance options, measurement personalities, accessories, and services to include in your new ESA-E, or to add as upgrades to an existing ESA-E.
Keysight ESA-E Spectrum Analyzer
This step-by-step guide will help you configure your ESA-E. Capabilities that are listed as standard come with the instrument at no additional charge. Tailor the performance, exterior, and service packages to meet your requirements.
The Keysight Technologies, Inc. ESA-E spectrum analyzer is available in three express configurations: standard (STD/ STG) or communications test (COM). The express analyzers offer faster deliver y by limiting the number of options that can be ordered together. The custom configuration allows for maximum flexibility in ordering the analyzer that best meets your needs by offering all of the ESA-E options; however, it increases the delivery timeframe.
For detailed specifications, refer to the ESA-E Spectrum Analyzer specification guide (E4401-90490). For a summary of specifications, refer to the ESA-E data sheet, literature number 5989-9815EN.
ESA-E Custom Configuration
Step 1. Select your frequency range
Description ESA-E model number
Frequency range, 9 kHz to 3.0 GHz E4402B N9010A-503, frequency range, 10 Hz to 3.6 GHz Frequency range, 9 kHz to 6.7 GHz E4404B N9010A-507, frequency range, 10 Hz to 7.0 GHz Frequency range, 9 kHz to 13.2 GHz E4405B N9010A-513, frequency range, 10 Hz to 13.6 GHz Frequency range, 9 kHz to 26.5 GHz E4407B N9010A-526, frequency range, 10 Hz to 26.5 GHz
Not available N9010A-532, frequency range, 10 Hz to 32.0 GHz Not available N9010A-544, frequency range, 10 Hz to 44.0 GHz
1
EXA option number
Step 2. Included options at no additional charge
Description ESA-E spectrum analyzer EXA signal analyzer
GPIB connection Option A4H
IntuiLink PC connectivity software Connects to Microsoft® Word and Excel The PC-based EXA requires no additional software to
2
Standard on all EXA signal analyzers; in addition, the EXA offers seven USB ports and LAN connectivity as standard.
connect to Microsoft applications
Step 3. Choose frequency reference
Description ESA-E spectrum analyzer EXA signal analyzer
Frequency reference (standard aging rate) ±2 x 10–6 / year ±1 x 10–6 / year High-stability frequency reference
(reduces frequency drift resulting in more accurate measurements; recommended option)
Option 1D5 Aging rate: ±1 x 10–7 / year
N9010A-PFR Aging rate: ±1 x 10–7 / year
Step 4. Choose an attenuator
Description ESA-E spectrum analyzer EXA signal analyzer
Mechanical attenuator (standard) 5 dB steps, 0 to 60 dB 10 dB steps, 0 to 60 dB
Fine-step mechanical attenuator Not available N9010A-FSA
Allows 2 dB steps for the full 60 dB range of the mechanical attenuator
Electronic at tenuator up to 3.6 GHz Not available N9010A-EA3
Add to the mechanical attenuator; 1 dB steps, 0 to 24 dB
Step 5. Add a preamplifier
Description ESA-E spectrum analyzer EXA signal analyzer
Preamplifier Option 1DS
1 MHz to 3 GHz
1. The E4402B has six available expansion slots for additional hardware options: the E4404/05/07B has five available expansion slots
2. Requires one expansion slot
N9010A-P03, frequency range, 100 kHz to 3.6 GHz N9010A-P07, frequency range, 100 kHz to 7.0 GHz N9010A-P13, frequency range, 100 kHz to 13.6 GHz N9010A-P26, frequency range, 100 kHz to 26.5 GHz N9010A-P32, frequency range, 100 kHz to 32.0 GHz N9010A-P44, frequency range, 100 kHz to 44.0 GHz
3
ESA-E Custom Configuration – c ontinued
Step 6. Add extra options
1
Description ESA-E spectrum analyzer EXA signal analyzer
Narrow resolution bandwidths (recommended option)
Low-emissions shielding Option 060 Wide-offset phase noise improvement and
ACPR dynamic range extension Replace GPIB with serial port Option 1AX Time-gated spectrum analysis Options 1D6 Standard 50 Ω tracking generator Option 1DN, 9 kHz to 3 GHz Not available (available on CXA) Fast time domain sweep; IF, sweep,
and video output ports External mixing Option AYZ Digital demodulation hardware Option B7D/B7E
APC 3.5 mm input connector Option BAB Low frequency extension to 100 Hz Option UKB EMI detectors and FM Demodulation Option AYQ
1. If two or more ESA-E options are ordered, memory size may limit the number of options that may be loaded at any one time; for detailed information about memory size limitations, please see the Web site: http://sa.tm.keysight.com/ESA/memory
2. Not compatible with Option B7B
3. Requires one expansion slot
4. Not compatible with Option A4H
5. E4407B only
6. Requires Option 1D5; occupies two expansion slots, must be ordered jointly
7. Requires Option 1DR
Option 1DR Standard
Option 120
Option AYX
2
3
3,4
3
5
6
Not available Similar performance standard
Serial port unavailable; USB is standard
Fast time domain sweep is standard
EXA Option EXM (available with EXA Option 532 or 544) 25 MHz analysis bandwidth standard; 40 MHz optional
(10 MHz analysis bandwidth)
5
7
3,7
Not available EXA operational from 10 Hz EXA Option EMC provides EMI detectors; N9063A provides analog
demodulation including FM demodulation
4
Loading...
+ 9 hidden pages