Keysight DSO 1000 X Selection Guide

InfiniiVision Oscilloscope Probes and Accessories
For 1000 X-, 2000 X-, 3000A/T X-, 4000 X-, 6000 X-, 5000, 6000, and 7000 Series
SELECTION GUIDE

Introduction

Table of Contents
Introduction....................................................................................................................................................2
Probe Compatibility Table .............................................................................................................................3
Passive Probes ............................................................................................................................................... 5
Extreme Temperature Passive Probe ............................................................................................................ 9
High-voltage Passive Probes ...................................................................................................................... 10
InfiniiMax Active Probes and Accessories ................................................................................................... 11
InfiniiMode Active Probes and Accessories ................................................................................................ 13
High-voltage Differential Active Probes – DP0001A High-Voltage Differential Probe ............................. 15
High-voltage Differential Active Probes ..................................................................................................... 17
Single-ended Active Probes ........................................................................................................................ 21
Mixed Signal Oscilloscope Logic Probes .....................................................................................................23
Clamp-on Current Probes ........................................................................................................................... 25
N7040A/41A/42A Rogowski Coil AC Current Probes .................................................................................29
High-sensitivity Current Probes .................................................................................................................. 30
Wedge Probe Adapters ...............................................................................................................................32
Miscellaneous Accessories .......................................................................................................................... 33
T2A Probe Interface Adapter ......................................................................................................................35
Recommended Probes for Low-/Mid-speed Bus Measurements ..............................................................36
Find us at www.keysight.com
Page 2

Probe Compatibility Table

For ordering information when replacing your probe or probe accessory: Refer directly to the page number listed in the Table of Contents for your probe model.
To assist you in selecting the proper probe for your application: Use our probe compatibility table below to find the probes that are recommended for use with your 1000 X-, 2000 X-, 3000A/T X-, 4000 X-, 6000 X-, 5000, 6000, and 7000 Series InfiniiVision oscilloscope.
Probe type Probe model DSO 1000 X
Passive probes, page 5
High-voltage passive probe, page 10
Differential active probes, page 11
Single-ended active probes, page 19
MSO logic probes, page 21
Current probes, page 23
N2142A 10:1/1:1 75 MHz (included in 1000 X 50 MHz models) Recommended
N2140A 10:1/1:1 200 MHz (included in 1000 X 70/100 MHz models) Recommended N2862B/N2841A 10:1 150 MHz (included in 70/100 MHz models) Recommended Recommended Recommended Recommended
N2863B/N2842A 10:1 300 MHz (included in 200 MHz models) Recommended Recommended Recommended Recommended N2890A/N2843A 10:1 500 MHz (included in 350/500 MHz /1 GHz
models) N2840A 10:1 50 MHz Recommended Recommended Recommended Recommended
N2853A 10:1 350 MHz Recommended Recommended Recommended Recommended
N2894A 10:1 700 MHz (included in 4000 X /6000 X models) Recommended Compatible Compatible Recommended
N2889A 1:1/10:1 350 MHz Recommended Recommended Recommended Recommended N7007A 10:1 400 MHz Recommended Recommended Recommended Recommended 10076C 100:1, 3.7 kV Recommended Recommended Recommended Recommended
1130B to 1134B 1.5 to 7 GHz Incompatible Incompatible Recommended Recommended N2750A to N2752 A 1.5 to 6 GHz Incompatible Incompatible Recommended Recommended N2791A 25 MHz Recommended Recommended Recommended Recommended N2891A 70 MHz Recommended Recommended Recommended Recommended N2790A 100 MHz (with AutoProbe) Incompatible Incompatible Recommended Recommended N2792A 200 MHz Incompatible Incompatible Recommended Recommended N2818A 200 MHz (with AutoProbe) Incompatible Incompatible Recommended Recommended DP0001A 400 MHz (with AutoProbe) Incompatible Incompatible Recommended 3Recommended N2793A 800 MHz Incompatible Incompatible Recommended Recommended N2819A 800 MHz (with AutoProbe) Incompatible Incompatible Recommended Recommended N2804A 300 MHz Incompatible Incompatible Recommended Recommended N2805A 200 MHz Incompatible Incompatible Recommended Recommended N2795A 1 GHz (with AutoProbe) Incompatible Incompatible Recommended Recommended N2796A 2 GHz (with AutoProbe) Incompatible Incompatible Recommended Recommended N2797A 1.5 GHz (with AutoProbe) Incompatible Incompatible Recommended Recommended N7020A 2 GHz Incompatible Incompatible Recommended Recommended 01650 -61607 16 -channel Incompatible Incompatible Recommended Recommended N2755A 8-channel MSO cable (included in 2000 X-Series MSOs) Incompatible Recommended Incompatible Incompatible N2756A 16-channel MSO cable (included in 3000, 4000, and 6000
X-Series MSOs) 1146B 100 kHz Recommended Recommended Recommended Recommended N2780B 2 MHz (use with N2779A) Compatible Recommended Recommended Recommended N2781B 10 MHz (use with N2779A) Compatible Recommended Recommended Recommended N2782B 50 MHz (use with N2779A) Compatible Recommended Recommended Recommended N2783B 100 MHz (use with N2779A) Compatible Recommended Recommended Recommended 1147B 50 MHz (with AutoProbe) Incompatible Incompatible Recommended Recommended N2893A 100 MHz (with AutoProbe) Incompatible Incompatible Recommended Recommended N7026A 150 MHz (with AutoProbe) Incompatible Incompatible Recommended Recommended N2820A 3 MHz/50 µA high sensitivity, 2 channel (with AutoProbe) Incompatible Incompatible Recommended Recommended N2821A 3 MHz /50 µA high sensitivity, 1 channel (with AutoProbe) Incompatible Incompatible Recommended Recommended N70 40A /41A/42 A Rogowski coil Recommended Recommended Recommended Recommended
Recommended Recommended Recommended Recommended
Incompatible Incompatible Recommended Recommended
1
MSO/DSO 2000 X
1
MSO/DSO 3000A/T X
MSO/DSO 4000 X/6000 X
2
1. The 1000 X, 2000 X-Series does not support AutoProbe interface active probes.
2. The 4000 X- and 6000 X-Series comes with the Infiniium AutoProbe interface for higher probe power support.
3. DP00 01A is not compatible with the 3000A X-Series oscilloscope.
Find us at www.keysight.com
Page 3
Probe Compatibility Table (Continued)
Probe type Probe model DSO5000A
100 MHz
Passive probes, page 5
High-voltage passive probe, page 10
Differential active probes, page 11
Single-ended active probes, page 19
Mixed signal oscilloscope logic probes 2, page 21
Current probes, page 23
N2863B 10:1 300 MHz (included in 5000 Series 100/300 MHz)
10070D 1:1 20 MHz Recommended Recommended Recommended Recommended 10073D 10:1 500 MHz (included in
6000/7000 Series 300 MHz to 1 GHz and 5000 Series 500 MHz)
10074D 10:1 150 MHz (included in 6000 Series 100 MHz)
N2873A 10: 1 500 MHz (optional to 7000B) Recommended Recommended Compatible Recommended
N7007A 10:1 400 MHz Recommended Recommended Recommended Recommended 10076C 100:1 3.7 kV Recommended Recommended Recomm ended Recommended
1130B to 1134B 1.5 to 7 GHz N2750A 1.5 GHz Incompatible Incompatible Incompatible Incompatible N2791A 25 MHz Recommended Recommended Recommended Recommended N2891A 70 MHz Recommended Recommended Recommended Recommended N2790A 100 MHz (with AutoProbe) Recommended Recommended Incompatible Recommended N2792A 200 MHz Recommended Recommended Incompatible Recommended N2818A 200 MHz (with AutoProbe) Incompatible Incompatible Incompatible Incompatible DP0001A 400 MHz (with AutoProbe) Incompatible Incompatible Incompatible Incompatible N2793A 800 MHz Recommended Recommended Incompatible Recommended N2819A 800 MHz (with AutoProbe) Incompatible Incompatible Incompatible Incompatible N2804A 300 MHz Incompatible Incompatible Incompatible Incompatible N2805A 200 MHz Incompatible Incompatible Incompatible Incompatible N2795A 1 GHz (with AutoProbe) Recommended Recommended Incompatible Recommended N2796A 2 GHz (with AutoProbe) Recommended Recommended Incompatible Recommended N2797A 1.5 GHz (with AutoProbe) Incompatible Incompatible Incompatible Incompatible N7020A 2 GHz Incompatible Incompatible Incompatible Incompatible 01650 -61607 16-channel
N6450-60001 2x8-channel (included in MSO6000A, MSO7000A/B)
1146B 100 kHz Recommended Recommended Recommended Recommended N2780B 2 MHz (use with N2779A) Recommended Recommended Recommended Recommended N2781B 10 MHz (use with N2779A) Recommended Recommended Recommended Recommended N2782B 50 MHz (use with N2779A) Recommended Recommended Recommended Recommended N2783B 100 MHz (use with N2779A) Recommended Recommended Recommended Recommended 1147B 50 MHz (with AutoProbe) Recommended Recommended Incompatible Recommended N2893A 100 MHz (with AutoProbe) Recommended Recommended Incompatible Recommended N7026A 150 MHz (with AutoProbe) Incompatible Incompatible Incompatible Incompatible N2820A 3 MHz/50 µ A high sensitivity,
2 channel (with AutoProbe) N2821A 3 MHz/50 µA high sensitivity,
1 channel (with AutoProbe) N7040A/41A/42A Rogowski coil Recommended Recommended Recommended Recommended
1
Recommended Recommended Recommended Compatible
Compatible Recommended Compatible Recommended
Recommended Compatible Recommended Compatible
Compatible Recommended Incompatible Recommended
Incompatible Incompatible Recommended Recommended
Incompatible Incompatible Incompatible Incompatible
Incompatible Incompatible Incompatible Incompatible
DSO5000A 300 to 500 MHz
MSO/DSO6000A 100 MHz
4
MSO/DSO6000A 300 MHz to 1 GHz MSO/DSO7000A/B 100 MHz to 1 GHz
4
1. The 1130B probe amplifier supports both single- and differential-ended measurements. Higher bandwidth InfiniiMax probe model 1131B, 1132B, and 1134B are also supported by 3000 X-, 4000 X-, 6000 X-, 5000, 6000 300 MHz to 1 GHz models and, 7000 Series.
2. Recommended for InfiniiVision MSOs only.
3. These Infiniium active probes are not supported by InfiniiVision Series scopes – 1152A, 1153A, 1154A, 1155A, 1159A, 1168A/B, 1169A/B, N2800A, N2801A, N2802A, N2803A, N2830A, N2831A, N2832A, N7000A, N70 01A, N7002 A, N7003A, and MX0 023A.
4. MSO/DSO6000A 100-MHz models do not support any Keysight active probes with AutoProbe inter face.
Find us at www.keysight.com
Page 4

Passive Probes

– Designed for optimal performance with your Keysight InfiniiVision Series oscilloscopes – 1:1 and 10:1 attenuation ratio – 20 to 700 MHz
Rugged, high-quality probes at a reasonable price
Keysight 10070-family passive probes are a great choice if you are looking for high quality at a very reasonable price. These general-purpose probes are designed specifically to give you optimal per formance with your InfiniiVision Series oscilloscopes. Ruggedized for general­purpose measurements, they feature a durable cable and a solid stainless steel probe body encased with a hard, fracture-resistant plastic. They are designed and tested to ensure the probes operate in the toughest of conditions
The N28xxA/B low-cost, general-purpose passive probes provide up to 500 MHz bandwidth
and feature a high input resistance of 10 MΩ for low probe loading. These probes provide a
10:1 attenuation ratio except for the N2889A, which provides a switch in the probe handle for switching the attenuation ratio between 1:1 and 10:1. The N284xA and N2853A are the new version of passive probes with improved frequency response over N2862B/63B/90A probes. These probes can be used in place of existing N2862B/63B/90A for better performance. The N2853A is a 10:1 passive probe with 2 m cable length for extended cable connection.
The N2873A/N2894A are 500-MHz/700 MHz 10:1 miniature passive probes that can be used with all InfiniiVision Series. Compact 2.5-mm probe head diameter, low input capacitance, and various fine-pitch probe tip accessories make the N2873A/N2894A passive probes ideal for probing densely populated IC components or surface-mount devices used in today’s high-speed digital applications. The N2894A provides 700 MHz system bandwidth when used
in conjunction with the 4000 X- and 6000 X-Series ≥ 1 GHz models. For more information
about N2870A Series passive probes and accessories, refer to Keysight’s literature number, 5990-3930EN.
The N2140A 200 MHz and N2142A 75 MHz low-cost passive probes are high-impedance probes with switchable attenuation ratio (1:1 and 10:1). These are compatible with the Keysight InfiniiVision EDUX1002A/G and DSOX1102A/G oscilloscopes or similar oscilloscopes with 1 Mohm BNC input.
Find us at www.keysight.com
Page 5
Passive Probes (Continued)
Accessories available for 10070D/73D/74D passive probes
N4848A Probe-tip-to-BNC (m) adapter,
qty 2
50 81-7696 Ground lead with
alligator clip for 1007x and N2862B/63B/89A/90A
N4 847A Retractable hook tip for
1007xC/D (not compatible with 10076A/B), qty 2
N4849A Dual-test lead adapter (for
10070/3/4x), qty 2 50 81-7690 Replacement parts accessory kit 10072 A Fine-pitch probing kit includes
10 SMT clips and 2 dual-lead
adapters 10075 A 0.5 mm IC probing kit.
Contains 4 0.5 mm IC clips and 2
dual-lead adapters
Accessories available for N214 0A /N2142A
N2141A Accessory kit for N2140A
passive probe, 2 sets N2143A Accessory kit for N2142A
passive probe, 2 sets
Accessories available for N2862B/63B/89A/90A and N2840A/41A/42A/43A/53A passive probe
N2856A Accessory kit (containing all
standard accessories)
N2 8 57A Alligator ground lead, qty 1 N2859A Replaceable probe tip N2858A Retractable hook tip, qty 1 N4 827A PCB socket adapter, qty 2 N4826A Dual-lead adapter for, qty 2 N4828A 5 mm ground spring for, qty 2 1250-3978 BNC adapter
Accessories available for N2873A/N2894A (and other N287xA Series passive probes)
N4829A Probe tip kit (rigid and spring loaded), 10 each N4831A Sprung hook adapter 2.5 mm for N2870A/71A/ 72A/73A/75A, N2894A, qty 2 N4 837A Ground lead 15 cm, qty 2 0960-2908 10 self-adhesive copper pads 2x2 N4836A Dual lead-adapter, 2.5 mm, 10 cm, qty 2 0960-2977 Ground lead 11 cm to Miniclip 0960-2978 Ground lead 11 cm to 0.8 mm socket 0960-2979 Rigid probe tips, qty 5 N4838A Ground spring 2.5 mm, qty 2 0960-2981 Spring-loaded probe tip, qty 5 0960-2982 Ground blade 2.5 mm 0960-2983 IC cap 2.5 to 0.5 mm Green 0960-298 4 IC cap 2.5 to 0.65 mm Blue 0960-2985 Insulating cap 2.5 mm 0960-2986 IC cap 2.5 to 1.27 mm Black 0960-2987 IC cap 2.5 to 1.27 mm Black 0960-2988 IC cap 2.5 to 0.8 mm Gray 0960-2989 IC cap 2.5 to 1.0 mm Brown 0960-2990 Adapter 2.5 to 0.8 mm socket N4863A 2.5 mm probe tip-to-PCB adapter, horizontal N4864A 2.5 mm probe tip-to-PCB adapter, vertical
Standard accessories that come with each probe
10070D/10073C/10074C N2862B/63B/89A/90A and
N2840A/41A/42A/43A/53A
Retractable hook tip, qty 1 Retractable hook tip, qty 1 Spring loaded probe tips, qty 2 Colored identification tag, 2 each of 4 colors Ground bayonet, qty 1 Spring ground, qty 1 Ground blade, qty 1 IC insulation cap, qty 1 IC insulation cap, qty 1 Ground spring, qty 1 Adjustment tool, qty 1 Insulation cap, qty 1 Sprung hook, qty 1 Ground lead, qty 1 Adjustment tool, qty 1 (with
BNC adapter, qty 1 Ground lead, qty 1 Copper pads, qty 2
Colored identification tag, 2 each of 4 colors
N2862B/63B), qty 2 (with N2889A/90A)
BNC adapter, qty 1 IC cap to 0.5 mm, 0.65 mm,
Probe tip, qty 1 BNC adapter, qty 1
N2873A /N2894A
Rigid probe tips, qty 2
Ground lead, qty 1
0.8 mm, 1 mm, 1.27 mm, qty 1 each
Insulating cap, qty 1 Protection cap, qty 1 Trimmer tool, qty 1 Color coded rings, 3x4 colors
Find us at www.keysight.com
Page 6
Passive Probes (Continued)
Ordering information for Keysight passive probes
N2142A 10:1/1:1 75 MHz passive probe N2140A 10:1/1:1 200 MHz passive probe 10070D 1:1 20 MHz passive probe N2840A 10:1 50 MHz passive probe N2862B/N2841A 10:1 150 MHz passive probe N2853A 10:1 350 MHz passive probe (2 m cable) 10074D 10:1 150 MHz passive probe N2863B/N2842A 10:1 300 MHz passive probe N2889A 10:1/1:1 350 MHz passive probe 10073D 10:1 500 MHz passive probe N2890A /N2843A 10:1 500 MHz passive probe N2873A 10:1 500 MHz miniature passive probe N2894A 10:1 700 MHz miniature passive probe N7007A 10:1 400 MHz extreme temperature passive probe (2 m cable)
10073D/74D passive probe N2873A/N2894A passive probe with standard
accessories
N2862B/63B/90A passive probe N2889A 10:1/1:1 passive probe N2840A/41A/42A/43A/53A passive probe
Find us at www.keysight.com
N2140A/42A passive probe
Page 7
Passive Probes (Continued)
Characteristics for Keysight passive probes
10070D 10073D 10074D
Bandwidth 20 MHz 500 MHz 150 MHz Risetime (calculated) < 17.5 ns < 700 ps < 2.33 ns Attenuation ratio 1:1 10:1 10:1 Input resistance 1 MΩ 2.2 MΩ 10 MΩ Input capacitance Approx 70 pF Approx 12 pF Approx 15 pF Maximum input (dc + peak ac) 300 Vpk mains isolated 500 Vpk mains isolated 500 Vpk mains isolated
150 Vpk CAT II 400 Vpk CAT II 400 Vpk CAT II Compensation range None 6 to 15 pF 9 to 17 pF Probe readout Yes Yes Yes Cable length 1.5 m 1.5 m 1.5 m
N2862B,41A/ N2863B,42A
Bandwidth 150 MHz /
300 MHz
Risetime (calculated) < 2.33 ns/
< 1.16 ns Attenuation ratio 10:1 1:1/10:1 s witchabl e 10:1 10:1 10:1 10: 1 Input resistance 10 MΩ 10 MΩ (at 10:1)
Input capacitance
Maximum input (dc + peak ac)
Compensation range 5 to 30 pF 5 to 30 pF (at 10:1) 5 to 30 pF 10 to 25 pF 5 to 30 pF 5 to 30 pF Probe readout Yes No Yes Yes Yes No Cable length 1.2 m 1.3 m 1.3 m 1.2 m 2 m 1.2 m
1. 700 MHz BW only available on DSOX /MSOX 4000 X-Series oscilloscopes with 1 GHz or 1.5 GHz bandwidth models.
2. 300 Vrms, 400 V(dc + peak ac) mains isolated; 0 V transient overvoltage with InfiniiVision 6000X.
Bandwiidth 75 MHz at 10:1 200 MHz at 10:1
Risetime (calculated) 4.66 nsec at 10:1 1.75 nsec at 10:1
Attenuation ratio 1:1/ 10:1 swi tchable 1:1/10:1 switchable Input resistance 10 MΩ at 10:1 10 MΩ at 10:1
Input capacitance 15 pF at 10:1 15 pF at 10:1
Maximum input (dc + peak ac) 300 Vrms CAT II at 10:1 300 Vrms CAT II at 10:1
Compensation range 15 pF to 40 pF 15 pF to 40 pF Probe readout No No Cable length 12 0 cm 120 cm
Approx 11 pF Approx 11 pF (at 10:1),
300 V
mains isolated/
CAT II
N2889A N2890A/N2843A N2873A/N2894A N2853A N2840A
350 MHz (at 10:1), 10 MHz (at 1:1) < 1 ns (at 10:1), < 35 ns (at 1:1)
1 MΩ (at 1:1)
60 pF (at 1:1) 300 V mains isolated/ CAT II (at 10:1), 150 V mains isolated/CAT II (at 1:1)
N2142A N2140A
6 MHz at 1:1 6 MHz at 1:1
58.3 nsec at 1:1 58.3 nsec at 1:1
1 MΩ at 1:1 1 MΩ at 1:1
100 pF at 1:1 100 pF at 1:1
150 Vrms CAT II at 1:1 150 Vrms CAT II at 1:1
500 MHz 500 /700 MHz 350 MHz 50 MHz
< 700 ps < 700 ps/
< 500 ps
10 MΩ 10 MΩ 10 MΩ 10 MΩ
Approx 11 pF
300 V mains isolated/ CAT II
Approx 9.5 pF Approx 11 pF
400 V mains isolated2, 300 V CAT II
< 1 ns < 7 ns
Approx 11 pF
300 V mains isolated/ CAT II
300 V mains isolated/ CAT II
Find us at www.keysight.com
Page 8

Extreme Temperature Passive Probe

Features and specifications
– Wide operating temperature range of –40 to +85 °C for extreme temperature
environmental chamber testing – 400 MHz bandwidth (–3 dB) – High impedance (10 MΩ at DC) input – Wide input range: 1 kV CAT II, 600 V CAT III – Includes hook tip adapters (x2), ground leads (x2) and spring ground tip (x1)
The N7007A 400 MHz passive probe is a low-cost, high impedance passive probe with rugged probe tips for environmental chamber testing from –40 to +85 °C. Its large
input impedance (10 MΩ at DC) and wide input voltage range (1,000 Vdc + peak AC
CATII) makes the probe ideal for a broad range of general purpose extreme temperature applications.
Key characteristics
N7007A
Bandwidth 400 MHz (with spring ground), 70 MHz (with ground lead) Attenuation ratio 10:1 Input impedance (at DC) 10 MΩ/15.5 pF (when terminated into 1 MΩ) Oscilloscope compensation range 6 to 18 pF Operating temperature range –40 to +85 °C Operating humidity range < 90% at 40 °C Cable length 2 m Max input range 1 kV CAT II, 600 V CAT III
N7007A Extreme temperature passive probe
Ordering information
N7007A 10:1 400 MHz extreme temperature passive probe N7006A Spring ground for N7007A N7008A Hook tip adapter for N7007A N7009A Ground lead for N7007A
N7006A spring ground
N7008A hook tip adapter
N7009A ground lead
Find us at www.keysight.com
Page 9

High-voltage Passive Probes

– Ideal for measuring up to 3.7 kV – Up to 500 MHz bandwidth – 100:1 attenuation
10076C high-voltage probe
The Keysight 10076C 3.7 kV 100:1 passive probe gives you the voltage and bandwidth you need for making high-voltage measurements. Its compact design makes it easier to probe today’s small power electronics components and its rugged construction means it can withstand rough handling without breaking.
Characteristics 10076C
Bandwidth 500 MHz (–3 dB) Risetime (calculated) < 0.7 ns Attenuation ratio 100:1 Input resistance 66.7 MΩ (when terminated into 1 MΩ) Input capacitance Approx 3 pF Maximum input 3700 Vpk, 2650 Vrms, 2650 Vdc (mains isolated)
1000 Vpk CAT II (post receptacle mains) Compensation 6 to 18 pF range Probe readout Yes Cable length 1.8 m Operating temperature 0 °C to 50 °C
10076C passive probe
N2789A spring ground clip for 10076B/C
Ordering information for Keysight high-voltage probes
10076C High-voltage probe: includes one retractable hook tip, one ground-bayonet, one IC
probing tip, one alligator ground lead, one spring ground tip and a compensation screwdriver
10077A Accessory kit for 10076A/C: includes one retractable
pincher tip, one ground lead, one insulation cap, two measuring pins, and two colored tags
N2789A Spring ground tip for 10076B/C
10077A accessory kit for 10076C
10076C derating curve
Find us at www.keysight.com
Page 10

InfiniiMax Active Probes and Accessories

1130B-34B InfiniiMax high-performance active probe system
– 1.5 to 7 GHz InfiniiMax probe system – InfiniiMax probe amplifier supports
both differential- and single-ended measurements for a more cost­effective solution
– Unrivaled InfiniiMax probing
accessories support browsing, solder-in, and socketed use models at the maximum performance available
– Compatible with 3000 X/ T-,
4000 X-, 6000 X-, 5000, 6000, and 7000 Series oscilloscopes (except for 6000 Series 100-MHz models)
The InfiniiMax 1130B Series probe amplifier is a perfect complement to the InfiniiVision 1 GHz or higher bandwidth models. Its bandwidth, extremely low input capacitance (0.32 pF), high common mode rejection, and patented resistor probe tip technology provide ultra low loading of the DUT and superior signal fidelity. Keysight’s innovative InfiniiMax 1130B Series differential probe is the easiest-to-use, highest performance probing system available for high-speed digital design, and represents a new industry standard for accuracy, flexibility, and reliability. Designers can achieve full system bandwidth in conjunction with InfiniiVision Series oscilloscopes even when manually browsing with the probe or making hands-off measurements.
Optional solder-in probe heads and solder-in sockets, as well as browser configuration provide full bandwidth at the probe tip.
Operating characteristics
Probe bandwidth (–3 dB) 1134B: > 7 GHz
1132B: > 5 GHz 1131B: > 3.5 GHz 1130B: > 1.5 GHz
Rise and fall time (10 to 90%) 1134B: 60 ps
1132B: 86 ps 1131B: 100 ps 1130B: 233 ps
Input capacitance Cm = 0.1 pF Cm is between tips
Cg = 0.34 pF Cg is ground for each tip Cdiff = 0.27 pF differential mode capacitance = Cm + Cg/2 Cse = 0.44 pF single-ended mode capacitance = Cm + Cg
Input resistance Differential mode resistance = 50 kΩ ± 2%
Single-ended mode resistance = 25 kΩ ± 2%
Input dynamic range ± 2.5 V Input common mode range ± 6.75 Vdc to 100 Hz; ± 1.25 V > 100 Hz Maximum signal slew rate 18 V/ns when probing a single-ended signal
30 V/ns when probing a differential signal
DC attenuation 10:1 ± 3% before calibration on oscilloscope
10:1 ± 1% after calibration on oscilloscope
Offset range ± 12.0 V when probing single-ended signal Maximum input voltage 30 Vpeak, mains isolated ESD tolerance > 8 kV from 100 pF, 300 Ω HBM Maximum number of probes supported by 3000 X /T-/ 5000/6000/7000 Series Maximum number of probes supported by 4000 X- and 6000 X-Series
2
4
Find us at www.keysight.com
Keysight 1130B InfiniiMax probe offers you the highest per formance available for measuring differential and single-ended signals
Page 11
InfiniiMax Active Probes and Accessories (Continued)
1130B-34B InfiniiMax high-performance active probe system
Ordering information for Keysight InfiniiMax 1130B Series probe and accessories
Probe amplifier
1130B 1.5 GHz InfiniiMax probe amplifier (order one or more probe heads or connectivity kits per amplifier) 1131B 3.5 GHz InfiniiMax probe amplifier (order one or more probe heads or connectivity kits per amplifier) 1132B 5 GHz InfiniiMax probe amplifier (order one or more probe heads or connectivity kits per amplifier) 1134B 7 GHz InfiniiMax probe amplifier (order one or more probe heads or connectivity kits per amplifier)
Connectivity kits
E2669B InfiniiMax connectivity kit for differential/single-ended measurements E2668B InfiniiMax connectivity kit for single-ended measurements
Individual probe heads
E2675B InfiniiMax differential browser probe head and accessories E2676B InfiniiMax single-ended browser probe head and accessories E2677B InfiniiMax differential solder-in probe head and accessories E2678B InfiniiMax single-ended/differential socketed probe head and accessories E2679B InfiniiMax single-ended socketed probe head and accessories N2851A QuickTip probe head for InfiniiMax I/II probe amp N2849A QuickTip tips for N2851A N5380B InfiniiMax II dif ferential SMA head N5425B/N5426A 12-GHz differential ZIF solder-in probe head and ZIF probe tips N5451A InfiniiMax long-wire ZIF probe tips (for use with N5425B ZIF probe head) N5450B InfiniiMax extreme temperature extension cable (that allows for probing in environments from —55 to +150 °C) N2880A InfiniiMax in-line attenuator kit (pairs of 6 dB, 12 dB and 20 dB attenuator in a kit) N2881A InfiniiMax DC blocking caps (a pair of 30 Vdc blocking cap)
InfiniiMax solder-in probe head with long wires InfiniiMax ZIF tip soldered on board
For more comprehensive information about the 1130B InfiniiMax probe amplifier and its accessories, refer to the Keysight Infiniium Osclloscope Probes, Accessories, and Options data sheet with Keysight literature number 5968-7141EN.
Find us at www.keysight.com
InfiniiMax browser head
Page 12

InfiniiMode Active Probes and Accessories

N2750A-52A InfiniiMode probe
– 1.5 to 6 GHz bandwidth – Dual attenuation ratio (2:1/10:1) – InfiniiMode probing for making
differential, single-ended and common mode measurements with a single probe
– Built-in quick action scope control
for quick access to a variety of scope
functions – Built-in headlight – Includes solder-in, browser, and
socketed tips standard – AutoProbe interface for auto
configuration and probe power
The N2750A Series InfiniiMode differential probe is a new generation of low-cost, differential active probe compatible with InfiniiVision 3000 X-, 4000 X-, 6000 X-Series and Infiniium oscilloscope’s AutoProbe interface.
Measurement versatility
The N2750A Series InfiniiMode probe offer 2:1 and 10:1 dual attenuation settings, allowing them to be used for a broad range of applications. Dual attenuation range is automatically configured depending on the size of the input signal.
This, accompanied with superior signal fidelity, makes these probes useful for most digital design and debug applications. And with their wide dynamic range (10 Vpp) and offset range (± 15 V), these probes can be used in a wide variety of analog signal measurements as well.
InfiniiMode usability
The N2750A comes with new InfiniiMode operation modes. The InfiniiMode allows convenient measurements of differential, single-ended, and common mode signals with a single probe tip without reconnecting the probe to change the connection. The N2750A probe’s InfiniiMode provides the following modes of operation.
– A – B (differential), – A – ground (single-ended A) – B – ground (single-ended B) – (A+B)/2 – ground (common mode)
Quick action scope control
The N2750A Series InfiniiMode probe provides convenient and quick access to various functions on the scope. You often have a need to control the scope while you hold a probe in your hand. With the quick action scope control feature built into the probe, you can turn the built-in headlight of the probe on and off, or control some frequently used scope functions such as RUN/STOP, auto scale, quick print, and quick save with only a button press on the probe. Get control of your most needed function with a push of the quick action control button on the probe.
Flexibility in probe use models is also a vital necessity. The probes come standard with three different types of exchangeable probe tips that allow for easy connections to the circuit under test. These probe tips enable you to access multiple signals on anything from header connectors to hard-to-reach, high-density circuitry. The probes are equipped with a white LED headlight to illuminate the circuit under test which will help you see where you are probing.
This probe is compatible with InfiniiVision 3000 X-Series with software ver. 2.2 or above, 4000 X-Series with software ver.
3.01 or above, and 6000 X-Series with software ver. 6.00.
Ordering information for InfiniiMode probes and accessories
N2750A 1.5 GHz InfiniiMode differential
probe
N2751A 3.5 GHz InfiniiMode dif ferential
probe N2752A 6 GHz InfiniiMode differential probe N2776A Differential browser tips (qty 3) N2777A InfiniiMode solder-in tips (qty 3) N2778A InfiniiMode socketed tips (qty 3) N4822A Socketed tip for USB/Ethernet
application fixtures (qty 1)
Each probe includes two solder-in tips, two socketed tips and two browser tips.
The new dif ferential probe has an input resistance of 200 k (differential) or 100 kΩ (each input to ground), and an extremely low input capacitance of 700 fF to minimize circuit loading.
Find us at www.keysight.com
Page 13
InfiniiMode Active Probes and Accessories (Continued)
Characteristics and specifications for N2750A Series InfiniiMode probes
Model number N2750A N2751A N2752A
Probe bandwidth 1 (–3 dB) 1.5 GH z 3.5 GHz 6 GHz Rise time, probe only (10 to 90%) 233 ps 100 ps 58.3 ps Input resistance (at DC)
Input capacitance 700 fF (with browser) Attenuation ratio (at DC) 2:1 / 10 :1 Input dynamic range ± 1 V, 2 Vpp (at 2:1) / ± 5 V, 10 Vpp (at 10:1) Input common mode range ± 15 V (from DC to 100 Hz), ± 2.5 V (for >100 Hz) Offset range ± 15 V Offset accuracy Maximum non-destructive input voltage ± 30 V (DC + peak AC) Maximum number of probes supported by 3000 X-Series 1 Maximum number of probes supported by 4000 X-, 6000 X-Series
1. Denotes warranted electrical specifications at 2:1 attenuation mode af ter 20 minute warm-up. All others are typical.
2. When calibrated on the oscilloscope, these characteristics are determined by the oscilloscope characteristics.
3. Assumes symmetric differential signals.
1
200 kΩ ± 2% (differential mode) 100 kΩ ± 2% (single-ended mode) 50 kΩ ± 2% (common mode)
3
2
< 3%
4
N2750A with browser tip N2750A with socketed tip N2750A with solder-in tip
For more information about the N2750A Series InfiniiMode probes, refer to the data sheet with the Keysight literature number, 5991-0560EN.
Find us at www.keysight.com
Page 14
High-Voltage Differential Active Probes – DP0001A High-Voltage Differential Probe
– High voltage differential probe for high voltage, high speed power device testing – Measure up to 2 kV mains isolated, 1 kV CAT III and 400 MHz – Unmatched electrical performance - flat frequency response and high CMRR
The DP0001A is a 400 MHz high voltage differential probe with 2 kV mains isolated or 1 kV CAT III rating designed for making accurate high-voltage power measurements required for testing today’s WBG power devices, power converters or motor drives. Thanks to high bandwidth and low loading characteristics, the probe can accurately measure 1 kV transient pulse with as fast as 1.2 nsec of edge speed in modern switching power supplies. Also, high CMRR simplifies the measurement challenges found in noisy, high common­mode power electronics environments.
When used with an InfiniiVision oscilloscope, the probe provides four manually switchable modes of attenuation to make low noise measurement at high V/div settings. The
differential probes have a differential input resistance of 10 MΩ and low input capacitance
of 2 pF to minimize circuit loading. The DP0001A is compatible with Keysight oscilloscopes
with a 50-Ω AutoProbe interface, which configures the scope for the probe automatically.
When probing differential signals inside of environmental chambers at extreme temperatures, Keysight offers the N7013A extreme temperature extension kit. The N7013A is compatible with the DP0001A with a de-rated bandwidth of 70 MHz. The 70 cm long differential cable set and accessories can operate in temperatures ranging from -40 degC to +85 degC.
The probe is compatible with InfiniiVision 3000TX, 4000X and 6000X models.
Frequency response of DP0001A
Find us at www.keysight.com
Page 15
DP0001A characteristics and specifications
Characteristic
Probe bandwidth (-3 dB)
Risetime (10% - 90%)
Input voltage 50 V 1.2 nse c 1.2 nse c 875 psec 875 psec Input voltage 500 V Not Applicable Not Applicable 1.2 ns ec 1.2 nsec Input voltage 1000 V Not Applicable Not Applicable Not Applicable 1.2 nsec
Maximum rated input voltage
Mains isolated *
CAT III
Noise (Vrms ‡ / spectral density)
(Referred to the input)
Typical propagation delay 10 ns Maximum differential input voltage (DC + AC peak) Common mode voltage ± 2000 Vpk (1400 Vrms) DC gain accuracy ± 0.7 % ± 0.7 % ± 0.35 % ± 0.35 % Offset drif t ** 150 μV / °C 150 μV / °C 40 μV / °C 40 μV / °C
Input impedance
Each input to ground 5 MΩ || 4pF Differential Input Impedance 10 MΩ || 2pF
Input coupling of the oscilloscope Typical CMRR (dB) DC > 80 > 80 > 80 > 80
Standard accessories Spring tips (qty 4), contact pins (qty 10), probe tip adapters (qty 2), safety alligator clips (qty 2),
Max number of probes supported 1 (with 3000TX), 4 (with 4000X and 6000X)
††
100 kHz 75 70 65 60 1 MHz 75 70 65 60 10 MHz 70 58 54 32 100 MHz 45 40 35 32
50:1 100:1 250:1 500:1
400 MHz 400 MHz 400 MHz 400 MHz
180 mV / 9 μV/rt (Hz) 180 mV / 9 μV/rt (Hz) 280 mV / 14 μV/rt (Hz) 300 mV / 15 μV/rt (Hz)
± 200 V ± 400 V ± 1000 V ± 2000 V
alligator plunger clips (qty 2), spade terminals (qty 2), pincer clips (qty 2), hook tip adapters (qty 2),
Value measured at the four supported attenuation modes
2000 Vrms
6000 V Overvoltage Transient
1000V
AutoProbe Interface 50 Ω
coupler f-f (qty 1)
* Mains isolated is for measurements performed on circuits not directly connected to a mains supply. † Measurement category III is for measurements performed in the building installation. ‡ Broadband Noise, Bandwidth 400 MHz. ** Referred to the output of the probe. †† Must be met to achieve the best performance and to avoid damage to the probe. ‡‡ DC gain and bandwidth are the only warranted specifications. All others are typical.
Ordering information
Model number Description
DP0001A 400 MHz high voltage differential probe DP0002A Accessory kit for DP0001A N7013A Extreme temperature probing kit for differential probe, probe BW derated to < 70 MHz with the
extension cable used
Find us at www.keysight.com
Page 16

High-voltage Differential Active Probes

– 25 to 800 MHz bandwidth – High common mode rejection ratio – Measure up to 1,400 V CAT II and 7 kV mains isolated
N2790A/91A and N2891A high voltage differential probes
Oscilloscope users often need to make floating measurements where neither point of the measurement is at earth ground. Use N2790A, N2791A, or N2891A high voltage differential probes to make safe and accurate floating measurements with an oscilloscope. The N2790A, N2791A, and N2891A high voltage differential probes allow conventional earth-grounded Keysight oscilloscopes to be used for floating signal measurements.
Each probe offers user-selectable attenuation settings that makes it highly versatile, allowing it to be used for a broad range of applications. The probe comes with probe tip accessories for use with small and large components in tight spaces.
The N2791A and N2891A are compatible with any oscilloscope with 1 M BNC input. The N2791A and N2891A probe power is supplied by included 4x AA batteries or USB host port of the scope or PC via a supplied USB power cable. The N2790A is compatible with the Keysight’s AutoProbe interface where the probe power is supplied by the Keysight oscilloscope’s probe interface.
N2790A N2791A N2891A
Bandwidth 100 MHz 25 MHz 70 MHz Risetime 3.5 ns 14 ns 5 ns Attenuation ratio 50:1 / 500:1 10:1 / 100:1 100:1 / 1000:1 CMRR —80 dB at 50/60 Hz —80 dB at 50/60 Hz –80 dB at 50/60 Hz
—50 dB at 1 kHz —40 dB at 1 MHz –60 dB at 20 kHz
—50 dB at 1 MHz Input impedance (between inputs) Max input voltage to ground Max input voltage between two inputs Max number of probes supported by 3000 X-/4000 X-/6000 X-/ 5000/6000/7000 Series
8 MΩ / 3.5 pF 8 MΩ / 8 pF 100 MΩ / 5 pF
± 1000 V (CAT II) ± 700 V at 100:1 ± 7000 V at 1000:1
± 600 V (CAT III) ± 70 V at 10:1 ± 700 V at 100:1
± 1400 V at 500:1 ± 700 V at 100:1 ± 7000 V at 1000:1
± 140 V at 50:1 ± 70 V at 10:1 ± 700 V at 100:1
4 4 4
Find us at www.keysight.com
Page 17
High-voltage Differential Active Probes (Continued)
N7013A extreme temperature extension cable kit
The N7013A is a 70-cm long extreme temperature extension cable kit compatible with four of Keysight’s medium- and high-voltage differential active probes, including the DP0001A, N2790A, N2791A, N2792A, and N2818A. These probes are typically used in power supply testing applications, as well as testing automotive differential buses including CAN, CAN FD, and FlexRay. With the N7013A extension kit, the main body of the temperature-sensitive differential active probe can be placed outside of the environmental chamber, while the extension kit (70-cm long cable pair) and connection adapters can be extended into the environmental chamber under extreme-temperature conditions ranging from -40 to +85 °C.
The N7013A kit includes:
– 1 pair of extreme-temperature differential extension cables – 1 pair of extreme-temperature hook tip adapters – 1 pair of extreme-temperature banana-to-socketed tip adapters for connecting to
0.025” square pins
The N7014A accessory includes: 1 pair of banana-to-socketed tip adapters
Key characteristics
Temperature range —40 to +85 °C Cable length 70 cm Derated bandwidth DP0001A, N2818A, N2792A, N2790A 70 MHz Derated bandwidth with N2791A 25 MHz
N7013A Extreme Temperature Probing Kit
N7014A Banana-to-socketed tip adapter
Find us at www.keysight.com
Page 18
High-voltage Differential Active Probes (Continued)
N2804A/N2805A high-voltage, high-speed differential probes
The N2804A and N2805A differential probes provide the superior general-purpose differential signal measurements that are required for high-speed power measurements such as measuring characteristics of switching power devices, DC-DC converters or class D amplifiers, vehicle bus measurements, and high-speed digital system designs.
The N2804A 300-MHz differential probe offers 100:1 attenuation ratio, allowing it to be used adequately for high voltage signal measurements. The differential probe has a differential input resistance of 4 M and low input capacitance of 4 pF to minimize circuit loading. The probe comes with a pair of extension leads (30 cm long) with a damping resistor built-in to damp out the in-band resonance and provide flat frequency response even while using the extension leads and probe tip accessories.
The N2805A is a 200-MHz differential probe designed to provide superior differential signal measurements with a long cable length (5 m), making it ideal in an environment where extended cable length is required. This probe comes with an extensive set of probe tip accessories for use with small and large components in tight spaces.
Characteristics for N2804A and N2805A
N2804A N2805A
Bandwidth 300 MHz (without extension leads) 200 MHz
120 MHz (with extension leads) Attenuation ratio 100:1 50:1 CMRR —80 dB at 50/60 Hz —75 dB at 50/60 Hz
—75 dB at 1 MHz —80 dB at 1 MHz Input impedance (between inputs) Max input voltage (between two inputs) Max input voltage ± 300 V (DC+ peak AC) and
Cable length 1.2 m 5 m Max number of probes supported by InfiniiVision Series Compatible InfiniiVision oscilloscopes
4 MΩ // 4 pF 4 MΩ // 4 pF
± 300 V (DC+ peak AC) and
± 200 Vrms
± 200 Vrms CATII
± 1000 V (DC+ peak AC) and
± 1000 Vrms CATI
4 4
6000X Series, 4000X Series with software ver. 4.0 or higher, 3000X
Series with software ver. 2.38 or higher
± 200 V (DC+ peak AC) and ± 200 Vrms CAT II ± 500 V (DC+ peak AC) and ± 500 Vrms mains isolated ± 300 V (DC+ peak AC) and ± 200 Vrms CATII
N2804A 300 MHz differential probe
For more information about the N7020A power rail probe, refer to the Keysight data sheet with the publication number 5992-0141EN.
Find us at www.keysight.com
N2805A 200 MHz dif ferential probe
Page 19
High-voltage Differential Active Probes (Continued)
N2792A/N2818A 200-MHz and N2793A/N2819A 800-MHz general-purpose differential probe
The N2792A/N2818A 200-MHz and N2793A/N2819A 800-MHz differential probes provide the superior general-purpose dif ferential signal measurements required for today’s high-speed power measurements, vehicle bus measurements, and digital system designs.
The N2792A/N2818A and N2793A/N2819A probes offer a 10:1 attenuation setting, high input resistance, and low input capacitance to minimize circuit loading.
The N2792A/93A are compatible with any oscilloscope with 50 Ω BNC input. The
probe can be powered by any USB port on a scope or computer, or by a 9 V battery. The N2818A/19A are the AutoProbe interface versions of the N2792A/93A. They are compatible with the InfiniiVision 3000 X-, 4000 X- and 6000 X-Series only.
Characteristics for N2792A/N2818A and N2793A/N2819A differential probes
N2792A/N2818A N2793A/N2819A
Bandwidth 200 MHz 800 MHz Risetime 1.75 ns 437 ps Attenuation ratio 10:1 10:1 CMRR —80 dB at 50/60 Hz
—50 dB at 10 MHz Input impedance (between inputs) 1 MΩ // 3.5 pF 200 kΩ // 1 pF Max input voltage to ground ± 60 V ± 40 V Max input voltage between two inputs ± 20 V ± 15 V Max number of probes supported by InfiniiVision Series
4 4
—60 dB at 50/60 Hz —15 dB at 500 MHz
Ordering information for Keysight high voltage differential probes, power supplies and accessories
N2790A 100-MHz, 1.4 kV differential probe with AutoProbe interface N2791A 25-MHz, 700-V differential probe N2792A 200-MHz, 20-V differential probe N2818A 200-MHz, 20-V differential probe with AutoProbe interface DP0001A 400-MHz, 2,000 V differential probe with AutoProbe interface N2793A 800-MHz, 15-V differential probe N2819A 800-MHz, 15-V differential probe with AutoProbe interface N2891A 70-MHz, 7,000-V differential probe N4853A Variable pitch browser for N2793A/N2819A, qty 2 N4854A DC blocking capacitor for N2793A/N2819A, qty 2 N2804A 300 MHz high voltage differential probe N2805A 200 MHz high voltage differential probe with extended cable length N2816A Probe tip accessory kit for N2804A including 2 alligator clips, 2 pincer clips, and
2 extension leads (30 cm)
N2817A Probe tip accessory kit for N2805A including 2 alligator clips, 2 hook clips, 2 pincer
clips, and 2 browser tips DP0002A Probe tip accessory kit for DP0001A N7013A Extreme temperature extension cable kit for N2790A, N2791A, N2792A, and N2818A
N2790A 100-MHz, 1.4-kV differential probe with AutoProbe interface
N2791A 25-MHz, 700-V dif ferential probe
N2792A 200-MHz, 20-V differential probe
N2793A 800-MHz, 15-V differential probe
Find us at www.keysight.com
Page 20

Single-ended Active Probes

N2795A/96A/97A low-cost single-ended active voltage
High resistance (1 MΩ) and low
capacitance (1 pF) input for low loading
– Wide input dynamic range (± 8 V) and
offset range (± 12 V for N2796A/97A,
± 8 V for N2795A) – Built-in headlight – Direct connection to AutoProbe
interface (no power supply required) – N2797A for extreme temperature
environmental chamber testing at
–40 to +85 °C
The N2795A/96A are a new generation of low-cost, 1 to 2 GHz single-ended active probes with the AutoProbe interface (compatible with Keysight’s InfiniiVision and Infiniium family of oscilloscopes). These probes integrate many of the characteristics needed for today’s general­purpose, high-speed probing–especially in digital system design, component design/ characterization, and educational research applications. Its 1 M input resistance and extremely low input capacitance (1 pF) provide ultra low loading of the DUT. This, accompanied with superior signal fidelity, makes these probes useful for most of today’s digital logic voltages. Testing devices over extreme temperature ranges is quite common these days. The N2797A 1.5 GHz single-ended active probe is the industry’s first low-cost high input impedance active probe with rugged probe tips for environmental chamber testing of ICs and devices. It gives the ability to probe signals at drastic temperature swings ranging from –40 to +85 °C. The probe provides a 2 m long cable. Order N2798A for re-ordering accessories.
The N2795A/96A/97A are equipped with a white LED headlight to illuminate the circuit under test. The probes are powered directly by the InfiniiVision and Infiniium Autoprobe inter face, eliminating the need for an additional power supply. The probes also come with a number of accessories that allow for easy connections to the circuit under test.
Model number N2795A N2796A N2797A
Probe bandwidth 1 (–3 dB) 1 GHz 2 GHz 1.5 GHz Risetime 350 ps 175 ps 233 psec
System bandwidth 500/600 MHz with
Keysight’s 500/600 MHz InfiniiVision/ Infiniium, 1 GHz with 1 GHz
1 GHz with Keysight’s 1 GHz InfiniiVision/Infiniium, 1.5 GHz with Keysight’s 1.5 GHz InfiniiVision 4000 X, 6000 X
InfiniiVision 3000 X, 4000 X Attenuation ratio (at dc) Input dynamic range
10:1 ± 0.5%
–8 to +8 V (DC or peak AC) Non-destructive input voltage –20 to +20 V Offset range ± 8 V ± 12 V DC offset error (output zero) ± 1 mV Low frequency accuracy 0.5% at 70 Hz, 1 Vpp Input resistance
1
1 MΩ
Input capacitance 1 pF Output impedance 50 Ω
Max number of probes supported by InfiniiVision 3000 X-/5000/6000/7000 Series
Max number of probes
2
2
4 supported by InfiniiVision 4000X, 6000X
1. Denotes warranted electrical specifications after 20 minute warm-up, all others are t ypical.
2. The N2797A is compatible with 3000 X/ T-, 4000 X- and 6000 X-Series only.
Replacement accessories
N4839A Dual lead socketed adapter, 6 cm, qty 2 N4840A Dual lead solder-in adapter, 5 cm, qty 2 N4 8 41A Dual lead socketed adapter, 9 cm, qty 2
N4842A Dual pin PCB header, qty 2 N4843A Solderable tips, qty 10
N4844A Right angle ground lead, 5 cm, qty 2 N4845A Ground blade, qty 2 N4846A Offset ground, qty 2
For more information about N2795A/96A/97A active probe, refer to the Keysight N2795A/96A/97A active probe data sheet, literature number 5990-6480EN
Find us at www.keysight.com
Page 21
Single-ended Active Probes (Continued)
N7020A power rail probe
– 2-GHz single-ended active probe for power rail noise measurement – 1.1:1 attenuation ratio ensures low noise signal measurement – ± 24 V of probe offset range enables effective elimination of DC component of a
power supply.
The N7020A power rail probe is a low noise, large offset range oscilloscope probe that enables users to measure small signals riding on top of DC power rails.
– Low noise: The N7020A power rail probe is a 1:1 attenuation ratio active probe. As
a general rule, the higher a probes attenuation ratio, the nosier the signal will be on the oscilloscope.
– Large offset range: The N7020A power rail probe provides ± 24 V of probe offset.
This enables users to center the signal on screen while placing the oscilloscope at its maximum vertical sensitivity and zoom in on the signal.
Low DC loading: The N7020A power rail probe has 50 kΩ input impedance at DC,
minimizing the probe’s DC loading of the power rail.
– Large input dynamic range: The N7020A power rail probe’s ± 850 mV input dynamic
range means that users can measure up to ± 850 mV deviations of their DC supplies. This is very useful for measuring programmable supplies like those used in microcontroller power saving modes.
– Supporting three connection options — pigtail solder head (2 GHz), SMA (2 GHz),
and browser (350 MHz).
N7020A power rail probe
Characteristics and specifications
Probe bandwidth (—3 dB) 2 GHz Attenuation ratio 1.1:1 Offset range ± 24 V Input impedance at DC 50 kΩ at > 1 MHz 50 Ω Input dynamic range ± 850 mV Probe noise 10% of oscilloscope noise Included accessories N7021A coaxial probe head (qty. 3), N7022A SMA main cable,
N7023A browser kit Max number of probes supported by InfiniiVision Compatible InfiniiVision oscilloscopes
For more information about the N7020A power rail probe, refer to the Keysight data sheet with the publication number 5992-0141EN.
4
3000X/T-Series with sof tware ver. 2.38 or higher
4000 X-Series with software rev. 4.0 or higher
6000 X-Series with software rev. 6.10 or higher
N7023A browser kit (now included in the N7020A or orderable separately)
Find us at www.keysight.com
Page 22

Mixed Signal Oscilloscope Logic Probes

– Compatible with all 40-pin logic
probes
– Flying leads offer flexibility and
convenience
MSO probes offer great value and performance
These logic probes for the InfiniiVision mixed signal oscilloscopes (MSOs) are the same ones used with Keysight industry- leading high-performance logic analyzers. This means we can offer the best performance, great value, and access to the industry’s broadest range of logic probing accessories.
The N2756A 4 x 4 signal logic probes are divided into four sets of four channels so you can probe pins that are far apart and work conveniently with only one set if that’s all you require. For optimal signal fidelity, connect ground at each logic probe, in addition to taking a common ground to all four signals via a separate ground connector on the probe pod. The N2756A probe is included with 3000, 4000, and 6000 X-Series MSOs.
Characteristics for Keysight 54620-68701, N6450-60001, N6459-60001 logic probes
Input impedance 100 kΩ Input capacitance 8 pF
The 01650-61607 is the 40-pin (F) to 40-pin (F) logic probe cable for Keysight’s InfiniiVision and 54600 Series MSOs. This cable gives the MSO the standard 40-pin female input connector that many Keysight logic analyzers have. With this cable, a user can connect a wide variety of logic analyzer probes such as Mictor, Samtec, and Soft Touch probes. Please note that the 01650-61607 logic probe cable is no longer available for purchase. Without the 01650-61607, 40-pin to 40-pin cable, 40-pin Mictor, Samtec or Soft Touch probes you may already own cannot be used with InfiniiVision MSOs.
Characteristics for Keysight 01650-61607 logic probe
Input impedance 100 kΩ Input capacitance 12 pF
Ordering information for Keysight logic probes
N2756A 16 ch 4 x 4 MSO cable kit
for 3000, 4000, and 6000 X Series MSO. Includes 18 grabbers, 5 right angle grounds, and 5 ground extension leads
N2755A 8 ch 2 x 4 MSO cable kit
for 2000 X Series MSO. Includes 9 grabbers, 3 right angle grounds, and 3 ground extension leads
01650-61607 40-pin (F) to 40-pin (F) logic
probe cable
The N2755A is an 8-channel MSO logic probe designed to work with the 2000 X-Series MSOs.
N2756A 16-ch MSO cable kit
01650- 61607 logic probe
N2755A 8-ch MSO cable kit
Find us at www.keysight.com
Page 23
Mixed Signal Oscilloscope Logic Probes (Continued)
The InfiniiVision MSO digital channels were designed to be compatible with a wide variety of probing accessories developed over 20 years for logic analyzers. There is a good chance that the logic analyzer accessories you already own work with your MSO. With the addition of an optional 40-pin cable, 01650-61607, the MSO accepts numerous logic analyzer accessories:
– E5346A 34-channel Mictor connector probe – E5385A 34-channel Samtec connector – E5383A 16-channel flying lead set – 01650-63203 16-channel termination adaptor (also available as a bundle of both
the termination adapter and the 40-pin cable with PN 10085-68701) – E5404A 34-channel soft touch pro connectorless probe – E5394A 34-channel soft touch connectorless probe – E5396A 16-channel soft touch connectorless probe – Any other accessory that connects to a logic analyzer via a 40-pin cable
For logic accessories of greater channel width than MSO digital channels (> 16 channels), there are two use models.
– Route up to 16 signals to the probe and do not use the additional probe channels. – Route up to 32 signals to the probe and measure half of them at a time. Simply plug
the 40-pin cable to the other side of the probe to see the other half of the signals.
E5346A 34-channel Mictor connector probe E5385A 34-channel Samtec connector probe
E5396A 16-channel soft touch connectorless probe
Find us at www.keysight.com
Page 24

Clamp-on Current Probes

– Up to 150 MHz bandwidth and
500 Arms current measurement range – Hybrid technology to measure ac and
dc – Compatible with 1 MΩ scope input
Accurate current measurements without breaking the circuit
Compatible with any scope or voltage measuring instruments with BNC input, the 1146B and N2780B Series current probes offer accurate and reliable solutions for measuring dc and ac currents. The probes use a hybrid technology that includes a Hall effect sensor that senses the dc current, and a current transformer that senses the ac current, making it unnecessary to make an electrical connection to the circuit.
1146B 100 kHz current probe
The 1146B ac/dc current probe provides accurate display and measurement of currents from 100 mA to 100 Arms, dc to 100 kHz, without breaking into the circuit. A battery level indicator and overload indicator help ensure proper readings. It connects directly to the scope through a 2-m coaxial cable with an insulated BNC.
1147B/N2893A/N7026A 50-MHz/100-MHz/150-MHz current probe with AutoProbe interface
The 1147B/N2893A/N7026A have wide bandwidth ranges, from DC to 50-MHz/100-MHz/150-MHz. The probes offer flat frequency response across the entire bandwidth range, low noise (2.5 mArms for 1147B/N2893A, 250 µArms for N7026A) and low circuit insertion loss.
These three current probes are compatible with the AutoProbe interface, which completely configures the oscilloscope for the probe. AutoProbe can be found on the InfiniiVision 3000T X-, 4000 X-, and 6000 X-Series. Probe power is provided by the scope. The N2893A and N7026A uniquely provide auto demagnetization and offset elimination feature when used in conjunction with InfiniiVision or Infiniium oscilloscopes.
N2780B/81B/82B/83B/83L 2-MHz/10-MHz/50-MHz/100­MHz current probes
The N2780B Series current probes are high bandwidth, active current probes, featuring flat bandwidth, low noise (2.5 mArms) and low circuit insertion loss. In conjunction with the power supply (model N2779A), these probes can be used with any oscilloscope having a high­impedance BNC input. The companion power supply N2779A (3 x 12 Vdc output) lets you connect up to any three N2780B­83B current probes to a single power supply.
The N2783L 80 MHz current probe offers a 5-m long cable, which allows you to reach DUTs over long distances very easily. Other than the bandwidth performance, the N2783A and N2783L have the same electrical performance. The N2783L also requires the N2779A power supply to power the probe. The N2779A is UL listed.
1147B 50-MHz current probe with AutoProbe interface
1146B 100-kHz current probe
Find us at www.keysight.com
N2893A 100-MHz current probe with AutoProbe interface
N2780B Series current probes with N2779A power supply
N7026A 150-MHz high sensitivity current probe with AutoProbe interface
Page 25
Clamp-on Current Probes (Continued)
N7026A high sensitivity clamp­on current probe
1 mA/div sensitivity
The N7026A is the Keysight’s highest sensitivity clamp-on current probe. It has up to 5x lower noise than our other clamp-on current probes with 0.1V/A output voltage rate. This enables you to measure down to 1 mA/div with much higher accuracy. The N7026A, when used with an InfiniiVision or Infiniium oscilloscope, provides highly-accurate, low current waveforms for improved debug and analysis.
Wide input range
It also has a wide input range, up to 30 Arms or 40 Apk. To achieve the widest input range, you must use the external AC power adapter that comes with the probe. Without the external power adapter, you can achieve up to a 5 Arms or 5 Apeak input range. The oscilloscope will automatically synchronize with the corresponding power source when inserting or removing the AC adapter. In either case, a degauss operation will oc c ur.
Improved noise floor of the N7026A (yellow trace) over the N2893A (green trace)
Degaussing made easy
For accurate measurement with a clamp-on current probe, degaussing and eliminating the offset error is critical. A degauss button is included in the design of this probe. One push of the button will perform a degauss operation. Pushing and holding the button for > 2 sec will perform a degauss and autozero the DC of fset. Whenever you are using the degauss button, the current sensor should be locked with no current flowing. Alternatively, the same operation can be performed from the oscilloscope GUI.
Find us at www.keysight.com
N7026A current probe
Page 26
Clamp-on Current Probes (Continued)
Characteristics of the 1146B current probe
Bandwidth Current range
Output signal 1000 mV peak max
AC current accuracy Range 100 mV/A
Accuracy Range
Accuracy Range
Accuracy (40 A to 100 A peak)
Noise Range 10 mV/A:
Insertion impedance 0.01 Ω (50/60 Hz) Maximum working voltage Maximum common mode voltage Influence of adjacent conductor Influence of conductor position Battery 9 V alkaline (NEDA
Low battery Green LED on when
Battery life 55 hours typical
1
dc to 100 kHz (–3 dB)
1
100 mV/A:100 mA to 10 A peak 10 mV/A:1 to 100 A peak
1
(50 mA to 10 A peak)
3% of reading ± 50 mA
10 mV/A (500 mA to 40 A peak)
4% of reading ± 50 mA
10 mV/A (40 A to 100 A peak)
15% max at 100 A
480 μV
Range 100 mV/A: 3 mV
600 Vrms CAT II or 300 Vrms CAT III 600 Vrms CAT II or 300 Vrms CAT III < 0.2 mA/A AC
< 0.2 mA/A AC
1604A, IEC 6LR61)
≤ 6.5 V
Characteristics of N2780B Series current probes
Bandwidth (–3 dB) dc to 2 MHz (N2780B)
dc to 10 MHz (N2781B) dc to 50 MHz (N2782B) dc to 80 MHz (N2783L) dc to 100 MHz
(N2783A) Maximum current (continuous)
Maximum peak current (non­continuous)
Maximum input voltage
Output voltage rate 0.01 V/A (N2780B/81B)
Amplitude accuracy ± 1.0 % rdg ± 500 mA
500 A (N2780B)
150 A (N2781B)
30 A
(N2782B/83B/83L)
700 A peak (N2780B)
300 A peak (N2781B)
50 A peak
(N2782B/83B/83L)
300 V mains isolated
(N2782B/83B/83L)
300 V CAT III, 600 V
CAT II (N2780B/81B)
0.1 V/A
(N2782B/83B/83L)
(N2780B)
± 1.0 % rdg ± 100 mA
(N2781B)
± 1.0 % rdg ± 10 mA
(N2782B)
± 1.0 % rdg ± 10 mA
(N2783B/83L)
Ordering information for Keysight current probes
1146B 100-kHz current probe 1147B 50-MHz current probe with
AutoProbe interface
N2893A 100-MHz current probe with
AutoProbe interface
N7026A 150-MHz high sensitivity current
probe with AutoProbe interface N2780B 2-MHz current probe N2781B 10-MHz current probe N2782B 50-MHz current probe N2783L 80-MHz current probe with
5-m long cable N2783B 100-MHz current probe N2779A 3-channel power supply for
N2780B/81B/82B/83B/83L
For more information about the N2780B Series current probes, refer to the Keysight N2780B Series current probe data sheet, literature number 5989-6432EN.
Note: Reference conditions 23 ± 5 °C, (73.4 ± 41 °C) 20 to 75% relative humidit y, dc to 1 kHz, probe zeroed, 1-minute warmup, batteries at 9 V + 0.1 V, external magnetic field < 4 0 A/m, no dc component, no external current carrying
conductor, 1 MΩ/100 pF load, conductor
centered in jaw.
1. Characteristics marked with asterisks are specified performance. Others are typical characteristics.
Find us at www.keysight.com
Page 27
Clamp-on Current Probes (Continued)
Characteristics of the 1147B/N2893A/N7026A current probes
1147B/N2893A N7026A
Bandwidth (–3 dB) DC to 50 MHz (1147B) DC to 150 MHz
DC to 100 MHz (N2893A) Rise time (calculated, 10% to 90%) 7 nsec (Tr = 0.35/BW) 2.67 nsec (Tr = 0.4/BW) Maximum current (continuous) 15 Apeak, 15 ADC, 10 Arms 30 ADC, 30 Arms (with external power adapter)
30 Apeak, 30 ADC, 24 Arms (when one
probe is used with InfiniiVision 3000XT,
5000/6000/7000 scope) Maximum peak current (non-continuous) (for
pulse-widths ≤ 10 µs)
Output voltage rate 0.1 V/A 1 V/A and 0.2 V/A, automatically switched by the
Minimum oscilloscope vertical scale 10 mA/div 1 mA/div Amplitude accuracy ± 1% rdg, ± 10 mA (DC or 45 to 66 Hz, rated
Noise ≤ 2.5 mArms (for 20 MHz bandwidth measuring
Temperature coefficient for sensitivity ± 2% or less (within a range of 0 to 40 °C or 32 to 104 °F) Effect of external magnetic fields Equivalent to a maximum of 20 mA (in a DC to 60 Hz, 400 A/m magnetic field) Maximum rated power 3 VA (with rated current) Maximum input voltage 300 V mains isolated Diameter of measurable conductors 5 mm dia. (0.2 in dia.) Probe interface AutoProbe interface (1 MΩ terminated) Cable lengths Appox. 1.5 m (59.0 in) Maximum number of probes supported 2 (3000XT, 5000/6000/7000) 2 (3000XT, 5000/6000/7000 without external
30 Apeak 40 Apeak (when using external AC power adapter)
32 Apeak (when one probe is used with
InfiniiVision 3000XT, 5000/6000/7000 scope)
current)
instrument)
4 (4000X, 6000X) 4 (3000XT, 5000/6000/7000 with external power
5 ADC, 5 Arms (without external power adapter)
15 Apeak (without using external power adapter)
oscilloscope
± 1% rdg. ± 5 mA to 30 Arms (including calibration
scale factor of oscilloscope measured at DC or 45 to 66 Hz)
≤ 250 µArms (for 20 MHz bandwidth measuring
instrument)
power adapter)
adapter) 4 (4000X, 6000X)
Find us at www.keysight.com
Page 28

N7040A/41A/42A Rogowski Coil AC Current Probes

– Easy-to-use clip-around coil enabling current measurement in confined space – Measure AC current up to 3,000 Apk (with N7040A) – Up to 30 MHz bandwidth (with N7041A/42A)
The N7040A Series Rogowski coil current probes are designed for measuring AC currents ranging from a few 100 milliamps to 3,000 A from 3 Hz to > 30 MHz.
The probes have a thin, lightweight, flexible and simple-to-use clip-around Rogowski coil that enables current measurement in the most difficult-to-reach parts and confined spaces of a circuit under test and can measure large AC current without increase in transducer size.
The N7040A Series is ideal for measuring AC current in the presence of large DC current and can be used to design, debug and troubleshoot power semiconductor circuits, power supplies, inverters and motor drives.
These probes come with an AC power adapter and 4x AA batteries to power the probe and can be used with any oscilloscope with 1 Mohm BNC interface.
N7040A N7041A N7042A
HF bandwidth (—3 dB) 23 MHz 30 MHz 30 MHz LF bandwidth (—3 dB) 3 Hz 12 Hz 9.2 Hz Peak current (Apk) 3,000 Apk 600 Apk 300 Apk Sensitivity 2 mV/A (500:1) 10 mV/A (100:1) 20 mV/A (50:1) Max noise (mVpp) 8 mVpp 10 mVpp 15 mVpp Droop (%/msec) 2.8%/msec 11%/ms e c 9%/msec Peak di/dt (kA/usec) 80 kA/µsec 40 kA/µsec 20 kA/µsec Absolute max peak di/dt (kA/µsec) 100 k A/µsec 100 kA /µsec 70 kA/µsec Absolute max rms di/dt (kA /µsec) 1. 2 kA /µsec 1.2 k A/µse c 1.2 k A /µsec Accuracy Calibrated to ± 0.2% of reading with conductor central in the coil loop Variation in conductor position ± 2% of reading Linearity 0.05% of reading DC offset ± 3 mV max at 25 ºC Temperature range Coil and cable at —40 to +125 ºC Coil voltage 5 kV peak 5 kV peak 1.2 kV peak Coil length (circumference) 200 mm 100 mm 80 mm Coil cross-section (diameter) 4.5 mm 4.5 mm 1.7 mm Cable length 4 m (connecting cable coil to
integrator box)
Total cable length 4.5 m (4 m input cable + 0.5 m BNC
cable to scope) Probe output Terminated into 1 MΩ BNC input of oscilloscope Probe power 4x AA batteries and AC power adapter (included)
2.5 m (connecting cable coil to integrator box)
3 m (2.5 m input cable + 0.5 m BNC cable to scope)
Find us at www.keysight.com
Page 29

High-sensitivity Current Probes

– Measure AC/DC currents as low as
50 µA
– Ideal for capturing and analyzing
low level current flow in the DUT to characterize sub-circuits or measure current consumption of battery­powered devices or integrated circuits
– Simultaneous high- and low-gain
views of the current waveform for more precise wide dynamic range measurement (with N2820A)
As modern battery-powered devices and integrated circuits become more green and energy efficient, there is a growing need to make high-sensitivity, low-level current measurements to ensure the current consumption of these devices is in acceptable limits. The N2820A high-sensitivity probe is engineered to make high-dynamic-range, high­sensitivity measurements to meet today’s challenging current measurement needs.
Use an area-under-the-curve measurement (Charge) on InfiniiVision oscilloscopes to easily calculate the integrated current consumptions over time in Ah.
The N2820A/21A high-sensitivity current probes are compatible with InfiniiVision 3000 X-, 4000 X- and 6000 X-Series oscilloscopes.
The ultra-sensitive N2820A AC/DC current probe can support measurements from 50 µ A to 5 A on Keysight oscilloscopes. The N2820A interface uses a make-before-break (MBB) connector, allowing you to quickly probe multiple locations on your DUT without having to solder or unsolder the leads. The N2820A 2-channel current probe connects to two oscilloscope channels to provide simultaneous low-and high-gain views for wider dynamic range measurement, while the N2821A 1-channel current probe provides one user-selectable view at a time.
The N2820A 2-channel current probe connects to two oscilloscope channels to provide simultaneous low- and high-gain views for wider dynamic range measurement
Find us at www.keysight.com
Page 30
High-sensitivity Current Probes (Continued)
Probe characteristics and specification
Bandwidth (–3 dB) Zoom-out channel: DC to 3 MHz
Zoom-in channel: DC to 500 kHz
Risetime (Tr = 0.35/bandwidth, 10 to 90%) Zoom-out channel: < 0.116 μs
Zoom-in channel: < 0.7 μsec
Minimum measurable current 1 250 μA (with N2822A 20 mΩ, 500 mW)
50 μA (with N2824A 100 mΩ, 500 mW) 5 mA (with N2825A user-defined 1 mΩ, 500 mW) 50 μA (with N2825A user-defined 1 kΩ, 500 mW)
Maximum measurable current 5 A (with N2822A 20 mΩ, 500 mW)
2.2 A (with N2824A 100 mΩ, 500 mW)
5 A 2 (with N2825A user-defined 1 mΩ, 500 mW)
1.2 mA 2 (with N2825A user-defined 1 kΩ, 500 mW)
DC amplitude accuracy ± 3% or 10 μA (whichever is greater)
3
Gain
Max input voltage ± 12 V Output impedance 1 MΩ Standard accessories 1 each 20 mΩ resistor sensor head
Compatible InfiniiVision oscilloscopes InfiniiVision 3000 X-Series (with software version 2.30 or higher)
Max number of probes supported by 3000 X-Series Two N2820A probes using both pods or two N2821A probes Max number of probes supported by 4000 X-Series Two N2820A probes using both pods, four N2820A probes using only the primary pod, or four
Zoom-in channel: 300 ± 3% Zoom-out channel: 1.97 ± 3%
1 each 100 mΩ resistor sensor head
1 each user-defined resistor sensor head 5 each twisted leads (22 AWG) with sockets 5 each twisted leads (22 AWG) without sockets 5 each MBB headers 5 each MBB receptacles
1 each ground lead 1 each screw driver
1 each passive cable (with N2820A only) 1 each user guide manual (English)
InfiniiVision 4000 X-Series (with software version 3.10 or higher) InfiniiVision 6000 X-Series (with software version 6.00 or higher)
N2821A probes
1. Vsupply is equal to 5 V, solder attached.
2. Max current varies with max resistor power rating. The examples in the table assume 500 mW power rating.
3. Denotes warrantied specification after 20-minute warm up. All others entries in the table are characteristics.
Ordering information for Keysight current probes
Model numbers Descriptions
N2820A High-sensitivity 2-ch current probe N2821A High-sensitivity 1-ch current probe
Replacement part numbers
N2822A 20 mΩ resistor tips N2824A 100 mΩ resistor tips N2825A User-defined resistor tips
N2826A Replacement wires (15.5 cm, 22 AWG bare wires) (qty 5) N2827A Passive cable (for N2820A secondary channel) N2828A Replacement MBB (make before break) headers (qty 5) N2829A Replacement MBB (make before break) receptacles and 15.5 cm, AWG 22 socketed wires (qty 5 each)
Find us at www.keysight.com
Page 31

Wedge Probe Adapters

– Easy connection to surface mount
ICs – Safe, with no chance of shorting – Mechanically non-invasive contact – 3-, 8-, and 16-signal versions – Supports 0.5 and 0.65-mm – TQFP and PQFP packages
Problem-free probing
The Keysight wedge probe adapter eliminates many of the frustrations associated with probing surface mount components. If you have ever accidentally shorted IC pins together, experienced electrical and/or mechanical problems with soldering small wires onto leads, or gotten frustrated juggling multiple probes while you are trying to operate your scope, the Wedge was designed with you in mind.
Make the inaccessible accessible
When you use the Wedge, you do not have to worry about shorting IC pins together on a delicate component–or on an irreplaceable prototype. The Wedge is easy to insert and it stays put. There is no need to solder small wires onto leads. The Wedge is mechanically non-invasive, so you will not damage the legs of the IC. Instead, you will have easy access to hard-to-reach components.
IC clip kits
An inexpensive solution for probing fine-pitch ICs, the 10072A SMT kit includes 10 IC clips and 2 dual-lead adapters that connect the clips directly to 10070-family probes.
The 10075A 0.5-mm IC clip kit is ideal for connecting to ICs as fine as 0.5 mm. The clip body allows many clips to be mounted side-by-side. The kit includes four 0.5-mm IC clips and two dual-lead adapters that connect the IC clips directly to 10070-family probes.
Keysight Wedge electrical characteristics
Operating voltage Operating current Capacitance between contacts
Self-inductance 15 nH typical (all except
Cross coupling –31 dB typical at 100 MHz
Contact resistance
< 40 Vdc + peak ac
0.5 A maximum
2 pF typical (all except Keysight-E2643A/44A)
4.33 pF typical at 1 MHz (Keysight-E2643A/44A)
Keysight E2643A/44A) 37 nH typical at 1 MHz (Keysight E2642A/44A)
(Keysight E2643A/44A)
< 0.1 Ω
Ordering information
E2613A 0.5 mm Wedge probe adapter,
3 signal, qty 1
E2614A 0.5 mm Wedge probe adapter,
8 signal, qty 1
E2643A 0.5 mm Wedge probe adapter,
16 signal, qty 1
E2615A 0.65 mm Wedge probe adapter,
3 signal, qty 1
E2616A 0.65 mm Wedge probe adapter,
8 signal, qty 1
E2644A 0.65 mm Wedge probe adapter,
16 signal, qty 1 10072 A SMT kit for 10070 probe family 10075 A 0.5 mm IC clip kit
Electrical reliability
The Wedge makes two contact points with each leg of the IC. This redundant physical connection increases the electrical reliability of the connection. The Wedge’s low capacitance and inductance provides superior performance to many other alternatives.
The Wedge probe adapter connects directly to 1145A/1155A active probes and the dual lead adapter provided with the 1160A-65A passive probe family and N2877A/N2879A accessory kits for use with N287x A Series passive probes.
Find us at www.keysight.com
Page 32

Miscellaneous Accessories

Testmobile
The sturdy Keysight 1180CZ Testmobile for use with 6000 Series oscilloscopes makes sharing your scope easy. Its large wheels make it easy to roll from place to place. For use with the Keysight 6000 Series scope, the 1180CZ Testmobile scope cart with the N2919A bracket provides convenient mobility and secure mounting of your scope.
Specifications for the Keysight Testmobiles
1180CZ
Total load capacity Tilt tray 45.7 cm wide x 45.7 cm deep
59 kg (130 lbs)
(18 in wide x 18 in deep)
Carrying cases
The Keysight N6457A soft carrying case makes transporting and shipping your 2000 X- and 3000 X-Series oscilloscope safe and simple. An oscilloscope and other accessories fit neatly inside the padded shell for shipment. For use with the 7000, 4000 X-, and 6000 X-Series, order N2733B soft carrying case.
N2760A soft carrying case for the 5000 Series
Rackmount kit
The Keysight N2916B rackmount kit positions your 5000 and 6000 Series scope in the center of the rack. Each kit includes a custom shelf with rails, six BNC pass-throughs and all necessary screws. For mounting the 7000 Series in the rack, order N2732A. For mounting all 2000 X- and 3000 X-Series in a rack, order N6456A. For mounting any 4000 X-Series in a rack, order N2763A. For mounting a 6000 X-Series in a rack, order the N2111A .
Ordering information
1180CZ Testmobile for 6000 Series N2919A Bracket for 1180CZ Testmobile and
6000 Series scope
N2917B Hard carrying case for 5000 and
6000 Series
N6457A Soft carrying case for 2000 X- and
3000 X-Series
N2733B Soft carrying case for 7000, 4000
X- and 6000 X-Series N2760A Soft carrying case for 5000 Series N2916B Rackmount kit for 5000 and 6000
Series N2732A Rackmount kit for 7000 Series N6456A Rackmount kit for 2000 and 3000
X-Series N2763A Rackmount kit for 4000 X- Series N2111A Rack mount kit for 6000 X-Series
Find us at www.keysight.com
N2733B soft carrying case for 7000, 4000 X-, and 6000 X-Series
N2916B rackmount kit for 5000/6000 Series
Page 33
Miscellaneous Accessories (Continued)
Probe positioners
– Easy-to-manipulate probe arms for
hands-free browsing
– One- or two-ar ticulated arms with
stable high-mass base (N2784A and N2785A)
– Quick and stable XY positioning
(N2786A)
– Stable 3D probe positioning for
hard-to-reach XYZ access (N2787A – Compatible with most scope probes – Applications: Hands-free browsing for
electronic components on PC board
The N2784A and N2785A probe positioners provide quick and stable X-Y positioning for PC boards and devices that require hands-free probing.
Unlike other probe positioners that require multiple adjustments to lock the probe holder into position, the N2784A and N2785A need only the “lift and drop” motion to put the probe in place. The weight stabilization technique used in these probe holders keeps constant pressure at the probing point so the probe tip stays in position even when the target board is bumped.
The N2786A is a low cost, easy-to-use X-Y axis probe holder for general purpose probing applications. The two-legged positioner is designed to be easy to use–the positioner itself has no controls to position it in place.
Ordering information
Product number Description
N2784A N2785A N2786A 2-leg probe positioner N2787A 3D probe positioner
1. Includes 3x magnifying glass, arm strap,
N2784A one-arm probe positioner
1
1
cable tie, probe rest, and manual.
1-arm probe positioner 2-arm probe positioner
The N2787A is a 3D probe positioner with a flexible, articulating arm that can be quickly positioned in a variety of configurations.
For more information about Keysight’s probe positioners, refer to literature number 5989-9131EN.
Find us at www.keysight.com
N2786A 2-leg probe positioner N2787A 3D probe positioner
Page 34

T2A Probe Interface Adapter

– Enables Tektronix TekProbe-BNC
level 2 probes to connect to
Keysight’s AutoProbe interface
on InfiniiVision 3000 X-, 4000 X-,
6000 X-, 5000, 6000, and 7000
oscilloscopes – An easy-to-use plug-on adapter
to the Keysight oscilloscope’s
AutoProbe interface – Provides necessary probe power,
calibration, and of fset control as
needed to the attached TekProbe
probe
The N2744A T2A interface adapter enables selected TekProbe interface level 2 probes to be used with Keysight oscilloscopes with the AutoProbe interface. Existing TekProbe-BNC probe types can simply be plugged into the T2A adapter, which is then plugged directly into any AutoProbe input channel on an InfiniiVision or Infiniium oscilloscope. Select the probe model in the scope menu and the Keysight oscilloscope sets up the attenuation factor and the probe type automatically. The T2A interface adapter supplies the necessary probe power, calibration (for selected models only), and offset control as used by the connected TekProbe probe. The adapter is targeted for customers using both Tek active probes with TekProbe-BNC level 2 interfaces and Keysight oscilloscopes with the AutoProbe interface.
Tek probe compatibility
The N2744A T2A adapter suppor ts only the probes listed with TekProbe interfaces.
AC/DC current probe
TCP202 50-MHz AC/DC current probe
Single-ended active probes
P6243 Single-ended active probe, 1 GHz,
10:1 without offset control
P6245 Single-ended active probe,
1.5 GHz, 10:1 with offset control
P6205 Single-ended active probe,
750 MHz, 10:1 without offset control
P6 241 Single-ended active probe, 4 GHz,
10:1 with offset control
P6249 Single-ended active probe, 4 GHz,
5:1 with offset control
Differential active probes
P5205 or P5205A P5210 or P5210A P6246 400 MHz, 10:1/1:1 with offset
P6247 1 GHz, 10:1/1:1 with of fset control P6248 1.5 GHz, 10:1/1:1 with of fset
P6250 500 MHz, 50:1/5:1 with offset
P6251 1 GHz, 50:1/5:1 with offset control
Differential probe, 100 MHz, 50:1/500:1 with offset control Differential probe, 50 MHz, 100:1/1000:1 with offset control
control
control
control
Keysight scope compatibility
– Keysight InfiniiVision 6000 X-Series
with software version 6.00 or higher
– Keysight InfiniiVision 3000 X-/4000
X-Series with software version 1.10 or higher
– Keysight InfiniiVision 5000, 6000,
and 7000 Series and future revisions (except 6000 100-MHz) with software version 06.16 or higher
Optical-to-Electrical Converters (works with InfiniiVision 5000, 6000 and 7000 with version
6.16 software only)
P6701B 1 GHz optical-to-electrical
converter with FC/PC connector
P6703B 1.2 GHz optical-to-electrical
converter with FC/PC connector
P6711 250 MHz optical-to-electrical
converter
P6713 300 MHz optical-to-electrical
converter
Ordering information
N274 4 A T2A probe interface adapter
Find us at www.keysight.com
Page 35

Recommended Probes for Low-/Mid-speed Bus Measurements

Applications Speed and signal type Recommended probe Required probe bandwidth
LIN 625 kbps, Single-ended SE passive (high Z) >50 MHz ARINC 425 100 kbps, Differential N2792A/N2818A 200 MHz CAN 2.0 5 Mbps, Differential N2792A/N2818A 200 MHz CAN FD 10 Mbps, Differential N2792A/N2818A 200 MHz MIL Std 1553 1 Mbps, Differential SE passive > 100 MHz +/-25Vpp N2792A/N2818A 200 MHz > 100 MHz I2S (audio) ~2.8 MHz, Single-ended SE passive (high Z) >10 0 MHz I2C/SMbus <4 MHz, Single-ended SE passive (high Z) >10 0 M H z RS232/UART <10 Mbps, Single-ended SE passive (high Z) >10 0 MH z RS422/485 10 Mbps, Differential N2792A/N2818A 200 MHz Flexray 10 Mbps, Differential N2792A/N2818A 200 MHz SPI 1 – 100MHz, Single-ended SE passive (high Z) or N2795A >100 MHz passive or 1 GHz active MOST 150 Mbps, Differential N2750A 1.5 GHz USB2.0 480 Mbps, Differential N2750A 1.5 GHz USB power delivery 300 kbps, Single-ended SE passive (high Z) >50 MHz
Find us at www.keysight.com
Page 36
Keysight Oscilloscopes
Multiple form factors from 20 MHz to > 90 GHz | Industry leading specs | Powerful applications
Learn more at: www.keysight.com
For more information on Keysight Technologies’ products, applications or services,
please contact your local Keysight office. The complete list is available at:
www.keysight.com/find/contactus
Find us at www.keysight.com
This information is subject to change without notice. © Keysight Technologies, 2019 - 2020, Published in USA, May 18, 2021, 5968-8153EN