KERN YKV-01, YKV-02 Operating And Installation Instructions

KERN & Sohn GmbH
Ziegelei 1
E-Mail: info@kern-sohn.com
Internet: www.kern-sohn.com
Operating and Installation Digital weighing transmitter
KERN YKV-01/02
Version 1.1
2019-04
Instructions
GB
D-72336 Balingen
Fax: +49-[0]7433-9933-149
YKV-01-02-BA_IA-e-1911
KERN YKV
Digital weighing transmitter
GB
Version 1.1 2019-04
Operating and installa t ion instructions
Contents
1 Technical data ................................................................................................ 4
2 Declaration of conformity ............................................................................. 5
3 Appliance overview ....................................................................................... 6
4 Basic Information (Gen eral) .......................................................................... 7
4.1 Proper use .................................................................................................................................. 7
4.2 Improper Use .............................................................................................................................. 7
4.3 Warranty ..................................................................................................................................... 7
4.4 Monitoring of Test Resources .................................................................................................... 8
5 Basic Safety Precaut io ns .............................................................................. 8
5.1 Pay attention to the instructions in the Operation Manual.......................................................... 8
5.2 Personnel training ....................................................................................................................... 8
6 Transport and storage ................................................................................... 8
6.1 Testing upon acceptance ........................................................................................................... 8
6.2 Packaging / return transport ....................................................................................................... 8
7 Unpacking and placing .................................................................................. 9
7.1 Installation Site, Location of Use ................................................................................................ 9
7.2 Unpacking and checking ............................................................................................................ 9
7.3 Transport Securing ..................................................................................................................... 9
7.4 Installation Weighing transmitter - Platform.............................................................................. 10
7.4.1 Weighing system design........................................................................................................... 10
7.4.2 How to connect the platform ..................................................................................................... 11
7.5 Connect weighing transmitter to PC ......................................................................................... 12
8 Configuration ............................................................................................... 13
9 Adjustment ................................................................................................... 14
10 Linearization / firs t adjustm ent ................................................................... 15
10.1 Carrying out the linearization .................................................................................................... 16
10.2 Performance of a single point adjustment ................................................................................ 17
11 Configuration using the KERN Balance Connectio n software ................ 18
12 Connection to your system ......................................................................... 20
12.1 USB .......................................................................................................................................... 20
12.2 Bluetooth .................................................................................................................................. 20
12.3 RS232 ....................................................................................................................................... 21
12.4 Ethernet .................................................................................................................................... 22
12.5 WLAN ....................................................................................................................................... 22
13 Carrying out measurements ....................................................................... 24
2 YKV-01-02-BA_IA-e-1911
13.1 Using your own software .......................................................................................................... 24
13.1.1 Request weighing data ......................................................................................................... 24
13.1.2 Zeroing and taring ................................................................................................................ 24
13.2 Using the BalanceConnection software ................................................................................... 24
13.2.1 Functions .............................................................................................................................. 27
YKV-01-02-BA_IA-e-1911 3

1 Technical data

KERN (type) TYKV-01-A TYKV-02-A
Model YKV-01 YKV-02 Net weight (kg) 1.1 1.1 Dimensions of the
housing (B x D x H) mm Permissible
ambient condition Housing material Synthetic material Humidity of air 80 % relative (not condensing) Input voltage Mains
adapter Input tension
Device Interfaces USB-Host/Master
100 x 127 x 28 mm 100 x 127 x 28 mm
- 10° C to +40° C
100 V - 240 V, 50 / 60 Hz
5 V, 500 mA
USB-Host/Master
(Standard)
WLAN/WiFi-Module
(factory option)
RS 232 (standard) RS 232 (standard)
Bluetooth 4.0
(factory option)
(Standard)
WLAN/WiFi-Module
(factory option)
Bluetooth 4.0
(factory option)
- Ethernet (Standard)
4 YKV-01-02-BA_IA-e-1911

2 Declaration of conform ity

The current EC/EU Conformity declaration can be found online in:
www.kern-sohn.com/ce
YKV-01-02-BA_IA-e-1911 5

3 Appliance overview

Example YKV-02-A:
Pos. Description
1 USB 2.0 type B 2 RS232 3 Ethernet 4 Connection to the load cell
6 YKV-01-02-BA_IA-e-1911

4 Basic Information (General)

4.1 Proper use

The digital weighing transmitter acquired by you is used in combination with a platform and serves to determine the weighing value of material to be weighed. It is intended to be used as a "non-automatic weighing system", i.e. the material to be weighed is manually and carefully placed in the centre of the weighing plate. As soon as a stable weighing value is reached the weighing value can be read.

4.2 Impro per Us e

Do not use weighing system (YKV and platform) for dynamic weighing. In the event that small quantities are removed or added to the material to be weighed, incorrect weighing results can be displayed due to the "stability compensation" in the device. (Example: Slowly draining fluids from a container on the balance.) Do not leave permanent load on the weighing pan. This may damage the measuring system. Impacts and overloading exceeding the stated maximum load (max) of the weighing plate, minus a possibly existing tare load, must be strictly avoided. The weighing system could be damaged. Never operate the weighing system in explosive environment. The serial version is not explosion protected. Changes to the weighing system's design are not permitted. This may lead to incorrect weighing results, safety-related faults and destruction of the weighing system. The weighing system may only be operated in accordance with the described default settings. Other areas of use must be released by KERN in writing.

4.3 Warranty

Warranty claims shall be voi ded i n cas e
Our conditions in the operation manual are ignored
The appliance is used outside the described uses
The appliance is modified or opened
Mechanical damage or damage by media, liquids, natural wear and tear
The appliance is improperly set up or incorrectly electrically connected
The measuring system is overloaded
YKV-01-02-BA_IA-e-1911 7

4.4 Monitoring of Test Resources

In the framework of quality assurance the measuring-related properties of the weighing system and, if applicable, the testing weight, must be checked regularly. The responsible user must define a suitable interval as well as type and scope of this test. Information is available on KERN’s home page (www.kern-sohn.com with regard to the monitoring of display units’ test substances and the test weights required for this. In KERN’s accredited DKD calibration laboratory test weights and digital weighing platforms may be calibrated (return to the national standard) fast and at moderate cost.

5 Basic Safety Precautions

5.1 Pay attention to the instructions in the Operation Manual

Carefully read this operation manual before setup and
commissioning, even if you are already familiar with KERN balances.

5.2 Pers onnel training

The appliance may only be operated and maintained by trained personnel.

6 T ransport and storage

6.1 Testing upon acceptance

When receiving the appliance, please check packaging immediately, and the appliance itself when unpa c kin g for po s sible visible damage.

6.2 Packaging / return t ransp ort

Keep all parts of the original packaging for a possibly
required return.
Only use original packaging for returning. Prior to dispatch disconnect all cables and remove
loose/mobile parts.
8 YKV-01-02-BA_IA-e-1911
Weighing transmitter
in the downloads area on http://www.kern-sohn.com

7 Unpacking and placing

7.1 Installation Site, Location of Use

The weighing system is designed to achieve reliable weighing results under normal conditions of use. You will work accurately and fast, if you select the right location for your weighing system.
On the installation site observe the following:
Place the weighing system on a firm, le vel sur fa ce;
Avoid extreme heat as well as temperature fluctuation caused by installing
next to a radiator or in the direct sunlight;
Protect the weighing system against direct draughts due to open windows and doors;
Avoid jarring during weighing;
Protect the weighing system against high air humi dit y, vapours and dust;
Do not expose the weighing system to extreme dampness for longer periods
of time. Non-permitted condensation (condensation of air humidity on the appliance) may occur if a cold appliance is taken to a considerably warmer environment. In this case, acclimatize the disconnected appliance for ca. 2 hours at room temperature.
Avoid static charge of weighed items or wei ghing c ontainer.
Major display deviations (incorrect weighing results) may be experienced, should electromagnetic fields (e.g. due to mobile phones or radio equipment), static electricity accumulations or instable power supply occur. Change location or remove source of interference.

7.2 Unpacking and checking

Take the weighing transmitter out of the packaging, remove the packaging material and install at the designated workstation. Check if that there has been no damage and that all packing items are present.
Scope of delivery / serial accessories:
Net adapter EU/UK/US
USB A to USB B cable
These installation instructions
Software KERN BalanceConnection

7.3 Transport Securing

Please note: if the YKV is used together with platform with transportation lock, this transportation lock must be released prior to use.
YKV-01-02-BA_IA-e-1911 9
Loading...
+ 18 hidden pages