Keysight 11636A Operating And Service Manual

Keysight 11636A 50 Ohm Type-N Power Divider DC to 18 GHz
Operating and Service Manual
Notices
CAUTION
WARNING
Copyright Notice
any form or by any means (including electronic storage and retrieval or translation into a for­eign language) without prior agreement and written consent from Keysight Technologies as governed by United States and international copyright laws.
Manual Part Number
11636-90004
Edition
Edition 2, January 17, 2019
Printed in:
Printed in Malaysia
Published by:
Keysight Technologies Bayan Lepas Free Industrial Zone, 11900 Penang, Malaysia
Technology Licenses
The hard ware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license.
Declaration of Conformity
Declarations of Conformity for this product and for other Keysight products may be down­loaded from the Web. Go to http://www.key-
sight.com/go/conformity. You can then search
by product number to find the latest Declara­tion of Conformity.
U.S. Government Rights
The Software is “commercial computer soft­ware,” as defined by Federal Acquisition Regu­lation (“FAR”) 2.101. Pursuant to FAR 12.212 and 27.405-3 and Department of Defense FAR Supplement (“DFARS”) 227.7202, the U.S. government acquires commercial computer software under the same terms by which the software is customarily provided to the public. Accordingly, Keysight provides the Software to U.S. government customers under its standard commercial license, which is embodied in its End User License Agreement (EULA), a copy of which can be found at http://www.key-
sight.com/find/sweula. The license set forth in
the EULA represents the exclusive authority by which the U.S. government may use, modify, distribute, or disclose the Software. The EULA and the license set forth therein, does not require or permit, among other things, that Keysight: (1) Furnish technical information related to commercial computer software or commercial computer software documenta­tion that is not customarily provided to the public; or (2) Relinquish to, or otherwise pro­vide, the government rights in excess of these rights customarily provided to the public to use, modify, reproduce, release, perform, d is­play, or disclose commercial computer soft­ware or commercial computer software documentation. No additional government requirements beyond those set forth in the EULA shall apply, except to the extent that those terms, rights, or licenses are explicitly required from all providers of commercial computer software pursuant to the FAR and the DFARS and are set forth specifically in writing elsewhere in the EULA. Keysight shall be under no obligation to update, revise or otherwise modify the Software. With respect to any technical data as defined by FAR 2.101, pursuant to FAR 12.211 and 27.404.2 and DFARS 227.7102, the U.S. government acquires no greater than Limited Rights as defined in FAR 27.401 or DFAR 227.7103-5 (c), as applicable in any technical data.
Warranty
THE MATERIAL CONTAINED IN THIS DOCU­MENT IS PROVIDED “AS IS,” AND IS SUBJECT TO BEING CHANGED, WITHOUT NOTICE, IN FUTURE EDITIONS. FURTHER, TO THE MAXI­MUM EXTENT PERMITTED BY APPLICABLE LAW, KEYSIGHT DISCLAIMS ALL WARRAN­TIES, EITHER EXPRESS OR IMPLIED, WITH REGARD TO THIS MANUAL AND ANY INFOR­MATION CONTAINED HEREIN, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRAN­TIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. KEYSIGHT SHALL NOT BE LIABLE FOR ERRORS OR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, USE, OR PERFORMANCE OF THIS DOCU­MENT OR OF ANY INFORMATION CONTAINED HEREIN. SHOULD KEYSIGHT AND THE USER HAVE A SEPARATE WRITTEN AGREEMENT WITH WARRANTY TERMS COVERING THE MATERIAL IN THIS DOCUMENT THAT CON­FLICT WITH THESE TERMS, THE WARRANTY TERMS IN THE SEPARATE AGREEMENT SHALL CONTROL.
Safety Information
A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not pro­ceed beyond a CAUTION notice until the indi­cated conditions are fully understood and met.
A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met.
2 Keysight 11636A Operating and Service Manual

Safety Symbols

The following symbols on the instrument and in the documentation indicate precautions which must be taken to maintain safe operation of the instrument.
When you see this symbol on your instrument, you should refer to the instrument’s
instruction manual for important information.
This symbol indicates hazardous voltages.
The laser radiation symbol is marked on products that have a laser output.
This symbol indicates that the power line switch is ON.

Regulatory Markings

The CE mark is a registered trademark of the European Community. This CE mark shows that the product complies with all the relevant European Legal Directives.
This text indicates that the instrument is an Industrial Scientific and Medical Group 1 Class A product (CISPER 11, Clause 4).
This symbol indicates that the instrument requires alternating current (ac) input.
This symbol indicates that the power line switch is OFF or in STANDBY position.
The CSA mark is a registered trademark of the Canadian Standards Association.
Keysight 11636A Operating and Service Manual 3

Waste Electrical and Electronic Equipment (WEEE) Directive

This instrument complies with the WEEE Directive marking requirement. This affixed product label indicates that you must not discard this electrical or electronic product in domestic household waste.

Product category:

With reference to the equipment types in the WEEE directive Annex 1, this instrument is classified as a “Monitoring and Control Instrument” product.
The affixed product label is as shown below.
Do not dispose in domestic household waste.
To return this unwanted instrument, contact your nearest Keysight Service Center, or visit http://
about.keysight.com/en/companyinfo/environment/takeback.shtml for more information.

Sales and Technical Support

To contact Keysight for sales and technical support, refer to the support links on the following Keysight websites:
www.keysight.com/find/mta
(product-specific information and support, software and documentation updates)
www.keysight.com/find/assist
(worldwide contact information for repair and service)
4 Keysight 11636A Operating and Service Manual

Table of Contents

Safety Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Regulatory Markings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Waste Electrical and Electronic Equipment (WEEE) Directive . . . . . . . . . . . . . . . . . . . . 4
Product category: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Sales and Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
List of Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
List of Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Equipment and Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Cleaning Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Contacting Keysight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Keysight 11636A Operating and Service Manual 5
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.
6 Keysight 11636A Operating and Service Manual

List of Figures

Figure 1 Tracking between output ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Figure 2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Keysight 11636A Operating and Service Manual 7
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.
8 Keysight 11636A Operating and Service Manual

List of Tables

Table 1 Type-N adapters available from Keysight Technologies . . . . . . . . . . . 13
Table 2 Equipment and supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Keysight 11636A Operating and Service Manual 9
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK.
10 Keysight 11636A Operating and Service Manual

Introduction

From DC to 18 GHz, the 11636A provides excellent output power symmetry between the two output ports. Low temperature and power coefficients ensure attenuation stability. Each power divider is calibrated at four frequencies, and this data is provided on a sticker that is permanently attached to the unit.
Stable interface dimensions, which ensure long life and a high repeatability of insertion loss, are provided by injection molded interface connector insulators that maintain concentricity.
Any port may be used as an input, as the 11636A provides a symmetrical 6 dB division. The 11636A can be used as a power combiner. When signals are input at two of the ports, the sum of the two appears at the third.

Specifications

Maximum input power: 1.0 W CW, 1 kW peak (5 msec pulse width)
Frequency range: DC to 18 GHz
Input/output SWR:
– DC to 10.0 GHz:
~1.25
– 10.0 GHz to 26.5 GHz:
Tracking between output ports:
Frequency range (GHz) Tracking (dB)
DC to 4.0 0.2
4.0 to 10.0 0.4
10.0 to 18.0 0.5
Figure 1 Tracking between output ports
Calibration data: insertion loss at DC, 6.0, 12.0 and 18.0 GHz (data is supplied on a permanently attached sticker).
Number of ports: three
Connectors: one type-N male, two type-N female
~1.35
Keysight 11636A Operating and Service Manual 11
Dimensions:
NOTE: Dimensions are given in (cm) inches and are maximum unless otherwise specified
Figure 2 Dimensions
Dimension A Dimension B Dimension C Dimension D
(1.96) 0.77 (4.45) 1.75 (1.75) 0.69 (4.17) 1.64
Nominal insertion loss (Input to one output port): 6.0 dB (-0.2 dB, +1.2 dB maximum to 10.0 GHz; +1.5 dB maximum to 18.0 GHz)

Adjustments

Service

Typical phase tracking:
Power coefficient: <0.005 dB/dB/W
Temperature coefficient: <0.0004 dB/dB/
The 11636A power divider requires no electrical or mechanical adjustments.
The circuit elements of the 11636A are split into three identical channels. A malfunction will usually occur in only one channel and can be verified by moving the connection to another channel of the divider.
An ohmmeter can be used to check the continuity of the inner conductor connections. The resistance from either output center conductor to the input center conductor should be 33.3 ohms +/– 2 ohms.
There are no replaceable components for the power divider. A worn or damaged power divider must be replaced in whole.
\2° between output ports.
°C
12 Keysight 11636A Operating and Service Manual
Table 1 Type-N adapters available from Keysight Technologies
Description Part number
Type-N (m) to 3.5 mm (m) 1250-1743
Type-N (m) to 3.5 mm (f) 1250-1744
Type-N (f) to 3.5 mm (f) 1250-1745
Type-N (f) to 3.5 mm (m) 1250-1750
Type-N (m) to 2.4 mm (m) 11903A
Type-N (f) to 2.4 mm (f) 11903B
Type-N (f) to 2.4 mm (m) 11903C
Type-N (m) to 2.4 mm (f) 11903D

Equipment and Supplies

The following equipment and supplies are required for the maintenance and use of, but are not supplied with, your 11636A power divider.
Table 2 Equipment and supplies
Item Part number
Type-N gage set (part of the 85032F calibration kit) 85054-60059
Torque wrench, 3/4”, 136 N-cm (12 in-lb) 8710-1766
Document: connector care for RF and microwave coaxial connectors 08510-90064

Cleaning Connectors

For information on cleaning connectors, refer to the Connector Care for RF and Microwave Coaxial Connectors document. It can be viewed online by searching for part number 08510-90064 at
www.keysight.com.
Keysight 11636A Operating and Service Manual 13

Contacting Keysight

NOTE
Assistance with test and measurement needs and information on finding a local Keysight office are
available on the Web at:
www.keysight.com/find/assist
In any correspondence or telephone conversation, refer to the Keysight product by its model number and full serial number. With this information, the Keysight representative can determine whether your product is still within its warranty period.
14 Keysight 11636A Operating and Service Manual
This information is subject to change without notice. Always refer to the Keysight website for the latest revision.
© Keysight Technologies 2014 - 2019 Edition 2, January 17, 2019
Printed in Malaysia
*11636-90004*
11636-90004
www.keysight.com
Loading...