Kessler-Ellis Products MS817 Installation And Operating Instructions Manual

MS817
http://www.kep.com
Signal Conditioner & Pulse Isolator
Installation and Operating Instructions
KESSLER-ELLIS PRODUCTS
990210 01/26/10
10 Industrial Way East
Eatontown, NJ 07724
800-631-2165 • 732-935-1320
INDEX
DESCRIPTION ................................................................................... 1
SPECIFICATIONS ............................................................................... 1
WIRING HOOKUP ............................................................................... 1
INPUT & OUTPUT SETTINGS ............................................................ 2
REMOVING THE CASE .......................................................... 2
OUTPUT ADJUSTMENTS ...................................................... 2
LED INDICATOR ...................................................................... 2
DIMENSIONS ..................................................................................... 3
WARRANTY ....................................................................................... 3
DECODING PART NUMBER ............................................................. 3
Raw Signal
Flowmeter
with Magnetic Pickup
MS817
Mag Pickup Input
1 2
7 9
10
8
+
Conditioned Pulse Output
Description:
1 2 3
4 5 6
7 8 9
10 11 12
Magnetic pickup
Magnetic pickup
Contact Closure Input
Common
Opto-isolator In (+)
Opto-isolator In (–)
(+) DC Power Input
DC Power Input Common
Pulse Output (+)
Common
Isolated Pulse Out (+)
Isolated Pulse Out (–)
+ –
mV
Input
3-30V
Input
3.3k7
10k7
10k7
LPF
Contact Closure
5 V
Regulator
Isolated Pulse
Output
Pulse
Output
DC
Input
1
2
5
6
3
4
7
8
9
10
11
12
+5V
+
+
+
+
The model MS817 is a signal conditioner which permits the user to condition and scale the input pulses from a pulse producing sensor into a high level output where each pulse represents an engineering unit of measure.
Several pulse input types are supported including magnetic pickup, contact closure, and an isolated pulse input.
The pulse output is a nominal square signal.
The pulse output is available in isolated and non-isolated versions. User selections include output pulse and internal pullup resistors.
The user may select his pulse output conguration by means of
a dip switch.
The unit is powered to 8 - 35 VDC. Reverse polarity protection is provided. A power indicator is provided.
The unit is available in enclosures intended for either DIN rail, NEMA4X or Explosion Proof.
Simplied Block Diagram
Specications:
Pulse Input:
Isolated Pulse: Logic 1 (high): 3 - 30 VDC Logic 0 (low): 0 - 1 VDC Input Frequency Range: 0-10000 Hz
Input Impedance: 3.3 k Ω
Reverse Polarity Protection Isolation Voltage: 500 V Contact Closure: Switch Debounce: 40 CPS maximum count rate 10000 ohm internal pullup to 5 VDC Magnetic Pickup: Sensitivity: 30 mV p-p Bandwidth: 0-3500 Hz Over Voltage Protection to 30 VDC 10 Kohm input resistance
Pulse Output:
Pulse Duration: Nominal 50/50 duty cycle Open Collector Pulse: Maximum Voltage: 48 VDC Maximum Current: 100 mA @ .1.5 VDC (typ.) Max. Output Speed: 10 kHz Reverse Polarity Protection Overcurrent Protection Jumper selectable for 5 V and 24 V pulse output Isolated Pulse: Maximum Voltage: 30 VDC Maximum Current: 10 mA Max. Output Speed: 1 kHz Isolation Voltage: 500 VDC Reverse Polarity Protected
Typical Application:
Power Input:
Input Voltage Range: 8.5 to 35 VDC Supply Current: 25 mA (nominal) Reverse Polarity Protection Transient Protection
Pulse Scaling: NONE - Output is a conditioned version of the pulse input
Mounting Styles
DIN Rail Mount: Plastic enclosure with a snap fastener for
tting to DIN 46 277 and DIN EN 50 022
assembly rails.
NEMA 4X: 4.92” x 4.92” NEMA 4X Enclosure for wall
mounting.
Explosion Proof: Aluminum enclosure for: Class I, Division 1, Groups B, C & D Class II, Division I, Groups E, F & G.
Listing: CE Compliant
Wiring:
INPUT & OUTPUT SETTING
1 2 3 4
ON
10 1 1 12
1 2 3
4 5 6
7 8 9
Power LED
REMOVING THE CASE:
The case must be removed to change switch settings. To remove the case proceed as follows:
Refer to FIGURE 1. Using nger tips, carefully pry the case away from the terminal blocks (as shown with dotted
lines).
Pry far enough to release the restraining clips on both sides of the case.
Press up on terminal block with thumbs. The assembly will pop out allowing it to be removed from case.
FIGURE 1 FIGURE 2
POWER LED INDICATOR:
The MS817 has a power LED to indicate the power status of the unit. The table below describes the various states for the LED.
POWER LED MEANING
OFF The unit is off. ON (constant) The unit is loop powered.
DIP Switch for Selecting Pull-Up Resistors
INTERNAL PULLUP RESISTOR VOLTAGE
(for pulse output)
Internal pullup resistors are congurable with dip switch settings. Refer to the following tables to congure the unit
for your application:
S3 S4 Pulse Output Voltage
ON OFF 5 VDC OFF ON 24 VDC OFF OFF Open Collector
Dimensions
3.88 (98.5)
2.95 (75)
1.40 (35.5)
.89
(22.5)
4.92
(125)
4.92
(125)
4.21
(107)
4.21
(107)
Mounting holes molded directly under cover screws. Max. screw head .29" (Typ. 4 places)
TOP VIEW
PANEL INSTALLED
To access terminals, remove cover and 4 panel screws.
2.95 (75)
1.93 (49)
.18 (5)
.43
(11)
SIDE VIEW
Optional holes or hub fitting
4.75 -5
(121 - 127)
4.9 - 5.25 (124 - 133)
5.9 - 7.7
(150 - 196)
3/4” NPT (2) HLS. (feed thru hubs)
All Dimension in inches (mm)
Optional 3rd Conduit Entry
DIN Rail Mount
NEMA4X
WARRANTY
This product is warranted against defects in materials and workmanship for a period of two (2) years from the date of shipment to Buyer. The Warranty is limited to repair or replacement of the defective unit at the option of the manufacturer. This warranty is void if the product has been altered, misused, dismantled, or otherwise abused. ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, ARE EXCLUDED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
Explosion Proof Enclosure
Kessler - Ellis Products Co.
10 Industrial Way East
Eatontown, NJ 07724
(732) 935 - 1320
Toll Free 800 - 631 - 2165
Fax (732) - 935 - 9344
Ordering Information
Example MS817 1 B ET
Series
Output Type
1 = Open Collector & Isolated Pulse (STD)
Mounting:
B= Nema 4X C= Explosion Proof D= DIN Rail
Options:
ET= Extended Temp: -4° to 185°F (-20° to 85° C) T = Third 3/4” conduit entry for Explosion Proof Housing H2 = 0.875” Hole for NEMA4 mounting style
HF2 = 0.5” Female NPT Hub tting
H3 = 1.125” Hole for NEMA4 mounting style
HF3 = 0.75” Female NPT Hub tting
Accessories: (add to end of part number) DR-4= 4” DIN Rail