Electronic Balance: PLE-N
PLE-N-BA-e-1222 5
6
3 Basic Information (General)
3.1 Proper use
The balance you purchased is intended to determine the weighing value of material
to be weighed. It is intended to be used as a “non-automatic“ balance, i.e. the
material to be weighed is manually and carefully placed in the centre of the weighing
plate. As soon as a stable weighing value is reached the weighing value can be read.
3.2 Improper Use
Do not use balance for dynamic weighing. In the event that small quantities are
removed or added to the material to be weighed, incorrect weighing results can be
displayed due to the “stability compensation“ in the balance. (Example: Slowly
draining fluids from a container on the balance.)
Do not leave permanent load on the weighing plate. This may damage the
measuring system.
Impacts and overloading exceeding the stated maximum load (max) of the balance,
minus a possibly existing tare load, must be strictly avoided. Balance may be
damage by this.
Never operate balance in explosive environment. The serial version is not explosion
protected.
The structure of the balance may not be modified. This may lead to incorrect
weighing results, safety-related faults and destruction of the balance.
The balance may only be used according to the described conditions. Other areas of
use must be released by KERN in writing.
3.3 Warranty
Warranty claims shall be voided in case
Our conditions in the operation manual are ignored
The appliance is used outside the described uses
The appliance is modified or opened
Mechanical damage or damage by media, liquids, natural wear and tear
The appliance is improperly set up or incorrectly electrically connected
The measuring system is overloaded
3.4 Monitoring of Test Resources
In the framework of quality assurance the measuring-related properties of the
balance and, if applicable, the testing weight, must be checked regularly. The
responsible user must define a suitable interval as well as type and scope of this
test. Information is available on KERN’s home page (www.kern-sohn.com with
regard to the monitoring of balance test substances and the test weights required for
this. In KERN’s accredited DKD calibration laboratory test weights and balances may
be calibrated (return to the national standard) fast and at moderate cost.
PLE-N-BA-e-1222
4 Basic Safety Precautions
Carefully read this operation manual before setup and
commissioning, even if you are already familiar with KERN
balances.
Keep all parts of the original packaging for a possibly required
return.
Only use original packaging for returning.
Prior to dispatch disconnect all cables and remove loose/mobile
parts.
Reattach possibly supplied transport securing devices.
Secure all parts such as the glass wind screen, the weighing
platform, power unit etc. against shifting and damage.
4.1 Pay attention to the instructions in the Operation Manual
4.2 Personnel training
The appliance may only be operated and maintained by trained personnel.
5 Transportation & Storage
5.1 Testing upon acceptance
When receiving the appliance, please check packaging immediately, and the
appliance itself when unpacking for possible visible damage.
5.2 Packaging / return transport
PLE-N-BA-e-1222 7
8
Level balance with foot screws until the air bubble of the
water balance is in the prescribed circle.
6 Unpacking, Setup and Commissioning
6.1 Installation Site, Location of Use
The balances are designed in a way that reliable weighing results are achieved in
common conditions of use.
You will work accurately and fast, if you select the right location for your balance.
Therefore, observe the following for the installation site:
Place the balance on a firm, level surface;
Avoid extreme heat as well as temperature fluctuation caused by installing
next to a radiator or in the direct sunlight;
Protect the balance against direct draughts due to open windows and doors;
Avoid jarring during weighing;
Protect the balance against high humidity, vapors and dust;
Do not expose the device to extreme dampness for longer periods of time.
Non-permitted condensation (condensation of air humidity on the appliance)
may occur if a cold appliance is taken to a considerably warmer environment.
In this case, acclimatize the disconnected appliance for ca. 2 hours at room
temperature.
Avoid static charge of goods to be weighed or weighing container.
Major display deviations (incorrect weighing results) may be experienced should
electromagnetic fields (e.g. due to mobile phones or radio equipment), static
electricity accumulations or instable power supply occur. Change location or remove
source of interference.
6.2 Unpacking
Carefully remove the balance from the packaging, remove plastic cover and setup
balance at the intended workstation.
6.2.1 Placing
6.2.2 Scope of delivery / serial accessories
Balance, Weighing plate
Mains power supply
Windshield
Operating Manual
PLE-N-BA-e-1222
6.3 Appliance overview
1. Weighing plate
2. RS232C interface
3. Foot screws
4. Mains adapter
connection
PLE-N-BA-e-1222 9
10
6.4 Controls
Key
Designation
Short key pressing
longtime pressed button
until the acoustic signal
gets mute
MENU button/
Call-up application
menu
Select menu items –
scroll forward
Call-up user menu
Exit user menu
Switch-over display
Arrow button
numerical input – scroll backward
ON/OFF switch
Turn on/off
Exit user menu
CAL button/
Adjustment
Select menu items – scroll backward
Arrow button
Numerical input – scroll forward
PRINT button
Calculate weighing data via interface
Confirm / store settings
Arrow button
Numerical input – cipher selection
0
TARE
TARE button
Taring
Zeroing
6.4.1 Overview of display
6.4.2 Keyboard overview
PLE-N-BA-e-1222
6.5 Connect and switch-on power supply
For verified balances a warming-up time of 30 minutes must be
observed.
After connecting the mains adapter a countdown starts.
Battery charge sufficient
Battery very low. Connect mains adapter as soon as possible
to load the rechargeable battery.
Voltage has dropped below prescribed minimum. Connect
mains adapter to load the rechargeable battery.
.
Before connecting the mains adapter check if the printed voltage value is the same
as the local supply voltage. Only use KERN original mains adapter. Using other
makes requires consent by KERN.
Plug-in mains adapter in mains adapter bushing of the balance and connect to
the mains.
The balance will carry out a self-test Then the balance is set into stand-by mode.
Press the ON/OFF key. When the zero display appears, the balance is ready for
operation. When weighing with internal adjustment weight, adjustment first
occurs automatically. During this process, „CAL“ will appear on the display.
Press the ON/OFF key anew. The balance is now in stand-by mode
6.6 Rechargeable battery operation (option)
The rechargeable battery is charged via the delivered power supply.
The operating time of the rechargeable battery is about 30h; charging time until
complete recharging ca. 10h.
In the menu you can activate the AUTO-OFF function time off], see chp. 9.8.
According to menu settings, the balance switches automatically off in order to spare
the battery.
When the balance is in battery mode the following symbols appear on the display:
PLE-N-BA-e-1222 11
12
6.7 Connection of peripheral devices
Before connecting or disconnecting of additional devices (printer, PC) to the data
interface, always disconnect the balance from the power supply.
With your balance, only use accessories and peripheral devices by KERN, as they
are ideally tuned to your balance.
6.8 Initial Commissioning
In order to obtain exact results with the electronic balances, your balance must have
reached the operating temperature (see warming up time chap. 1).
During this warming up time the balance must be connected to the power supply
(mains, accumulator or battery).
The accuracy of the balance depends on the local acceleration of gravity.
Strictly observe hints in chapter Adjustment.
6.8.1 Stability display
If the display shows the stability display [] the balance is in a stable status. If the
status is instable the [] display disappears.
6.8.2 Balance zero display
If an exact zero reading is not displayed on the balance in spite of the weighing dish
being empty, press the TARE button and the balance will start resetting to zero [ O]
.
7 Adjustment
As the acceleration value due to gravity is not the same at every location on earth,
each balance must be coordinated - in compliance with the underlying physical
weighing principle - to the existing acceleration due to gravity at its place of location
(only if the balance has not already been adjusted to the location in the factory). This
adjustment process must be carried out for the first commissioning, after each
change of location as well as in case of fluctuating environment temperature. To
receive accurate measuring values it is also recommended to adjust the balance
periodically in weighing operation.
Observe stable environmental conditions. A warming up time (see chapter 1)
is required for stabilization.
Ensure that there are no objects on the weighing plate.
PLE-N-BA-e-1222
Ensure that there are no objects on the weighing plate. Press the CAL key
Wait until the weighed value for the required adjustment weight appears
flashing.
During the flashing display put the required adjustment weight carefully in the
center of the weighing plate.
The flashing display disappears.
After successful adjustment the balance automatically returns to weighing
mode.
Take away adjustment weight
7.1.1 Adjustment with recommended adjustment weight (factory setting)
Weight value of the required adjustment weight see chpt. 1 “Technical
specifications“:
PLE-N-BA-e-1222 13
14
7.1.2 Adjustment with weights of other nominal values
Ensure that there are no objects on the weighing plate. Press the CAL button
and keep it pressed until the acoustic signal gets mute.
Wait until „load“ appears.
During the flashing display put the adjustment weight carefully in the center of
the weighing plate.
The flashing display disappears.
After successful adjustment the balance automatically returns to weighing
mode.
Take away adjustment weight
An error message will be displayed in the event of an adjustment error or
incorrect adjustment weight. Wait until the balance is again in weighing
mode and repeat the adjustment procedure.
Weights of different nominal values may be used for adjustment but are not optimal
for technical measuring, possible adjustment points see table 1.
Info about adjustment weights can be found on the Internet at: http://www.kernsohn.com
PLE-N-BA-e-1222
Start-up
In stand-by mode press ON/OFF button.
The balance is ready for weighing when the weight display
appears.
Switching Off
Press ON/OFF button, the balance returns to the stand-by
mode.
Simple weighing
Place goods to be weighed on balance
Wait until the stability display appears []
Read weighing result.
Taring
Place the weighing box and press the TARE button.
„0-t“ is displayed.
After standstill control the zero display appears.
The weight of the container is now internally saved.
Weigh the material, the net weight will be indicated.
The weight of the weighing container will be displayed as a
minus number after removing the weighing container.
The tare weight is saved until it is deleted. Remove the load
from the balance and press the TAREbutton. „0-t“ is
displayed, wait until the zero display appears.
The tare procedure can be repeated as many times as
necessary, for example with initial weighing of several
components for a mix (add-on weighing). The limit is
reached when the total weighing range capacity is full.
.
8 Basic Operation
PLE-N-BA-e-1222 15