2 3
➔
Hot Plug Detection Control:
Enables integrator to choose if active signal
voltage is forced to connected input devices
➔
Full Buffer System™:
Manages TMDS re-clocking / signal re-generation,
HDCP authentication with source & display, EDID Control handshake,
and Hot Plug control
➔
IR Sensor:
Sensor powering via +5V on Rx unit’s IR In port collects line-of-sight
IR from remote(s) without external IR connecting block
➔
Up/Down IR:
Two channels of IR enable control to/from devices connected
to Tx and Rx units
➔
RS-232:
Bi-Directional control to/from Tx and Rx unit on 3.5mm connector
➔
Rotary Switch RS-232 Control Mode:
Provides control of Tx unit as well as
connectivity status
➔
3D:
Support for standard 3D stereoscopic signal formats
➔
Deep Color Support:
12bit Deep Color video / 8bit color for 4K/UHD
➔
Lossless compressed digital audio:
Support for Dolby® TrueHD, Dolby® Digital
Plus and DTS-HD Master Audio
™
➔
CEC Support:
For inter-device control between main input and output
HDMI channel
➔
I2C Communication:
EDID and HDCP authentication to Display and Source
➔
Control System Support:
Compatible with Compass Control®, AMX®,
Control4®, Crestron®, RTI®, Savant, URC®, Leviton® etc.
KD-X411ProK Accessories
➔ (2) 5V 2A DC Power Supplies (Screw-In Type), (2) Mounting Brackets,
(1) IR Emitter, (1) IR Sensor
➔ KD-X411ProK requires power on both Tx and Rx units
KD-X411POHK Accessories
➔ (1) 12V 2A DC Power Supply (Screw-In Type), (2) Mounting Brackets,
(1) IR Emitter, (1) IR Sensor
➔ KD-X411POHK only requires power on the Tx unit, which extends power
to the Rx unit
Quick Setup Guide
Step 1: Find a safe and convenient location to mount or place your
KD-X411ProK/KD-X411POHK units
Step 2: Begin with the KD-X411ProK/KD-X411POHK Tx/Rx units and all
input/output devices turned off with power cables removed
Step 3: Connect your HDMI source to the input port of your
KD-X411ProK/KD-X411POHK Tx unit
Step 4: Connect your HDMI displays to the output port of your
KD-X411ProK/KD-X411POHK Rx unit
Step 5: Connect KD-X411ProK/KD-X411POHK Tx unit to
KD-X411ProK/KD-X411POHK Tx with CAT5e/6 cable
Step 6: Connect additional IR/RS-232 control connections and IR sensors
Step 7:
BEFORE connecting power supply to power outlet,
screw-in the power
supply to the KD-X411ProK/KD-X411POHK Tx units and KD-X411ProK
Rx unit
Step 8:
AFTER all connections are made, plug-in power supplies to
power outlets
Step 9: Power on input/output devices
Installation and Operation
Before permanently securing the unit for final installation, test for proper operation
of the unit and cables in your system. It is recommended that you leave enough
ventilation space to provide sufficient airflow and cooling.
You MUST use the Power Supply provided with your unit or you VOID
the Key Digital
®
Warranty and risk damage to your unit and associated
equipment.
KD-X411ProK_X411POHK_Manual.indd 3 11/17/15 12:40 PM