The AlphaServer 8400—using the world’s fastest microprocessors, the Alpha
21164 300 MHz or 440 MHz CPUs—is the world’s fastest and highest capacity
enterprise server. It is the solution for the most demanding business problems.
ServerWORKS Manager provides advanced server and network management
capabilities and is supplied with all AlphaServer systems. SNMP (Simple
Network Management Protocol) enables information to pass from the managed
system to the console for Digital UNIX, Windows NT, and OpenVMS for
AlphaServers. Using ServerWORKS, the system manager can build and view
topological maps of the network. Detailed server information is viewable,
including system, network, storage, and environmental information. All
AlphaServer systems are also supplied with management tools to complement
ServerWORKS Manager. These include StorageWorks Command Console for
storage management. For more information, see the "StorageWorks Software"
section of this catalog.
The AlphaServer 8400 5/300 supports up to 12 processors with 8 GB memory,
two processors with 28 GB of memory, and any combination between these
maximums, with 1.2 GB/sec (peak) of I/O.
The AlphaServer 8400 5/440 supports up to 14 processors with 4 GB memory,
two processors with 28 GB of memory, and any combination between these
maximums, with 1.2 GB/sec (peak) of I/O.
The AlphaServer 8400 supports the DIGITAL UNIX and OpenVMS operating
systems. For investment protection, DEC and VAX 7000 products can be
upgraded to the AlphaServer 8400 in a few hours. The AlphaServer 8400
platform is designed to take full advantage of future generations of Alpha
microprocessors.
The AlphaServer 8400 enterprise servers join the AlphaServer line, with high
performance PCI I/O, providing up to 144 PCI slots on 12 different physical PCI
buses. The AlphaServer 8400 includes a one year hardware warranty, on-site, 4
hour response, five days per week. System installation is included with the
AlphaServer 8400 5/440 system.
DIGITAL believes the information in this publication is accurate as of its publication date; such information is subject to change without notice. Digital is
not responsible for any inadvertent errors.
DIGITAL conducts its business in a manner that conserves the environment and protects the safety and health of its employees, customers, and the
community.
DIGITAL, and the DIGITAL logo are trademarks of Digital Equipment Corporation.
Printed in USA. Copyright 1997 Digital Equipment Corporation. All rights reserved.
3.206 Alpha Servers
Step 1—Base Systems
AlphaServer 8400
AlphaServer 8400 5/300 Systems require
- DIGITAL UNIX V3.2B or later, and OpenVMS V6.2
or later
AlphaServer 8400 5/440 Systems require
- DIGITAL UNIX V3.2G or DIGITAL UNIX V4.0A,
or OpenVMS V6.2-1H3 or V7.1
Software media and documentation required for first
system on site. See Step 13 for ordering information.
Console terminal required to install system. See Step 11
unless terminal is available on site.
System includes 9 slot centerplane—three slots used by
the CPU module, memory module, and system I/O
module (KFTIA-AA).
- Six slots available for additional CPU, memory, or
system I/O module(s).
CD-ROM connected via single-ended SCSI-2 port on
KFTIA-AA system I/O module.
2 GB or 4.3 GB SCSI system disk drive and DWZZBVW are located in BA660-AB StorageWorks shelf and
connected via Fast Wide Differential (FWD) port on
KFTIA-AA system I/O module, using one CK-KFTIAAA.
For recommended power protection see section after
system specifications. UPS Power Management
Software is included in ServerWORKS Manager kit.
Software communicates with recommended UPS.
AlphaServer 8400 Base Servers include
Processor module with two Alpha microprocessor
21164 5/300 MHz or 5/440 MHz CPUs; each CPU
includes 4 MB back-up cache
System I/O module (KFTIA-AA) includes
- I/O channel
- Two twisted-pair 802.3/Ethernets
- Single-ended SCSI-2 port
- Three Fast Wide Differential (FWD) SCSI-2 ports
Three CK-KFTIA-AA cabinet kits
256 MB, 512 MB, 2 GB or 4 GB of memory
BA660-AB StorageWorks Plug-in-unit (PIU)
2 GB or 4.3 GB 3.5” SCSI system disk drive
600 MB CD-ROM drive
DWZZB-VW SCSI signal converter
Three-Phase Power Subsystem with power cord
One H7263-AC or H7263-AD non-BBU capable
48 VDC power regulator
Shielded console cable is included for connection to
the console terminal
Factory Installed Software
5/300 Operating System Software
- DIGITAL UNIX base license,
DIGITAL NAS Base Server 200 software, or
- OpenVMS base license,
DIGITAL NAS Base Server 200 software
5/440 Operating System Software
- DIGITAL UNIX base license,
Unlimited User license, Server Extension license,
Internet Access Software license, or
- OpenVMS base license,
DIGITAL Enterprise Integration Package (EIP).
One year hardware product warranty
90 day software product warranty
System installation included with AlphaServer 8400
5/440 Base Servers
DIGITAL UNIXThree Phase2 GB
DIGITAL UNIXThree Phase4 GB
OpenVMSThree Phase2 GB
OpenVMSThree Phase4 GB
Note: xA = 60 Hz, 208 V, xB = 50 Hz, 380/416 V, xC = 50/60 Hz, 202 V Japan
All Three Phase power variations include attached power cord.
3.208 Alpha Servers
AlphaServer 8400
Step 1a—5/300 System Building Blocks
System Building Blocks are an alternative to standard Base Servers, or Expanded Base Servers. They provide flexibility in
configuring the AlphaServer 8400 with a choice of memory and I/O options.
System Building Block Requirements:
Minimum of one Memory module
Minimum of one I/O module
CD-ROM Drive
Systems require DIGITAL UNIX V3.2B or later, and OpenVMS V6.2 or later.
Console terminal required unless available on site.
System consists of 9 slot backplane—three slots used by CPU, memory, and system I/O modules.
- Six slots available for additional CPU, memory, or system I/O module(s).
If KFTHA-AA I/O module is selected the following PCI or XMI options must be ordered to provide the interface to
CD-ROM drive.
Required for PCI systems
DWLPB-AA
KZPAA-AA
PCI plug-in unit. See Step 5 for details.
PCI single-ended SCSI controller for CD-ROM connection only; KZPAA is restricted as CD-ROM
connection only, no other disk or tape connections are supported—maximum one per system.
BN21H-02
SCSI cable
Required for XMI systems
DWLMA-AA
KZMSA-AB
BN21H-02
CD-ROM, 600 MB 5.25” in cabinet drive (RRDCD-CA) is required and must be ordered separately.
If Factory Installed Software is required, BA660-AB, appropriate disk drive, and controller must be ordered separately.
Redundant power supply (N+1) can be added if required.
XMI plug-in unit. See Step 6 for details.
XMI single-ended SCSI controller
SCSI cable
AlphaServer 8400 5/300 System Building Blocks
Processor module with Two Alpha microprocessor
21164 5/300 MHz CPU(s), each CPU includes 4 MB
Backup cache
DIGITAL UNIXThree PhaseRequiredRequired
OpenVMSThree PhaseRequiredRequired
Note: xA = 60 Hz, 208 V, xB = 50 Hz, 380/416 V, xC = 50/60 Hz, 202 V Japan
All Three Phase power variations include attached power cord.
Alpha Servers 3.209
AlphaServer 8400
Step 1b—AlphaServer Expansion Packages
AlphaServer Expansion Packages are designed to be added to Base AlphaServers, Expanded Base Servers, and System
Building Blocks to create fully functional CI cluster add-on systems. They include all the necessary hardware (excluding
console terminal) and software to provide complete and operational systems.
Note: These packages are only orderable with a system configuration. They are not orderable as stand alone, upgrade
options or spared on the order.
OpenVMS AlphaServer Expansion Package
8YCAA-AX
Cluster Add-on Package includes:
DWLMA-AA XMI plug-in unit
CIXCD-AC XMI CI controller
One BNCIA 10-meter cable
OpenVMS cluster License (QL-MUZAQ-AA)
Step 2—Additional CPU Modules (SMP Upgrades)
5/300 MHz systems support a maximum of 6 processor
modules (total of 12 CPUs)
5/440 MHz systems support a maximum of 7 processor
modules (total of 14 CPUs) under UNIX V3.2G and
V4.0B or OpenVMS V6.2-1H3 and V7.1. Requires
console V4.8-6 or later firmware and DECevent V2.3
plus patch files included in the QZ-00RAA-T8 kit.
Combining 5/300, 5/350, or 5/440 MHz CPU modules in
same system is not supported.
For more than three processor modules in a system, a
minimum of two separate memory modules are
recommended for optimal system performance.
All SMP upgrades include processor module with Alpha
microprocessor(s) SMP license, and end-user product
warranty.
Maximum of 28 GB of memory supported on 5/300 MHz
CPUs Rev H07, H08, H09, P08, P09, P10, and all 5/350
and 5/440 MHz CPUs.
For Base Servers or Expanded Base Servers order up to
six additional memory modules—system maximum
seven.
System Building Blocks require the selection of one
memory module—system maximum seven.
Maximum of seven memory modules is reduced by one
for each additional CPU module added from Step 3 and
Memory modules
- 128 MB through 2 GB memory modules have built in
two-way interleaving; additional interleaving is
accomplished by adding more memory modules
- 4 GB memory modules have built in four-way
interleaving. Best performance is achieved when two
2 GB modules are paired with one 4 GB module. This
set (2 x 2 GB and 1 x 4 GB) can be paired with
another 8 GB memory set for a maximum of 16-way
memory interleaving.
each additional System I/O module added from Step 5.
PCI and XMI I/O expansion buses are available on AlphaServer 8400 systems. Application and system configuration
determines maximum I/O configuration. Configuration limits exist at I/O bus level and controller level. With different I/O
buses present in the system, verify maximum number of allowed controllers listed in the Controller Configuration Table.
Each DWLPB-AA/AB (PCI plug-in unit) includes a
12-slot PCI bus and uses one rear expansion bay. SCSI
disks in BA660-AB plug-in units can occupy the
corresponding front expansion bay.
Each DWLPB-AA/AB (PCI plug-in unit) has one open
space for addition of DWLPB-BA/BB (second PCI
expansion box) or BA661-AA (Wide SCSI StorageWorks
shelf)
DWLPB-AA
PCI plug-in unit with one PCI box for AlphaServer 8400 system cabinet only, maximum two per
system cabinet, two per system. Requires one I/O channel connection on either KFTIA-AA or
KFTHA-AA.
DWLPB-AB
PCI plug-in unit with one PCI box for AlphaServer 8400 expansion cabinet only, maximum two
per expansion cabinet, four per system. Maximum of six DWLPB-AA and DWLPB-AB (PCI plug-in
units) per system. Requires one I/O channel connection on either KFTIA-AA or KFTHA-AA.
DWLPB-BA
Second PCI expansion box for mounting in DWLPB-AA—maximum one per DWLPB-AA.
Requires one I/O channel connection on either KFTIA-AA or KFTHA-AA.
DWLPB-BB
Second PCI expansion box for mounting in DWLPB-AB—maximum one per DWLPB-AB.
Requires one I/O channel connection on either KFTIA-AA or KFTHA-AA.
BA661-AA
Wide SCSI StorageWorks Shelf (BA356-LB) can be added to DWLPB-AA/AB in place of second
PCI expansion box (DWLPB-BA/BB). Maximum one BA661-AA per DWLPB-AA/AB, and
maximum of six BA661-AA per system. Supports 16-bit (Wide) SCSI and some 8-bit (Narrow) SCSI
devices.
KFE70-AA
EISA Bridge option—PCI to EISA bridge module set—must reside in first DWLPB-AA in system
cabinet only. Converts PCI bus from 12-slot bus to 2 EISA, 6 PCI/EISA, and 2 PCI slots. Includes
RX26 floppy drive, mounting hardware, and cables to mount RX26 below CD-ROM in the system
cabinet. Maximum of one EISA Bridge option per system. This option is required to support KZPSC
SCSI RAID controllers. It includes the floppy disk drive required to run the RAID Configuration
Utility (RCU).
DWLMA-AA
XMI plug-in unit for system cabinet—maximum two per system. Requires one I/O channel
connection on either KFTIA-AA or KFTHA-AA.
DWLMA-BA
XMI plug-in unit for I/O expansion cabinet—maximum two per cabinet, four per system. Total
maximum six DWLMA-AA and DWLMA-BA (XMI plug-in units) per system. Requires one I/O
channel connection on either KFTIA-AA or KFTHA-AA.
Each DWLMA-AA/BA (XMI plug-in unit) includes one
12-slot XMI channel—uses two expansion bays, front
and back.
Each PCI and XMI plug-in unit requires one I/O channel
connection to either KFTHA-AA or KFTIA-AA, see Step
6.
Maximum of twelve I/O channels supported (three
KFTHAs).
Alpha Servers 3.211
AlphaServer 8400
Step 5—System I/O Modules
KFTIA-AA system I/O module included with Base Server; KFTHA-AA included with Expanded Base Server—any
combination of KFTIA or KFTHA modules can be added for a maximum of three.
- Maximum twelve I/O channels available on AlphaServer 8400.
System Building Block requires the selection of one I/O module.
KFTHA-AA
KFTIA-AA
BN26M-xx
BN21H-xx
CK-KFTIA-AA
BN21K-xx
BN21K-02*
BN21K-03*
BN21K-05/10
* Manufacturing may substitute correct cable length depending on configuration.
System I/O module with four I/O channels for PCI or XMI plug-in units
System I/O module with one I/O channel for PCI or XMI plug-in units. Includes
- two 802.3 twisted-pair Ethernet ports—requires BN26M cable per port
- single-ended SCSI-2 port—requires BN21H cable
- three FWD (Fast Wide Differential) SCSI-2 ports—requires CK-KFTIA-AA and
BN21K cable per port
One of the following optional FDDI daughter cards can be added to KFTIA-AA—see Step 8 for
cables.
- Single attachment station multi-mode fiber card (DEFPZ-AA) or
- Twisted-pair copper card (DEFPZ-UA)
Prestoserve (DJ-ML300-BA) can be added to KFTIA-AA
Ethernet twisted-pair cable; 8-pin MP to 8-pin MP, screened, EIA/TIA Category 5 cable.
SCSI-2 Single-ended cable; 50-pin male straight to 50-pin male straight. Connects KFTIA-AA
single-ended SCSI-2 port to StorageWorks shelf.
Cabinet kit for FWD (Fast Wide Differential) SCSI-2 port. One kit required for each used port on
KFTIA-AA, maximum three per KFTIA-AA. Cabinet kit includes Y-cable and FWD terminator.
SCSI-2 Fast Wide Differential cables; 68-pin male straight to 68-pin male right-angle. Connects
KFTIA-AA Fast Wide Differential SCSI-2 ports to DWZZA-VA or DWZZB-VW.
Connects from KFTIA FWD port to DWZZB-VW in BA660-AB System cabinet (rear)
Connects from KFTIA FWD port to DWZZB-VW in BA661-AA in DWLPB-xx PIU
Connects from KFTIA FWD port to DWZZB-VW in BA660-AB System cabinet (front)
Connects from KFTIA FWD port to DWZZB-VW in BA660-AB Expansion cabinet (front or rear)
Connects from KFTIA FWD port to DWZZB-VW in BA356-JB in SW500 and SW800 Cabinets
Step 6—Storage Controllers
KFTIA-AA included with each Base Server; KFTHA-AA
included with Expanded Base Server—PCI, EISA, and
XMI storage controllers can be added.
- Requires corresponding PCI plug-in unit (DWLPBAA/AB/BA/BB) or XMI plug-in unit (DWLMAAA/BA).
DWZZA-AA requires minimum revision E02 for
connecting any Fast Wide Differential SCSI-2 port from
KFTIA-AA or KZPSA-BB to TZ8xx tape loaders.
PCI-based Storage Controllers
KZPSA-BB
BN21K-xx
BN21K-01*
BN21K-02*
BN21K-05/10
PCI Fast Wide Differential SCSI Adapter—OpenVMS V6.2-1H3 supports eight per PCI,
maximum 26 per system. DIGITAL UNIX supports eight per PCI, maximum 32 per system (uses one
PCI slot). Provides one SCSI-2 bus. KZPSA supports DECsafe Available Server.
SCSI-2 Fast Wide Differential cables—68-pin male straight to 68-pin male right-angle. Connects
KZPSA-BB Fast Wide Differential SCSI-2 port to DWZZA-VA or DWZZB-VW.
Connects from KZPSA to DWZZB-VW in BA660-AB System cabinet (rear)
Connects from KZPSA to DWZZB-VW in BA661-AA in DWLPB-xx PIU
Connects from KZPSA to DWZZB-VW in BA660-AB System cabinet (front)
Connects from KZPSA to DWZZB-VW in BA660-AB Expansion cabinet (front or rear)
DWZZB-VW Fast Wide Differential Single-ended SCSI
Converter requires minimum revision A01 for connecting
FWD SCSI-2 signals from KFTIA-AA or KZPSA-BB to
BA356-JB StorageWorks Shelf.
System maximum of four KZPSC or KZPAC SCSI
RAID controllers.
Tape and optical devices are not supported on KZPSC or
KZPAC SCSI RAID controllers.
3.212 Alpha Servers
AlphaServer 8400
Step 6—Storage Controllers
(continued)
PCI-based Storage Controllers
KZPAC-AA
PCI one-port SCSI RAID Controller with 4 MB cache memory—Uses one PCI slot. Provides one
fast/wide single-ended connection. Allows RAID levels 0, 1 and 5. Includes RAID Array 230/plus
subsystem software and documentation kit. KFE70-AA EISA Bridge option required. Tape and
optical drives not supported. Maximum of 4 per PCI, maximum of 4 per system supported with
DIGITAL UNIX V3.2G or V4.0B; OpenVMS V6.2-1H3 or v7.1.
KZPAC-CA
PCI three-port SCSI RAID Controller with 4MB cache memory—Uses two PCI slots. Provides
three fast wide/single-ended connections. Allows RAID levels 0, 1 and 5. Includes RAID/Array
230/plus subsystem software and documentation kit. KFE70-AA EISA Bridge option required. Tape
and optical drives not supported. Maximum of four per PCI, maximum of four per system if third port
not used (otherwise maximum of three per PCI, three per system) supported with DIGITAL UNIX
V3.2G or V4.0B; OpenVMS V6.2-1H3 or V7.1. Order BN31K-0E or KZPAC-SB for third port
connection.
KZPAC-CB
PCI three-port SCSI RAID Controller with 8MB cache memory—Uses two PCI slots. Provides
three fast wide/single-ended connections. Allows RAID levels 0, 1 and 5. Includes RAID/Array
230/plus subsystem software and documentation kit. KFE70-AA EISA Bridge option required. Tape
and optical drives not supported. Maximum of four per PCI, maximum of four per system if third port
not used (otherwise maximum of three per PCI, three per system) supported with DIGITAL UNIX
V3.2G or V4.0B; OpenVMS V6.2-1H3 or V7.1. Order BN31K-0E or KZPAC-SB for third port
connection.
BN31S-1E
1.5 meter wide single-ended SCSI cable for connections from PCI RAID controller to BA660-AB
system cabinet (in front and rear locations) and BA661-AA. One required for each used port on
KZPSC-BA or KZPAC-CA/CB module.
BN31K-0E
Required for KZPSC-BA or KZPAC-CA/CB to use third port on module. Connects internally from
KZPSC-BA module to second PCI slot/bulkhead.
KZPAC-SB
SCSI cable/bulkhead assembly kit with two ports for KZPSC-BA or KZPAC-CA/CB, allows
connection of two third-port outputs using one PCI bulkhead slot.
BN31S-02
2.0 meter wide single-ended SCSI cable for connections from PCI RAID controller to BA660-AB
system cabinet and BA661-AA.
KZPSC-UB
MS100-BB
KZPSC-AA
Battery back-up for cache memory option for KZPAC or KZPSC controller.
8 MB cache memory option; upgrades KZPAC-CA to KZPAC-CB, field installable only.
PCI one-port SCSI RAID Controller—OpenVMS and DIGITAL UNIX support four per PCI,
maximum four per system (uses one PCI slot). KFE70-AA EISA Bridge option required. Provides one
fast/wide/single-ended connection. Allows RAID levels 0, 1, and 5. Tape drives are not supported.
KZPSC-BA
PCI SCSI RAID Controller with three ports—OpenVMS and DIGITAL UNIX support four per
PCI, maximum four per system (uses two PCI slots). KFE70-AA EISA Bridge option required.
Provides three Fast Wide/single-ended connections. Allows RAID levels 0,1, and 5. Tape drives not
supported. Order BN31K-0E or KZPAC-SB for third port connection.
BN31S-1E
1.5 meter wide single-ended SCSI cable for connections from PCI RAID controller to BA660-AB
system cabinet (in front and rear locations) and BA661-AA. One required for each used port on
KZPSC-BA or KZPAC-CA/CB module.
BN31K-0E
Required for KZPSC-BA or KZPAC-CA/CB to use third port on module. Connects internally from
KZPSC-BA or KZPAC-CA/CB module to second PCI slot/bulkhead.
KZPAC-SB
SCSI cable/bulkhead assembly kit with two ports for KZPSC-BA or KZPAC-CA/CB, allows
connection of two third-port outputs using one PCI bulkhead slot.
BN31S-02
2.0 meter wide single-ended SCSI cable for connections from PCI RAID controller to BA660-AB
system cabinet and BA661-AA.
KZPSC-UB
MS100-AA
MS100-AB
KFPSA-AA
†
†
Battery back-up for cache memory option for KZPAC or KZPSC controller.
16 MB Cache memory option for KZPSC-AA/BA, maximum one per controller, field installable only.
32 MB Cache memory option for KZPSC-AA/BA, maximum one per controller, field installable only.
PCI DSSI Adapter (OpenVMS only)—Requires OpenVMS V6.2-1H2 or later; minimum
System Console Firmware Revision 3.09. Maximum twelve per PCI, 24 per system with OpenVMS
V6.2-1H3. (End node only) Note: KFPSA and KFMSB not supported on the same bus.
BC21Q-xx
BC22Q-xx
† Requires AlphaServer 8400 minimum System Console Firmware Revision V3.2.2, OpenVMS V6.2-1H2 and DIGITAL UNIX V3.2D