Key Digital 8400 User Manual

Page 1
TM
AlphaServer 8400
V97-2.1—24 Jul 1997
DIGITAL Systems and Options Catalog
Product Description
The AlphaServer 8400—using the world’s fastest microprocessors, the Alpha 21164 300 MHz or 440 MHz CPUs—is the world’s fastest and highest capacity enterprise server. It is the solution for the most demanding business problems.
ServerWORKS Manager provides advanced server and network management capabilities and is supplied with all AlphaServer systems. SNMP (Simple Network Management Protocol) enables information to pass from the managed system to the console for Digital UNIX, Windows NT, and OpenVMS for AlphaServers. Using ServerWORKS, the system manager can build and view topological maps of the network. Detailed server information is viewable, including system, network, storage, and environmental information. All AlphaServer systems are also supplied with management tools to complement ServerWORKS Manager. These include StorageWorks Command Console for storage management. For more information, see the "StorageWorks Software" section of this catalog.
The AlphaServer 8400 5/300 supports up to 12 processors with 8 GB memory, two processors with 28 GB of memory, and any combination between these maximums, with 1.2 GB/sec (peak) of I/O.
The AlphaServer 8400 5/440 supports up to 14 processors with 4 GB memory, two processors with 28 GB of memory, and any combination between these maximums, with 1.2 GB/sec (peak) of I/O.
The AlphaServer 8400 supports the DIGITAL UNIX and OpenVMS operating systems. For investment protection, DEC and VAX 7000 products can be upgraded to the AlphaServer 8400 in a few hours. The AlphaServer 8400 platform is designed to take full advantage of future generations of Alpha microprocessors.
The AlphaServer 8400 enterprise servers join the AlphaServer line, with high performance PCI I/O, providing up to 144 PCI slots on 12 different physical PCI buses. The AlphaServer 8400 includes a one year hardware warranty, on-site, 4 hour response, five days per week. System installation is included with the AlphaServer 8400 5/440 system.
DIGITAL believes the information in this publication is accurate as of its publication date; such information is subject to change without notice. Digital is not responsible for any inadvertent errors.
DIGITAL conducts its business in a manner that conserves the environment and protects the safety and health of its employees, customers, and the community.
DIGITAL, and the DIGITAL logo are trademarks of Digital Equipment Corporation. Printed in USA. Copyright 1997 Digital Equipment Corporation. All rights reserved.
3.206 Alpha Servers
Page 2
Step 1—Base Systems
AlphaServer 8400
AlphaServer 8400 5/300 Systems require
- DIGITAL UNIX V3.2B or later, and OpenVMS V6.2 or later
AlphaServer 8400 5/440 Systems require
- DIGITAL UNIX V3.2G or DIGITAL UNIX V4.0A, or OpenVMS V6.2-1H3 or V7.1
Software media and documentation required for first system on site. See Step 13 for ordering information.
Console terminal required to install system. See Step 11 unless terminal is available on site.
System includes 9 slot centerplane—three slots used by the CPU module, memory module, and system I/O module (KFTIA-AA).
- Six slots available for additional CPU, memory, or system I/O module(s).
CD-ROM connected via single-ended SCSI-2 port on KFTIA-AA system I/O module.
2 GB or 4.3 GB SCSI system disk drive and DWZZB­VW are located in BA660-AB StorageWorks shelf and connected via Fast Wide Differential (FWD) port on KFTIA-AA system I/O module, using one CK-KFTIA­AA.
For recommended power protection see section after system specifications. UPS Power Management Software is included in ServerWORKS Manager kit. Software communicates with recommended UPS.
AlphaServer 8400 Base Servers include
Processor module with two Alpha microprocessor 21164 5/300 MHz or 5/440 MHz CPUs; each CPU includes 4 MB back-up cache
System I/O module (KFTIA-AA) includes
- I/O channel
- Two twisted-pair 802.3/Ethernets
- Single-ended SCSI-2 port
- Three Fast Wide Differential (FWD) SCSI-2 ports
Three CK-KFTIA-AA cabinet kits
256 MB, 512 MB, 2 GB or 4 GB of memory
BA660-AB StorageWorks Plug-in-unit (PIU)
2 GB or 4.3 GB 3.5” SCSI system disk drive
600 MB CD-ROM drive
DWZZB-VW SCSI signal converter
Three-Phase Power Subsystem with power cord
One H7263-AC or H7263-AD non-BBU capable 48 VDC power regulator
Shielded console cable is included for connection to the console terminal
Factory Installed Software
5/300 Operating System Software
- DIGITAL UNIX base license,
DIGITAL NAS Base Server 200 software, or
- OpenVMS base license,
DIGITAL NAS Base Server 200 software
5/440 Operating System Software
- DIGITAL UNIX base license,
Unlimited User license, Server Extension license, Internet Access Software license, or
- OpenVMS base license,
DIGITAL Enterprise Integration Package (EIP).
One year hardware product warranty
90 day software product warranty
System installation included with AlphaServer 8400 5/440 Base Servers
5/300 Dual-CPU systems Operating System Power Memory DA-291BC-BA/BB/BC DA-291BD-BA/BB/BC DA-291BF-DA/DB/DC DY-291BC-BA/BB/BC DY-291BD-BA/BB/BC DY-291BF-DA/DB/DC
DIGITAL UNIX Three Phase 256 MB DIGITAL UNIX Three Phase 512 MB DIGITAL UNIX Three Phase 2 GB OpenVMS Three Phase 256 MB OpenVMS Three Phase 512 MB OpenVMS Three Phase 2 GB
5/440 Dual-CPU systems Operating System Power Memory DA-292FF-CA/CB/CC DA-292FG-CA/CB/CC DY-292FF-CA/CB/CC DY-292FG-CA/CB/CC
DIGITAL UNIX Three Phase 2 GB DIGITAL UNIX Three Phase 4 GB OpenVMS Three Phase 2 GB OpenVMS Three Phase 4 GB
Note: xA = 60 Hz, 208 V, xB = 50 Hz, 380/416 V, xC = 50/60 Hz, 202 V Japan
All Three Phase power variations include attached power cord.
Alpha Servers 3.207
Page 3
AlphaServer 8400
Step 1—Base Systems
(continued)
AlphaServer 8400 Expanded Base Servers include:

Processor module with
- Two Alpha microprocessor 21164 5/300 MHz or 5/440 MHz CPUs; each CPU includes 4-MB Backup cache

System I/O module with four I/O channels (KFTHA­AA)

512 MB, 2 GB or 4 GB of memory

BA660-AB StorageWorks Plug-in-unit

2 GB or 4.3 GB 3.5” SCSI system disk drive

BN21K-02 2-meter SCSI cable(s)
- Two with 5/300 systems
- One with 5/440 systems

DWZZB-VW SCSI signal converter(s)
- Two with 5/300 systems
- One with 5/440 systems

600 MB CD-ROM drive

PCI 12 slot Plug-in-unit(s)
- One DWLPB-AA and one DWLPB-BA with 5/300 systems
- One DWLPB-AA with 5/440 systems

PCI Fast Wide Differential SCSI controller(s)
- Eight KZPSA-BBs with 5/300 DIGITAL UNIX systems
- Seven KZPSA-BBs with 5/300 OpenVMS systems
- One KZPSA-BB with 5/440 systems

PCI Fast Narrow Single-Ended SCSI controller KZPAA-AA for CD-ROM connection only

DIGITAL Etherworks 32-bit Network Interface Card

BN21H-02 2-meter SCSI cable

Two H7263-AC or H7263-AD non-BBU capable 48 VDC power regulators
- Three-Phase power subsystem includes power cord

Shielded console cable for connection to console terminal

Factory Installed Software

5/300 Operating System Software
- DIGITAL UNIX base license,
DIGITAL NAS Base Server 200 software, or
- OpenVMS base license, DIGITAL NAS Base Server 200 software

5/440 Operating System Software
- DIGITAL UNIX base license, Unlimited User license, Server Extension license, Internet Access Software license, or
- OpenVMS base license, DIGITAL Enterprise Integration Package (EIP).

One year hardware product warranty

90 day software product warranty

System installation included with AlphaServer 8400 5/440 Expanded Base Servers
5/300 Dual-CPU systems Operating System Power Memory DA-291BD-CA/CB/CC DA-291BF-HA/HB/HC DY-291BD-CA/CB/CC DY-291BF-HA/HB/HC
DIGITAL UNIX Three Phase 512 MB DIGITAL UNIX Three Phase 2 GB OpenVMS Three Phase 512 MB OpenVMS Three Phase 2 GB
5/440 Dual-CPU systems Operating System Power Memory DA-292FF-DA/DB/DC DA-292FG-DA/DB/DC DY-292FF-DA/DB/DC DY-292FG-DA/DB/DC
DIGITAL UNIX Three Phase 2 GB DIGITAL UNIX Three Phase 4 GB OpenVMS Three Phase 2 GB OpenVMS Three Phase 4 GB
Note: xA = 60 Hz, 208 V, xB = 50 Hz, 380/416 V, xC = 50/60 Hz, 202 V Japan
All Three Phase power variations include attached power cord.
3.208 Alpha Servers
Page 4
AlphaServer 8400
Step 1a—5/300 System Building Blocks
System Building Blocks are an alternative to standard Base Servers, or Expanded Base Servers. They provide flexibility in configuring the AlphaServer 8400 with a choice of memory and I/O options.
System Building Block Requirements:

Minimum of one Memory module

Minimum of one I/O module

CD-ROM Drive

Systems require DIGITAL UNIX V3.2B or later, and OpenVMS V6.2 or later.

Console terminal required unless available on site.

System consists of 9 slot backplane—three slots used by CPU, memory, and system I/O modules.
- Six slots available for additional CPU, memory, or system I/O module(s).

If KFTHA-AA I/O module is selected the following PCI or XMI options must be ordered to provide the interface to CD-ROM drive.
Required for PCI systems
DWLPB-AA KZPAA-AA
PCI plug-in unit. See Step 5 for details. PCI single-ended SCSI controller for CD-ROM connection only; KZPAA is restricted as CD-ROM
connection only, no other disk or tape connections are supported—maximum one per system.
BN21H-02
SCSI cable
Required for XMI systems
DWLMA-AA KZMSA-AB BN21H-02

CD-ROM, 600 MB 5.25” in cabinet drive (RRDCD-CA) is required and must be ordered separately.

If Factory Installed Software is required, BA660-AB, appropriate disk drive, and controller must be ordered separately.

Redundant power supply (N+1) can be added if required.
XMI plug-in unit. See Step 6 for details. XMI single-ended SCSI controller SCSI cable
AlphaServer 8400 5/300 System Building Blocks

Processor module with Two Alpha microprocessor 21164 5/300 MHz CPU(s), each CPU includes 4 MB Backup cache

Three-Phase Power Subsystem with power cord

48 VDC power regulator

DIGITAL UNIX base license, or

OpenVMS base license

DIGITAL NAS Base Server 200 software

One year hardware product warranty

90 day software product warranty
Dual-CPU systems Operating System Power Memory I/O Module DA-291BY-AA/AB/AC DY-291BY-AA/AB/AC
DIGITAL UNIX Three Phase Required Required OpenVMS Three Phase Required Required
Note: xA = 60 Hz, 208 V, xB = 50 Hz, 380/416 V, xC = 50/60 Hz, 202 V Japan
All Three Phase power variations include attached power cord.
Alpha Servers 3.209
Page 5
AlphaServer 8400
Step 1b—AlphaServer Expansion Packages
AlphaServer Expansion Packages are designed to be added to Base AlphaServers, Expanded Base Servers, and System Building Blocks to create fully functional CI cluster add-on systems. They include all the necessary hardware (excluding console terminal) and software to provide complete and operational systems.
Note: These packages are only orderable with a system configuration. They are not orderable as stand alone, upgrade
options or spared on the order.
OpenVMS AlphaServer Expansion Package
8YCAA-AX
Cluster Add-on Package includes:
DWLMA-AA XMI plug-in unit CIXCD-AC XMI CI controller One BNCIA 10-meter cable OpenVMS cluster License (QL-MUZAQ-AA)
Step 2—Additional CPU Modules (SMP Upgrades)

5/300 MHz systems support a maximum of 6 processor modules (total of 12 CPUs)

5/440 MHz systems support a maximum of 7 processor modules (total of 14 CPUs) under UNIX V3.2G and V4.0B or OpenVMS V6.2-1H3 and V7.1. Requires console V4.8-6 or later firmware and DECevent V2.3 plus patch files included in the QZ-00RAA-T8 kit.

Combining 5/300, 5/350, or 5/440 MHz CPU modules in same system is not supported.

For more than three processor modules in a system, a minimum of two separate memory modules are recommended for optimal system performance.

All SMP upgrades include processor module with Alpha microprocessor(s) SMP license, and end-user product warranty.
5/300 Servers 5/350 Servers 5/440 Servers CPU Module Type Operating System 751P2-AX 753P2-AX N/A 752P2-AX 754P2-AX 756P2-AX 751P1-AX N/A 752P1-AX 754P1-AX 756P1-AX
Single-CPU DIGITAL UNIX Dual-CPU DIGITAL UNIX Single-CPU OpenVMS Dual-CPU OpenVMS
Step 3—Memory

Maximum of 28 GB of memory supported on 5/300 MHz CPUs Rev H07, H08, H09, P08, P09, P10, and all 5/350 and 5/440 MHz CPUs.

For Base Servers or Expanded Base Servers order up to six additional memory modules—system maximum seven.

System Building Blocks require the selection of one memory module—system maximum seven.

Maximum of seven memory modules is reduced by one for each additional CPU module added from Step 3 and

Memory modules
- 128 MB through 2 GB memory modules have built in two-way interleaving; additional interleaving is accomplished by adding more memory modules
- 4 GB memory modules have built in four-way interleaving. Best performance is achieved when two 2 GB modules are paired with one 4 GB module. This set (2 x 2 GB and 1 x 4 GB) can be paired with another 8 GB memory set for a maximum of 16-way memory interleaving.
each additional System I/O module added from Step 5.
MS7CC-BA MS7CC-CA MS7CC-DA MS7CC-EA MS7CC-FA MS7CC-GA
1. Supported on 5/300 MHz CPUs Rev H07, H08, H09, P08, P09, P10, and all 5/350 and 5/440 MHz CPUs.
1
128 MB memory module 256 MB memory module 512 MB memory module 1073 MB memory module 2147 MB memory module 4294 MB memory module
3.210 Alpha Servers
Page 6
AlphaServer 8400
Step 3a—Memory Upgrades

Memory upgrades are field installed only (not configured in Manufacturing).
MS7CC-UA
128 MB memory upgrade (8 MB SIMMs); upgrades 128 MB (-BA) module to 256 MB (-CA) module
MS7CC-UB
512 MB memory upgrade (32 MB SIMMs); upgrades 512 MB (-DA) module to 1 GB (-EA) module
Step 3b—Prestoserve Non-Volatile Random Access Memory (NVRAM)

Supported on DIGITAL UNIX systems only.

Maximum one Prestoserve I/O performance enhancement option per system.

Includes Prestoserve license and documentation kit.
DJ-ML200-BA DJ-ML200-CA DJ-ML300-BA
4 MB Prestoserve; PCI option—requires DWLPB-AA/BA 8 MB Prestoserve; PCI option—requires DWLPB-AA/BA 4 MB Prestoserve; KFTIA-AA daughter card mounting, requires KFTIA-AA
Step 4—I/O Expansion Buses
PCI and XMI I/O expansion buses are available on AlphaServer 8400 systems. Application and system configuration determines maximum I/O configuration. Configuration limits exist at I/O bus level and controller level. With different I/O buses present in the system, verify maximum number of allowed controllers listed in the Controller Configuration Table.

Each DWLPB-AA/AB (PCI plug-in unit) includes a 12-slot PCI bus and uses one rear expansion bay. SCSI disks in BA660-AB plug-in units can occupy the corresponding front expansion bay.

Each DWLPB-AA/AB (PCI plug-in unit) has one open space for addition of DWLPB-BA/BB (second PCI expansion box) or BA661-AA (Wide SCSI StorageWorks shelf)
DWLPB-AA
PCI plug-in unit with one PCI box for AlphaServer 8400 system cabinet only, maximum two per
system cabinet, two per system. Requires one I/O channel connection on either KFTIA-AA or KFTHA-AA.
DWLPB-AB
PCI plug-in unit with one PCI box for AlphaServer 8400 expansion cabinet only, maximum two
per expansion cabinet, four per system. Maximum of six DWLPB-AA and DWLPB-AB (PCI plug-in units) per system. Requires one I/O channel connection on either KFTIA-AA or KFTHA-AA.
DWLPB-BA
Second PCI expansion box for mounting in DWLPB-AA—maximum one per DWLPB-AA.
Requires one I/O channel connection on either KFTIA-AA or KFTHA-AA.
DWLPB-BB
Second PCI expansion box for mounting in DWLPB-AB—maximum one per DWLPB-AB.
Requires one I/O channel connection on either KFTIA-AA or KFTHA-AA.
BA661-AA
Wide SCSI StorageWorks Shelf (BA356-LB) can be added to DWLPB-AA/AB in place of second
PCI expansion box (DWLPB-BA/BB). Maximum one BA661-AA per DWLPB-AA/AB, and maximum of six BA661-AA per system. Supports 16-bit (Wide) SCSI and some 8-bit (Narrow) SCSI devices.
KFE70-AA
EISA Bridge option—PCI to EISA bridge module set—must reside in first DWLPB-AA in system
cabinet only. Converts PCI bus from 12-slot bus to 2 EISA, 6 PCI/EISA, and 2 PCI slots. Includes RX26 floppy drive, mounting hardware, and cables to mount RX26 below CD-ROM in the system cabinet. Maximum of one EISA Bridge option per system. This option is required to support KZPSC SCSI RAID controllers. It includes the floppy disk drive required to run the RAID Configuration Utility (RCU).
DWLMA-AA
XMI plug-in unit for system cabinet—maximum two per system. Requires one I/O channel
connection on either KFTIA-AA or KFTHA-AA.
DWLMA-BA
XMI plug-in unit for I/O expansion cabinet—maximum two per cabinet, four per system. Total
maximum six DWLMA-AA and DWLMA-BA (XMI plug-in units) per system. Requires one I/O channel connection on either KFTIA-AA or KFTHA-AA.

Each DWLMA-AA/BA (XMI plug-in unit) includes one 12-slot XMI channel—uses two expansion bays, front and back.

Each PCI and XMI plug-in unit requires one I/O channel connection to either KFTHA-AA or KFTIA-AA, see Step
6.

Maximum of twelve I/O channels supported (three KFTHAs).
Alpha Servers 3.211
Page 7
AlphaServer 8400
Step 5—System I/O Modules

KFTIA-AA system I/O module included with Base Server; KFTHA-AA included with Expanded Base Server—any combination of KFTIA or KFTHA modules can be added for a maximum of three.
- Maximum twelve I/O channels available on AlphaServer 8400.

System Building Block requires the selection of one I/O module.
KFTHA-AA KFTIA-AA
BN26M-xx BN21H-xx
CK-KFTIA-AA
BN21K-xx
BN21K-02*
BN21K-03* BN21K-05/10
* Manufacturing may substitute correct cable length depending on configuration.
System I/O module with four I/O channels for PCI or XMI plug-in units System I/O module with one I/O channel for PCI or XMI plug-in units. Includes
- two 802.3 twisted-pair Ethernet ports—requires BN26M cable per port
- single-ended SCSI-2 port—requires BN21H cable
- three FWD (Fast Wide Differential) SCSI-2 ports—requires CK-KFTIA-AA and BN21K cable per port
One of the following optional FDDI daughter cards can be added to KFTIA-AA—see Step 8 for cables.
- Single attachment station multi-mode fiber card (DEFPZ-AA) or
- Twisted-pair copper card (DEFPZ-UA)
Prestoserve (DJ-ML300-BA) can be added to KFTIA-AA Ethernet twisted-pair cable; 8-pin MP to 8-pin MP, screened, EIA/TIA Category 5 cable. SCSI-2 Single-ended cable; 50-pin male straight to 50-pin male straight. Connects KFTIA-AA
single-ended SCSI-2 port to StorageWorks shelf. Cabinet kit for FWD (Fast Wide Differential) SCSI-2 port. One kit required for each used port on
KFTIA-AA, maximum three per KFTIA-AA. Cabinet kit includes Y-cable and FWD terminator. SCSI-2 Fast Wide Differential cables; 68-pin male straight to 68-pin male right-angle. Connects
KFTIA-AA Fast Wide Differential SCSI-2 ports to DWZZA-VA or DWZZB-VW. Connects from KFTIA FWD port to DWZZB-VW in BA660-AB System cabinet (rear)
Connects from KFTIA FWD port to DWZZB-VW in BA661-AA in DWLPB-xx PIU Connects from KFTIA FWD port to DWZZB-VW in BA660-AB System cabinet (front) Connects from KFTIA FWD port to DWZZB-VW in BA660-AB Expansion cabinet (front or rear)
Connects from KFTIA FWD port to DWZZB-VW in BA356-JB in SW500 and SW800 Cabinets
Step 6—Storage Controllers

KFTIA-AA included with each Base Server; KFTHA-AA included with Expanded Base Server—PCI, EISA, and XMI storage controllers can be added.
- Requires corresponding PCI plug-in unit (DWLPB­AA/AB/BA/BB) or XMI plug-in unit (DWLMA­AA/BA).

DWZZA-AA requires minimum revision E02 for connecting any Fast Wide Differential SCSI-2 port from KFTIA-AA or KZPSA-BB to TZ8xx tape loaders.
PCI-based Storage Controllers
KZPSA-BB
BN21K-xx
BN21K-01*
BN21K-02* BN21K-05/10
PCI Fast Wide Differential SCSI Adapter—OpenVMS V6.2-1H3 supports eight per PCI,
maximum 26 per system. DIGITAL UNIX supports eight per PCI, maximum 32 per system (uses one PCI slot). Provides one SCSI-2 bus. KZPSA supports DECsafe Available Server.
SCSI-2 Fast Wide Differential cables68-pin male straight to 68-pin male right-angle. Connects KZPSA-BB Fast Wide Differential SCSI-2 port to DWZZA-VA or DWZZB-VW.
Connects from KZPSA to DWZZB-VW in BA660-AB System cabinet (rear) Connects from KZPSA to DWZZB-VW in BA661-AA in DWLPB-xx PIU
Connects from KZPSA to DWZZB-VW in BA660-AB System cabinet (front) Connects from KZPSA to DWZZB-VW in BA660-AB Expansion cabinet (front or rear)

DWZZB-VW Fast Wide Differential Single-ended SCSI Converter requires minimum revision A01 for connecting FWD SCSI-2 signals from KFTIA-AA or KZPSA-BB to BA356-JB StorageWorks Shelf.

System maximum of four KZPSC or KZPAC SCSI RAID controllers.
Tape and optical devices are not supported on KZPSC or

KZPAC SCSI RAID controllers.
3.212 Alpha Servers
Page 8
AlphaServer 8400
Step 6—Storage Controllers
(continued)
PCI-based Storage Controllers
KZPAC-AA
PCI one-port SCSI RAID Controller with 4 MB cache memory—Uses one PCI slot. Provides one
fast/wide single-ended connection. Allows RAID levels 0, 1 and 5. Includes RAID Array 230/plus subsystem software and documentation kit. KFE70-AA EISA Bridge option required. Tape and optical drives not supported. Maximum of 4 per PCI, maximum of 4 per system supported with DIGITAL UNIX V3.2G or V4.0B; OpenVMS V6.2-1H3 or v7.1.
KZPAC-CA
PCI three-port SCSI RAID Controller with 4MB cache memory—Uses two PCI slots. Provides
three fast wide/single-ended connections. Allows RAID levels 0, 1 and 5. Includes RAID/Array 230/plus subsystem software and documentation kit. KFE70-AA EISA Bridge option required. Tape and optical drives not supported. Maximum of four per PCI, maximum of four per system if third port not used (otherwise maximum of three per PCI, three per system) supported with DIGITAL UNIX V3.2G or V4.0B; OpenVMS V6.2-1H3 or V7.1. Order BN31K-0E or KZPAC-SB for third port connection.
KZPAC-CB
PCI three-port SCSI RAID Controller with 8MB cache memory—Uses two PCI slots. Provides
three fast wide/single-ended connections. Allows RAID levels 0, 1 and 5. Includes RAID/Array 230/plus subsystem software and documentation kit. KFE70-AA EISA Bridge option required. Tape and optical drives not supported. Maximum of four per PCI, maximum of four per system if third port not used (otherwise maximum of three per PCI, three per system) supported with DIGITAL UNIX V3.2G or V4.0B; OpenVMS V6.2-1H3 or V7.1. Order BN31K-0E or KZPAC-SB for third port connection.
BN31S-1E
1.5 meter wide single-ended SCSI cable for connections from PCI RAID controller to BA660-AB system cabinet (in front and rear locations) and BA661-AA. One required for each used port on KZPSC-BA or KZPAC-CA/CB module.
BN31K-0E
Required for KZPSC-BA or KZPAC-CA/CB to use third port on module. Connects internally from KZPSC-BA module to second PCI slot/bulkhead.
KZPAC-SB
SCSI cable/bulkhead assembly kit with two ports for KZPSC-BA or KZPAC-CA/CB, allows connection of two third-port outputs using one PCI bulkhead slot.
BN31S-02
2.0 meter wide single-ended SCSI cable for connections from PCI RAID controller to BA660-AB system cabinet and BA661-AA.
KZPSC-UB MS100-BB KZPSC-AA
Battery back-up for cache memory option for KZPAC or KZPSC controller. 8 MB cache memory option; upgrades KZPAC-CA to KZPAC-CB, field installable only. PCI one-port SCSI RAID Controller—OpenVMS and DIGITAL UNIX support four per PCI,
maximum four per system (uses one PCI slot). KFE70-AA EISA Bridge option required. Provides one fast/wide/single-ended connection. Allows RAID levels 0, 1, and 5. Tape drives are not supported.
KZPSC-BA
PCI SCSI RAID Controller with three ports—OpenVMS and DIGITAL UNIX support four per
PCI, maximum four per system (uses two PCI slots). KFE70-AA EISA Bridge option required. Provides three Fast Wide/single-ended connections. Allows RAID levels 0,1, and 5. Tape drives not supported. Order BN31K-0E or KZPAC-SB for third port connection.
BN31S-1E
1.5 meter wide single-ended SCSI cable for connections from PCI RAID controller to BA660-AB system cabinet (in front and rear locations) and BA661-AA. One required for each used port on KZPSC-BA or KZPAC-CA/CB module.
BN31K-0E
Required for KZPSC-BA or KZPAC-CA/CB to use third port on module. Connects internally from KZPSC-BA or KZPAC-CA/CB module to second PCI slot/bulkhead.
KZPAC-SB
SCSI cable/bulkhead assembly kit with two ports for KZPSC-BA or KZPAC-CA/CB, allows connection of two third-port outputs using one PCI bulkhead slot.
BN31S-02
2.0 meter wide single-ended SCSI cable for connections from PCI RAID controller to BA660-AB system cabinet and BA661-AA.
KZPSC-UB MS100-AA MS100-AB KFPSA-AA
† †
Battery back-up for cache memory option for KZPAC or KZPSC controller. 16 MB Cache memory option for KZPSC-AA/BA, maximum one per controller, field installable only. 32 MB Cache memory option for KZPSC-AA/BA, maximum one per controller, field installable only. PCI DSSI Adapter (OpenVMS only)—Requires OpenVMS V6.2-1H2 or later; minimum
System Console Firmware Revision 3.09. Maximum twelve per PCI, 24 per system with OpenVMS V6.2-1H3. (End node only) Note: KFPSA and KFMSB not supported on the same bus.
BC21Q-xx BC22Q-xx
† Requires AlphaServer 8400 minimum System Console Firmware Revision V3.2.2, OpenVMS V6.2-1H2 and DIGITAL UNIX V3.2D
or later operating system software.
External shielded cable (MR/MR connectors) Select required length—09, 16, 25, 50 ft External shielded cable (MR/PS connectors) Select required length—16, 25, 50 ft
Alpha Servers 3.213
Page 9
AlphaServer 8400
Step 6—Storage Controllers
CIPCA-AA
PCI-to-CI Adapter (OpenVMS only)—Requires OpenVMS V6.2-1H3 or V7.1, minimum System
(continued)
Console Firmware Revision 4.0-4. Maximum four per PCI, 26 per system running OpenVMS V7.1. Uses one PCI slot for adapter and one EISA slot for power only. Note: KFE70 option is not required.
CIPCA-BA BNCIA-xx
Same as above except uses two PCI slots Computer interconnect cable setsConnects CIPCA to Star Coupler. Select required length—10, 20,
or 45 m (10 m = 32.8 ft, 20 m = 65.6 ft, 45 m = 147.6 ft)
Note
: For OpenVMS systems with greater than 1 GB of memory, the following TIMA patch kits are required to support KZPAC op-
tions:V 6.2 kit-ALPDRIV04_062; V7.1 kit-ALPDRIV01_071.
XMI-based Storage Controllers
KZMSA-AB
Fast single-ended SCSI-2 Disk/Tape Adapter—OpenVMS supports six per XMI, maximum 12 per
system. DIGITAL UNIX supports 10 per XMI, maximum 16 per system (uses one XMI slot). Provides two single-ended SCSI-2 buses. KZMSA supports DECsafe Available Server.
CK-KZMSA-LA CIXCD-AC
Two 30” internal cabinet cablesOne kit per KZMSA required. XMI CI Controller—OpenVMS supports four per XMI, maximum 10 per system. DIGITAL UNIX
supports one per XMI, maximum one per system (uses one XMI slot). The CIXCD requires one BNCIA cable set to connect system to Star Coupler. OpenVMS Cluster software license required for each system when multiple OpenVMS systems are used in cluster environment. Note: One CIXCD is supported on DIGITAL UNIX systems for expanded disk interconnect capability only.
BNCIA-xx
Computer interconnect cable setsConnects Star Coupler to system and SW800. Select required length—10, 20, or 45 m (10 m = 32.8 ft, 20 m = 65.6 ft, 45 m = 147.6 ft).
Step 6a—Non-Backplane External Storage Controllers

HSZ50 family of SCSI Storage Array Controllers are supported under DIGITAL UNIX V3.2G and V4.0A and OpenVMS V6.2-1H3. A DIGITAL UNIX patch OSF405-034 is required for dual redundant failover.

HSJ50 family of CI Storage Array Controllers are supported under OpenVMS V6.2-1H3 with CIPCA-AA/BA or CIXCD-AC CI controllers. QB-5C4AA-SA software kits are required for each external cache (1 for HSJ50, 2 for HSJ52, 4 for HSJ54).

HSD50 family of DSSI Storage Array Controllers are supported under OpenVMS V6.2-1H3 with minimum SRM console version V4.1-6.
- Controllers require KZPSA, KZMSA, KFPSA, CIXCD or CIPCA SCSI adapters
or controllers, as appropriate.
- HSZ50-Ax requires one QB-5CJAA-SA kit.
- HSZ52-Ax requires two QB-5CJAA-SA kits.
- HSZ54-AJ requires four QB-5CJAA-SA kits.
HSZ50-AF
HSZ50-AH
HSZ50-AJ
HSZ52-AF
HSZ52-AH
HSZ52-AJ
StorageWorks RAID Array 450/HSZ50 32 MB SCSI controller, 6 SCSI channels, 36 SCSI-2 device connections, 32 LUN maximum, 32 MB cache module, single external cache battery system building block.
StorageWorks RAID Array 450/HSZ50 64 MB SCSI controller, 6 SCSI channels, 36 SCSI-2 device connections, 32 LUN maximum, 64 MB cache module, single external cache battery system building block.
StorageWorks RAID Array 450/HSZ50 128 MB SCSI controller, 6 SCSI channels, 36 dual, 42 single SCSI-two-device connections, 32 LUN maximum, 128 MB cache module, single external cache battery system building block.
StorageWorks RAID Array 450/HSZ50 64 MB dual SCSI controllers, 12 SCSI channels, 36 SCSI­two-device connections, 32 LUN maximum, two cache modules, one dual external cache battery system building block, two external cache batteries, two 2-meter cables.
StorageWorks RAID Array 450/HSZ50 128 MB dual SCSI controllers, 12 SCSI channels, 36 SCSI­two-device connections, 32 LUN maximum, two cache modules, one dual external cache battery system building block, two external cache batteries, two 2-meter cables.
StorageWorks RAID Array 450/HSZ50 256 MB dual SCSI controllers, 12 SCSI channels, 36 SCSI­two-device connections, 32 LUN maximum, two cache modules, one dual external cache battery system building block, two external cache batteries, two 2-meter cables.
3.214 Alpha Servers
Page 10
AlphaServer 8400
Step 6a—Non-Backplane External Storage Controllers
HSZ54-AJ
StorageWorks RAID Array 450/HSZ50 512 MB quad SCSI controllers, 12 SCSI channels, 72 SCSI-
(continued)
two-device connections, 64 LUN maximum, four cache modules, two dual external cache battery system building blocks, four external cache batteries, four 2-meter cables.
HSJ50-AF HSJ50-AH HSJ50-AJ HSJ52-AF HSJ52-AH HSJ52-AJ HSJ54-AJ HSD50-AF HSD50-AH HSD50-AJ HSD52-AF HSD52-AH HSD52-AJ
32 MB Cache 6 channel CI array controller with cache battery 64 MB Cache 6 channel CI array controller with cache battery 128 MB Cache 6 channel CI array controller with cache battery Dual 64 MB Cache CI array controller with cache batteries Dual 128 MB Cache CI array controller with cache batteries Dual 256 MB Cache CI array controller with cache batteries Quad 512 MB Cache CI array controller with cache batteries DSSI Controller, 6 channel, 64MB cache & external cache battery DSSI Controller, 6 channel, 32MB cache & external cache battery DSSI Controller, 6 channel, 128MB cache & external cache battery Two DSSI Controllers with 32 MB cache with battery Two DSSI Controllers with 64 MB cache with battery Two DSSI Controllers with 128 MB cache with battery
Step 7—Storage
Note: When multiple storage devices are configured with the system, specify which devices should be installed inside the
system cabinet, inside the system expansion cabinet, or installed in the external StorageWorks cabinet. Line item sequencing allows Manufacturing to configure storage options in the appropriate cabinet.
- List storage options to be integrated in system cabinet immediately following the system part number.
- List storage options to be integrated in StorageWorks cabinet immediately following StorageWorks cabinet part number.
- Order the appropriate BN21*-** SCSI cables for connecting controllers and SCSI storage options.

Wide SCSI devices are supported in BA660-AB/BA661-AA StorageWorks PIUs, or external StorageWorks cabinets. BA660-AB/BA661-AA support both wide and narrow SCSI 5400 RPM and 7200 RPM disk drives.

System cabinet provides space for four disk plug-in units (PIU) if no PCI or XMI plug-in units are installed. Each of the two pairs of expansion bays (front to back) in bottom of system cabinet can hold one Battery PIU, one XMI PIU, one PCI PIU, one PCI PIU plus one SCSI disk PIU, one SCSI disk PIU, or two SCSI disk PIUs.

System cabinet provides space for up to seven StorageWorks shelves—three BA660-AB plug-in-units (each includes two StorageWorks shelves) and one BA661-AA StorageWorks shelf. Each shelf holds a maximum of two 5.25” devices and one 3.5” device or seven 3.5” devices. Typical configurations will require a signal converter, i.e., DWZZB-VW which counts as one 3.5” device.
Wide SCSI Options

StorageWorks shelves (BA356-xx) are normally configured in single bus mode (seven SCSI devices per shelf). To configure BA356-xx shelf in split-bus mode the following options are required:
- Split-bus terminator (BA35X-ME)
- SCSI controller for each active SCSI port
- SCSI cables to connect each controller to BA356-xx shelf
BA660-AB *
Wide SCSI-2 StorageWorks plug-in-unit
includes two BA356-LB modular expansion shelves, 16-
bit I/O personality module, 48V/150W DC power supply, DC fans, and AlphaServer 8400 mounting hardware. Supports 16-bit wide SCSI devices and some 8-bit narrow SCSI devices depending on compliance with minimum hardware revision levels.
BA661-AA *
Wide SCSI-2 StorageWorks Shelf
includes 16-bit I/O personality module, 48V/150W DC power
supply, DC fans, mounting hardware and BA356-LB. Can be added to DWLPB-AA/AB in place of second PCI expansion box (DWLPB-BA/BB). Maximum one BA661-AA per DWLPB-AA/AB; maximum six BA661-AA per system. Supports 16-bit (wide) SCSI and some 8-bit (narrow) SCSI devices.
DWZZB-VW
Wide SCSI-2 StorageWorks Signal Converter—required to convert FWD signals from KFTIA-AA
and KZPSA-BB for use in BA660-AB and BA661-AA/BA.
Alpha Servers 3.215
Page 11
AlphaServer 8400
Step 7—Storage
Wide SCSI Options (
BA35X-MG
(continued)
continued
8-bit I/O Personality Module—can be used in place of 16-bit I/O personality module for direct
)
connection to narrow single-ended controllers, field installable only.
Note: BA35X-ME terminators must be ordered separately to split a BA356 bus. 16-bit Disk Drives
DS-RZ28M-VZ
2.1 GB 16-bit 5400 RPM SCSI-2 disk drive in 3.5” carrier supported under OpenVMS V6.2-1H3 and UNIX V3.2G
DS-RZ1BB-VW RZ29B-VW DS-RZ1CB-VW DS-RZ1DB-VW
2.1 GB 7200 RPM 16-bit Wide disk drive
4.3 GB 16-bit 7200 RPM SCSI-2 disk drive in 3.5” carrier
4.3 GB 7200 RPM 16-bit Wide disk drive
9.0 GB 7200 RPM 16-bit Wide disk drive
Note: To ensure 16-bit wide SCSI operation, use wide SCSI drives with wide SCSI controllers in wide SCSI
StorageWorks shelves with wide SCSI cables. See Storage Devices—StorageWorks Supported Devices for 8-bit and 16-bit Expansion Table for minimum hardware revision levels.
The DS-RZ1xB-VW disk drives are not supported in a BA356 shelf on the same SCSI bus with 5.25" devices. The minimum operating system version tested includes OpenVMS V6.2-1H3 and DIGITAL UNIX V4.0B.
8-bit Disk Drives
DS-RZ28M-VZ DS-RZ28L-VA DS-RZ29L-VA DS-RZ40-VA
2.1 GB 5400 RPM 8-bit Narrow SCSI disk drive
2.1 GB 7200 RPM 8-bit Narrow SCSI disk drive
4.3 GB 7200 RPM 8-bit Narrow SCSI disk drive
9.0 GB 7200 RPM 8-bit Narrow SCSI disk drive
Tape Devices
TLZ09-VA
8.0 GB DAT 3.5” SCSI tape drive in StorageWorks carrier. OpenVMS V6.2-1H3 and DIGITAL UNIX V3.2C required along with System Console Firmware Revision 3.0-9.
TLZ9L -VA TKZ9E -VA TZ87-VA
32/64 GB DAT tape loader in StorageWorks carrier 2/5/7/10/14 GB 8 mm helical scan tape drive in 5.25” StorageWorks carrier
20.0 GB DLT 5.25” SCSI tape drive in StorageWorks carrier; must be mounted in BA660-AB located in rear of cabinet or BA661-AA located in DWLPB-xx.
TZ88N-VA TZ89N-VA
20/40 GB DLT 5.25” SCSI tape drive in StorageWorks carrier 35/70 GB DLT 5.25” SCSI tape drive in StorageWorks carrier
Solid State Disks

Supported with KZMSA, KZPSC, KZPSA, KFTIAcannot be combined with RZxx disks/tapes on same SCSI bus
EZ31-VW EZ32-VW EZ64-VA/VW EZ69-VA/VW
134 MB Solid State Disk; requires OpenVMS V6.2 or later and DIGITAL UNIX V3.2C or later 268 MB Solid State Disk; requires OpenVMS V6.2 or later and DIGITAL UNIX V3.2C or later 475 MB Solid State Disk; requires OpenVMS V6.2 or later and DIGITAL UNIX V3.2C or later 950 MB Solid State Disk; requires OpenVMS V6.2 or later and DIGITAL UNIX V3.2C or later
Step 7a—StorageWorks Expansion Packages
StorageWorks Expansion Packages have been created to simplify ordering StorageWorks options. They are intended to be used with Expanded Base Servers.

Order the correct number of HSZ40-TL packages to fill the BA350-MB RAID controller shelves in the SW82x StorageWorks Cabinet package.

Order disk drives separately
3.216 Alpha Servers
Page 12
AlphaServer 8400
Step 7a—StorageWorks Expansion Packages (

SW820/SW821 StorageWorks Expansion Packages—all BA356 shelves operate in split-bus mode.

All SW82x StorageWorks Expansion Packages include redundant power supplies (BA35X-HF)—this reduces the
continued
)
number of available slots in each BA356 shelf to six in the SW822 and three on each split-bus of the SW820/SW821.
StorageWorks Expansion Packages
SW820-LA/LB
SW800 StorageWorks Cabinet with five BA350-MB RAID controller shelves, 15 BA356-JC device shelves, 15 BA35X-MG 8-bit I/O personality modules for BA356, 30 BN21H-02 SCSI-2 single-ended cables, 20 BA35X-HF redundant power supplies, 15 BA35X-ME terminator boards—split-bus mode
SW821-LA/LB
SW800 StorageWorks Cabinet with seven BA350-MB RAID controller shelves, 14 BA356-JC device shelves, 14 BA35X-MG 8-bit I/O personality modules for BA356, 28 BN21H-02 SCSI-2 single-ended cables, 21 BA35X-HF redundant power supplies, 14 BA35X-ME terminators boards—split-bus mode
SW822-LA/LB
SW800 StorageWorks Cabinet with three BA350-MB RAID controller shelves, 18 BA356-JC device shelves, 18 BA35X-MG 8-bit I/O personality modules for BA356, 18 BN21H-02 SCSI-2 single­ended cables, 21 BA35X-HF redundant power supplies
HSZ40-TL
Two HSZ40B SCSI RAID array controllers each with 32 MB cache, HSZ Traditional License (QL-2YJA9-AA), RAID HSZ40 Firmware License (QL-3J0A9-AA), Mirror Firmware HSZ40 Traditional License (QL-4DTA9-AA), BN21K-20 20-meter cable, BN21L-0B .15-meter cable
Step 7b—External Storage (I/O Expansion Cabinet)
I/O expansion cabinet (H9F00-BA/BB/BC/BD) provides space for up to six SCSI disk plug-in units (PIU) if no other PCI/XMI plug-in unit (PIU) is configured in the expansion cabinet. Each of the two pairs of expansion bays in the bottom of the cabinet can hold one Battery PIU, one PCI PIU, one XMI PIU, or two SCSI disk PIUs. Two expansion bays in the top of the expansion cabinet can hold up to two SCSI disk PIUs. Disk and tape drives supported are the same as Step 7 Internal Storage.
Step 7c—External Storage
The following list describes available disk storage devices and capacities. These supported options can be added as required.
Storage Cabinets Capacity SW5XX, SW8XX SCSI Disk Drives Capacity See Step 7 Tape Drives TZ87, TZ875*, TZ877, TZ88,
TZ885, TZ887, TSZ07, TKZ9E, TKZ60, TKZ61, TKZ62, TL810, TL812, TL820, TL822, TL826, DS-TL893-BA†, DS-TL894-BA† DS-TL896-BA†
Optical Libraries RW546-ZA RW551-ZC RW552-ZF RW555-ZF RW557-ZF
* Loader support for DIGITAL UNIX is available via DECnsr. † Not supported on KZMSA XMI SCSI controllers.
6227 GB
Storage Devices
See
36 GB Optical Library, 2 drives 73 GB Optical Library, 2 drives 147 GB Optical Library, 4 drives 294 GB Optical Library, 4 drives 547 GB Optical Library, 6 drives
for ordering information.
Alpha Servers 3.217
Page 13
AlphaServer 8400
Step 8—Networks and Communications
Two twisted-pair 802.3/Ethernet controllers on KFTIA-AA system I/O module included with Base Server; DE500 fast ethernet network interface card included with Expanded Base Server. See Step 5 for twisted-pair Ethernet cable part number. Optional DEFPZ-AA/UA (FDDI) daughter card can be installed on KFTIA-AA system I/O module. Select additional devices if required. Note: Connection of system to Ethernet requires twisted-pair cable. See Network Products Guide for details.
LAN Communications Controllers—KFTIA-AA Daughter Cards

Maximum one FDDIcontroller fiber daughter card per KFTIA-AA I/O module
DEFPZ-AA
FDDIcontroller Fiber—Single Attachment Stationdaughter card for mounting on KFTIA-AA.
Requires BN24x cable.
BN24E-xx BN24D-xx DEFPZ-UA
Fiber-Optic Cable, Dual 2.5mm Bayonet “ST” type connectors Fiber-Optic Cable, Dual 2.5mm Bayonet “ST” type connector to FDDI “MIC” connector FDDIcontroller Fiber—Twisted-pair Copperdaughter card for mounting on KFTIA-AA.
Requires BN26x cable.
BN26M-xx BN26S-xx
LAN Communications Controllers
Requires DWLPB-AA/AB/BA/BB

System maximum of six DEFPA-AB/DB/UB/MB FDDIcontrollers.

DE450-CA
8-pin MP to 8-pin MP, screened, EIA/TIA Category 5 cable 8-pin MP to 8-pin MP, screened, crossover, EIA/TIA Category 5 cable
PCI based
PCI-to-Ethernet 3-port Adapter (uses one PCI slot). OpenVMS (V6.2) and DIGITAL UNIX (V3.2C) support eight per PCI, maximum eight per system. Two patch kits required to support DE450 with OpenVMS V6.2.
SN-PBXNP-AC
PCI Token Ring Adapter. Uses one PCI slot. Digital UNIX V3.2G or V4.0B supports two per PCI,
maximum two per system. Minimum system console support for this adapter is V4.0 AXP CD release. Requires BC26M cable.
PBXDA-AA
PCI Asynchronous 4-port Communication Adapter. OpenVMS v6.2-1H3 supports two per PCI,
maximum two per system.
PBXDA-AB
PCI Asynchronous 8-port Communication Adapter. OpenVMS v6.2-1H3 supports two per PCI,
maximum two per system.
DE500-AA
Fast Ethernet (100 Mbit) PCI Adapter (uses one PCI slot). DIGITAL UNIX V3.2C and OpenVMS
V6.2 and 7.1 support. Up to eight per PCI, maximum eight per system.
DEFPA-AB
FDDIcontroller Fiber—Single attachment station MultiMode Fiber (uses one PCI slot).
OpenVMS and DIGITAL UNIX support six per DWLPB, maximum six per system with DIGITAL UNIX V3.2G and OpenVMS V6.2-1H3 operating system releases. Requires BN34x “SC” type connecting cable.
DEFPA -DB
FDDIcontroller Fiber—Dual attachment station MultiMode Fiber (uses one PCI slot). OpenVMS
and DIGITAL UNIX support six per DWLPB, maximum six per system with DIGITAL UNIX V3.2G and OpenVMS V6.2-1H3 operating system releases. Requires BN34x “SC” type connecting cable.
BN34A-xx BN34B-xx BN34D-xx DEFPA-MB
MultiMode Fiber-Optic Duplex cable“SC” connector to “ST” connector MultiMode Fiber-Optic Duplex cable“SC” connector to “SC” connector MultiMode Fiber-Optic Duplex cable“SC” connector to “MIC” connector FDDIcontroller Copper—Dual attachment station UTP (uses one PCI slot). OpenVMS and
DIGITAL UNIX support six per DWLPB, maximum six per system with DIGITAL UNIX V3.2G and OpenVMS V6.2-1H3 operating system releases. . Requires BN26x or BN25H connecting cables.
DEFPA-UB
FDDIcontroller Copper—Single attachment station UTP (uses one PCI slot). OpenVMS and
DIGITAL UNIX support six per DWLPB, maximum six per system with DIGITAL UNIX V3.2G and OpenVMS V6.2-1H3 operating system releases. . Requires BN26x or BN25H connecting cables.
BN26M-xx BN26S-xx BN25H-03 DGLPB-AB
8-pin MP to 8-pin MP, screened, EIA/TIA Category 5 cable 8-pin MP to 8-pin MP, screened, crossover, EIA/TIA Category 5 cable 3-meter Unshielded twisted pair RJ45 connectors ATMworks 350 ATM PCI bus adapter (uses one PCI slot). DIGITAL UNIX V4.0a supports four
per PCI, maximum four per system.
3.218 Alpha Servers
Page 14
AlphaServer 8400
Step 8—Networks and Communications
LAN Communications Controllers
Requires DWLPB-AA and KFE70-AA, EISA bridge module set.

See EISA Bus IRQ Address Table.

DNSES-AA
Synchronous Communications Controller (uses one EISA slot). DIGITAL UNIX supports two per
EISA based
(continued
EISA, maximum two per system. OpenVMS supports one per EISA, maximum one per system. Requires a BC19x cable.
BC19B-02 BC19D-02 BC19E-02 BC19F-02 DW300-AA
EIA-422-A/V.11 adapter cable, can be extended with BC55D-33 EIA-232-D/V.24 adapter cable, can be extended with BC22F-xx EIA-423-A/V.10 adapter cable, can be extended with BC55D-33 V.35 adapter cable, can be extended with BC19L-25 Token Ring Adapter (uses one EISA slot). DIGITAL UNIX and OpenVMS V6.2 plus remedial
stream TIMA kit (TPPR 614) support one per EISA, maximum one per system. Requires BN26M cable.
BN26M-xx CXI01-AA
802.5/Token Ring twisted-pair cable; 8-pin MP to 8-pin MP, screened, EIA/TIA Category 5 cable. Digiboard Asynchronous Xem/ISA Multiport Serial Card with 16 RJ45 PORTS/Xem Port (uses
one EISA slot). DIGITAL UNIX only, supports one per EISA, maximum one CXI01-AA/AD per system.
CXI01-AB
Digiboard PORTS/Xem, 16 RJ45 Port Concentrator—mounts separately from PCI bus.
Maximum of three CXI01-AB can be attached to CXI01-AA, provides up to 48 additional ports. DIGITAL UNIX only.
CXI01-AD
Digiboard Asynchronous EPC/X Multiport Serial Card with 16 RJ45 Port EPC/CON-16 Concentrator (uses one EISA slot). DIGITAL UNIX one per EISA, maximum one CXI01-AA/AD
per system. DIGITAL UNIX only.
CXI01-AE
Digiboard EPC/CON-16 Concentrator mounts separate from PCI bus. Maximum three CXI01-AE
can be attached to the CXI01-AD provides up to 48 additional ports. DIGITAL UNIX only.
CXI01-AC CXI01-AF
Digiboard RJ45 to DB25 Male Converter Digiboard RJ45 to DECMJ11 Adapter—8 per package
LAN Communications Controllers
DEMNA-M
802.3/Ethernet controller XMI-to-Ethernet adapter, (uses one XMI slot). OpenVMS supports four
XMI based
per XMI, maximum six per system. DIGITAL UNIX supports six per XMI, maximum eight per system.
CK-DEMNA-KN DEMFA-AA
DEMNA cabinet kit, required with DEMNA-M DEC FDDIcontroller 400 XMI-to-FDDI adapter, Single attachment station with fiber MIC
connector; (uses one XMI slot). OpenVMS supports four per XMI, maximum four per system. DIGITAL UNIX supports seven per XMI, maximum eight per system.
Local and Wide Area Communications Servers
Each communications server requires 802.3/Ethernet connection. Depending on the server selected, either ThinWire BNC­type connection (e.g., BC16M cable) or thick wire 15-pin AUI transceiver cable (e.g., BNE3x) is required. Additional items also required—see Network Products Guide for ordering information.
Network Connectivity Products
See Network Products Guide for details.
Alpha Servers 3.219
Page 15
AlphaServer 8400
Step 8a—MEMORY CHANNEL Controller
DIGITAL UNIX Systems

Require DIGITAL UNIX V3.2E (DIGITAL UNIX V3.2D plus TruCluster software or MEMORY CHANNEL Driver software).

Each system node in a MEMORY CHANNEL cluster requires a software license.

Servers in a compute-server array require a DIGITAL UNIX Driver for MEMORY CHANNEL License.
OpenVMS Systems

Require OpenVMS V7.1 and OpenVMS Cluster License.

On systems with DWLPA-AA/AB/BA/BB and no other PCI option(s) and/or KFE70-AA, a maximum of two CCMAA-BA modules are supported.

On systems with DWLPA-AA/AB/BA/BB and any PCI option(s) and/or KFE70-AA, a maximum of one CCMAA-BA module is supported.
MEMORY CHANNEL requirements for currently installed AlphaServer 8400 systems:

Servers in a TruCluster high-availability environment require a license for TruCluster for DIGITAL UNIX.

The following options are not currently supported with MEMORY CHANNEL: DJ-ML200, DNSES-AA, CIPCA, CIXCD

DWLPB-AA/AB/BA/BB option does not have the restrictions of the DWLPA-AA/AB/BA/BB.

DNSES-AA is not currently supported with MEMORY CHANNEL.

Console firmware at revision V2.3 or higher.

CCMAA-BA Adapter must be installed in slots 0-7 of a DWLPA-AA/AB/BA/BB PCI; no restriction for DWLPB­AA/AB/BA/BB PCI bus.

For two-system nodes, order one CCMAA-BA per system and one BC12N-10 cable to connect them.

For three or more system nodes, order CCMHA-AA (MEMORY CHANNEL Hub) one CCMAA-BA and one BC12N­10 cable per system node.

CCMHA-AA (MEMORY CHANNEL Hub) is configured with four CCMLA-AA Line Cards and supports up to four nodes. Expansion up to eight system nodes can be achieved by adding up to four additional CCMLA-AA Line Cards, except TruCluster Production Server configurations.
CCMAA-BA CCMHA-AA CCMLA-AA BC12N-10 QB-3RLAQ-AA QB-4ZCAQ-AA QL-MUZAQ-AA
PCI to MEMORY CHANNEL controllerMaximum two supported MEMORY CHANNEL Hub with 4 Line Cards MEMORY CHANNEL Line Card for use with MEMORY CHANNEL Hub (CCMHA-AA) MEMORY CHANNEL Cable TruCluster Software for DIGITAL UNIX DIGITAL UNIX Driver for MEMORY CHANNEL license OpenVMS Cluster license for Alpha systems
CCMHA-AA, MEMORY CHANNEL Hub, includes BN19P-2E line cord for Canada, Japan, US operation. For other regions, order one of the following:
BN19A-2E BN19S-2E BN19C-2E BN18L-2E BN19E-2E BN24X-2E BN19K-2E BN19H-2E
Ireland, United Kingdom Egypt, India Central Europe Israel Switzerland Italy Denmark Australia, New Zealand
3.220 Alpha Servers
Page 16
AlphaServer 8400
Step 9—Console Terminal

Console terminal with EIA-232 25-pin DSUB connector and printer required unless otherwise available.

Shielded console cable is included for connection to the console terminal.
VT510-xx LA30N-xx LK461-xx/LK46W-xx
VT510 terminal LA30 printer Keyboard
Step 10—Expansion—System Cabinet and I/O Expansion Cabinet
Step 10a—System Cabinet

System Cabinet includes one three-phase power regulator with space for two additional three-phase power regulators. System cabinets shipped after June 1996 (H9F00-FC/FD/FE Rev B03 or greater) include the H7263-AC/AD non-battery back-up ready power regulator. See Step 11 for power expansion options for these system cabinets.

Maximum four I/O channels per cabinet allowed. PCI and XMI plug-in units each require one I/O channel connection.

Four lower expansion bays are available for plug-in units. The lower bays accommodate plug-in units as follows.
AlphaServer 8400 System Cabinet
Expansion Bay
Location
Lower Lower Lower Lower
Disk plug-in unit (BA660-AB) XMI plug-in unit (DWLMA-AA) Battery plug-in unit(H7237-AA/AC/CA/CB) PCI plug-in unit (DWLPB-AA)
Step 10b—I/O Expansion Cabinet
Plug-In Unit
(PIU) Quantity Expansion Bays Occupied
Four maximum Two maximum One maximum Two maximum
Front or Rear Front and Rear Front and Rear Rear only

I/O Expansion Cabinet includes one three-phase power regulator
- Provides space for two additional three-phase power regulators

H9F00-BA/BB/BC Rev D03 or later cabinets include the H7263-AC or H7263-AD non-BBU capable power regulator. Refer to Step 11 for expansion options.
H9F00-BA/BB/BC
I/O expansion cabinetThree phase power, maximum two per system. Note: -BA = 60 Hz, 208V, -BB = 50 Hz, 380/416V, -BC = 50/60 Hz, 202V.

Expansion cabinet can be configured to hold all disk plug-in units or combination of disk plug-in units and PCI or XMI plug-in units.
- Six expansion bays—two upper and four lower—are available for plug-in units. The two upper bays accommodate maximum of two disk plug-in units. The four lower bays accommodate plug-in units as follows:
Expansion Bay
Location
Upper Lower Lower Lower Lower
Step 11

System Cabinet and Expansion Cabinets must be same type; either three-phase or single-phase. Mixing of three-phase
Disk plug-in unit (BA660-AB) Disk plug-in unit (BA660-AB) PCI plug-in unit (DWLPB-AB) XMI plug-in unit (DWLMA-BA) Battery plug-in unit(H7237-AA/AC/CA/CB)
Power Expansion Components
Plug-In Unit
(PIU) Quantity Expansion Bays Occupied
Two maximum Four maximum Two maximum Two maximum One maximum
Front or Rear Front or Rear Rear only Front and Rear Front and Rear
and single-phase cabinets in same system configuration is not allowed.

Determine the need for adding second power regulator by filling in the EPU- Power Configuration Table. Note: The Power Configuration Table provides a manual method for determining the need of second power regulator. Equivalent power unit (EPU) is an equivalent value of power used (48 VDC) by each option.
Alpha Servers 3.221
Page 17
AlphaServer 8400
Step 11a
Three-Phase Expansion Components
For new system orders, or for systems shipped after June 1996:

Select additional H7263-AC/AD for systems that do not require battery back-up option
- If EPU value of 1st regulator is exceeded
- If N+1 redundancy is required
- If 2nd or 3rd power regulator is required

Select H7237-CA/CB for systems that require battery back-up option (Factory Installed)
- Includes battery plug-in-unit, one H7263-AA/AB power regulator and batteries for battery backup/UPS capability. Must be ordered at time of system purchase if BBU functionality is required. The H7263-AA/AB mounts alongside the standard H7263-AC/AD.

Select H7238-BA/BB for additional battery UPS (Factory Installed)
- Includes H7263-AA/AB and H7238-AA 4-pack battery option for second and third regulator support
For systems shipped prior to June 1996, select the following power options
H7263-AA/AB*
Three-Phase 48 VDC power regulator with BBU capability—maximum three per cabinet. Second regulator may be required to supply adequate power depending on configuration. Third regulator assures N+1 power redundancy and higher availability in the event of power regulator failure. See Power Configuration Table.
H7237-AA*
Battery plug-in unit with batteries for battery backup/UPS capability—maximum one per cabinet. Use in system cabinet and/or H9F00-BA/BB/BC expansion cabinet. Includes four batteries to support 48 V power regulator and cabling for additional H7238-AA battery options.
H7238-AA*
4-pack battery option—one required per optional 48 V power regulator to support battery backup/UPS capability. For use only with the H7237-AA.
* Will ship as
spare
from Manufacturing
Battery backup I/O expansion cabinet
H9B00-AF
Battery option for I/O Expansion Cabinet—fully loaded battery cabinet supports three power regulators, provides for 60 minutes uninterruptible power (UPS). Maximum one per H9F00­BA/BB/BC expansion cabinet.
Step 11b

Includes new AC distribution box with attached line cord, DC subrack, one three-phase 48VDC power regulator.

If single phase power system has two power regulators, an additional three-phase 48VDC power regulator is required.
H7268-AA/AB
Single-Phase to Three-Phase Power Upgrade
Single-Phase to Three-Phase Upgrade Kit, Converts system to three-phase power subsystem.
-AA= 60 Hz, 208V, -AB = 50 Hz, 380/416V
Step 11c

Provides N+1 power for BA660-AB, BA661-AA StorageWorks PIUs/shelves.

Occupies one slot in StorageWorks shelf.
BA35X-HG
Power Option for StorageWorks Shelves in StorageWorks Plug-in-Units
48V DC 150W Redundant Power Supply for BA660-AB, BA661-AA—includes 48VDC jumper cable for connecting to first power supply in StorageWorks shelf.
3.222 Alpha Servers
Page 18
AlphaServer 8400
Step 12—Software
Select user licenses and additional software as required. Media and documentation recommended for first system on site.
Software Processor Code = Q DIGITAL UNIX Concurrent Use Licenses
DIGITAL UNIX Concurrent Use licenses are not specific to a single system and can be moved from one system to another at user discretion.
Note: DIGITAL UNIX 8400 5/440 Mhz CPU Base Servers and Expanded Base Servers include traditional unlimited user
license.
QL-MT7AM-3B QL-MT7AM-3C QL-MT7AM-3D QL-MT7AM-3E QL-MT7AM-3F QL-MT7AM-3G QL-MT7AM-3H QL-MT7AQ-AA *
DIGITAL UNIX Concurrent Use 1-user license DIGITAL UNIX Concurrent Use 2-user license DIGITAL UNIX Concurrent Use 4-user license DIGITAL UNIX Concurrent Use 8-user license DIGITAL UNIX Concurrent Use 16-user license DIGITAL UNIX Concurrent Use 32-user license DIGITAL UNIX Concurrent Use 64-user license DIGITAL UNIX Traditional unlimited user license
QL-MT5AQ-AA QL-MT6AQ-AA *
QL-MTJAQ-AA QL-MTKAQ-AA
QB-05SAQ-AA
DIGITAL UNIX developer's extension license DIGITAL UNIX server extension license
DECnet/OSI end-system license DECnet/OSI extended function license
DECsafe Available Server license and documentation (DIGITAL UNIX only). Media available on layered product CD-ROM. KZMSA or KZPSA adapter required.
* Included in 5/440 DIGITAL UNIX Base and Expanded Base Servers.
DIGITAL UNIX Media and Documentation
QA-MT4AA-H8
DIGITAL UNIX media and on-line documentation (base system, complementary products) on CD­ROM
QA-MT4AA-GZ QA-MT4AB-GZ QA-MT5AA-GZ QA-MT6AA-GZ
DIGITAL UNIX full hardcopy documentation DIGITAL UNIX end user hardcopy documentation subkit DIGITAL UNIX developer’s extension hardcopy documentation subkit DIGITAL UNIX server extension hardcopy documentation subkit
OpenVMS Concurrent Use Licenses
OpenVMS Concurrent Use license provide the right to interactively use the operating system by the specified number of concurrent users on a designated OpenVMS system. OpenVMS Concurrent Use licenses can be moved from one system to another at user discretion and can be shared in a mixed OpenVMS VAX and OpenVMS Alpha cluster.
QL-MT3AA-3B QL-MT3AA-3C QL-MT3AA-3D QL-MT3AA-3E QL-MT3AA-3F QL-MT3AA-3G QL-MT3AA-3H QL-MT3AA-3J QL-MT3AA-3K QL-MT2AQ-AA
OpenVMS Concurrent Use 1-user license OpenVMS Concurrent Use 2-user license OpenVMS Concurrent Use 4-user license OpenVMS Concurrent Use 8-user license OpenVMS Concurrent Use 16-user license OpenVMS Concurrent Use 32-user license OpenVMS Concurrent Use 64-user license OpenVMS Concurrent Use 128-user license OpenVMS Concurrent Use 256-user license OpenVMS Traditional unlimited user license
Alpha Servers 3.223
Page 19
AlphaServer 8400
Step 12—Software
(continued)
OpenVMS
QL-MTFAQ-AA QL-MTHAQ-AA QL-MUZAQ-AA
DECnet/OSI end-system license DECnet/OSI extended function license OpenVMS cluster software license. Required with each system that connects to an OpenVMS
cluster.
OpenVMS Media and Documentation
QA-MT1AA-H8 QA-09SAA-GZ QA-001AA-GZ
OpenVMS media and documentation on CD-ROM OpenVMS base hardcopy documentation OpenVMS full hardcopy documentation
Layered Products CD-ROM
QA-054AA-H8 QA-03XAA-H8
Layered products media and documentation for DIGITAL UNIX Layered products media and documentation for OpenVMS
Open VMS Layered Products CD-ROM
QA-03XAA-H8 *
* Includes DIGITAL Enteprise Integration Server for OpenVMS media and documentation
Layered products media and documentation for OpenVMS
DIGITAL Enterprise Integration Package—included in 5/440 Base Servers and Expanded Base Servers
QA-5LVAA-H8
DIGITAL Enterprise Integration Server for OpenVMS media and documentation
DIGITAL NAS Base Server 200 Software
DIGITAL NAS 200 Base Server software included with base 5/300 MHz AlphaServer 8400 systems. Media available on layered product CD-ROM.
Step 13—Hardware and Software Supplemental Support Services
Hardware—Americas and Asia Pacific only

Systems include one-year hardware warranty, on-site, same day, 4-hour response time.

Select optional Hardware Supplemental Support Services if required.
AlphaServer 8400
Two CPUs with less than 2 GB memory Two CPUs with 2 GB memory
FM-4Y4HR-36 FM-4Z4HR-36
FM-4Y512-36 FM-4Z512-36 FM-4Y616-36 FM-4Z616-36 FM-4Y724-36 FM-4Z724-36
FM-4Y4HR-60 FM-4Z4HR-60
FM-4Y512-60 FM-4Z512-60 FM-4Y616-60 FM-4Z616-60 FM-4Y724-60 FM-4Z724-60
Years 1-3, 5 x 9, 4-hour response time Years 1-3, 5 x 12, 4-hour response time Years 1-3, 6 x 16, 4-hour response time Years 1-3, 7 x 24, 4-hour response time Years 1-5, 5 x 9, 4-hour response time Years 1-5, 5 x 12, 4-hour response time Years 1-5, 6 x 16, 4-hour response time Years 1-5, 7 x 24, 4-hour response time
3.224 Alpha Servers
Page 20
AlphaServer 8400
Step 13—Hardware and Software Supplemental Support Services
(continued)
Software—Americas and Asia Pacific only

Systems include 90-day Conformance to SPD and Telephone Advisory Support. Select optional Software Supplemental Support Services, if required.

Software service upgrades for DIGITAL UNIX and OpenVMS include advisory and remedial software support with new version license rights for operating system and DIGITAL NAS Base Server 200 for the time period indicated.
AlphaServer 8400 Two CPU Systems FM-84DOS-12 FM-84DOS-36 FM-84DOS-60 FM-84DVM-12 FM-84DVM-36 FM-84DVM-60
12-month Software Supplemental Support for DIGITAL UNIX two CPU systems 36-month Software Supplemental Support for DIGITAL UNIX two CPU systems 60-month Software Supplemental Support for DIGITAL UNIX two CPU systems 12-month Software Supplemental Support for OpenVMS two CPU systems 36-month Software Supplemental Support for OpenVMS two CPU systems 60-month Software Supplemental Support for OpenVMS two CPU systems
Step 13a—Hardware and Software Supplemental Support Services (Europe only)
Europe does not have specific part numbers for Hardware and Software Supplemental Support Services. Prices can be quoted using the Excelerator tool; contact MCS Sales in your country for information on Hardware and Software Supplemental Support Services.
Alpha Servers 3.225
Page 21
AlphaServer 8400 Power Configuration Table
AlphaServer 8400 EPU (Equivalent Power Units)

Second power regulator may be needed to supply additional 48V power to the system.

Mixing of three-phase and single-phase power regulators in system configuration is not allowed.

Use chart to determine need for second power regulator.

If EPU is greater than 80, order second power regulator (three-phase regulatorH7263-AC/AD) or H7263-AA/AB if
Power Configuration Table
BBU is required).

EPU must not exceed 180.
Options
Base system includes power regulator, CPU module, system I/O module, memory module
I/O expansion cabinet (H9F00-BA/BB/BC) includes one power regulator
Additional 5/300 CPU modules751P1-AX, 751P2-AX Additional 5/300 CPU modules752P1-AX, 752P2-AX Additional 5/350 CPU modules753P1-AX, 753P2-AX Additional 5/350 CPU modules754P1-AX, 754P2-AX Additional dual 5/440 CPU modules—756P1-AX, 756P2-AX KFTIA-AA System I/O module KFTHA-AA System I/O module MS7CC-BA 128 MB memory MS7CC-CA 256 MB memory MS7CC-DA 512 MB memory MS7CC-EA 1 GB memory MS7CC-FA 2 GB memory MS7CC-GA 4 GB memory
Add PCI options
DWLPB-AA/AB/BA/BB KZPSA-BB KZPSC-AA/BA, KZPAC-AA/CA/CB DE435-AA, DE450-AA, DE500-XA, DE500-AA DEFPA-AB/DB/UB/MB KFE70-AA
Add EISA options
DNSES-AA DW300-AA CXI01-AA/AD
Add XMI options
DWLMA XMI plug-in unit KZMSA-AB XMI SCSI controller KFMSB-AA DSSI disk/tape adapter CIXCD-AC XMI CI controller DEMNA-M XMI Ethernet controller DEMFA-AA XMI FDDI adapter
Disk and Tape options
8-bit SCSI disk drives 16-bit SCSI disk drives TLZ07, TLZ09, TLZ9L, TLZ15-VA SCSI tape drive TZ86, TZ87, TZ88 -VA SCSI tape drive DWZZA-VA/DWZZB-VW SCSI signal converter
Total
EPU Values
System Cabinet Options Quantity
30 1 30
11 13 12 14
8 4 3 5 5 5 5 5 5
1 1 1 1 1 1
1 1 1
4 3 3 4 3 5
1 1 1 3 0
Total
EPU
(Qty times
EPU)
EPU Values
Expansion
Cabinet Options Quantity
Total
EPU
(Qty times
EPU)
10
Note: Depending on configuration, system offers integral UPS capability that supports all in-cabinet components for at
least 11 minutes. If UPS support is required for external devices, e.g., console terminals, terminal servers, printers, and modems, a universal UPS can be ordered separately.
3.226 Alpha Servers
Page 22
AlphaServer 8400
Optional Controller Configuration Table
With multiple adapters that provide the same interface available on different I/O buses (PCI or XMI), it is possible to exceed operating system limit on number of ports supported for that interface. Follow these guidelines for maximum number of ports that each operating system will support. Fill in table under the relevant area, add up the number of controllers/ports available, and verify the operating system limits will not be exceeded. Do not exceed these values.
C Total Ports
(A * B)
DIGITAL
UNIX Limit
OpenVMS
Limit
32 26
88
88
Option Name SCSI Options
Included
KFTIA-AA
I/O module, one single-ended and three FWD
SCSI ports* Additional
KFTIA-AA
I/O module, one single-ended and three
FWD SCSI ports
KZPSA-BB KZMSA-AB Add column “C”—
PCI fast wide differential SCSI adapter 1
XMI fast single-ended SCSI adapter 2
must be less than or equal to value listed under
operating system to be used
802.3/Ethernet Options Included Additional
DE435-AA DEMNA-M Add column “C”—
KFTIA-AA
KFTIA-AA
I/O module, two 802.3/Ethernet ports* 2 1 2
I/O module, two 802.3/Ethernet ports 2
PCI 802.3/Ethernet controller,
XMI 802.3/Ethernet controller 1
must be less than or equal to value listed under
operating system to be used. FDDI Options Included
installed ( Additional
installed (
KFTIA-AA
I/O module, optional FDDI daughter card
DEFPZ-AA/UA
KFTIA-AA
DEFPZ-AA/UA
I/O module, optional FDDI daughter card
DEFPA-AB/-DB/-UB/MB DEMFA-AA Add column “C”—
XMI FDDI controller 1
must be less than or equal to value listed under
operating system to be used.
Number
Ports/Buses
.
DE450, DE500
)*
)
PCI FDDI controller, one port each 1
A
B
Number
of
of
Options
414
4
1
1
1
EISA Bus IRQ Address Table Configuration Rules and Information

EISA Bus IRQ address assignments are for DIGITAL UNIX and OpenVMS systems only.

In some cases, the maximum number of each supported device is less than the number of EISA bus addresses available; this is due to other limitations.

Only one device can occupy any given IRQ address; if multiples of a device are configured, each device occupies separate address.

Match each device to one available address. (Note: With the table as a worksheet, fill in “0” for each device; fill in only one “0” per column.)

Actual IRQ address assignment will be made by the EISA Configuration Utility (ECU), which is run during system manufacture, or in the installed system if the EISA bus is reconfigured.
EISA Bus IRQ Addresses Maximum of Each Supported Option DNSES-AA DW300-AA CXI01-AA CXI01-AD
Table Codes:
0
= address is available for device,
57891011121415OpenVMS DIGITAL UNIX ––0000000 1 2
0––000––0 1 1 NA NA NA NA NA NA NA NA NA 1 1 NA NA NA NA NA NA NA NA NA 1 1
= address not available for device
NA
= Not Applicable
Alpha Servers 3.227
Page 23
System Diagram
AlphaServer 8400
CD-ROM
High-speed System Interconnect Bus
1-14 CPUs Memory I/O Port
Expansion Bay for:
PCI I/O Channel BA655 PIU
BA660 PIU One BA660 Storage­Works PIU included
48-Volt
Power Regu-
lator
Cooling Assembly
Expansion Bay for:
XMI I/O Channel PCI I/O Channel BA655 PIU BA660 PIU Batteries for UPS
System Cabinet I/O Expansion Cabinet
Note:
Three-Phase Power Systems support up to three Power Regulators.
Operator
Control
Panel
Space for Additional
Power
Regulators
Space for
one or two
BA655 or
BA660 PIUs
Cooling Assembly
Expansion Bay for:
XMI I/O Channel PCI I/O Channel BA655 PIU BA660 PIU Batteries for UPS
48-Volt
Power Regu-
Space for Additional
Power
Regulators
lator
Expansion Bay for:
XMI I/O Channel PCI I/O Channel BA655 PIU BA660 PIU Batteries for UPS
BU-3310A
5.25-in. Devices
3.5-in. Devices
StorageWorks Plug-in Units (each occupies one bay)
XMI Plug-in Unit (occupies two bays)
PCI Plug-in Unit
48-V Pwr. Reg.
Cooling Assembly
Two
Expansion
Bays
Space
for
Additional
Power
Regulators
Two
Expansion
Bays
PCI Plug-in Unit
Battery Plug-in Unit (occupies two bays)
BU-3482
3.228 Alpha Servers
Page 24
Specifications
AlphaServer 8400
Physical Characteristics Operating Shipping
Height Width Depth
170.0 cm (67.0 in.)
80.0 cm (31.5 in.)
87.5 cm (34.4 in.) Weight, full configuration Without batteries With batteries
408 kg (900 lb.) 545 kg (1200 lb.)
Clearances Operating Service
Front Rear Sides
1.0 m (40 in.)
1.0 m (40 in.)
0
Environmental Operating Non-Operating
Temperature Humidity Altitude Vibration Heat dissipation
1
15° to 28°C (59° to 82°F) 20% to 80% 02.4 km (08000 ft) 222 Hz @ 0.01"da minimum
Minimally configured system
(system cabinet) 3,400 Btu/hr, 1,000 W
Fully configured system
2
(system cabinet) 15,700 Btu/hr, 4,600 W
Fully configured system
3
(system cabinet with two I/O expansion cabinets) 30,600 Btu/hr, 9,000 W
Regulatory
Agency approvals UL Listed to UL1950
UL Classified to IEC950 CSA Certified to CAN/CSA-C22.2, No. 950-M89 FCC Part 15 (Class A) CE Declaration #1171
Reviewed to AS 3260, Australian Standard
EN 60950, European Norm
Power Requirements
1
Three-Phase Power Subsystem2US/Canada Europe/AP Japan Nominal voltage
Frequency range Phases
120/208 V 5060 Hz 3-phase star 4-wire N-GND
Maximum input current/phase Surge current Rating Power cap (system) Receptacle (site) (Industry equivalent) PCS/PDS/PDU/UPS cable
1 Minimally configured system contains one regulator, one CPU module, one memory module, one KFTIA-AA
module, CD-ROM, and RZ28 disk drive.
2 Fully configured system contains two power regulators, four CPU modules, three memory modules, two
System I/O modules, one DWLPB-AA, one DWLPB-BA, three BA655-AB, CD-ROM, 36 RZ28 drives.
3 Fully configured system and expansion cabinets consist of the above “fully configured system” and two
expansion cabinets which each contain one DWLPB-AB, one DWLPB-BB, six KZPSA-BB, five BA655-AB, and 60 RZ28 drives.
4 Receptacle type is Hubbell 516R6 or equivalent
24 A rms 50 A peak 30 A DEC 12-12314-00 DEC 12-12315-01 NEMA L21-30R BC24W
380415 V 5060 Hz 3-phase star 4-wire N-GND
12.8 A rms 50 A peak 16 A DEC 12-30333-02 See footnote 4 IEC 309 BN29X
195.0 cm (76.7 in.)
109.5 cm (43.1 in.)
121.0 cm (47.5 in.) 448 kg (1000 lb.)
585 kg (1300 lb.)
1.5 m (59 in.)
1.0 m (40 in.) 0
40° to 66°C (40° to 151°F) 10% to 95% 9,100 m (30,000 ft) 22500 Hz @ 0.25g max.
1
202 V 5060 Hz 3-phase delta 4-wire mid-GND or 3-wire junction GND 24 A rms 50 A peak 30 A DEC 12-12314-00 DEC 12-12315-01 NEMA L21-30R BC24W
Alpha Servers 3.229
Page 25
AlphaServer 8400
UPS Solutions
For complete protection, UPS products should be used with data line surge protectors. See TVSS section of Environmental Products Chapter.
4N-GA249-AB 2 wire modem wall plug in 4N-GA249-CA 10BaseT wall plug in 4N-GA510-BF ThinWire device port 4N-GA245-xx Din rail and modules up to 32 ports
Receptacle Module for Plug-in Connection UPS Model 60 HZ 50 HZ AlphaServer 8400 External Storage 4N-AEAAL-BA 4N-AEACK-BN 4N-AEAAN-BA (60 Hz)
4N-AEACM-BN
Hardwired Single phase None, SW500, or Expansion Cabinet Hardwired Single phase SW800
4N-AEAAN-BE (50 Hz) 4N-AEAAN-BA (60 Hz)
4N-AEACM-BK
Hardwired Three Phase None
4N-AEAAN-BE (50 Hz) 4N-AEAAN-BA (60 Hz)
4N-AEACM-PA
Hardwired Three Phase SW800 or Expansion Cabinet
4N-AEAAN-BE (50 Hz)
UPS Models
4N-AEAAL-BA
PUPS plus 10kVA (7kW), single-phase, 50/60Hz, 176-276V in, 200-240V out, 9 minutes battery at full load; hardwired with optional plug-in output receptacle modules.
4N-AEAAN-BA
PUPS plus 15kVA (10kW), three-phase, 50/60Hz, 176-256V in, 200-240V out, 10 minutes battery at full load; hardwired with optional plug-in output receptacle modules.
4N-AEAAN-BE
PUPS plus 15kVA (10kW), three-phase, 50/60Hz, International model rated 380/415V in, 380/415/220V out; hardwired input/output.
Options
4N-AEACK-BN 4N-AEACM-BK 4N-AEACM-BN 4N-AEACM-PA
PUPS plus 10kVA receptacle module (3) L6-30R, (3) 5-20R2, (2) L5-20R PUPS plus 15kVA receptacle module (2) L21-30R, (3) 5-20R2 PUPS plus 15kVA receptacle module (2) L6-30R, (2) L21-30R, (1) 5-20R2 PUPS plus 15kVA dual receptacle module:
Module 1: (2) L21-30R and conduit kit for connecting Module 1 to Module 2 Module 2: (2) L21-30R, (3) 5-20R2
UPS Monitoring and Unattended Shutdown Software (for above UPS systems only)
Note: Power Management software is included in ServerWORKS Manager kits shipping with all AlphaServers. Cable kit required, select UPS Communications Cable Kit
DIGITAL UNIX 4N-ONLIN-NT 4N-AEAEO-Dx 4N-AEAEO-Dx
1
2
2
OpenVMS
4N-ONLIS-FE 4N-JMIU4-AB 4N-AEAEO-Dx
3
4 port
2
Hardware Option for multi-systems on one UPS Option for SNMP/ ServerWORKS Manager interface
UPS Communications Cable Kit
1
Ala Carte Software kits available for existing installations
DIGITAL UNIX 4N-AEAES-AK 4N-AEAES-EM 4N-AEAES-AK 4N-AEAES-FM 4N-AEAES-BK 4N-JMMCR-AA
4N-AEAEO-Dx 4N-AEAEO-Dx
1. Connect-UPS network adapter required for operation on AlphaServer 8400 DIGITAL UNIX systems. See footnote 2.
2. Connect-UPS network adapter; D* denotes Twisted Pair / ThinWire = DA/DC (60Hz; 120V NEMA); DB/DD (50Hz: 240V IEC)
3. Multi-port interface kit with splitter cable to interface with network adapter and local shutdown signal from UPS. Kits may be daisy
chained, kits include software
4. Same as 3 above except 2 port for basic shutdown and one smart monitoring port
1
OpenVMS
4N-JMIU4-AA 4N-JMIU8-AA
4
2 port
4 port
8 port
Prestige (single system) PUPS Plus (single system) Multi-systems on one UPS
Network Monitoring
3.230 Alpha Servers
Loading...