Keysight 16861A, 16863A, 16862A, 16864A Installation And Quick Start Manual

Page 1
Keysight 16860 Series Portable Logic Analyzers
Installation/ Quick Start Guide
Page 2
Notices
CAUTION
WARNING
© Keysight Technologies 2016-2017
Manual Part Number
16860-97003
Edition
Second Edition, July 2017
Printed in Malaysia
Published By Keysight Technologies Plot No. CP-11, Sector-8 IMT Manesar, Gurgaon - 122051, India
Technical Assistance
ccr.keysight.com@keysight.com
www.keysight.com/find
Warranty
THE MATERIAL CONTAINED IN THIS DOCU­MENT IS PROVIDED "AS IS," AND IS SUB­JECT TO BEING CHANGED, WITHOUT NOTICE, IN FUTURE EDITIONS. FURTHER, TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, KEYSIGHT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED WITH REGARD TO THIS MANUAL AND ANY INFORMATION CONTAINED HEREIN, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MER­CHANTABILITY AND FITNESS FOR A PAR­TICULAR PURPOSE. KEYSIGHT SHALL NOT BE LIABLE FOR ERRORS OR FOR INCIDEN­TAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, USE, OR PERFORMANCE OF THIS DOCU­MENT OR ANY INFORMATION CONTAINED
HEREIN. SHOULD KEYSIGHT AND THE USER HAVE A SEPARATE WRITTEN AGREE­MENT WITH WARRANTY TERMS COVER­ING THE MATERIAL IN THIS DOCUMENT THAT CONFLICT WITH THESE TERMS, THE WARRANTY TERMS IN THE SEPARATE AGREEMENT WILL CONTROL.
Technology Licenses
The hardware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license.
U.S. Government Rights
The Software is "commercial computer software," as defined by Federal Acquisition Regulation ("FAR") 2.101. Pursuant to FAR
12.212 and 27.405-3 and Department of Defense FAR Supplement ("DFARS")
227.7202, the U.S. government acquires commercial computer software under the same terms by which the software is cus­tomarily provided to the public. Accord­ingly, Keysight provides the Software to U.S. government customers under its stan­dard commercial license, which is embod­ied in its End User License Agreement (EULA), a copy of which can be found at
http://www.key­sight.com/find/sweula. The license set
forth in the EULA represents the exclusive authority by which the U.S. government may use, modify, distribute, or disclose the Software. The EULA and the license set forth therein, does not require or permit, among other things, that Keysight: (1) Fur­nish technical information related to com­mercial computer software or commercial computer software documentation that is not customarily provided to the public; or (2) Relinquish to, or otherwise provide, the government rights in excess of these rights customarily provided to the public to use, modify, reproduce, release, perform, dis­play, or disclose commercial computer
software or commercial computer software documentation. No additional government requirements beyond those set forth in the EULA shall apply, except to the extent that those terms, rights, or licenses are explic­itly required from all providers of commer­cial computer software pursuant to the FAR and the DFARS and are set forth specifically in writing elsewhere in the EULA. Keysight shall be under no obligation to update, revise or otherwise modify the Software. With respect to any technical data as defined by FAR 2.101, pursuant to FAR
12.211 and 27.404.2 and DFARS 227.7102, the U.S. government acquires no greater than Limited Rights as defined in FAR
27.401 or DFAR 227.7103-5 (c), as appli­cable in any technical data. 52.227-14 (June 1987) or DFAR 252.227-7015 (b)(2) (November 1995), as applicable in any technical data.
Safety Notices
A CAUTION notice denotes a hazard. It calls attention to an operating procedure, prac­tice, or the like that, if not correctly per­formed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met.
A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indi­cated conditions are fully understood and met.
2 Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide
Page 3

16860 Series Logic Analyzers—At a Glance

Pods for Probe Inputs
Run/Stop Keys
USB 2.0 Ports (2)
Scroll Knob
Standby (Power) Button
Touch Screen On/Off Button
The Keysight Technologies 16860 series logic analyzers are portable logic analyzers that range from 34 to 136 logic acquisition channels, depending on the model.
Table 1 Model comparisons
Keysight model number 16861A 16862A 16863A 16864A
Logic acquisition channels 34 68 102 136

Features, Logic Acquisition

2 M to 400 M samples of memory depth per channel (depending on memory option), software upgradeable.
350 MHz or 700 MHz maximum state clock rate (depending on state speed option), software upgradeable.
Full Channel Timing Mode at 2.5 GHz sampling with 12.5 GHz Timing Zoom.
Half Channel Timing Mode at 5.0 GHz sampling with 12.5 GHz Timing Zoom
Quarter Channel Timing Mode at 10 GHz sampling with 12.5 GHz Timing Zoom
Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide 3
Eye scan (automatic threshold and sample position setup) feature.
Single-ended and differential probing support
Page 4

Features, Mainframe

Built-in 15 inch color touch screen with 1024 x 768 resolution
Removable hard drive
10/100/1000 Base-T LAN port
USB 2.0 ports (six total, two on front, four on back)
One PCI expansion slot
One PCI Express x1 expansion slot
Windows 10 installation
Windows 10 support has been added to the 16860-series logic analyzers and these are now shipped from the factory with Windows 10 operating system preinstalled. Earlier, Windows 7 operating system was preinstalled on these logic analyzers.
Keysight Logic and Protocol Analyzer application which takes the complexity out of making logic analyzer measurements. You can perform all operations directly from one window.

Supplied Accessories

USB mouse
•USB keyboard
Accessory pouch and power cord Snap the accessories pouch to the top of the 16860 series logic analyzer. Use it to
store probe leads, accessories, or manuals. Use the tie-down straps under the flap to conveniently hold pod cables not in use or during transport.

Optional Accessories

•Probes

Front Panel

Refer to the online help in the logic and protocol analyzer software for information on using the analyzer.

Rear Panel

Before you turn on the system, connect your mouse and keyboard to the 16860 Series logic analyzer rear panel.

16860-Series Logic Analyzer Dimensions

All dimensions given below are in Millimeters (mm).
4 Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide
Page 5
Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide 5
Page 6

In This Guide…

This guide describes how to set up, use, and update your 16860 series logic analyzer. It also contains information on solving problems and additional safety information.

1 First-Time Set Up

This chapter describes the steps in setting up the logic analyzer for the first time.

2 Getting Started with the Logic Analyzer

This chapter describes some basic features of the logic analyzer and tells you where to find more information on using the logic analyzer.

3 Updating the Logic Analyzer

This chapter describes how to change your logic analyzer’s network and Windows Firewall settings. It also describes how to get and install software updates.

4 Solving Problems

This chapter describes the logic analyzer’s built-in self tests and recovering system software.
5Safety Notices
This chapter contains additional safety information.
6 Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide
Page 7

Contents

1 First-Time Set Up
2 Getting Started with the Logic Analyzer
Proper Cooling 12
First-Time Set Up Considerations 13
Determine Whether the Instrument will be Connected to the Network
Get Network Setup Information 13
First-Time Set Up On 16860 Series Logic Analyzers 14
Additional First-Time Setup Steps 16
Establishing an Administrator Account (recommended for standalone and networked instruments)
Protecting the Instrument’s Operating System 16
13
16
Contents
Probing 18
Making a Measurement 19
Snap to Edge Markers 21
Left-Click Menus 22
Tree Structure Bus/Signal Names 22
Offline Analysis 23
Marker Overview 23
Tool Tips 24
Trigger History 25
Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide 7
Page 8
Contents
To close the Windows OS and place the system in a standby state 26
Using the Windows Shutdown 26 Using a Short Press of the Power Button 26 Using a Long Press of the Power Button 27 Unplugging the Power Cord or Power Loss 27
Specifications and Characteristics 28
3 Updating the Logic Analyzer
Changing Network Settings 32
Changing Windows Firewall Settings 33
To give other applications/ports access through the firewall 33 To restore the logic analyzer firewall defaults 33
Software Installation and Upgrades 35
Keysight Logic and Protocol Analyzer Software 35 Optional Products 35
4 Solving Problems
Running Self-Tests 38
If the logic analyzer powers itself down 40
If the Power LEDs do not come on 40
If you get a registry error and the system won’t boot 40
If there are network connection problems 41
If there are touch screen problems 42
Using the System Recovery Software 45
Contacting Keysight Service/Support 49
5 Safety Notices
Warnings 52
8 Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide
Page 9
Index
Contents
To clean the instrument 54
Safety Symbols 55
Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide 9
Page 10
Contents
10 Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide
Page 11
Keysight 16860 Series Portable Logic Analyzers
Installation/Quick Start Guide

1 First-Time Set Up

Proper Cooling / 12 First-Time Set Up Considerations / 13 First-Time Set Up On 16860 Series Logic Analyzers / 14 Additional First-Time Setup Steps / 16
Page 12
1 First-Time Set Up
NOTE

Proper Cooling

Allow at least 5 cm (2 inches) of space between instruments for proper cooling.
This instrument requires 100-120VAC 50/60/400Hz & 100-240VAC 50/60Hz mains capable of supplying 325 watts. Do not apply more than 25 volts to any Probe Adapter signal line. Do not apply more than 5.5 volts to the BNC Trigger In or Trigger Out.
This instrument is intended for office and lab use only in:
- Temperature range of 5-40°C
- Altitude upto 4000 m
- Maximum Humidity 90% non-condensing at +40°C.
12 Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide
Page 13

First-Time Set Up Considerations

NOTE
Determine Whether the Instrument will be Connected to the Network
If you plan to use COM automation to programmatically control a logic analyzer from a remote computer, be aware that the remote computer and the logic analyzer must both have the same kind of network membership; that is, they must both be members of a "Workgroup", or they must both be members of a "Domain". This is due to the security requirements of Distributed COM.
Standalone
You are going to use the logic analyzer as a standalone instrument (no LAN connection). Printing requires a printer attached to the logic analyzer, sharing files is done via USB flash drive or floppy disk.
Connected to a Network
If you require the ability to print, share files, remotely control the logic analyzer, etc. over the network, you need to either join a workgroup or domain.
First-Time Set Up 1
Get Network Setup Information
For networking, find out whether the network that your instrument will be connected to uses the Microsoft Work group model or Microsoft Domain model. In order for your instrument to perform tasks over the network (print, transfer files, etc.) your instrument must be configured appropriately for the networking model in use at your site.
Information you may require to complete your network configuration may include, but is not limited to:
• The Workgroup or Domain name.
• Methodology for assigning IP addresses at your site (for example, DHCP).
• Domain Name Service (DNS).
Other network information that may be readily available from your network administrator.
Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide 13
Page 14
1 First-Time Set Up

First-Time Set Up On 16860 Series Logic Analyzers

The first time you turn on a 16860 series logic analyzer (shipped with Windows 10 installation), you are automatically logged on to the system using the Administrator account and the Windows 10 desktop is displayed.
Note: Windows 10 support has been added to the 16860-series logic analyzers and these are now shipped from the factory with Windows 10 operating system preinstalled. Earlier, Windows 7 operating system was preinstalled on these logic analyzers. I
Once you are logged on to the system, you must set the following logic analyzer configurations based on how you want to use your logic analyzer. You use the standard Windows 10 procedures to set these configurations.
Table 2 Logic Analyzer Configurations on a 16860 Series Logic Analyzer with Windows 10
Configuration Task Logic Analyzer Usage
Standalone (No LAN) Workgroup Domain
Protect your instrument’s PC N/A Turn on Automatic Updates Turn on Automatic Updates
Specify computer name If your organization has a standard naming scheme, use that scheme. Otherwise, choose a descriptive
Specify the administrator password Keysight recommends entering an administrator password for administrator accounts. See page 16 for
Specify the domain name (if applicable) No
Enter your domain settings. N/A N/A Enter the name/password of the
Configure connectivity to the Internet N/A N/A Choose the appropriate Internet
Set up a high-speed connection N/A N/A Enter either the fixed IP/DNS
name (less than 15 characters)
actions that require administrator accounts.
(Is given WORKGROUP membership)
Installation
No (Is given WORKGROUP membership)
Yes Enter the domain name the logic analyzer will log onto.
user who can add the logic analyzer to the domain.
connectivity.
assigned by your network administrator or select “Obtain Automatically”.
14 Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide
Page 15
Configuration Task Logic Analyzer Usage
Standalone (No LAN) Workgroup Domain
First-Time Set Up 1
Determine if you want to connect the instrument’s PC to the Internet directly or through a network.
Register with Microsoft The 16860 series of Logic Analyzers have the Windows 10 operating system already enabled to run.
Specify users for the instrument’s PC You can add multiple users with administrator permissions to allow these users to use the logic analyzer.
N/A Keysight does not support
connecting to the Internet through a modem directly connected to the logic analyzer.
This registration is to allow Microsoft to contact you.
N/A
Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide 15
Page 16
1 First-Time Set Up

Additional First-Time Setup Steps

Establishing an Administrator Account (recommended for standalone and networked instru­ments)
Protecting the Instrument’s Operating System
Keysight recommends that you set up an Administrator account for your logic analyzer. You have to be logged in to the Administrator account to do the following:
• Install most software (applies whether the instrument is networked or standalone).
• Change the workgroup.
• Perform "Windows Updates".
• Change firewall settings.
Microsoft recommends the following three steps to ensure the instrument's PC is protected.
1 Use an Internet firewall. 2 Get operating system updates. 3 Use up-to-date antivirus software.
16 Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide
Page 17
Keysight 16860 Series Portable Logic Analyzers
Installation/Quick Start Guide
2 Getting Started with
the Logic Analyzer
Probing / 18 Making a Measurement / 19 Snap to Edge Markers / 21 Left-Click Menus / 22 Tree Structure Bus/Signal Names / 22 Offline Analysis / 23 Marker Overview / 23 Tool Tips / 24 Trigger History / 25 Specifications and Characteristics / 28
Page 18
2 Getting Started with the Logic Analyzer

Probing

Probing is the key to effective and efficient use of logic analyzers. Keysight Technologies offers a wide variety of probing accessories that support general-purpose and application-specific measurement needs. We provide reliable, electrically and mechanically unobtrusive probes that make it easy to connect your Keysight logic analyzer to your system under test. For more information on Keysight probes:
• See the quick reference card that came with your logic analyzer for an overview of probing solutions.
•Go to www.keysight.com/find/logic_analyzer_probes for the most up-to-date information on probe compatibility with a given logic analyzer and purchasing information.
•Go to www.keysight.com and search for Probing Solutions for Logic
Analysis Systems (publication 5968-4632E) for a catalog of detailed
probing information.
To connect and set up a probe, follow the instructions that came with the probe.
18 Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide
Page 19

Making a Measurement

Getting Started with the Logic Analyzer 2
1 Start up the logic analyzer, connect to your target system, and select
Setup>Bus/Signal.
2 Assign buses and signals and click OK.
Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide 19
Page 20
2 Getting Started with the Logic Analyzer
3 Enter a trigger value in the Waveform View.
4 Acquire and view data.
20 Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide
Page 21

Snap to Edge Markers

Getting Started with the Logic Analyzer 2
You can set the markers to jump to the nearest edge of a waveform. A yellow target will show which edge the marker will jump to.
Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide 21
Page 22
2 Getting Started with the Logic Analyzer

Left-Click Menus

Drag a box around parts of the data. When you release the mouse button, a menu appears.

Tree Structure Bus/Signal Names

Show individual signals in buses by clicking on the + to expand.
22 Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide
Page 23

Offline Analysis

Marker Overview

Getting Started with the Logic Analyzer 2
Install the Keysight Logic and Protocol Analyzer application on another Windows 7/10 or Windows 2000 computer and you can analyze data without the 16860 Series logic analyzer.
1 Follow the instructions in “Software Installation and Upgrades" on
page 35 to load the 16860 Series logic analyzer software on your PC. 2 Acquire a trace with the logic analyzer. 3 Save a configuration file with data. 4 Copy the file to the PC being used for offline analysis. 5From the Keysight Logic and Protocol Analyzer application software on
your PC, open the configuration file.
The marker overview display shows marker locations within the data and the part of data currently being displayed.
Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide 23
Page 24
2 Getting Started with the Logic Analyzer

Tool Tips

Pause the cursor over a tool Icon and a “Tool Tip Window” will appear.
24 Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide
Page 25

Trigger History

Getting Started with the Logic Analyzer 2
Save and recall trigger settings.
Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide 25
Page 26
2 Getting Started with the Logic Analyzer
NOTE

To close the Windows OS and place the system in a standby state

You can place the logic analyzer in a standby state by using either Windows Shutdown or a short press of the power button on the front panel of the logic analyzer.
When powering off the logic analyzer, wait until the fans stop turning (about 15 seconds) before turning the logic analyzer back on. This ensures that internal circuitry restarts in a known state.
Using the Windows Shutdown
On the logic analyzer desktop click Start>Shut Down or if you are running remote desktop, click Start>Windows Security>Shut Down. This:
• Closes all programs that are running.
• Writes all data to the disk.
• Turns off the power supply except for the motherboard standby power.
• If the system is unplugged while it is off and then plugged back in, the
system will not power on until the power button is pressed.
Using a Short Press of the Power Button
Pressing the power button on the logic analyzer for a short time (less than 2 seconds):
• Closes all programs that are running.
• Writes all data to the disk.
• Turns off the power supply except for the motherboard standby power.
If the power button on the Remote Desktop is depressed for a short time (less than 2 seconds or so), a message on the logic analyzer screen (not on the remote desktop) will pop up asking if you really want to power down. Clicking the 'yes' button results in the above events. Clicking 'no' will prevent the shutdown. Not answering the dialog box (clicking neither "Yes" nor "No") will have no effect. Further short presses on the power button will have no effect.
26 Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide
Page 27
Using a Long Press of the Power Button
CAUTION
CAUTION
NOTE
Only use a long press of the power button when the logic analyzer is unresponsive to Windows Shutdown or a short press of the power button.
Pressing the power button for more than 4 seconds will place the system in a standby state abruptly:
• Programs that are running will not be properly shut down. Any data that
has not been written to the disk will be lost.
• The power supply will be turned off except for the motherboard standby
power.
• If the system is unplugged while it is off and then plugged back in, the
system will not power on until the power button is pressed
Unplugging the Power Cord or Power Loss
Only unplug the power cord when the logic analyzer is unresponsive to all other methods for powering off the system.
Getting Started with the Logic Analyzer 2
Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide 27
The main power cord is to be used as the system disconnecting device.It disconnects the mains circuit from the mains supply. When the system is plugged back in, it will power up and boot into Windows.
Position the logic analyzer such that it is not difficult to unplug the main power cord.
Page 28
2 Getting Started with the Logic Analyzer
CAUTION
CAUTION
CAUTION

Specifications and Characteristics

This product is designed for use in Installation Category II and Pollution Degree 2 environment.
This instrument has auto-ranging line voltage input. Ensure that the supply voltage is within the specified range and voltage fluctuations do not to exceed 10 percent of the nominal supply voltage.
Do not apply more than 5.5 volts to Trigger In BNC or Trigger Out BNC.
The following electrical and operating characteristics are not specifications, but are typical operating characteristics for the Keysight 16860 series logic analyzers.
28 Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide
Electrical Characteristics
Power Requirements 16861A, 16862A, 16863A, and 16864A: 00-120VAC 50/60/400Hz &100-240VAC
50/60Hz mains capable of supplying 325 watts. CAT II (Line voltage in appliance and to wall outlet). Installation category II, Pollution degree 2.
Environmental Characteristics (Operating)
Temperature Instrument: 5° C to 40° C
Altitude 4000 m
Humidity Maximum 90% Relative humidity, non-condensing
Intended for use in an indoor lab environment
Page 29
Getting Started with the Logic Analyzer 2
More specifications and characteristics for your instrument and measurement modules are in the on-line help. To find these, go to:
1Click Help>Help Topics.
Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide 29
Page 30
2 Getting Started with the Logic Analyzer
2Click the Logic Analyzer - Specifications and Characteristics help book.
30 Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide
Page 31
Keysight 16860 Series Portable Logic Analyzers
Installation/Quick Start Guide
3 Updating the Logic
Analyzer
Changing Network Settings / 32 Changing Windows Firewall Settings / 33 Software Installation and Upgrades / 35
Page 32
3 Updating the Logic Analyzer

Changing Network Settings

On Windows 7
To make network changes after the first-time power up:
The following steps are applicable for a logic analysis system with Windows 7 operating system:
• To change from a workgroup to a domain or vice versa, click Computer
and select Properties. Click the Change Settings link in the Computer name, domain and workgroup settings section. Then select the Computer Name tab and click Change.
• To change network connection properties, click Start>Control
Panel>Network and Sharing Center. Select the connection you want to change and then set the properties of this connection.
For more information on changing network settings, refer to the Windows 7 online help.
On Windows 10
To make network changes after the first-time power up:
The following steps are applicable for a logic analysis system with Windows 10 operating system:
• To change from a workgroup to a domain or vice versa, click Control
Panel from the Startup menu, and then click System. Click the Change Settings link in the Computer name, domain and workgroup settings section.
Then select the Computer Name tab and click Change.
• To change network connection properties, click Start>Control
Panel>Network and Sharing Center. Select the connection you want to change and then set the properties of this connection.
For more information on changing network settings, refer to the Windows 10 online help.
32 Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide
Page 33

Changing Windows Firewall Settings

NOTE
When 16860 series logic analyzers are shipped from the factory, the Windows Firewall is enabled and set up with the exceptions required by the logic analyzer.
To give other applications/ports access through the firewall
For example, you may need to change firewall settings in order to:
• Use NetOp to remotely control the logic analyzer.
• Use RealVNC to remotely control the logic analyzer.
To change firewall settings on Windows OS to give other applications/ports access:
1 From the Windows Start menu, choose Start > Control Panel > System and
Security > Windows Firewall. 2Click the Allow an app or a feature through Windows firewall link. 3 The list of allowed programs and features is displayed. If the required
program or service is listed, check its box to enable it; otherwise, click
Allow another program... to give unlisted programs permission to
penetrate the firewall.
Refer to the application’s documentation for more information on port numbers or other firewall setup information.
Updating the Logic Analyzer 3
Note that there are separate Windows Firewall profiles: Domain for when the computer has domain membership, and Standard for when the computer has workgroup membership. If you change the type of membership, any changes you made to the Windows Firewall settings will have to be made again.
To restore the logic analyzer firewall defaults
1 From the Windows Start menu, choose Start > Control Panel > System
Security. 2Click the Windows Firewall link. 3Click Restore defaults in the left pane of the window. 4 Again click Restore defaults. 5 Uninstall and then reinstall the Logic Analyzer software from
www.keysight.com/find/lpa-sw-download.
The logic analyzer firewall defaults enable the following exceptions:
Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide 33
Page 34
3 Updating the Logic Analyzer
NOTE
Note that there are separate Windows Firewall profiles: Domain for when the computer has domain membership, and Standard for when the computer has workgroup membership. When you restore the logic analyzer firewall defaults, the defaults for both profiles are restored.
• Keysight Logic Analysis Application program.
• Keysight Logic Analysis Service program.
• File and Printer Sharing.
• Microsoft RPC Endport Mapper TCP port.
• Remote Desktop service.
• Web Server (HTTP) port.
The logic analyzer firewall defaults also enable the following ICMP (Internet Control Message Protocol) settings:
• Allow incoming echo request.
• Allow outgoing destination unreachable.
• Allow outgoing time exceeded.
34 Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide
Page 35

Software Installation and Upgrades

Keysight Logic and Protocol Analyzer Software
The Keysight 16860 Series logic analyzers are shipped with software already installed, including any licensed optional products that you may have purchased. The licensing process (described below) has been performed and the (*.lic) license file is in place.
To upgrade/reinstall the logic and protocol analyzer software or to install this software onto your PC for offline processing:
• Download the Logic and Protocol Analyzer software from
http://www.keysight.com/find/lpa-sw-download and then install the
software using the downloaded file. These systems are not shipped with an application CD. You need the Keysight Logic and Protocol Analyzer software version 6.30 or later for these systems.
To be notified when software upgrades are available for downloading from the web, please sign up for e-mail notifications at:
www.keysight.com/find/emailupdates
Optional Products
If applicable, follow the instructions on the entitlement certificate that came with your purchase to enable the optional tool.
Updating the Logic Analyzer 3
Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide 35
Page 36
3 Updating the Logic Analyzer
36 Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide
Page 37
Keysight 16860 Series Portable Logic Analyzers
Installation/Quick Start Guide

4 Solving Problems

Running Self-Tests / 38 If the logic analyzer powers itself down / 40 If the Power LEDs do not come on / 40 If you get a registry error and the system won’t boot / 40 If there are network connection problems / 41 If there are touch screen problems / 42 Using the System Recovery Software / 45 Contacting Keysight Service/Support / 49
Page 38
4 Solving Problems

Running Self-Tests

1 In the Keysight Logic and Protocol Analyzer application, click Help>Self
Tes t.
2In the Analysis System Self Test dialog, double-click the test you want to
run.
38 Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide
Page 39
Solving Problems 4
Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide 39
Page 40
4 Solving Problems

If the logic analyzer powers itself down

If the logic analyzer warns you it is powering down before it powers down, the dialog will describe the problem (such as a fan/overtemp problem). If the logic analyzer just powers down, it is likely a power supply problem.

If the Power LEDs do not come on

If the lights do not come on and if the system powers up momentarily when you plug it in, make sure the power button hasn't become jammed or stuck in the pushed in position.

If you get a registry error and the system won’t boot

When powered off unexpectedly (for example, with a long press of the power button or a power loss), Windows may not flush all system information to disk and is vulnerable to problems. When you power back on you may get a "Registry Error" and the system won't boot. If this happens you will need to restore the system software using the recovery process. This process overwrites all the user data and restores the system back to the original condition in which it was shipped. Refer to the topic
“Using the System Recovery Software" on page 45 to know more about
this process.
It is best to keep regular backups of your data and use proper power down procedures. If you have data that was not backed up that you need to try to save:
1 Physically remove the disk drive. 2 Mount it under another Windows 10 system. 3 Move the data to the boot disk until you can restore the operating
system.
40 Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide
Page 41

If there are network connection problems

See the “Network Troubleshooting Guide” topic in the Keysight Logic Analyzer application’s online help. Briefly:
• The Windows Firewall must be set to allow access to the “Keysight
Logic Analysis” service in order to use remote connections (see “To
restore the logic analyzer firewall defaults" on page 33).
• The Windows Firewall must be set to respond to the following ICMP
(Internet Control Message Protocol) requests in order to use remote connections:
Allow incoming echo requests.
Allow outgoing destination unreachable.
Allow outgoing time exceeded.
(See “To restore the logic analyzer firewall defaults" on page 33.)
• The link activity light must be on; If these LEDs are not on, the LAN
segment may be dead.
• If connecting two logic analysis systems directly together (that is, no
hub or switch between them), make sure you are using a special cross-over cable.
If your IP address is in the same subnet as a working computer’s (use “ipconfig /all | more” to view IP addresses on machine in question), it is possible that your network administrators have denied access to any resources if the computer is not in the domain. In this case, you need to add the computer (logic analysis system) to the domain.
Solving Problems 4
Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide 41
Page 42
4 Solving Problems

If there are touch screen problems

If you observe the following touch screen problems:
• If the Touch Off button on the instrument’s front panel doesn’t work.
• If there are problems with the right-click functionality on the touch
screen.
• If the accuracy of touch locations is off.
You may be able to calibrate the touch screen to fix the problem by following the procedures described below for 16860 series of logic analyzers.
1 From the Windows Start menu, choose Start>All Programs>Keysight Logic
Analyzer>Utilities>Touch Screen>Touch Screen Calibration and Settings. 2 In the Microchip TSHARC Control Panel dialog, select the Calibration
tab.
42 Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide
Page 43
Solving Problems 4
3 By default, the number of points is set to 4 and the Inset is set at
20.0%. 4Click Begin Calibration. 5 If you want to enable the right-click functionality on the touch screen,
select the Click Settings tab and then select the Enable Right-Click checkbox. You can also set the area on the touch screen on which you want to enable the right-click functionality.
Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide 43
Page 44
4 Solving Problems
If calibrating the touch screen doesn’t fix the problem, see “Contacting
Keysight Service/Support" on page 49.
44 Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide
Page 45

Using the System Recovery Software

NOTE
Restoring your system software might be necessary for the following reasons:
• Hard drive (SSD) failure.
• Virus in the system or unstable system.
• Intentional disk clean - for example if you are passing the system to
another team or returning it to a rental company and you do not want any data left on it.
The 16860 series of Logic Analyzers are now shipped with the Windows 10 operating system preinstalled. Earlier, Windows 7 was preinstalled on these logic analyzers.
In addition, 16860 series of Logic Analyzers also have the Keysight Logic Analyzer software version 6.30 or later preinstalled.
These systems do not have any recovery CD or DVD in their shipment. If you need to restore the logic analysis system software, you run the recovery process on the hard drive (SSD) of the system. This recovery process uses the hidden partition on the hard drive to restore the hard disk drive back to its original state in which it was shipped. When you run this process, the recovered hard disk drive contains:
• the Windows 10 operating system
• the version of the Logic and Protocol Analyzer software which was
installed when the system was originally shipped and not the latest or upgraded version of the software that might be available at the time of system recovery.
• the license files of any licensed optional products that you had
purchased with the Logic Analyzer and that were installed when the system was originally shipped.
Solving Problems 4
When you run the recovery process, the software licensing Host ID of your logic analyzer may change. If this happens, the restored license files will not work with the new host ID and you will need rehosted license files. To get these files, you can contact your nearest Keysight sales/service office. To locate a sales or service office, go to
www.keysight.com/find/contactus.
Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide 45
Page 46
4 Solving Problems
CAUTION
Running the recovery process reformats your logic analyzer’s hard disk drive to the state in which it was originally shipped to you. All user data files and programs are overwritten when the recovery process runs. Therefore, save your data to a CD or to another machine before you start recovering the system software.
To run the recovery process
1 Shut down and then restart your Logic Analyzer.
While booting up, the Logic Analyzer displays the Windows Boot Manager screen. This screen provides you the following options:
Microsoft Windows 7 or 10 (as per the installed operating system) -
This is the default selected option. This option starts the Logic Analyzer with the installed Windows operating system. This is the normal startup of the system.
Keysight Recovery system - You should select this option when you
want to restore/repair your Logic Analyzer software by running the Keysight recovery process.
2 After a few seconds, Logic Analyzer automatically starts with the option
selected in the Windows Boot Manager. Select the Keysight Recovery
46 Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide
Page 47
Solving Problems 4
system option in the Windows Boot Manager screen using the arrow keys and then press Enter.
The recovery process starts preparing the system for recovery and displays the following screen with options to choose. You can enter:
1 to run Check Disk on the Logic Analyzer’s hard disk drive. If the
recovery process encounters any problems while running Check Disk, it reports these problems else it returns to the Keysight Recovery system prompt on completion of Check Disk.
2 to restore your Logic Analyzer software back to its original state in
which it was shipped.
3 to view a document that provides information on the recovery
process.
4 to repair the Logic Analysis system hard disk drive.
5 to exit the recovery process and restart the Logic Analyzer in the
normal mode.
3 Select the second option in the above screen by entering 2 in the text
box and clicking OK.
4 A warning message is displayed stating that the recovery process
overwrites the data on C: drive. If you want to save your data to a CD or to another machine before you proceed further, then exit the recovery process and save your data. Else, click OK to proceed with the recovery process.
Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide 47
Page 48
4 Solving Problems
The recovery process starts.
If the recovery process is able to restore the system software successfully, then the following screen is displayed.
5Click OK to proceed. You Logic Analysis system now reboots to
Windows 10.
6 The Windows Boot Manager screen is displayed with Microsoft Windows
10 as the default selection. The system automatically starts with this
48 Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide
Page 49
Solving Problems 4
NOTE
default selection. Alternatively, you can press Enter to proceed with the default selection.
There are situations when you are not able to run the recovery process, (for instance, when the hard disk drive of your system fails) or when running the recovery process does not recover your system software. In such situations, you can send your Logic Analysis system for hard disk repair/replacement to Keysight. Alternatively, you can contact your nearest Keysight sales/service office. To locate a sales or service office, go to
www.keysight.com/find/contactus.

Contacting Keysight Service/Support

To locate a sales or service office near you, go to:
http://www.keysight.com/find/contactus
Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide 49
Page 50
4 Solving Problems
50 Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide
Page 51
Keysight 16860 Series Portable Logic Analyzers
Installation/Quick Start Guide

5 Safety Notices

Warnings / 52 To clean the instrument / 54 Safety Symbols / 55
This apparatus has been designed and tested in accordance with IEC Publication 1010, Safety Requirements for Measuring Apparatus, and has been supplied in a safe condition. This is a Safety Class I instrument (provided with terminal for protective earthing). Before applying power, verify that the correct safety precautions are taken (see the following warnings). In addition, note the external markings on the instrument that are described under "Safety Symbols."
Page 52
5 Safety Notices

Warnings

• Before turning on the instrument, you must connect the protective
earth terminal of the instrument to the protective conductor of the (mains) power cord. The mains plug shall only be inserted in a socket outlet provided with a protective earth contact. You must not negate the protective action by using an extension cord (power cable) without a protective conductor (grounding). Grounding one conductor of a two-conductor outlet is not sufficient protection.
• Only fuses with the required rated current, voltage, and specified type
(normal blow, time delay, etc.) should be used. Do not use repaired fuses or short-circuited fuse holders. To do so could cause a shock or fire hazard.
• Do not use this instrument with a power cord other than the one
provided by Keysight. Other power cords may not have appropriate ratings.
• If you energize this instrument by an auto transformer (for voltage
reduction or mains isolation), the common terminal must be connected to the earth terminal of the power source.
• Whenever it is likely that the ground protection is impaired, you must
make the instrument inoperative and secure it against any unintended operation.
• Service instructions are for trained service personnel. To avoid
dangerous electric shock, do not perform any service unless qualified to do so. Do not attempt internal service or adjustment unless another person, capable of rendering first aid and resuscitation, is present.
• Do not install substitute parts or perform any unauthorized
modification to the instrument.
• Capacitors inside the instrument may retain a charge even if the
instrument is disconnected from its source of supply.
• Do not operate the instrument in the presence of flammable gasses or
fumes. Operation of any electrical instrument in such an environment constitutes a definite safety hazard.
• Do not use the instrument in a manner not specified by the
manufacturer.
• To optimize your comfort and productivity, it is important that you set
up your work area correctly and use your equipment properly. Refer to the Working in Comfort topic in the online help or set-up and use recommendations
• Position equipment so that it is not difficult to disconnect the power
cord.
52 Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide
Page 53
Safety Notices 5
• If incorporated into a system, the safety of the system is the
responsibility of the system installer. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. See "For Your Safety" booklet publication number 9320-6797. Use only the power cord supplied with the instrument.
Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide 53
Page 54
5 Safety Notices
WARNING

To clean the instrument

To prevent an electrical shock, disconnect the logic analyzer from mains before cleaning. Use a dry cloth or one slightly dampened with water to clean the external case parts. Do not attempt to clean internally.
If the instrument requires cleaning: 1 Remove power from the instrument. 2 Clean the external surfaces of the instrument with a soft cloth
dampened with water.
3 Make sure that the instrument is completely dry before reconnecting it
to a power source.
54 Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide
Page 55

Safety Symbols

!
Safety Notices 5
Instruction manual symbol: the product is marked with this symbol when it is necessary for you to refer to the instruction manual in order to protect against damage to the product.
Indicates hazardous voltages and potential for electrical shock.
Earth terminal symbol: Used to indicate a circuit common connected to grounded chassis.
The C-tick mark is a registered trademark of the Spectrum Management Agency of Australia. This signifies compliance with the Australia EMC Framework regulations under the terms of the Radio Communication Act of 1992.
CE compliance marking to the EU Safety and EMC Directives.
ISM GRP-1A classification according to the international EMC standard.
ICES/NMB-001 compliance marking to the Canadian EMC standard.
KC certification mark to demonstrate compliance with the South Korean EMC requirements.
South Korean Class A EMC declaration:
This equipment is Class A suitable for professional use and is for use in electromagnetic environments outside of the home.
CSA is the Canadian certification mark to demonstrate compliance with the Safety requirements.
Notice for the European Community: This product complies with the WEEE Directive (2002/96/EC) marking requirements. The affixed label indicates that you must not discard this electrical/electronic product in domestic
Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide 55
Page 56
5 Safety Notices
household waste. Product Category: With reference to the equipment types in the WEEE Directive Annex I, this product is classed as a “Monitoring and Control instrumentation” product.
Do not dispose in domestic household waste. To return unwanted products, contact your local Keysight office or get more information from
www.keysight.com/environment/product.
56 Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide
Page 57

Index

A
administrator, 13 administrator account, 16
C
caution
electrostatic discharge, 27
CD
product software, 35 change network settings, 32 characteristics, 29 Check Disk, 47 contact information, 49
D
debugging network, 41 dimensions, 4 disk
clean/reformat, 45 domain, 13
E
electrostatic discharge, 27
F
firewall
changing settings, 16, 33
G
grounding, 27
H
hard drive, 45
I
ICMP settings, 34 install
software, 35
inverse assemblers, 35
K
Keysight web
service/support, 49
L
LEDs, 40
N
network
adding logic analyzer, 13 connection decision, 13
debugging, 41 network connection problems, 41 network settings, 32
O
optional tools, 35
R
recovery procedures, 45 recovery process, 45 registry error, 40 restoring system, 45
running self tests, 38
S
self tests, 38 service
contacting Keysight, 49 ground modules, 27
software
add-in, 35 installation, 13, 16, 35
updating, 35 specifications, 29 standalone operation, 13 system
recovery, 45
software, 35
T
tools, optional, 35 touchscreen problems, 42
U
update software, 35
W
windows
power problems, 40
updates, 16 Windows Boot Manager, 46 Windows Firewall settings
changing, 33 workgroup, 13
changing, 16
Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide 57
Page 58
Index
58 Keysight 16860 Series Portable Logic Analyzers Installation/Quick Start Guide