Keysight CX3322A, CX3324A Quick Operation Manual

Keysight Technologies CX3300 Series Device Current Waveform Analyzer
CX3322A 2-Channel Model CX3324A 4-Channel Model
Warranty
THE MATERIAL CONTAINED IN THIS DOCUMENT IS PROVIDED “AS IS,” AND IS SUBJECT TO BEING CHANGED, WITHOUT NOTICE, IN FUTURE EDITIONS. FURTHER, TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, KEYSIGHT DISCLAIMS ALL WARRANTIES, EI­THER EXPRESS OR IMPLIED, WITH REGARD TO THIS MANUAL AND ANY INFORMATION CONTAINED HEREIN, INCLUDING BUT NOT LIM­ITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FIT­NESS FOR A PARTICULAR PUR­POSE. KEYSIGHT SHALL NOT BE LIABLE FOR ERRORS OR FOR INCI­DENTAL OR CONSEQUENTIAL DAM­AGES IN CONNECTION WITH THE FURNISHING, USE, OR PERFOR­MANCE OF THIS DOCUMENT OR OF ANY INFORMATION CONTAINED HEREIN. SHOULD KEYSIGHT AND THE USER HAVE A SEPARATE WRITTEN AGREEMENT WITH WAR­RANTY TERMS COVERING THE MA­TERIAL IN THIS DOCUMENT THAT CONFLICT WITH THESE TERMS, THE WARRANTY TERMS IN THE SEPARATE AGREEMENT SHALL CONTROL.
Safety Information
A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions
are fully understood and met.
A WARNING notice denotes a haz­ard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met.
U.S. Government
Rights
The Software is “commercial computer software,” as defined by Federal Acquisi­tion Regulation (“FAR”) 2.101. Pursuant to FAR 12.212 and 27.405-3 and Depart­ment of Defense FAR Supplement (“DFARS”) 227.7202, the U.S. govern­ment acquires commercial computer software under the same terms by which the software is customarily provided to the public. Accordingly, Keysight pro­vides the Software to U.S. government customers under its standard commercial license, which is embodied in its End User License Agreement (EULA), a copy of which can be found at http://
www.keysight.com/find/sweula. The li-
cense set forth in the EULA represents the exclusive authority by which the U.S. government may use, modify, distribute, or disclose the Software. The EULA and the license set forth therein, does not require or permit, among other things, that Keysight: (1) Furnish technical infor­mation related to commercial computer software or commercial computer soft­ware documentation that is not custom­arily provided to the public; or (2) Relin­quish to, or otherwise provide, the gov­ernment rights in excess of these rights customarily provided to the public to use, modify, reproduce, release, perform, dis­play, or disclose commercial computer software or commercial computer soft­ware documentation. No additional gov­ernment requirements beyond those set forth in the EULA shall apply, except to the extent that those terms, rights, or licenses are explicitly required from all providers of commercial computer soft­ware pursuant to the FAR and the DFARS and are set forth specifically in writing elsewhere in the EULA. Keysight shall be under no obligation to update, revise or otherwise modify the Software. With respect to any technical data as defined by FAR 2.101, pursuant to FAR 12.211 and 27.404.2 and DFARS 227.7102, the U.S. government acquires no greater than Limited Rights as defined in FAR
27.401 or DFAR 227.7103-5 (c), as appli­cable in any technical data.
Notices
Copyright Notice
© Keysight Technologies 2018
No part of this manual may be repro­duced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written con­sent from Keysight Technologies as gov­erned by United States and international copyright laws.
Manual Part Number
CX3300-90300
Edition
Edition 1, June 2018
Published by:
Keysight Technologies International Japan G.K. 9-1, Takakura-cho, Hachioji-shi, Tokyo 192-0033 Japan
Technology Licenses
The hardware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license.
Declaration of Conformity
Declarations of Conformity for this prod­uct and for other Keysight products may be downloaded from the Web. Go to
http://www.keysight.com/go/conformity
and click on “Declarations of Conformi­ty.” You can then search by product number to find the latest Declaration of Conformity.
CAUTION
WARNING
Contents
1. File
How to save the data
How to load the data
What types of data formats are supported on the CX3300 ?
How to save rarely occurring waveforms automatically
2. Setup
How to change the horizontal scale and position
How to change the sampling rate
How to change the memory depth
How to change the 14-bit or 16-bit resolution
How to change the vertical scale and position
How to change the current range
How to set the bandwidth limit
How to minimize the offset current
How to perform a Skew adjustment
What determines the effective bandwidth of the instrument ?
How to zoom in on the waveform
How to use the waveform memory
How to overlay multiple acquisitions
How to display the secondary Y axis
3. Trigger
How to set the trigger
4. Measure
How to apply a Measurement Function
How to apply the A-B marker
How to place pointers on waveforms
How to add an Annotation
5. Analyze
How to apply the post-filter
How to perform the FFT ( Fast Fourier Transform )
How to analyze the waveform in the specified area with an Area marker
How to apply the Power and Current Profiler
How to apply the XY analysis
6. Utilities
How to change the measurement units (Clone to Ampere Hour) in Area analysis
How to perform User calibration
How to check the firmware revisions
How to simulate the 50 MHz or 100 MHz bandwidth option on the mainframe with the 200 MHz option
Where to find the Online help
How to display the menu bar
Keysight Technologies CX3300 Current Waveform Analyzer
Quick Operation Guide How to save the waveform data
- How to save the Waveform data in CSV format.
- How to save the Waveform FFT data in CSV format.
Save
“Spectrum- Magnitude” or “Spectrum- Phase”
1
2
3
4
5
6
7
Waveform
csv
Save
1
2
3
4
5
6
7
Waveform
csv
Channel 1
4
- How to save the Window Image data (Format : PNG / JPEG / Bitmap).
- How to save all setting data and waveform data (File Type : Composite).
Save
1
2
3
4
5
6
Screen Capture
PNG or JPEG or Bitmap
Save
1
2
3
4
5
Composite
Note:
- For further details about the File Type and Format, please refer to “What types of data formats are supported on the CX3300 ?”.
5
Keysight Technologies CX3300 Current Waveform Analyzer
Quick Operation Guide How to load the data
Load
Select one of folders to access
1
2
3
4
5
In this case, select Waveform File (*.cxwav).
SelectedFile.cxwav
Note:
- For further details about the File Type and Format, please refer to “What types of data formats are supported on the CX3300?”.
6
Keysight Technologies CX3300 Current Waveform Analyzer
Quick Operation Guide What types of data formats are supported on the CX3300 ?
The CX3300 supports several File Types and Formats when the setup data or the waveform data is saved or loaded.
File Type Format
Save Load
Setup Data Setup Data
Waveform (Waveform data)
CSV
No Yes No
No TSV No Waveform Yes HDF5 Yes
Report (Outputs the measurement and analysis result report in the dedicated style)
XPS
Acquisition and channel setups on the summary bar
Measurement and analysis result
No
CSV TSV
Text
Composite (All setup data and waveform data)
- Yes Yes Yes Yes
Screen Capture (Image of the CX3300 full screen)
PNG
The images on the screen NoJPEG
Bitmap
Setup (All setup data or trigger setup data only)
-YesNoYesNo
[ Detail of the File Type and Format ]
7
Keysight Technologies CX3300 Current Waveform Analyzer
Quick Operation Guide How to save rarely occurring waveforms automatically
1. Select “Utilities > Configuration > Auto Save”.
Utilities
1
2
3
Change Limit Count
4
5
Blinking
Checked
"Auto Save" can be used to automatically save a current waveform if it satisfies specific conditions.
8
Note:
- During the processing for previously acquired waveforms, the data is not saved even if the specified condition is satisfied.
- Depending on the File Type and Limit Count, the size or number of the files to be saved increases.
2. Push the “Auto Save” ( red circle ) button on the lower left of the display. The waveforms consistent with the trigger condition are stored up until the Limit Count set on the “Configuration > Auto Save” window.
This number is counted up until the Limit Count.
The 5 files are created in this sample.
The icon shows the disk usage. When the free space becomes 10% or less, the color changes from green to red.
9
Keysight Technologies CX3300 Current Waveform Analyzer
Quick Operation Guide How to change the horizontal scale and position
Horizontal Controls
Change the scale
Change the position. Pressing it sets zero offset.
Horizontal Summary
a
b
c
You can change the horizontal scale and position using any of the following methods:
a) Using the knobs on the Horizontal Controls b) Using the Horizontal mini dialog box c) Using the X Axis dialog box for fine control.
Double-Click
Click
10
Keysight Technologies CX3300 Current Waveform Analyzer
Quick Operation Guide How to change the sampling rate
1. Click on the Horizontal summary to open the Horizontal mini dialog box.
2. Un-check “Automatic”.
3. Set the “Sampling Rate”.
Note:
- If “Auto” is enabled, a suitable sampling rate is selected automatically by the horizontal scale setting controlled by the Horizontal scale control knob.
1
3
2
11
Keysight Technologies CX3300 Current Waveform Analyzer
Quick Operation Guide How to change the memory depth
1. Click on “Horizontal summary” to open the “Timebase” mini dialog box.
2. Click on the “ ” at the upper right of the mini dialog box to open
the Setting
dialog box.
3.
Select “Acquisition”.
4. Un-check “Automatic”.
5. Set the “Memory Depth”.
Analysis
3
4
5
Horizontal Summary
1
2
12
Keysight Technologies CX3300 Current Waveform Analyzer
Quick Operation Guide How to change the 14-bit or 16-bit resolution.
a
Change a 14-bit (high speed mode) or a 16-bit (high resolution mode) using the [High Reso] key.
Indicator on Horizontal Summary (none) : 14-bit (high speed mode) “HR” : 16-bit (high resolution mode)
Note: The maximum sampling rate and bandwidth is automatically changed by the mode.
Resolution Max. Sampling Max. Bandwidth
14-bit (high speed mode) 1 G Sa/s 200 MHz
16-bit (high resolution mode) 75 Msa/s 15 MHz
13
Keysight Technologies CX3300 Current Waveform Analyzer
Quick Operation Guide How to change the vertical scale and position
1. How to select the channel. Select the target waveform by either:
a) Pressing [1], [2], [3] or [4] for the analog input channels OR b) Clicking on the icons on the Waveform tray for the analog input
channels or function waveform.
Vertical control keys
Waveform tray
LED shows the selected analog channel.
The color of the Y axis is the same color as the selected waveform.
The icon for the selected waveform is highlighted.
b
a
14
2. How to Change the horizontal scale and position
You can change the horizontal scale and position using any of the
following
methods:
a) Using the knobs on Vertical Controls b) Using the Vertical mini dialog box c) Using the Y Axis dialog box for fine control.
Vertical control keys
Change the position. Pressing it sets zero offset.
Click
Channel summary
a
b
Double-Click
c
Change the scale
15
Keysight Technologies CX3300 Current Waveform Analyzer
Quick Operation Guide How to change the current range
1. Click on the Channel summary to open the Channel mini dialog box.
2. Un-check “Auto”.
3. Select the “Range”.
Note:
- If “Auto” is enabled, a suitable range is selected automatically by the vertical scale setting controlled by the Vertical scale control knob.
- The measurement bandwidth and the input resistor are automatically changed by changing the range.
1
3
2
Click
16
Keysight Technologies CX3300 Current Waveform Analyzer
Quick Operation Guide How to set the bandwidth limit
1. Click on the Channel summary to open the Channel mini dialog box.
2. Click on the “ ” at the upper right of the window to open the Setting dialog box.
3. Select “ON”.
4. Set the bandwidth limit.
1
4
3
Setting
> Channels
> Channel X
2
17
Keysight Technologies CX3300 Current Waveform Analyzer
Quick Operation Guide How to minimize the offset current
1. Perform “User Calibration”. The offset current of the current sensor will be minimized.
2. Perform a actual measurement and fix the connection and the CX3300 settings such as the current range.
3. Perform a “Null” measurement.
DUT
Mainframe + Current Sensor
User Calibration Null
DUT
VIN
GND
Ground lead
Connection Example
DUT
VIN
GND
Ground lead
Actual measurement
Null measurement
3-1. Make a connection to prevent the current flow into the current sensor.
Note for connection:
- Connect either the (+) or (-) terminal of the current sensor to the stable voltage on the DUT.
- Connect the ground lead to the circuit common of the DUT.
Remove the test lead of the (+) terminal to prevent the current flow into the current sensor
18
3-2. Null measurement
1. Click on the Channel summary to open the Channel mini dialog box.
2. Turn “ON” the Null measurement.
3. Press “Measure”.
Click
1
3 2
The Null offset is automatically subtracted from the waveform
The Null indicator turned on.
4. Restore the connection then make an actual measurement again.
Note: The Null offset is set to zero when:
- The current sensor is disconnected
- The User Calibration is performed
- The CX3300 is closed or turned off.
19
Keysight Technologies CX3300 Current Waveform Analyzer
Quick Operation Guide How to perform a Skew adjustment
The skew between the channels on the measurement device can be adjusted.
1. Preparation 1-1. Connect the Current Sensor (CX1101A/CX1102A/CX1103A) or the
Passive Probe Interface Adapter (CX1151A) to the device.
1-2. Execute the measurement.
2. Settings 2-1. Click on the “Setting” icon. 2-2. The “Setting” dialog box opens. 2-3. Click on “Setting>Channels>Skew". 2-4. The Skew setup panel opens and the waveforms for the effective
channels are shown behind the “Setting” dialog box.
2-5. Adjust the skew of the other channels to the triggered channel
while observing the waveforms behind the “Setting” dialog box.
Setting
Skew setup panel
2-1
2-2
2-3
2-5
2-4
20
Loading...
+ 46 hidden pages