KERN Precision balances EWJ series Non-approved models, 0,001 g, 300 g, EWJ 300-3 (W) User guide

Page 1
KERN & Sohn GmbH
Ziegelei 1
E-Mail: info@kern-sohn.com
Operating manual Precision balances
KERN EWJ
Version 1.2
08/2014
GB
D-72336 Balingen
Fax: +49-[0]7433-9933-149
EWJ-BA-e-1412
Page 2
GB
KERN EWJ
Precision balance
Version 1.2 08/2014
Operating manual
Contents
1 Technical data ................................................................................................ 4
2 Appliance overview ....................................................................................... 6
2.1 Keyboard overview ..................................................................................................................... 8
2.2 Overview of display .................................................................................................................... 9
3 Basic Information (Gen eral) ........................................................................ 10
3.1 Proper use ................................................................................................................................ 10
3.2 Improper Use ............................................................................................................................ 10
3.3 Warranty ................................................................................................................................... 10
3.4 Monitoring of Test Resources................................................................................................... 11
4 Basic Safety Precauti o ns ............................................................................ 11
4.1 Pay attention to the instructions in the Operation Manual ........................................................ 11
4.2 Personnel training ..................................................................................................................... 11
5 Transport and storage ................................................................................. 11
5.1 Testing upon acceptance ......................................................................................................... 11
5.2 Packaging / return transport ..................................................................................................... 11
6 Unpacking, Setup and Commissioning ..................................................... 12
6.1 Installation Site, Location of Use .............................................................................................. 12
6.2 Unpacking, Scope of delivery ................................................................................................... 12
6.2.1 Scope of delivery / serial accessories: ..................................................................................... 12
6.2.2 Installing / removing transport fittings ....................................................................................... 13
6.3 Mains connection ...................................................................................................................... 13
6.4 Storage battery operation (optional) ......................................................................................... 14
6.5 Connection of peripheral devices ............................................................................................. 14
6.6 Initial Commissioning ................................................................................................................ 14
6.7 Adjustment ................................................................................................................................ 15
6.7.1 Manual internal adjustment by pressing button ........................................................................ 15
6.7.2 Automatic internal adjustment .................................................................................................. 16
6.8 Verification ................................................................................................................................ 17
7 Operation ...................................................................................................... 18
7.1 Start-up ..................................................................................................................................... 18
7.2 Switching Off ............................................................................................................................ 18
7.3 Zeroing...................................................................................................................................... 18
7.6 Percent determination .............................................................................................................. 19
7.7 Parts counting ........................................................................................................................... 20
7.8 Manual totalizing ....................................................................................................................... 21
7.9 Automatic adding-up ................................................................................................................. 24
2 EWJ-BA-e-1412
Page 3
8 Menu ............................................................................................................. 26
8.1 Navigation in the menu ............................................................................................................. 26
8.2 Access to technology menu...................................................................................................... 27
8.3 Overview ................................................................................................................................... 28
9 Interfaces ...................................................................................................... 31
9.1 Technical data .......................................................................................................................... 31
9.2 Printer operation (RS 232)........................................................................................................ 32
9.3 Output log (continuous output) ................................................................................................. 33
10 Servicing, maintenance, disposal .............................................................. 33
10.1 Clean ........................................................................................................................................ 33
10.2 Servicing, maintenance ............................................................................................................ 33
10.3 Disposal .................................................................................................................................... 33
11 Instant help ................................................................................................... 34
12 Declaration of conformity ........................................................................... 35
EWJ-BA-e-1412 3
Page 4

1 Technical data

KERN EWJ 300-3 EWJ 300-3H EWJ 3000-2
Readability (d) 0.001 g 0.001 g 0.01 g Weighing range (max) 300 g 300 g 3000 g Reproducibility 0.001g 0.001g 0.02 g Linearity ±0.003 g ±0.003 g ±0.05 g Smallest part weight for
piece counting Reference quantities at
piece counting Weighing Units Adjustment internal Warm-up time 2 hours Stabilization time (typical) 3 sec.
Operating temperature + 5° C .... + 40° C
Humidity of air max. 80 % (not condensing) Dimensions, completely
assembled (wind shield) (W x D x H) mm
Dimensions of the housi ng (B x D x H) mm
Dimensions of windshield inside (B x D x H) mm
2 mg 2 mg 20 mg
10, 20, 50, 100, 200
g, ct, dwt, lb, mo, oz, ozt, tl (HK), tl (Singap., Malays), tl (Tw)
220 x 315 x 180 220 x 315 x 321 220 x 315 x 180
220 x 315 x 95
145 x 160 x 80 155 x 175 x 217 -
Dimensions of windshield outside (B x D x H) mm
Weighing plate, stainless steel (mm)
Weight kg (net) 2200 g 2560 g 2900 g Input voltage balance 12 V / 2500 mA Rechargeable battery (optional) Service life – background illumination ON 10 h
Interfaces RS-232
4 EWJ-BA-e-1412
158 x 143 x 82 180 x 191 x 230 -
Ø 80 Ø 135
Operating time – background illumination OFF 15
Loading time 4h
USB
Page 5
KERN EWJ 600-2M EWJ 6000-1M
Readability (d) 0.01 g 0.1 g Weighing range (max) 600 g 6000 g Reproducibility 0.01 g 0.1 g Linearity ± 0,03 g ± 0.3 g Verification value (e) 100 mg 1 g Verification class II II Minimum weight (min) 500 mg 5 g Smallest part weight for
piece counting Reference quantities at
piece counting Weighing unit g g Adjustment internal Warm-up time 2 hours 2 hours Stabilization time (typical) 3 sec.
Operating temperature + 5° C .... + 40° C
Humidity of air max. 80 % (not condensing) Dimensions fully mounted (wind
shield) (W x D x H) mm Dimensions of the housi ng
(B x D x H) (mm) Dimensions of windshield
inside (B x D x H) mm
20 mg 20 mg
10, 20, 50, 100, 200
220 x 315 x 180 -
220 x 315 x 95
145 x 160 x 80 -
Dimensions of windshield outside (B x D x H) mm
Weighing plate, stainless steel (mm)
Weight kg (net) 2560 g 2900 g Input voltage balance 12 V / 2500 mA Rechargeable battery (optional) Service life – background illumination ON 10 h
Interfaces RS-232
EWJ-BA-e-1412 5
158 x 143 x 82 -
Ø 135 155 x 145
Operating time – background illumination OFF 15
Loading time 4h
USB
Page 6

2 Appliance overview

Example EWJ 300-3 / EWJ 600-2M:
1. Windshield
2. Weighing pan
3. Levelling screw
4. Bubble level
5. Keyboard
6. Display
7. RS-232
8. USB
9. Terminal power supply unit
10. Battery compartment
11. Transportation locks
12. Adjustment switch
6 EWJ-BA-e-1412
Page 7
Example EWJ 300-3H:
13. Windshield
14. Weighing pan
15. Display
16. Bubble level
17. Keyboard
18. Levelling screw
19. RS-232
20. USB
21. Terminal power supply unit
22. Battery compartment
23. Transportation locks
24. Adjustment switch
EWJ-BA-e-1412 7
Page 8

2.1 Keyboard overvie w

Key Function Function in Menu
Calculate weighing data via interface
Switch-over weighing unit Scroll forward in menu
Parts counting Delete total added m e mor y
Percent determination Start internal adjustment (longer
pressing of the button)
Taring
Zeroing Take over selected setting
Exit menu / back to weighing mode.
Turn on/off
8 EWJ-BA-e-1412
Page 9

2.2 Overview of display

Capacity display
Zero indicator The displayed weighing value is a net weighing value
The bar graph display moves from the left to the right and proceeds equally to the weight loaded onto the weighing balance. Its full width is reached at maximum load.
This is an analogue display of the current allocation of the weighing area.
ο
Pcs Indicator for counting
% Indicator for percent deter mination
fully loaded 1/2 loaded
empty
Stability display
Currently selected weight unit Loading status of the rechargeable battery (prerequisite
menu setting „P9batt on“, see chap. 8.2). The number of segments informs about the loading
status of the rechargeable battery.
EWJ-BA-e-1412 9
Page 10

3 Basic Information (General)

3.1 Proper use

The balance you purchased is intended to determine the weighing value of material to be weighed. It is intended to be used as a “non-automatic balance”, i.e. the material to be weighed is manually and carefully placed in the centre of the weighing pan. As soon as a stable weighing value is reached the weighing value can be read.

3.2 Improper Use

Do not use balance for dynamic weighing. In the event that small quantities are removed or added to the material to be weighed, incorrect weighing results can be displayed due to the “stability compensation“. (Example: Slowly draining fluids from a container on the balance.) Do not leave permanent load on the weighing pan. This m ay damage the measuring system. Impacts and overloading exceeding the stated maximum load (max) of the balance, minus a possibly existing tare load, must be strictly avoided. Balance may be damage by this. Never operate balance in explosive environment. The serial version is not explosion protected. The structure of the balance may not be modified. This may lead to incorrect weighing results, safety-related faul ts and des tr uct ion of the balance. The balance may only be used according to the described conditions. Other areas of use must be released by KERN in writing.

3.3 Warranty

Warranty claims shall be voided in case
Our conditions in the operation manual are ignored
The appliance is used outside the described uses
The appliance is modified or opened
mechanical damage and damage caused by media, liquids,
natural wear and tear
The appliance is improperly set up or incorrectly electrically connected
The measuring system is overloaded
10 EWJ-BA-e-1412
Page 11

3.4 Monitoring of Test Resources

In the framework of quality assurance the measuring-related properties of the balance and, if applicable, the testing weight, must be checked regularly. The responsible user must define a suitable interval as well as type and scope of this test. Information is available on KERN’s home page (www.kern-sohn.com with regard to the monitoring of balance test substances and the test weights required for this. In KERN's accredited DKD calibration laboratory test weights and balances may be calibrated (return to the national standard) fast and at moderate cost.

4 Basic Safety Precautions

4.1 Pay attention to the instructions in the Operation Manual

Carefully read this operation manual before setup and commissioning, even if you are already familiar with KERN balances.

4.2 Personnel training

The appliance may only be operated and maintained by trained personnel.
All language versions contain a non-binding translation. The original German is binding.

5 T ransport and storage

5.1 Testing upon acceptance

When receiving the appliance, please check packaging immediately, and the appliance itself when unpacking for possible visible damage.

5.2 Packaging / return transport

Keep all parts of the original packaging for a possibly required
return.
Only use original packaging for returning. Prior to dispatch disconnect all cables and remove loose/mobile
parts.
Reattach possibly supplied transport securing devices. Secure all parts such as the glass wind screen, the weighing
platform, power unit etc. against shifting and damage.
EWJ-BA-e-1412 11
Page 12

6 Unpacking, Setup and Commi s si oning

Balance, see chap. 2

6.1 Installation Site, Location of Use

The balances are designed in a way that reliable weighing results are achieved in common conditions of use. You will work accurately and fast, if you select the right location for your balance.
Therefore, observe the following for the installation site:
Place the balance on a firm, level surface;
Avoid extreme heat as well as temperature fluctuation caused by installing
next to a radiator or in the direct sunlight;
Protect the balance against direct draughts due to open windows and doors;
Avoid jarring during weighing;
Protect the balance against high humidity, vapours and dust;
Do not expose the device to extreme dampness for longer periods of time.
Non-permitted condensation (co ndensation of air humidity on the appliance) may occur if a cold appliance is taken to a considerably warmer environment. In this case, acclimatize the disconnected appliance for ca. 2 hours at room temperature.
Avoid static charge of goods to be weighed or weighing container.
Major display deviations (incorrect weighing results) may be experienced should electromagnetic fields (e.g. due to mobile phones or radio equipment), static electricity accumulations or instable power supply occur. Change location or remove source of interference.

6.2 Unpacking, Scope of delivery

Remove device and accessories carefully from packaging, remove packaging material and place device at the planned work place. Verify that there has been no damage and that all packing items are present.

6.2.1 Scope of delivery / serial accessories:

Mains adapter
Protective cover
Operating manual
Transport Securing
Glass wind shield only models EWJ 300-3, EWJ 300-3H, EWJ 600-2M
12 EWJ-BA-e-1412
Page 13

6.2.2 Installing / removing transport fittings

Removing transport locking devices
Level balance with foot screws until the air bubble of the water balance is in the
prescribed circle.
Check levelling regularly
The right place is decisive for the accuracy of the weighing results of high-resolution precision balances (see chap. 6.1).
Install weighing plate and wind shield if necessary.

6.3 Mains connection

Power is supplied via the external mains adapter. The stated voltage value must be the same as the local voltage. Only use KERN original mains adapter. Using other makes requires consent by KERN.
EWJ-BA-e-1412 13
Page 14

6.4 Storage battery operation (optional)

Before the first use, the battery should be charged by connecting it to the mains power supply for at least 12 hours. The LED display provides information about the battery's charging status.
Voltage has dropped below prescribed minimum.
Rechargeable battery very low.
Rechargeable battery completely reloaded
To spare the rechargeable battery the permanent background illumination of the display can be switched off in the menu item „F2 bl“, see chapter 8.2.

6.5 Connection of peripheral devices

Before connecting or disconnecting of additional devices (printer, PC) to the data interface, always disconnect the balance from the power supply. With your balance, only use accessories and peripheral devices by KERN, as they are ideally tuned to your balance.

6.6 Initial Commissioning

In order to obtain exact results with the electronic balances, your balance must have reached the operating temperature (see warming up time chap. 1). During this warming up time the balance must be connected to the power supply (mains, accumulator or battery). The accuracy of the balance depends on the local acceleration of gravity. Strictly observe hints in chapter Adjustment.
14 EWJ-BA-e-1412
Page 15

6.7 Adjustment

warm-up time.
As the acceleration value due to gravity is not the same at every location on earth, each display unit with connected weighing plate must be coordinated - in compliance with the underlying physical weighing principle - to the existing acceleration due to gravity at its place of location (only if the weighing system has not already been adjusted to the location in the factory). This adjustment process must be carried out for the first commissioning, after each change of location as well as in case of fluctuating environment temperature. To receive accurate measuring values it is also recommended to adjust the display unit periodically in weighing operation.
Observe stable environmental conditions. Stabilisation requires a certain

6.7.1 Manual internal adjustment by pressing button

In weighing mode keep pressed as long as „CAL“ is displayed
The motor noise of the loading system for the internal adjustment weight can be
heard, the internal adjustment is started. After successful adjustment „PASS“ will be displayed. The balance returns automatically into weighing mode.
EWJ-BA-e-1412 15
Page 16

6.7.2 Automatic internal adjustment

Automatic adjustment takes place:
when the balance is switched off and on.
at the end of a time interval
After a set time interval (selectable 1 – 8 hrs.) in the menu (F5 HoUr, see chap.
8.3) the internal adjustment is automatically started.
The motor noise of the loading system for the internal adjustment weight can be
heard, the internal adjustment is started. After successful adjustment „PASS“ will be displayed. The balance returns automatically into weighing mode.
16 EWJ-BA-e-1412
Page 17

6.8 Verification General introduction:

According to EU directive 90/384/EEC or 2009/23EG b al ances must be officially verified if they are used as follows (legally controlled area):
a) For commercial transactions if the price of goods is determined by weighing. b) For the production of medicines in pharmacies as well as for analyses in the
medical and pharmaceutical laboratory. c) For official purposes d) For manufacturing final packages
In cases of doubt, please contact your local trade in standard. Verification notes:
An EU type approval exists for balances described in their technical data as verifiable. If a balance is used where obligation to verify exists as described above, it must be verified and re-verified at regular intervals. Re-verification of a balance is carried out according to the respective national regulations. The validity for verification of balances in Germany is e.g. 2 years. The legal regulation of the country where the balance is used must be observed!
Verification of the balance is invalid without the seal.
The seal marks attached on balances with type approval point out that the balance may only be opened and serviced by trained and authorised specialist staff. If the seal mark is destroyed, verification looses its validity. Please observe all national laws and legal regulations. In Germany a re­verification will be necessary.
Position of seals and adjusting switch:
1. Self-destroying seal mark
2. Plastic disk to cover the adjustment switch
3. Adjustment switch
4. Lead
5. Wire
6. Housing screw
EWJ-BA-e-1412 17
Page 18

7 Operation

Overload warning
sound. Unload weighing system or reduce preload.

7.1 Start-up

Press .
The display is shining and the motor noise of the loading system for t he int er nal adjustment weight can be heard. The balance carries out a selftest, the maximum load and software version will also be shortly displayed, followed by the internal adjustment. During this process „CAL“ appears in the display. As soon as the weight display appears, the balance is ready for weighing.

7.2 Switching Off

Press , the display will disappear.

7.3 Zeroing

Resetting to zero corrects the influence of light soiling on the weighing plate.
Unload the balance
Press and zero display as well as indicator will appear.
7.4 Simple weighing
Place goods to be weighed on balance. Wait for stability display .
Read weighing result.
Overloading exceeding the stated maximum load (max) of the device, minus a possibly existing tare load, must be strictly avoided. This could damage the instrument. Exceeding maximum load is indicated by the display of „----“ and an audio
18 EWJ-BA-e-1412
Page 19
7.5 Weighing with tare
The balance is able to only store one taring value at a time. When the balance is unloaded the saved taring value is displayed with
when the taring range capacit y is full .
Deposit empty weighing container. Wait for stability display, then press .
Zero display appears. The weight of the container is now internally saved.
Weigh the material, the net weight will be indicated.
negative sign.
To delete the stored tare value remove load form the weighing plate and press .
The taring process can be repeated any number of times, e.g. when adding several components for a mixture (adding). The limit is reached

7.6 Percent determination

Percent weighing allows to display weight in percent, in relation to a reference weight.
Put the nominal weight
Place the nominal weight (reference weight which corresponds to 100 %).
Wait for stability display, then press . 100% is displayed.
Percent weighing /commutation
Place goods to be weighed on balance.
The weight of the item to be weighed is displayed in percent, with reference to the nominal weight.
Press , the weight of the item to be weighed is displayed in the current
weighing unit e.g. gram.
EWJ-BA-e-1412 19
Page 20

7.7 Parts counting

Before the balance can count parts, it must know the average part weight (i.e. reference). Proce ed by putting on a certain number of the parts to be counted. The balance determines the total weight and divides it by the number of parts, the so­called reference quantity. Counting is then carried out on the basis of the calculated average piece weight. As a rule: The higher the reference quantity the higher the counting exactness.
Set reference
Press , the current reference quantity (e.g. 10) and the indicator Pcs are
displayed.
Use to set the desired reference quantity (e.g. 100), selectable SP 10, SP
20, SP 50, SP100, SP 200.
Place as many items to be counted (such as 100 items) as demanded by the set
reference quantity and c on fir m by . The weighing scales calculate the reference weight. The current quantity (such as 100 items) will be displayed.
Remove reference weight. The balance is from now in parts counting mode
counting all units on the weighing plate.
Switching over between quantity and weight display
Place load on pan and read the number of pieces.
 Press , the weight will be displayed.
20 EWJ-BA-e-1412
Page 21

7.8 Manual totalizing

For menu settings, see chapter 8.2:
The totalizing function is not active when the weight is under 20d.
With this function the individual weighing values are added into the summation memory by pressing and edited, when an optional printer is connected.
The totalizing function is only available at menu setting „SALE-Mode no“, see chap. 8.2.
„F3 COM“  „S 232“  „P Prt“
Add up:
Place item to be weighed A, e.g. 100 g.
Wait for stability display, then press . The weight value will be saved and printed if an optional printer is connected. The number of weighings, followed by the total weight will be indicated.
„SALE n“
Remove the weighed good. More weighed goods can only be added when the
display ≤ zero.
EWJ-BA-e-1412 21
Page 22
Place item to be weighed B, e.g. 200 g.
Wait for stability display, then press . The weight value will be added to the summation memory and edited. Number of weighings, followed by the total weight will be displayed for 2 sec. After that the current weighing value is displayed.
Add more weighed goods as described before.
Please note that the weighing system must be unloaded between the individual weighing procedures.
This process may be repeated 99 times or till such time as the capacity of the weighing system has been exhausted.
22 EWJ-BA-e-1412
Page 23
Display and output sum „Total“:
1:
100.00 g
First weighing
G:
100.00 g
2:
200.00 g
Second weighing
G:
200.00 g
1-2:
300.00 g
Total of weighing proces s es 1 - 2
When the balance is unloaded (zero display) press , the number of
weighings, followed by the total weight will be shown for 2 sec and printed if an optional printer is connected.
Delete total added memory:
When display „Sum „Tota l “ “ appears, press . The data in the summation
memory are deleted.
Printout example (KERN YKB-01N):
EWJ-BA-e-1412 23
Page 24

7.9 Automatic adding-up

Menu settings, chap. 8.2:
The totalizing function is not active when the weight is under 20d.
With this function the individual weighing values are automatically added into the summation memory when the bala nce is unloaded without pressi n g and edited,
when an optional printer is connected.
The totalizing function is only available at menu setting „SALE-Mode no“, see chap. 8.2.
„F3 COM“  „S 232  „P AU t o“
Add up:
Place item to be weighed A, e.g. 100 g.
After stabilisation control has taken place, you will hear an audio sound.
„SALE n“
Remove the weighed good. The weighing value is added to the summation
memory and printed if an optional printer is connected.
More weighed goods can only be added when the display ≤ zero. Place item to be weighed B, e.g. 200 g.
After stabilisation control has taken place, you will hear an audio sound.
24 EWJ-BA-e-1412
Page 25
Remove the weighed good. The weighing value is added to the summation
7.9.
memory and printed if an optional printer is connected. Number of weighings, followed by the total weight will be displayed for 2 sec.
Add more weighed goods as described before.
Please note that the weighing system must be unloaded between the individual weighing procedures.
This process may be repeated 99 times or till such time as the capacity of the weighing system has been exhausted.
Display and delete the weighing data, as well as printout examples see chap.
EWJ-BA-e-1412 25
Page 26

8 Menu

selected one after the other.
current setting will be displayed.

8.1 Navigation in the menu Call up menu

Select menu item
Select setting
Change settings
Acknowledge setting / exit the menu
Return to weighing mode
Switch-on balance and during the selftest press .
The first menu item „F1 Unt„ is displayed.
With help of , the individual menu items can be
Confirm selected menu item by pressing . The
Switch into the available settings using .
Either save by pressing or cancel by pressing .
Press repeatedly to exit menu.
26 EWJ-BA-e-1412
Page 27

8.2 Access to technology menu

, , .
subject to verification.
The access to the technology menu „tECH“ is locked by the key combination
When on balances with type approval „tECH“ is displayed, the seal mark must be destroyed and the adjustment switch be actuated. Position of adjustment switch see chap. 6.11
Attention: After destruction of the seal the balance must be re-verified by an authorised agency and a new verification wire/seal mark fitted before it can be reused for applications
EWJ-BA-e-1412 27
Page 28

8.3 Overview

F3 Com
P Prt*
Output of a stable weighing value after pressing
to the summation memory and issued.
P Cont
Continuous data output see chap. 9.3
P AUto
For automatic add-up see chap. 7.10.
memory on unloading of weighing scale.
wirel
Not documented
Remote control instructions
Command
Function
S
Stable weighing value for the weight is sent via the interface
W
Weighing value for the weight (stable or unstable) is sent via the interface
T
No data are sent, the balance carries out the tare function.
Z
No data are sent, the zero-display appears.
P
Quantity will be sent via the interface
Acknowledge selection by .
Factory settings are marked by *.
Menu block Menu item Available settings / explanation F1 Unt
Weighing Units
F2 bl Display
background illumination
Interface parameter
Not documented
EL AU*
EL on
Automatic background illumination on when weighing pate is loaded or key pressed.
Background lighting of display is switched on permanently
EO oFF Display background illumination off
S 232
Use to select interface: RS232 or USB
S USb
of (menu setting „F4 ACC oFF“)
Manual totalizing (menu setting „F4 ACC on“),
see chap. 7.9. Press and the weighing value will be added
P ASK
Acknowledge selection by . b600
b 9600*
This function is used to issue and add individual weighing values automatically to the summation
Baud rate 600, 1200, 2400, 4800, 9600 selectable.
28 EWJ-BA-e-1412
Page 29
Acknowledge selection by .
Eng*
Standard stetting English. only displayed for setting „LP 50“
chi
F4 SPD
SPd L
Verifiable models: “Low”
Non-verifiable models:
SPd 1
F5 HoUr
1 HoUr 8 HoUr
SAL E m
EWJ 300 -3: d= 0.001 g
EWJ 600 -2M: d= 0.01 g
EWJ 6000-1M: d= 0.1 g
EWJ 300 -3: d= 0.01 g
EWJ 600-2M: d= 0.1 g
EWJ 6000-1M: d= 1 g
applications subject t o v er i ficati on.
Display speed
tP Standard printer setting LP 50 Not documented
Not documented
SPd n “Normal” SPd 2 SPd H “High” SPd 3 SPd 4
oFF Automatic adjustment switched off
bAttoF Mask loading status display „Recharg.battery“
P6 bAtt
bAtton Display loading status display „Recharg.battery“
The SALE mode is locked for balances with type approval.
To disable the access lock, destroy the seal and actuate the adjustment switch. Position of the adjustment switch see chap. 6.11 Attention: After destruction of the seal the balance must be re-verified by an authorised agency and a new verification wire/seal mark fitted before it can be reused for
SALE n
SALE y
Time interval after which the automatic adjustment starts, selectable 1, 2, 3,4, 5, 6, 7, 8 hours.
Sale mode no: d= 0.1g
Sale mode yes: d= 0.01 g
EWJ-BA-e-1412 29
Page 30
XXXXX X
P4 A 2n
A2n
0.5d
A2n 1d
A2n 2d*
A2n 4d
XXXXX X
P6 CAP
tECH
Pin
P1 Lin Linearisation (not documented) P2 CAL Adjustment (not documented)
P3 Cnt
P5 GrA
Technology menu, see chap. 8.2
At Pin“ display press , , subsequently the first menu block P1 Linwill be displayed.
Display internal resolution
A2 oFF Automatic zero point correction switched off
Automatic zero point correction (Autozero) by changing the display, digits selectable (0.5d, 1d, 2d, 4d)
Local gravitational constant (not documented)
XXXX Capacity (max)
30 EWJ-BA-e-1412
Page 31

9 Interfaces

For menu settings, see chapter 8.2:
„F3 COM“ „S 232“
For menu settings, see chapter 8.2:
„F3 COM“ „USB“
Suitable peripheral devices:
Suitable peripheral devices:
connection).
Pin 5 signal earth
Via the interfaces weighing data may be exchanged with connected peripheral devices.
RS 232 interface USB interface for PC connect io n
Printer
PC
PC
On the PC a virtual COM-Port is installed, which is recognized and triggered by the PC software (e.g. KERN balance
We recommend the USB interface set KERN DBS A02 (scope of supply: USB cable, driver CD, software balance connection.)
For further information please go to KERN-Homepage (www.kern-sohn.com).
The following conditions must be met to provide successful communication between the weighing balance and the peripheral devices.
Connect balance using a suitable cable with the interface of the peripheral device. Faultless operation requires an adequate KERN interface cable.
Communication parameters (baud rate, bits and parity) of balance and peripheral device must match.

9.1 Technical data

Connection (RS 232) 9 pin d-subminiature bushing
Baud rate Optional 600/1200/2400/4800/9600 Parity 8 bits, no parity
EWJ-BA-e-1412 31
Pin 2 input Pin 3 output
Page 32

9.2 Printer operation (RS 232)

1:
49.99g
G
49.99g
1:
49.99g
G
49.99g
3:
149.99g
G
149.99g
1-3
299.97g
Printout examples (KERN YKB-01N):
1. Menu setting F3 COM „P Prt“
Gross weight G 300.00g
Net weight N: 100.0g
Percent determination PERC: 50.01 %
Parts counting PCS
UW: G
Totalization
2. Menu setting F3 COM „P Cont“
20PCS
5.00027g 100g
stable / gross ST,GS: 50.00g
stable / net ST,NT: 50.0g
unstable / gross UT,GS: 50.00g
unstable / net UT,NT: 50.0g
Weighing values ≤ zero are not edited via the interface.
32 EWJ-BA-e-1412
Page 33

9.3 Output log (continuous output)

Before any maintenance, cleaning and repair work disconnect appliance from the oper ati ng v ol tag e.
HEADER1: ST = stable, US = instable HEADER2: NT = net , GS = gross

10 Servic ing, maintenance, disposal

the

10.1 Clean

Please do not use aggressive cleaning agents (solvents or similar agents), but a cloth dampened with mild soap suds. Ensure that no liquid penetrates into the device. Polish with a dry soft cloth. Loose residue sample/powder can be removed carefully with a brush or manual vacuum cleaner.
Spilled weighing goods must be removed immediately.

10.2 Servicing, maintenance

The appliance may only be opened by trained service technicians who are
authorized by KERN.
Before opening, disconnect from power supply.

10.3 Disposal

Disposal of packaging and appliance must be carried out by operator according to valid national or regional law of the location where the appliance is used.
EWJ-BA-e-1412 33
Page 34

11 Instant hel p

The displayed weight does
The displayed weight is
The weighing result is
In case of an error in the program process, briefly turn off the balance and disconnect from power supply. The weighing process must then be restarted from the beginning.
Help:
Fault Possible cause
not glow.
permanently changing
obviously incorrect
The balance is not switched on.
The mains supply connection has been interrupted
(mains cable not plugged in/ faul ty).
Power supply interrupted.
Draught/air movement
Table/floor vibrations
Weighing pan has contact with other objects.
Electromagnetic fields / static charging (choose
different location/switch off interfering device if possible)
The display of the balance is not at zero
Adjustment is no longer correct.
The balance is on an uneven surface.
Should other error messages occur, switch balance off and then on again. If the error message remains inform manufacturer.
Great fluctuations in temperature.
Warm-up time was ignored.
Electromagnetic fields / static charging (choose
different location/switch off interfering device if possible)
34 EWJ-BA-e-1412
Page 35

12 Declaration of conformit y

KERN & Sohn GmbH
D-72322 Balingen-Frommern
E-Mail: info@kern-sohn.de
Tel: 0049-[0]7433- 9933-0
Internet: www.kern-sohn.de
D
Konformitäts­erklärung
Wir erklären hierm it, dass das Produkt , auf das sich diese Erk lärung bezieht, mit den nachstehenden Normen übereinstimmt.
GB
Declaration of conformity
We hereby declare that the product to which this dec laration refers conforms with the following standards.
CZ
Prohlášení o shode
Tímto prohlašujem e, že v ýrobek , k terého se toto proh láš ení t ýká, je v souladu s níže uvedenými normami.
E
Declaración de conformidad
Manifestamos en la presente que el producto al que se refiere esta declaración está de acuerdo con las normas siguientes
F
Déclaration de conformité
Nous déclarons avec cela res ponsabilité que le produit, auquel s e rapporte la présente déclaration, est conforme aux normes citées ci-après.
I
Dichiarazione di conformitá
Dichiariamo con ciò che il prodotto al quale la presente dichiarazione si riferisce è conforme alle norme di seguito citate.
NL
Conformiteit­verklaring
Wij verklaren hiermede dat het product, waarop deze verklaring betrekking heeft, met de hierna vermelde normen overeenstemt.
P
Declaração de conformidade
Declaramos por meio da presente que o produto no qual se refere esta declaração, corresponde às normas seguintes.
PL
Deklaracja
zgodności
Niniejszym oświadczamy, że produkt, którego niniejsze oświadczenie dotyczy,
jest zgodny z poniższymi normami.
RUS
Заявление о
соответствии
Мы заявляем, что продукт, к которому относится данная декларация,
соответствует перечисленным ниже нормам.
Signature
Datum
23.12.2013
Ort der Ausstellung
Place of issue
72336 Balingen
Albert Sauter KERN & Sohn GmbH
Geschäftsführer
Managing director
KERN & Sohn GmbH, Ziegelei 1, D-72336 Balingen, Tel. +49-[0]7433/9933-0 Fax +49-[0]7433/9933-149, E-Mail: info@kern-sohn.com, Internet: www.kern-sohn.com
Postfach 4052
Fax: 0049-[0]7433-9933-149
Declaration of conformity
EG-Konformitätserklärung EC-Declaration of -Conformity EC-
Déclaration de conformité EC-Declaración de Conformidad
EC-Dichiarazione di conformità EC-Conformiteitverklaring EC- Declaração de conformidade EC- Prohlášení o shode EC-Deklaracja zgodności EC-Заявление о соответствии
Electronic Balan ce: KERN EWJ
EU Directive Standards
2004/108/EC EN 55022: 2010
EN 61000-3-3: 2008 EN 55024: 2010
2006/95/EC EN 60950: 2006+A11:2009
Date
EWJ-BA-e-1412 35
Signatur
Loading...