DUST/DEBRIS DISPOSAL
This vacuum cleaner contains dust hazardous to health. Emptying and maintenance operations, including removal
and renewal of dust collection bag, must only be carried out by authorised personnel wearing suitable personal
protection. Do not operate without the full filtration system fitted.
Disconnect the hose, fit the blanking cap on the hose entry, unlatch the clips and remove the motor head/HEPA
unit. Take care not to drop the motor head/HEPA unit. Remove the filter assembly and carefully release the
disposable bag from the bag tube and lift out of the canister. Seal the disposable bag inlet using the integral cap
on the bag collar. The disposable bag should be immediately placed in a suitably labelled impervious plastic
bag and this bag sealed and disposed of in accordance with the current regulations. Fit new disposable bag over
the bag tube inside the canister.
This vacuum cleaner is supplied with 5 spare Microfibre bags and a spare filter assembly. This (clean) spare filter
should be used and the motor head/HEPA unit refitted.
The contaminated filter should now be cleaned by using this vacuum cleaner and stored in a labelled plastic bag
ready for future use.
DECONTAMINATION
Decontamination operations should only be carried out by competent authorised personnel equipped with
suitable personal protection.
Before removing the accessories/vacuum cleaner from the contaminated area:
• AccessoriesshouldbecleanedexternallywithaTypeHvacuumcleaner.
• Theyshouldthenbecleanedwithanadhesivewipe,sealedateachendandsealedinaclearimperviousbag.
The bag should carry an appropriate warning label.
• Theexternalsurfacesofthebagshouldthenbecleanedwithanadhesivewipe.
• Thevacuumcleanershouldbecleanedexternallywithitself.Thedisposablebaganditscontentsshouldbe
removed and disposed of in accordance with the method described in the section titled Dust/Debris Disposal.
• Thevacuumcleanershouldthenbecleanedexternallywithanadhesivewipe.
• Thevacuumcleanershouldbesealedinaclearimperviousbag.Thebagshouldcarryanappropriatewarning
label.
• Theexternalsurfacesofthebagshouldthenbecleanedwithanadhesivewipe.
MAINTENANCE
Maintenance should be conducted by authorised agents only.
Maintenance must be carried out in a suitable controlled area with local filtered exhaust ventilation and facilities
for cleaning the area after servicing.
During maintenance always disconnect from the electrical supply.
Maintenance and cleaning must only be carried out by competent authorised personnel equipped with suitable
personal protection. All parts must be regarded as contaminated. Another Type H vacuum cleaner should be used
and each component to be removed, cleaned prior to removal.
DOP testing should be conducted every six months or whenever the equipment suffers a serious impact or damage.
Items that cannot be satisfactorily cleaned are to be disposed of in impervious plastic bags in accordance with
current regulations. All surfaces should be cleaned as they become exposed.
THERMAL CUTOUT SWITCH
This vacuum cleaner is fitted with a thermal switch which automatically stops the motor if it overheats. This
may be caused by a blocked hose or wands, a full Microfibre bag, or a blocked filter. If your vacuum cleaner cuts
out check for the above. The thermal switch will automatically reset itself when the motor temperature drops.
FILTRATION SYSTEM
This is a Type H Vacuum Cleaner. It is fitted with 3 stages of filtration on the negative pressure side of the motor
(that is before the motor, so that the motor always receives clean filtered air).
1st Stage - K4 Disposable Microfibre Bag
2nd Stage - High Efficiency Filter Assembly specially for Type H cartridges
3rd Stage - Type H HEPA (High Efficiency Particulate Air) Cartridge Filter
Also known as the Absolute or Essential Filter.
KV20–50H HEPA Filter part no. K27.03.04.
Note: The HEPA cartridge filter fitted to Kerstar KV20–50 Type H models has a very large
surface area compared to other models available and will therefore give improved performance
and a greatly increased filter life.
Access to the Microfibre Bag and Filtration System
a) To remove the motor head and HEPA cartridge unit, unclip the LOWER set of clips. Ensure that the clips
are hinged clear of the rim of the HEPA unit. Lift the motor head and HEPA unit clear of the canister.
b) To refit the motor head and HEPA unit align the head so that the cable entry lies directly opposite the hose
entry on the canister. Locate the clips over the rim of the HEPA unit and firmly press down both clips until
they have locked into position.
Note: The upper set of clips between the HEPA unit and motor head
have a lock-down device to prevent the separation of the motor head from the HEPA unit.
Only authorised and trained personnel should separate the motor head from the HEPA unit.
WARNING
This vacuum cleaner may contain dust hazardous to health. Emptying and maintenance operations including
removal and renewal of dust collection bag shall only be carried out by authorised personnel wearing suitable
approved personal protection.
WARNING
Do not use this vacuum cleaner unless the full filtration system is fitted – Type H cartridge, High Efficiency filter
assembly and Microfibre bag. Failure to fit the complete system may cause premature clogging of the Type H
cartridge and may also endanger health.
WARNING
Do not use this vacuum cleaner for the collection of explosive dusts.
Do not use this vacuum cleaner in a corrosive or flammable environment.
IMPORTANT
This vacuum cleaner is designed to collect hazardous dusts. Therefore any dust found within the machine or on
its filters may be dangerous to your health. Always take precautions.