No part of this manual may be
reproduced in any form or by any
means (including electronic storage
and retrieval or translation into a foreign
language) without prior agreement and
written consent from Keysight
Technologies, Inc. as governed by
United States and international
copyright laws.
Manual Part Number
89600-90291
Published By
Keysight Technologies, Inc.
1400 Fountaingrove Pkwy.
Santa Rosa, CA 95403 USA
Edition
November, 2020
Printed inUSA
Regulatory Compliance
This product has been designed and
tested in accordance with accepted
industry standards, and has been
supplied in a safe condition.
Warranty
THE MATERIAL CONTAINED IN THIS
DOCUMENT IS PROVIDED “AS IS,” AND
IS SUBJECT TO BEING CHANGED,
WITHOUT NOTICE, IN FUTURE
EDITIONS. FURTHER, TO THE
MAXIMUM EXTENT PERMITTED BY
APPLICABLE LAW, KEYSIGHT
DISCLAIMS ALL WARRANTIES, EITHER
EXPRESS OR IMPLIED, WITH REGARD
TO THIS MANUAL AND ANY
INFORMATION CONTAINED HEREIN,
INCLUDING BUT NOT LIMITED TO THE
IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR
A PARTICULAR PURPOSE. KEYSIGHT
SHALL NOT BE LIABLE FOR ERRORS
OR FOR INCIDENTAL OR
CONSEQUENTIAL DAMAGES IN
CONNECTION WITH THE
FURNISHING, USE, OR
PERFORMANCE OF THIS DOCUMENT
OR OF ANY INFORMATION CONTAINED
HEREIN. SHOULD KEYSIGHT AND THE
USER HAVE A SEPARATE WRITTEN
AGREEMENT WITH WARRANTY TERMS
COVERING THE MATERIAL IN THIS
DOCUMENT THAT CONFLICT WITH
THESE TERMS, THE WARRANTY
TERMS IN THE SEPARATE
AGREEMENT SHALL CONTROL.
KEYSIGHT TECHNOLOGIES DOES NOT
WARRANT THIRD-PARTY SYSTEMLEVEL (COMBINATION OF CHASSIS,
CONTROLLERS, MODULES, ETC.)
PERFORMANCE, SAFETY, OR
REGULATORY COMPLIANCE, UNLESS
SPECIFICALLY STATED.
Technology Licenses
The hardware and/or software
described in this document are
furnished under a license and may be
used or copied only in accordance with
the terms of such license.
U.S. Government Rights
The Software is “commercial computer
software,” as defined by Federal
Acquisition Regulation (“FAR”) 2.101.
Pursuant to FAR 12.212 and 27.405-3
and Department of Defense FAR
Supplement (“DFARS”) 227.7202, the
U.S. government acquires commercial
computer software under the same
terms by which the software is
customarily provided to the public.
Accordingly, Keysight provides the
Software to U.S. government customers
under its standard commercial license,
which is embodied in its End User
License Agreement (EULA), a copy of
which can be found at
http://www.keysight.com/find/sweula. The
license set forth in the EULA represents
the exclusive authority by which the
U.S. government may use, modify,
distribute, or disclose the Software. The
EULA and the license set forth therein,
does not require or permit, among other
things, that Keysight: (1) Furnish
technical information related to
commercial computer software or
commercial computer software
documentation that is not customarily
provided to the public; or (2) Relinquish
to, or otherwise provide, the
government rights in excess of these
rights customarily provided to the
public to use, modify, reproduce,
release, perform, display, or disclose
commercial computer software or
commercial computer software
documentation. No additional
government requirements beyond
those set forth in the EULA shall apply,
except to the extent that those terms,
rights, or licenses are explicitly required
from all providers of commercial
computer software pursuant to the FAR
and the DFARS and are set forth
specifically in writing elsewhere in the
EULA. Keysight shall be under no
obligation to update, revise or otherwise
modify the Software. With respect to
any technical data as defined by FAR
2.101, pursuant to FAR 12.211 and
27.404.2 and DFARS 227.7102, the U.S.
government acquires no greater than
Limited Rights as defined in FAR 27.401
or DFAR 227.7103-5 (c), as applicable in
any technical data.
Safety Notices
A CAUTION notice denotes a hazard. It
calls attention to an operating
procedure, practice, or the like that, if
not correctly performed or adhered to,
could result in damage to the product
or loss of important data. Do not
proceed beyond a CAUTION notice until
the indicated conditions are fully
understood and met.
A WARNING notice denotes a hazard. It
calls attention to an operating
procedure, practice, or the like that, if
not correctly performed or adhered to,
could result in personal injury or death.
Do not proceed beyond a WARNING
notice until the indicated conditions are
fully understood and met.
2
Page 3
In This Book
This guide documents how to install the Keysight 89600 software and a transportable
license. It also documents how to view the software's online help and demo signal
packages.
Other Documentation
In addition to the Quick Start Guide (this book), the following documentation is
included with your software:
The 89600 Software Installation Guide (InstallationGuide.pdf) is available on
the installation DVD in the manuals folder, during installation by clicking MoreInstallation Choices > View Installation Guide, or after you install the software
in C:\Program Files\Keysight\89600Software <ReleaseVersion>\89600VSASoftware\Help.
The 89600 Online Help is available after you install the software on your
computer. The help provides use and operation information.
If you install the IO libraries, the complete documentation for the Keysight IO
libraries is available by right-clicking the Keysight IO Libraries Suite icon in the
Windows task bar's Hidden Icons panel and selecting Documentation.
Technical Specifications are available from the 89600 web page:
http://www.keysight.com/find/89600
To read the PDF files, you must have Acrobat Reader installed on
your computer. To install the latest Acrobat Reader, go to:
Installing 89600 Software in a PC18
Installing 89600 Software in a Keysight X-Series Signal Analyzer21
Installing 89600 Software in a Keysight Infiniium Scope23
Installing 89600 Software in a Keysight Logic Analyzer25
Installing Licenses27
Transportable License28
Redeeming a transportable license28
Installing a transportable license29
Using the VSA Online Help and Demos31
Accessing Help32
Help menu32
Dynamic help33
Help button on dialogs33
F1 on the keyboard33
Recalling a Demo Signal Package35
5
Page 6
6
Page 7
Overview
Overview
89600 Software
The Keysight PathWave 89600 VSA Quick Start Guide provides all necessary
instructions to install the Keysight 89600 software and a transportable license
89600 Software
The Keysight 89600 software's installation wizard guides you though the installation
process.
7
Page 8
Overview
Licensing
Licensing
There are four types of licenses:
Demo: The Demo license is provided with the 89600 software installation and
enables you to use the 89600 software with limited functionality.
Trial: The Trial license lets you immediately start using a fully licensed 89600
software application for a temporary trail period. When the trial period expires,
you will need to purchase a valid license for continued use.
Node-locked: The node-locked license is used to license the Keysight 89600
software plus options to only run on one specified host PC.
Transportable: The Transportable license is used to license the Keysight 89600
software plus options to only run on the host PC. However, you do have the
capability to transport the license to a different PC, making it the new host PC.
Floating: The Floating or Network license provides the ability for different PC's
to use a license that is stored on a network PC (or server).
USB portable: The USB portable license is used to license 89600 VSA software
with options to only run on one host PC with certified USB dongle, which needs
be purchased separately.
You can move the USB portable license together with the certified USB dongle
from one Host PC to another Host PC.
This Quick Start Guide documents how to install the transportable license. For
information on how to install the demo, trial, or floating license types, see the
Installation Guide (InstallationGuide.pdf) available on the installation DVD in the
manuals folder, during installation by clicking More Installation Choices > View
Installation Guide, or after you install the software in C:\Program
Files\Keysight\89600 Software <ReleaseVersion>\89600 VSA Software\Help.
Keysight 89600 Software Operating Configurations
The Host PC is the computer that will run the Keysight 89600 software. There are two
89600 software operating configurations: Remote PC Operation and Embedded PC
Operation (also referred to as Embedded Instrument Operation). In a Remote PC
Operation, the software runs on a standalone host PC linked to the measurement
hardware via the I/Ointerface, such as LAN, GPIB, USB, and IEEE 1394.
889600 Software Quick Start Guide
Page 9
Overview
Installation and Configuration Process
In an Embedded PC Operation, the 89600 software runs on a PC embedded in the
measurement hardware platform such as the Keysight X-Series Analyzer, Keysight
Infiniium Scope, and Keysight Logic Analyzer.
Installation and Configuration Process
The Keysight 89600 software installation process includes the following primary
steps:
1. Set up and configure the remote PC.
Skip this step if you are installing the software in an embedded
PC operation.
Go to Chapter 2 Configuring Remote PC (page 11) to setup and configure the
remote PC hardware including:
2. Install the 89600 software.
Go to Chapter 3 Installing 89600 Software (page 17) and follow the instructions to
install the Keysight 89600 software.
3. License the Keysight 89600 software.
Go to Chapter 4 Installing Licenses (page 27) and follow the instructions to license
the Keysight 89600 software and option.
89600 Software Quick Start Guide9
Page 10
1089600 Software Quick Start Guide
Page 11
Configuring Remote PC
This chapter only applies to the remote PC operation configuration. This contains
information to setup and configure the PC including system requirements, I/O
interface requirements, and the PC interface installation and setup procedure.
If you are going to install the software in an embedded PC
operation, skip this chapter and go directly to Installing 89600
Software (page 17).
Configuring Remote PC
11
Page 12
Configuring Remote PC
Configuration Steps
Configuration Steps
1. Verify your PC meets the system requirements listed in the following table.
CharacteristicRequirement
Operating systemMicrosoft Windows 7 Professional, Enterprise or Ultimate (64
bit, for 89600 VSA version v22.0 or above)
Microsoft Windows 10 Professional, Enterprise or Education
(64 bit, for 89600 VSA version v22.0 or above)
Linux (only for floating license and 89600 VSA version v22.0 or
above)
CPU1 GHz (>2 GHz recommended)
RAM2 GB (16 GB recommended)
Video RAM128 MB (1 GB recommended)
Graphics supportOpenGL version of 2.1 or higher required for rendering of 3D
trace data in some measurement options
Hard disk3 GB minimum available
Additional drivesDVD to load the software; license transfer requires network
access or a USB memory device
Interface supportLAN, GPIB, USB. For Option SSA, PCIe Express card interface to
PXI mainframe or an embedded PC M9036A/M9037A to be
used
BrowserInternet Explorer Version 9.0 or higher required for full con-
text-sensitive help functionality.
2. Verify that your PC's I/Ointerface meets the requirements listed in the following table.
If you are only using simulated measurement hardware or
signal simulation software, you do not need to
install/configure an I/O interface. You can skip the
remainder of this chapter and go directly to Installing 89600
Software in a PC (page 18).
Using the following table, determine what type of PC and I/O interface is
required for your measurement hardware. Note that you may need to install
and configure more than one interface.
If the PC already supports the I/O interface, skip the remainder of this
chapter and install the 89600 VSA software—go to Installing 89600 Software
in a PC (page 18).
1289600 Software Quick Start Guide
Page 13
Configuring Remote PC
Configuration Steps
If the PC supports the I/O interface but it is not currently installed, you
will need to install and configure the I/O interface hardware on the PC—
go to Installing I/O Interface Hardware (page 15).
If the PC does not support the I/O interface, you can not use the 89600
VSA software with your measurement hardware.
89600 Software Quick Start Guide13
Page 14
Configuring Remote PC
Configuration Steps
Measurement HardwareComputer TypeInterface
Keysight ESALaptop or desktop PCGPIB, or USB/GPIB
adapter
Keysight ESA-E Series
Laptop or desktop PCGPIB or USB/GPIB
Analyzer
Keysight InfiniiVision
Laptop or desktop PCLAN, GPIB, or USB/GPIB
Oscilloscope
Keysight Infiniium Oscilloscope
Keysight Logic AnalyzerLaptop, desktop PC, or
Keysight X-Series Signal
Analyzer
Keysight Handheld RF
Laptop or desktop PC or
embedded Windows 7 scope
LAN, GPIB, USB/GPIB, or
internal
LAN, IEEE-1394 (only for
embedded PC
Laptop, desktop PC, or
1690 Series), or internal
LAN or internal*
embedded PC
Laptop or desktop PCLAN
and Microwave Analyzer
Keysight modular
products
Laptop, desktop PC, or
embedded PC
LAN, GPIB, USB/GPIB or
internal
* The Keysight X-Series Signal Analyzer embedded PC operation only supports
a LAN interface between the analyzer and a Keysight Source.
1489600 Software Quick Start Guide
Page 15
5. Installing I/O Interface Hardware
a. Install I/O Interface Card(s) in the PC.
Install all necessary I/O interface card(s) in the PC per the instructions
that came with the I/O interface card vendor documentation.
National Instruments GPIB card: For a National Instruments GPIB card,
be sure to install the NI 488.2 software first, then reboot your PC and
install the interface card.
Exclude Multiple GPIB Devices: If this PC controls
other GPIB measurement hardware or devices, you
need to exclude those devices from the 89600
identification process.
b. Configure the PC I/O Interface.
Configure the I/O interface card(s) in the PC per the instructions that
came with the I/O interface card vendor documentation.
Configuring Remote PC
Configuration Steps
You can typically use the default I/O interface hardware
settings.
GPIB: For GPIB interfaces, make sure that each
measurement hardware has a unique GPIB address—
multiple GPIB devices cannot use the same GPIB
address.
If the PC and measurement hardware are connected to
a local internal LAN, you may need to check with your
network administrator to verify that the IP addresses for
the PC and measurement hardware satisfy
requirements.
c. Cycle power OFF/ON on all system hardware.
After completing the hardware I/O connections, cycle the power OFF/ON
on the PC and all connected measurement hardware.
d. Next install the 89600 VSA software. Go to Installing 89600 Software in a PC
(page 18).
89600 Software Quick Start Guide15
Page 16
1689600 Software Quick Start Guide
Page 17
Installing 89600 Software
This procedure installs the 89600 VSA software.
There are different installation procedures for each operating configuration—Remote
PC and Embedded PC configuration. Remote PC configuration requires installing the
software in a PC. Embedded PC configuration requires installing the software in the
measurement hardware; there are also different install procedures for different
measurement hardware types.
Select and use the software installation procedure for your particular installation:
Remote PC Configuration
Installing 89600 Software in a PC (page 18)
Embedded PC Configuration
Installing 89600 Software in a Keysight X-Series Signal Analyzer (page 21)
Installing 89600 Software in a Keysight Infiniium Scope (page 23)
Installing 89600 Software in a Keysight Logic Analyzer (page 25)
Installing 89600 Software
17
Page 18
Installing 89600 Software
Installing 89600 Software in a PC
Installing 89600 Software in a PC
To install the Keysight 89600 software in a remote PC configuration:
1. Close any applications you have open.
2. Insert the Keysight 89600 software installation DVD.
3. If the installation utility does not start automatically, navigateto the DVD drive
and double-click this file:
autoplay.exe
4. When the Keysight 89600 Installation Manager window opens, click View
Readme then review the following sections of the Readme file.
To install the Keysight 89600 software, you must have
administrator privileges.
Required Minimum License Version
Installation Information
5. After reviewing the Readme file, start the software installation by clicking
Install PathWave 89600 VSA. Step through the InstallShield Wizard and stop
at the Select Products and Features window.
6. Select the Products and Features you want to install, click Next then continue
through the InstallShield Wizard to complete the installation.
7. If you want to install hardware support after the 89600 software installation
has finished, select More Installation Choices. If you choose not to install
hardware support, you can install it at a later time—see the 89600 Software
1889600 Software Quick Start Guide
Page 19
Installing 89600 Software
Installing 89600 Software in a PC
Installation Guide for instructions.
a. To add hardware support, select Hardware Support Menu.
b. On the Hardware Support dialog, select the components to add then
click Install Hardware Support and follow the prompts to complete the
installation.
8. The installation process configures your system environment for the 89600
software applications. Some installations may required a system PC reboot. If
this occurs, click OK to reboot.
After rebooting you will need to be logged on with
administrative privileges to complete the installation.
When installing from a remotely mounted DVD drive, the
remote drive must be configured to reconnect at logon so that
the installation files can be located after the reboot.
9. When the installation is complete, exit the Installation Manager.
Installing 89600 Software
Installing 89600 Software in a PC
Next the software and options need to be licensed. To learn how to obtain a license,
see Installing Licenses (page 27).
2089600 Software Quick Start Guide
Page 21
Installing 89600 Software
Installing 89600 Software in a Keysight X-Series Signal Analyzer
Installing 89600 Software in a Keysight X-Series Signal
Analyzer
Verify that the Instrument software revision (System hardkey >
Show softkey > System softkey) is A.19.05 or greater.
Since the Keysight X-Series Signal Analyzers do not have internal DVD drives, you
must first copy the contents of the Keysight 89600 software DVD onto a USB Drive.
The Keysight 89600 software DVD is not protected or encrypted. The copy will be
identical to the original DVD.
This procedure assumes that a USB Flash Drive is being used.
Other USB storage devices, such as a USB hard drive or USB DVD
drive, could also be used.
To install the 89600 VSA software in a Keysight X-Series Signal Analyzer using a USB
Flash drive:
1. Insert the Keysight 89600 software DVD into a PC’s DVD drive. If the Keysight
89600 Installation Manager window opens, close the installer program (click
Exit).
2. Insert a USB Flash Drive into a USB port on the same PC in which the Keysight
89600 software DVD is loaded.
3. Use Windows Explorer to copy the contents of the Keysight 89600 software
DVD onto the USB Flash Drive.
4. Connect a USB keyboard and mouse to the analyzer.
To install the Keysight 89600 software on the analyzer, you
need to have administrator privileges. Press Ctrl - Alt - Delete,
then click Log Off.... Log back in as the Administrator.
Depending on your instrument’s installed Windows OS image
version, the default administrator password is either agilent4u
or Keysight4u!.
5. Insert the USB Flash Drive into an available USB port on the analyzer.
6. Open Windows Explorer and navigate to the USB drive.
7. Double-click autoplay.EXE.
8. When the Keysight PathWave Vector Signal Analyzer (89600 VSA) Installer
window opens, please read the Readme information.
9. After you read the Readme file, close it, then click Install 89600 Software.
Continue through the InstallShield Wizard until you reach the Select Productsand Features window.
10. Select the features you want to install, then continue through the InstallShield
89600 Software Quick Start Guide21
Page 22
Installing 89600 Software
Installing 89600 Software in a Keysight X-Series Signal Analyzer
Wizard to complete the installation.
11. When the installation is complete, exit the Installation Manager.
12. Start the X-Series analyzer application: Double-click the LaunchXSA icon on
the Windows desktop.
13. After the X-Series analyzer finishes booting up, start the Keysight 89600
software:
Press the Mode Hardkey, then there is Launch VSA button on the left
bottom of the window. You can choose from the menu below the "Launch
VSA" button to specify the launched 89600 VSA version which has
already been installed inside this signal analyzer.
Next the software and options need to be licensed. To learn how to obtain a license,
see Installing Licenses (page 27).
2289600 Software Quick Start Guide
Page 23
Installing 89600 Software
Installing 89600 Software in a Keysight Infiniium Scope
Installing 89600 Software in a Keysight Infiniium Scope
Embedded operation with the 89600 is not recommended for the
Infiniium 8000 and 80000 Series scopes.
Many Infiniium oscilloscopes provide an open Microsoft Windows 7 operating system
that enables you to install other applications. You can install and operate the 89600
Vector Signal Analysis software on these scopes.
Some Keysight Infiniium scopes have no DVD drive, so for these scopes you must use
a USB drive. If you are installing from a USB drive, you must copy the contents of the
Keysight 89600 software DVD onto the USB Drive. The Keysight 89600 software DVD
is not protected or encrypted. The copy will be identical to the original DVD.
To install the 89600 VSA software in a Windows 7 scope:
1. Increase the scope's virtual memory to at least 1 GB as follows:
a. Minimize the scope application.
b. Navigate to: Control Panel > Administrative Tools (double-click) > Com-
VSA <ReleaseVersion> > Keysight PathWave 89600 VSA <ReleaseVersion>.
Next the software and options need to be licensed. To learn how to obtain a license,
see Installing Licenses (page 27).
2489600 Software Quick Start Guide
Page 25
Installing 89600 Software
Installing 89600 Software in a Keysight Logic Analyzer
Installing 89600 Software in a Keysight Logic Analyzer
Some Keysight Logic Analyzers have no DVD drive, so for these analyzers you must
use a USB drive. If you are installing from a USB drive, you must copy the contents of
the Keysight 89600 software DVD onto the USB Drive. The Keysight 89600 software
DVD is not protected or encrypted. The copy will be identical to the original DVD.
To install the 89600 VSA software in a logic analyzer:
1. Insert the Keysight 89600 software DVD into the logic analyzer's DVD drive. If
your logic analyzer does not have a DVD drive, use the following procedure:
This procedure assumes that a USB Flash Drive is being
used. Other USB storage devices, such as a USB hard drive
or USB DVD drive, could also be used.
a. Insert the Keysight 89600 software DVD into a PC’s DVD drive. If the Key-
sight PathWave Vector Signal Analyzer (89600 VSA) Installer window
opens, close the installer program (click Exit).
b. Insert a USB Flash Drive into a USB port on the same PC that the Key-
sight 89600 software DVD is in.
c. Copy the contents of the Keysight 89600 software DVD onto the USB
Flash Drive.
d. Connect a USB keyboard and mouse to the analyzer.
To install the Keysight 89600 software on the logic
analyzer, you need to log on with administrator
privileges.
e. Insert the USB Flash Drive into an available USB port on the analyzer.
f. Open Windows Explorer and navigate to the USB drive.
g. Double-click autoplay.EXE to bring up the Keysight 89600 Installation
Manager.
2. When the Keysight PathWave Vector Signal Analyzer (89600 VSA) Installer win-
dow opens, please read the Readme information.
3. After you read the Readme file, close it then click Install 89600 Software.
Continue through the InstallShield Wizard until you reach the Select Productsand Features window.
4. Select the features you want to install, then continue through the InstallShield
Wizard to complete the installation.
5. When the installation is complete, exit the Installation Manager.
When installing the 89600 VSA in a logic analyzer
mainframe, Hardware support is disabled. This prevents
89600 Software Quick Start Guide25
Page 26
Installing 89600 Software
Installing 89600 Software in a Keysight Logic Analyzer
using disk space for unnecessary components that are not
needed when the 89600 VSA software is installed in a logic
analyzer.
VSA <ReleaseVersion> > Keysight PathWave 89600 VSA <ReleaseVersion>.
Next, the software and its options must be licensed. To learn how to obtain a license,
see Installing Licenses (page 27).
2689600 Software Quick Start Guide
Page 27
Installing Licenses
The 89600 software and options must be licensed to operate in a useful manner. The
89600 software has Demo, Trial, Node-locked, Transportable, Floating, and USB
portable license types. The Demo license is installed with the 89600 software.
This chapter describes how to install a Transportable license. For instructions on
installing the other types of licenses, see the Installation Guide
(InstallationGuide.pdf), which is available on the installation DVD in the manuals
folder, during installation by clicking More Installation Choices > View InstallationGuide, or after you install the software in C:\Program Files\Keysight\89600 Software<ReleaseVersion>\89600 VSA Software\Help.
Installing Licenses
27
Page 28
Installing Licenses
Transportable License
Transportable License
This section describes the steps to obtain and install a Transportable license. The
Transportable license enables the 89600 software and options that you purchased.
The license must be installed on the same computer that runs the 89600 software.
However, the license can be transferred from one computer to another computer.
Licensing the 89600 Software is a two step process:
1. Redeem the License.
Go to Redeeming a transportable license (page 28).
2. Install the License file.
Go to Installing a transportable license (page 29).
The term PC refers to any computer or instrument (such as
analyzers and oscilloscopes) running the 89600 software.
Redeeming a transportable license
To redeem a Transportable license, follow these steps:
1. Collect the Software License Entitlement Certificates for all 89600 software
options that you purchased. The Software License Entitlement Certificates are
included with the 89600 VSA Software Installation Materials envelope (printed
on gray parchment).
The Software License Entitlement Certificate also includes
instructions to redeem your licenses.
2. Obtain the Host identification information (Host ID) for the PCon which you are
installing the 89600software license. Use the Keysight License Service utility
or Keysight License Manager to obtain the Host ID.
a. Open the About Keysight License Service utility: right click the Keysight
License Service iconin the Windows desktop notification area (lower
right side of the Windows Task bar) and select About Keysight LicenseService.
b. Click the Copy button to the right of the Host IDbox. The Host
IDinformation is copied into the Windows clipboard.
2889600 Software Quick Start Guide
Page 29
Installing Licenses
Transportable License
3. Redeem your licenses and obtain the license files.
Follow the instructions included on the Software License Entitlement
Certificate to redeem your licenses and obtain the license files. Go to the
Keysight Software Manager website:
http://www.keysight.com/find/softwaremanager
First time access will require you to register.
Remember your user password. The password is
required for future access to manage your licenses.
You will need the Keysight Order Number and Keysight Certificate Number located on the top of your Software License Entitlement Certificate.
4. Install License File(s):Check your email for the license file(s) and then install
the license file(s) on the PC—go to Installing a transportable license (page 29).
Installing a transportable license
Installing the license file is necessary to license the 89600 software. After completing
Redeeming a transportable license (page 28), you will receive a Keysight email containing
your license file for the redeemed Entitlement Certificates. Follow these steps to
install the license files on the PC:
1. Copy the email attachment with the .lic file extension to a folder on your PC,
connected hard drive, or USB storage device.
2. Start the Keysight License Manager: in the 89600 software: in the 89600 soft-
ware, click Utilities > Licenses > Status > Keysight License Manager or
double click the Keysight License Service iconin the Windows desktop notification area (lower right side of the Windows Task bar).
3. To install the license file, drag-and-drop the license file onto your computer or
instrument's connection in the Keysight License Manager's list of connections.
See the Add a New License section of the Keysight License Manager Help for
more ways to install the license (click the "?" icon to from within the Keysight
License Manager to open the help file, or click Start > (All) Programs >Keysight License Manager > Keysight License Manager Help).
The install operation can take up to 40 seconds to complete.
When the license file is successfully installed, the installed transportable
licenses that are available are listed in the Keysight License Manager's main
license view area. Make sure your licensed options and features are shown.
4. After installing the license file, verify that the Options are licensed for use by the
Keysight 89600 software. Start the Keysight 89600 software, then open
Utilities > Licenses > Features (or Utilities > Licenses > Legacy Options for
89600 Software Quick Start Guide29
Page 30
Installing Licenses
Transportable License
legacy licenses) and verify the options are correctly licensed (Yes in the On
column).
"On" ColumnLicense Status
YesOption is licensed for use.
--Dash indicates that the license option has not been selected for
use by the VSA. To include an option, open the Select LicenseOptions system utility and select (check) the options that you
want to include in the VSA measurement capability (click Start >
(All) Programs > Keysight PathWave 89600 VSA <ReleaseVersion> > Select License Options. The VSA must be closed and
restarted to incorporate the changes.
NoOption is not licensed for use.
3089600 Software Quick Start Guide
Page 31
Using the VSA Online Help and Demos
Now that you have installed and licensed your Keysight 89600 software, it is time to
start using it. The best way to learn how to use the VSA software is to view the online
help and demo signal packages.
There are multiple ways to access the 89600 VSA help, as described on the following
pages in this chapter.
Using the VSA Online Help and Demos
31
Page 32
Using the VSA Online Help and Demos
Accessing Help
Accessing Help
Start menu
After installing the 89600 VSA software, you can click the Windows Start button > All
Programs > Keysight PathWave 89600 VSA <ReleaseVersion> > Help > VSA Help
to open the 89600 VSA help system.
Help menu
While the VSA software is running, click Help from the main menu then select one of
the following menu items:
This menu item…Does this…
Show HelpOpens the 89600 VSA help system in an external window.
Search HelpOpens the 89600 VSA help system to the search tab.
Dynamic HelpOpens the dynamic help panel. By default, dynamic help is shown in
a tool window that is docked to the right-hand side of the VSA main
window.
Getting StartedOpens a topic with links to information about getting started with
the 89600 VSA.
DemosOpens a list of demo signals that are provided with the VSA.
.NET API ReferenceOpens the 89600 VSA .NET API reference in a separate help win-
dow.
SCPIReferenceOpens the 89600 VSA SCPI reference in a separate help window.
Keysight 89600 VSA
website
Keysight VSA forumsOpens the Keysight VSA forums.
Technical SupportOpens the 89600 VSA Technical Support website.
About...Shows information about the VSA software, including what software
Opens the 89600 VSA website in the default web browser.
version is installed on your computer.
3289600 Software Quick Start Guide
Page 33
Using the VSA Online Help and Demos
Accessing Help
Dynamic help
Dynamic help is the quickest and easiest method to find help. To open the dynamic
help window, select Help > Dynamic Help. The current topic follows the user
interface item that currently has focus.
Help button on dialogs
You can access help for any dialog box by clicking the ? button in title bar of the dialog
box.
In the following illustration, clicking the Help button opens the VSA help for the
Format tab of the Digital Demod Properties dialog box.
F1 on the keyboard
You can access context-sensitive help by pressing the F1 key.
When you are viewing a dialog box, pressing F1 shows the same information as
clicking the ? button. The F1 help also works on menus and traces.
Pressing F1 while a menu item is highlighted opens context-sensitive help for that
menu item.
89600 Software Quick Start Guide33
Page 34
Using the VSA Online Help and Demos
Accessing Help
3489600 Software Quick Start Guide
Page 35
Using the VSA Online Help and Demos
Recalling a Demo Signal Package
Recalling a Demo Signal Package
Recalling a demo signal package is a good way to learn about the measurement
capabilities and features of the 89600 VSA. The 89600 VSA provides various demo
signal packages that include recorded signals, signal setup files, or Signal Studio
setup files, and a demo help topic.
To view the available demo signals, open the Demo and Recorded Signals help topic
(click Help > Demos).
To recall a demo:
1. Click File > Recall > Recall Demo.
2. In the Recall Demo dialog, browse to C:\Program Files\Keysight\89600 Soft-ware <ReleaseVersion>\89600 VSA Software\Help\Signals.
3. Select a Demo file of interest. For example, browse to AM FM PM, then select
XMITTER.htm.
4. Click Open. The VSA recalls the instrument setup (measurement state), loads
the recorded signal, and opens the corresponding help file in a separate window.
5. Read the Demo help file to learn about the recorded signal and the VSA setup
information.
6.
To start the measurement, click the Restart button () in the tool bar or click
Control > Restart.