KERN UFB, UFN Operating Instructions Manual

KERN & Sohn GmbH
Ziegelei 1 D-72336 Balingen email: info@kern-sohn.com
Phone: +49-[0]7433- 9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com
Operating Instructions Pallet scales
KERN UFB/UFN
Version 1.1 02/2010 GB
UFB/UFN-BA-e-1011
GB
KERN UFB/UFN
Version 1.1 02/2010
Operating Instructions Pallet scales
Table of Contents
1 Technical Data ................................................................................................... 4
2 Appliance overview display device.................................................................. 6
2.1 Keyboard overview .......................................................................................................7
2.1.1 Numeric input via navigation keys ..................................................................................... 8
2.2 Overview of displays.....................................................................................................8
3 Basic Information (General) ............................................................................. 9
3.1 Proper use ....................................................................................................................9
3.2 Improper Use................................................................................................................9
3.3 Warranty .......................................................................................................................9
3.4 Monitoring of Test Resources.......................................................................................9
4 Basic Safety Precautions................................................................................ 10
4.1 Pay attention to the instructions in the Operation Manual ..........................................10
4.2 Personnel training.......................................................................................................10
5 Transportation & Storage ............................................................................... 10
5.1 Testing upon acceptance ...........................................................................................10
5.2 Packaging / return transport .......................................................................................10
6 Unpacking and implantation .......................................................................... 10
6.1 Installation Site, Location of Use ................................................................................10
6.2 Unpacking...................................................................................................................11
6.3 Scope of delivery / serial accessories: .......................................................................11
6.4 Placing........................................................................................................................11
6.5 Mains connection........................................................................................................12
6.6 Storage battery operation (optional) ...........................................................................12
6.7 Adjustment..................................................................................................................13
6.8 Verification..................................................................................................................15
UFB/UFN-BA-e-1011
2
UFB/UFN-BA-e-1011
3
7 Operation ......................................................................................................... 17
7.1 Start-up.......................................................................................................................17
7.2 Switching Off ..............................................................................................................17
7.3 Zeroing .......................................................................................................................17
7.4 Simple weighing .........................................................................................................17
7.5 Weighing with tare ......................................................................................................18
7.6 Weighing with tolerance range ...................................................................................18
7.7 Manual totalizing.........................................................................................................21
7.8 Automatic adding-up...................................................................................................23
7.9 Animal weighing .........................................................................................................24
7.10 Lock keyboard ............................................................................................................24
7.11 Display background illumination .................................................................................24
7.12 Automatic switch-off function “AUTO OFF“ ...................................................................25
8 Menu................................................................................................................. 26
9 Service, maintenance, disposal ..................................................................... 28
9.1 Cleaning .....................................................................................................................28
9.2 Service, maintenance .................................................................................................28
9.3 Disposal......................................................................................................................28
9.4 Error messages ..........................................................................................................28
10 Data output RS 232C ................................................................................... 29
10.1 Technical Data............................................................................................................29
10.2 Printer mode ...............................................................................................................30
10.3 Continuous data output ..............................................................................................30
11 Instant help................................................................................................... 31
UFB/UFN-BA-e-1011
4
1 Technical Data
KERN UFB 600K200M UFB 1.5T0.5M
Readability (d) 200 g 500 g
Weighing range (max) 600 kg 1500 kg
Minimum load (Min) 4 kg 10 kg
Verification value (e) 200 g 500 g
Verification class III III
Reproducibility 200 g 500 g
Linearity ± 200 g ± 500 g
Recommended adjustment weight, not added (class)
600 kg
(M2)
1.5 t (M2)
Warm-up time 10 minutes.
Stabilization time (typical) 2-3 sec.
Weighing unit kg
Auto Off Available options 5, 15 min.
Ambient temperature -10°C – 40°C
Moist environment 0 %- 80 % (non-condensing)
Input voltage 220 V – 240 V, 50 Hz
Electric Supply
Power pack secondary voltage 9V, 800mA
Dimensions display unit (B x D x H) mm
250 x 160 x 58
Dimensions platform (B x T x H) mm
1100 x 1460 x 90
Weighing surface mm 1100 x 1300
Interface (Standard) RS 232
UFB/UFN-BA-e-1011
5
KERN UFN 600K200IPM UFN 1.5T0.5IPM
Readability (d) 200 g 500 g
Weighing range (max) 600 kg 1500 kg
Minimum load (Min) 4 kg 10 kg
Verification value (e) 200 g 500 g
Verification class III III
Reproducibility 200 g 500 g
Linearity ± 200 g ± 500 g
Recommended adjustment weight, not added (class)
600 kg
(M2)
1.5 t (M2)
Warm-up time 10 minutes
Stabilization time (typical) 2-3 sec.
Weighing unit kg
Auto Off Available options 5, 15 Min.
Ambient temperature -10°C – 40°C
Moist environment 0 %- 95 % (non-condensing)
Input voltage 220 V – 240 V, 50 Hz
Electric Supply
Power pack secondary voltage 9V, 800mA
Dimensions display unit (B x D x H) mm
266 x 165 x 96
Dimensions platform (B x T x H) mm
840 x 1350 x 90
Weighing surface mm 840 x 1190
IP protection IP 67 as per DIN 60529
Interface (Option) RS 232
2 Appliance overview display device
UFB: Plastic version UFN: Stainless steel version
1. Battery status display
2. Keyboard
3. Weight display
4. Tolerance tag, see chpt 7.6
5. Weighing unit
6. RS-232
7. Input terminal load cell cable
8. Guide rail support base / stand
9. Stop support base / stand
10. Mains adapter connection
11. Adjustment switch
UFB/UFN-BA-e-1011
6
2.1 Keyboard overview
Button Function
Turn on/off
Zeroing
Navigation key
Confirm entry
Taring
Navigation key
At numeric input increase flashing digit
Scroll forward in menu
Display sum total
Navigation key
Digit selection to the right
Add weighing value in summation memory
Navigation key
Digit selection to the left
Calculate weighing data via interface
C
Delete
Switch-over gross weight net weight
ESC
Back to menu/weighing mode
Activate animal weighing function
Activate weighing with tolerance limits
Delete total added memory
UFB/UFN-BA-e-1011
7
2.1.1 Numeric input via navigation keys
Press ; current setting appears. The first digit is flashing and can be
changed.
If the first digit is not to be changed, press and the second digit will start
flashing. Each time you press , the display unit jumps to the subsequent digit, returning to the first digit after the last digit has been pressed.
To change the selected (flashing) digit, press
repeatedly until the desired
value appears. Then select by using additional digits and change these by
using
Finish entry with
2.2 Overview of displays
Display Significance
Rechargeable battery very low
STABLE Stability display
ZERO Zero display
GROSS Gross weight
NET Net weight
AUTO Automatic add-up enabled
Kg Weighing unit
M+ Adding
LED
+ / / -
Indicators for weighing with tolerance limits
UFB/UFN-BA-e-1011
8
UFB/UFN-BA-e-1011
9
3 Basic Information (General)
3.1 Proper use
The display unit acquired by you is used in combination with a weighing plate and serves to determine the weighing value of material to be weighed. It is intended to be used as a “non-automatic weighing system”, i.e. the material to be weighed is manually and carefully placed in the centre of the weighing plate. As soon as a stable weighing value is reached the weighing value can be read.
3.2 Improper Use
Do not use display unit for dynamic weighings. In the event that small quantities are removed or added to the material to be weighed, incorrect weighing results can be displayed due to the “stability compensation“ in the display unit. (Example: Slowly draining fluids from a container on the balance.) Do not leave permanent load on the weighing plate. This may damage the measuring system. Impacts and overloading exceeding the stated maximum load (max) of the weighing plate, minus a possibly existing tare load, must be strictly avoided. Both, the weighing plate and the display unit may be damaged during this process. Never operate display unit in explosive environment. The serial version is not explosion protected. Changes to the display unit's design are not permitted. This may lead to incorrect weighing results, safety-related faults and destruction of the display unit. The display unit may only be operated in accordance with the described default settings. Other areas of use must be released by KERN in writing.
3.3 Warranty
Warranty claims shall be voided in case
Our conditions in the operation manual are ignored
The appliance is used outside the described uses
The appliance is modified or opened
Mechanical damage or damage by media, liquids, natural wear and tear
The appliance is improperly set up or incorrectly electrically connected
The measuring system is overloaded
3.4 Monitoring of Test Resources
In the framework of quality assurance the measuring-related properties of the display unit and, if applicable, the testing weight, must be checked regularly. The responsible user must define a suitable interval as well as type and scope of this test. Information is available on KERN’s home page (www.kern-sohn.com with regard to the monitoring of display units’ test substances and the test weights required for this. In KERN’s accredited DKD calibration laboratory test weights and display units may be calibrated (return to the national standard) fast and at moderate cost.
4 Basic Safety Precautions
4.1 Pay attention to the instructions in the Operation Manual
Carefully read this operation manual before setup and commissioning, even if you are already familiar with KERN balances.
4.2 Personnel training
The appliance may only be operated and maintained by trained personnel.
5 Transportation & Storage
5.1 Testing upon acceptance
When receiving the appliance, please check packaging immediately, and the appliance itself when unpacking for possible visible damage.
5.2 Packaging / return transport
Keep all parts of the original packaging for a possibly
required return.
Only use original packaging for returning.
Prior to dispatch disconnect all cables and remove
loose/mobile parts.
Reattach possibly supplied transport securing devices.
Secure all parts such as glass wind screen, weighing
platform, power unit etc. against shifting and damage.
6 Unpacking and implantation
6.1 Installation Site, Location of Use
The display units are designed in a way that reliable weighing results are achieved in common conditions of use. Precise and fast work is achieved by selecting the right place for your display unit and your weighing plate.
On the installation site observe the following:
Place the display unit and the weighing plate on a stable, even surface.
Avoid extreme heat as well as temperature fluctuation caused by installing
next to a radiator or in the direct sunlight;
Protect the display unit and the weighing plate against direct draft from open windows or doors.
Avoid jarring during weighing;
Protect the display unit and the weighing plate against high humidity, vapours
and dust.
UFB/UFN-BA-e-1011
10
Loading...