Operating instructions Electronic display counter 521K, 522, 523 and 524
1.1 Safety instructions and warnings
Only use this display
– in a way according to its intended
instructions and the general
safety instructions.
1.2 General safety instructions
1. Before carrying out any installation or mainte­nance work, make sure that the power supply of the digital display is switched off.
2. Only use this digital display in a way according to its intended purpose: If its technical condition is perfect. Adhering to the operating instructions and the general safety instructions.
3. Adhere to country or user specific regulations.
4. The digital display is not intended for use in areas with risks of explosion and in the branches excluded by the standard EN 61010 Part 1.
5. The digital display shall only operated if it has been correctly mounted in a panel, in accor­dance with the chapter “Technical features”.
1.3 Use according to the intended purpose
The digital display may be used only as a panel­mounted device. Applications of this product may be found in industrial processes and controls, in manufacturing lines for the metal, wood, plastics, paper, glass, textile and other processing indus­tries. Over-voltages at the terminals of the digital dis­play must be kept within the limits in Category II
If the digital display is used to monitor machines or processes in which, in case of a failure of the device or an error made by the operator, there might be risks of damaging the machine or caus­ing accidents to the operators, it is your responsi­bility to take appropriate safety measures.
1.4 Description
521K
Please note: Read first chapter 2 of 524K and go on on page 2.
522K
Please note: Read first chapter 2 of 524K and go on on page 4.
523K
Please note: Read first chapter 2 of 524K and go on on page 6.
524K
524K is a multipurpose device. Depending on
the programmed basic function, the device oper­ates like
• the pulse counter
521K (see page2) or
• the frequency meter
522K (see page 4) or
• the time meter
523K (see page 6)
2. Setting of the operating parameters
a. Press both front side keys keys and switch on
the supply voltage or, if the supply voltage is already on, press both keys simultaneously during 5 s.
b. The display shows
c. After releasing the keys, the display shows
c1.Hold the left key pressed and press the right
key to leave the programming operation.
!
Kessler-Ellis Products
10 Industrial Way East, Eatontown, NJ 07724
990093 08/08/06
22
c2.Press the right key to switch to
.
d. Hold the left key pressed and press the right
key to switch to the first parameter.
e. After releasing the keys, the display alternates
between the menu title and the current menu item setting. After pressing any key, only the menu item setting is displayed.
f. Pressing the right key, the menu item setting
will be switched to the next value. If figures are to be input (e.g. when setting the scaling factor), select first the decade using the left key, and then set the value using the right key.
g. Hold the left key pressed and press the right
key to switch to the next menu item.
h. The last menu title ”EndPro” allows, when
selecting “Yes”, to exit the programming menu and to take over (store) the new values. If “no” is selected, the programming routine is repeated, the latest values set remaining active. They can now be checked again or modified.
3. Programming routine
The first menu item is the selection of the basic operating mode, which determines the functions of the device.
Operating mode pulse counter. Continued in point
4. of
521K on page 2
Operating mode frequency meter. Continued in point 4. of
522K on page 4
Operating mode time meter. Continued in point 4. of 523K on page 6
Pulse counter/Position indicator
521K
(524K: Operating mode pulse counter)
1. Description
6-digit display counter with SET/RESET-function
• Red LED display, character height 8 mm
• Display range from -19 999 to 999 999
• Leading zeros suppression
• Programming via two setting keys on the front side
• During programming, the display guides the user with text prompts
• Counter operating modes:
Count input INP A + count direction input INP B (Cnt.Dir) Differential count INP A – INP B (up.dn) Totalizing INP A + INP B (up.up) Count Up/Down INP A 90° INP B x 1 (quAd) Count Up/Down INP A 90° INP B x 2 (quAd 2) Count Up/Down INP A 90° INP B x 4 (quAd 4)
• Optional optocoupler output
2. Inputs
INP A
Dynamic count input.
INP B
Dynamic count input.
SET/RESET
Dynamic SET/RESET input. Linked in parallel to the red SET/RESET key. Resets the counter to the predefined setting value.
3. Optocoupler output (optional)
Active if count value < 0. Simple preset counter can be realized, when using subtract mode.
4. Programming routine
The programmable parameters of the device are described below, in the order in which they can be set. The device is fully programmed after one pass of the routine.
The first values stated correspond to the factory
settings
33
4.1 Polarity of the inputs
npn: switching for 0 V
pnp: switching for +U
B
4.2 Switching on the 30 Hz filter (INP A, INP B)
30 Hz filter off (f
max
)
30 Hzfilter on
Count input and count direction input INP A: Count input INP B: Count direction input
Differential input IINP A: count input adding INP B: count input subtract-
ing
Totalizing INP A: count input adding INP B: count input adding
Quadrature input INP A: count input 0° INP B: count input 90°
Quadrature input with pulse doubling INP A: count input 0° INP B: count input 90° Each pulse edge of INP A will be counted
Quadrature input with pulse quadrupling INP A: count input 0° INP B: count input 90° Each pulse edge of INP A and INP B will be counted.
4.3 Input mode
4.4 Multiplying factor
It can be set from 00.0001 up to 99.9999. The decimal point is set to 4 decimal places. „0“ is not accepted!
4.7 SET/RESET Mode
manual reset via the red SET/RESET key and electrical reset via the SET/RESET input
no reset (red SET/RESET key and SET/RESET input locked)
only electrical reset via the SET/RESET input
only manual reset via the red SET/RESET key
4.6 Decimal point
The decimal point defines the way of displaying the count values. It does not affect counting.
0 no decimal place
0.0 one decimal place
0.00 two decimal places
0.000
three decimal places
It can be set from 00.0001 up to 99.9999. The decimal point is set to 4 decimal places. „0“ is not accepted!
4.5 Dividing factor
The filter provides input damping*
* where bounce occurs, e.g. with contacts
44
4.9 End of programming
The programming routine is repeated once more. The values set until now can be checked and mod­ified.
The programming routine wil be left and all values set will be stored as new parameters. Afterwards the device is ready for operation.
4.8 SET value
The device will be set to the set point by pressing the red SET/RESET key or activating the SET/RESET input. SET value -199999... 999999 (number of deci­mal places depends on the decimal point option)
Tachometer/Frequency meter
522K
(524K: Operating mode frequency meter)
1. Description
• 6 digit frequency meter
• Red LED display, character height 8 mm
• Display range from 0 to 999 999
• Leading zeros suppression.
• Programming via two setting keys on the front side
• During programming, the display guides the user with text prompts
• Value conversion and display in 1/s or 1/min
• Optional optocoupler output
2. Inputs
INP A
Dynamic count input.
3. Optocoupler output (optional)
Active at f=0. Can be used e.g. to activate a „No operation“ lamp.
4. Programming routine
The programmable parameters of the device are described below, in the order in which they can be set. The device is fully programmed after one pass of the routine.
The first values stated correspond to the factory
settings
4.1 Polarity of the inputs
npn: switching for 0 V
pnp: switching for +U
B
For programming the decimal point see 4.6
55
4.3 Multitplying factor
It can be set from 00.0001 up to 99.9999. The decimal point is set to 4 decimal places. „0“ is not accepted!
4.5 Decimal point
The decimal point defines the resolution in the selected measuring range 1/min or 1/sec
0 no decimal place
0.0 one decimal place
0.00 two decimal places
0.000
three decimal places
4.2 Switching on the 30 Hz filter
30 Hz filter off (f
max
)
30 Hzfilter on
It can be set from 00.0001 up to 99.9999. The decimal point is set to 4 decimal places. „0“ is not accepted!
4.4 Dividing factor
4.6 Display mode
Value conversion and display in 1/s
Value conversion and display in 1/min
4.7 Max. time to wait until „0“ is displayed
This parameter indicates, how long it takes, when measuring is active, until „0“ is displayed.
Max. time to wait 00.1 s (min. value)
Max. time to wait 99.9 s
4.8 End of programming
The programming routine is repeated once more. The values set until now can be checked and mod­ified.
The programming routine wil be left and all values set will be stored as new parameters. Afterwards the device is ready for operation.
The filter provides input damping*
* where bounce occurs, e.g. with contacts
66
Start/Stop via Inp B. counting while Inp B (Gate) not active or open
Start/Stop via Inp B. counting while Inp B (Gate) active (High level with pnp; Low level with npn)
Count
Start/Stop via
INP B (LOW-HIGH edge with pnp; HIGH-LOW edge with npn). Every active edge changes the counter status.
Count start via INP A, stop via INP B. (LOW­HIGH edge with pnp; HIGH-LOW edge with npn)
4.3 Input mode
4.1 Polarity of the inputs
4.2 Switching on the 30 Hz filter (INP A, INP B)
30 Hz filter off Start/Stop inputs not damped
30 Hz filter on Start/Stop inputs damped for use with mechanical switches.
Time meter 523K
(524K: Operating mode time meter)
1. Description
• 6 digit time meter with SET/RESET function
• Red LED display, character height 8 mm
• Display range from 0 to 999 999
• Leading zeros suppression.
• Operation indicator: the decimal point of the lowest digit blinks while the count is active.
• Programming via two setting keys on the front side
• During programming, the display guides the user with text prompts
• Time meter operating modes – Counting while INP B is inactive (GAtE.Lo) – Counting while INP B is active (GatE.hi) – Count Start/Stop with INP B edge (Inb.Inb) – Count Start with INP A edge, count Stop with
INP B edge (InA.Inb)
• Counting ranges h; min; s; h.min.s
• Optional optocoupler output
2. Inputs
INP A
Start input (depending on the input mode chosen)
INP B
Start/Stop or gate input (depending on the input mode chosen)
SET/RESET input
Dynamic SET/RESET input. Linked in parallel to the red RESET key. Resets the counter to the predefined setting value.
3. Optocoupler output (optional)
On active counting the output alternates at a fre­quency of 1 Hz between active and inactive.
4. Programming routine
The programmable parameters of the device are described below, in the order in which they can be set. The device is fully programmed after one pass of the routine.
The first values stated correspond to the factory
settings
77
Time unit: seconds (accu­racy depending on posi­tion of the decimal point*)
Time unit: minutes (accu­racy depending on posi­tion of the decimal point*)
Time unit: hours (accura­cy depending on position of the decimal point*)
Time units: Hours:Minutes:Seconds (decimal point setting is ignored)
4.4 Operating mode
*0, 0.1, 0.01, 0.001 means: time measurement in 0, 0.1, 0.01, 0.001 time units
4.5 Decimal point
The decimal point defines the resolution of the pro­grammed time unit.
0 1
0.0 1/10 (0,1)
0.00 1/100 (0,01)
0.000 1/1000 (0,001)
4.6 SET/RESET mode
manual reset via the red SET/RESET key and electrical reset via the SET/RESET input
no reset (red SET/RESET key and SET/RESET input locked)
only electrical reset via the SET/RESET input
only manual reset via the red SET/RESET key
4.8 End of programming
The programming routine is repeated once more. The values set until now can be checked and mod­ified.
The programming routine wil be left and all values set will be stored as new parameters. Afterwards the device is ready for operation.
4.8 SET value
The device will be set to the set point by pressing the red SET/RESET key or activating the SET/RESET input. SET value 0 ...999 999 or
99.59.59 (number of deci­mal places depends on the decimal point option)
5. Technical data
Supply voltage
DC power supply: 10 ... 30 V DC/max. 40 mA
with inverse-polarity protection
Display: 6 digits, red 7 segment
LED display, height 8 mm
Data retention: EEPROM
Polarity of the inputs:
Programmable, npn or pnp for all inputs
Input resistance:
appr. 5 kOhm
Count frequency 521K:
Power supply DC:
24 V 12 V 10 ...30 V Input level: Standard 5V typ. Low Level: 2,5 V 2,0 V 1,0 V typ. High Level: 22,0 V 10 V 4,0 V
Fmax*: kHz kHz kHz
CntDir 60 20 8 UpDown 25 15 8 Up.Up 25 15 8 Quad1 25 15 8 Quad2 25 15 8 Quad4 15 15
Count frequency 522K:
Frequency measurement
Accuracy <0.1 % Measuring principle:
< 38 Hz: period measurement > 38 Hz: gating time measurement
gating time 26,3 ms
Power supply DC: 24 V 12 V 10 ...30 V Input level: Standard 5V typ. Low Level: 2,5 V 2,0 V 1,0 V typ. High Level: 22,0 V 10 V 4,0 V
Fmax*: kHz kHz kHz
Tacho 60 20 8
Counting ranges 523K:
Seconds 0.001 s ... 999 999 s Minutes 0.001min ... 999 999 min Hours 0.001 h ... 999 999 h h.min.s 00 h 00 min 01 s
... 99 h 59 min 59 s
Accuracy <50 ppm
Minimum pulse length for the Reset input:
5 ms
Input sensitivity: Standard sensitivity:
Low: 0 ... 0,2 x UB [V DC]
High: 0,6 x UB ... 30 V DC 5 V sensitivity: Low: 0 ... 2 V DC
High: 4 ... 30 V DC
Pulse shape: any*, Schmitt-Trigger inputs
Optocoupler output (optional):
NPN optocoupler with open collector and open emitter; max. switching performance: 30 V DC/10 mA
* at maximum frequency square wave pulses 1:1
Ambient temperature:
–20 ...+65 °C
Storage temperature:
–25 ... +70 °C
EMC:
In compliance with the EC Directive 2004/108/EEC Noise emission EN 61 000-6-3
EN 55 011 Class B
Noise immunity EN 61 000-6-2
Housing:
For front panel mounting: 48 x 24 mm acc. to DIN 43700, RAL7021, dark grey
Weight: appr. 50 g
Protection: IP 65 (front)
Cleaning:
The front of the units is to be cleaned only with a soft wet (water !) cloth.
6. Terminal assignment
without optocoupler 1 10 ... 30 V DC 2 0 V GND 3 INP A 4 INP B (522K: n.c.) 5 SET/RESET (522K: n.c.)
with optocoupler 1 10 ... 30 V DC 2 0 V GND 3 INP A 4 INP B (522K: n.c.)
5 SET/RESET (522K, n.c.) 6 Emitter 7 Collector
7. Delivery includes:
1 Digital display
1Panel mounting clip
1 Bezel for screw mounting,
panel cut out 50 x 25 mm
1 Bezel for clip mounting,
panel cut out 50 x 25 mm
1 Seal
1 Operating instructions
99
8. Dimensions:
Panel cut-out:
22.2+0,3 x 45+0,6 mm
Front bezel
Counter sinking Af3, DIN 74