KERN MSA 80 Operating Instructions Manual

KERN & Sohn GmbH
Ziegelei 1 D-72336 Balingen email: info@kern-sohn.com
Phone: +49-[0]7433- 9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com
Operating instructions Electronic height-measuring rod
KERN MSA 80
Version 1.0 10/2009 GB
MSA_80-BA-e-0910
GB
KERN MSA 80
Version 1.0 10/2009
Operating instructions Electronic height-measuring rod
Table of Contents
1 Device overview............................................................................................. 3
2 Technical Data ............................................................................................... 4
3 Declaration of conformity ............................................................................. 5
4 Basic instructions.......................................................................................... 6
5 Unpacking / Scope of delivery...................................................................... 7
6 How to insert the batteries............................................................................ 8
7 Assembly on baby scales KERN MBB ......................................................... 9
8 Operation...................................................................................................... 11
9 Cleaning, Maintenance, Disposal ............................................................... 14
2 MSA_80-BA-e-0910
1 Device overview
1. Measuring rod
2. Display unit
3. Caliper gauge/Heel stop
4. Head stop
MSA_80-BA-e-0910 3
4 MSA_80-BA-e-0910
2 Technical Data
´
KERN MSA 80
Measuring range 35 – 80 cm
Readability 1 mm
tolerance 5 mm
Units cm  ft/inch inch
Battery 2 x 1.5 V AAA
Operating period 600 h
Automatic cutout after 60 s
Measurements (W x H x D) mm, folded
625 x 295 x 70
Net weight 0.6 kg
Combinable scales
KERN MBB
3 Declaration of conformity
KERN & Sohn GmbH
D-72322 Balingen-Frommern Postbox 4052 email: info@kern-sohn.de
Phone: 0049-[0]7433- 9933-0 Fax: 0049-[0]7433-9933-149 Internet: www.kern-sohn.de
Declaration of conformity
EC-Konformitätserklärung EC-Declaration of -Conformity EC-
Déclaration de conformité EC-Declaración de Conformidad
EC-Dichiarazione di conformità EC-Conformiteitverklaring EC- Declaração de conformidade EC- Prohlášení o shode EC-Deklaracja zgodności EC-Заявление о соответствии
EN
Konformitäts­erklärung
Wir erklären hiermit, dass das Produkt, auf das sich diese Erklärung bezieht, mit den nachstehenden Normen übereinstimmt.
GB
Declaration of conformity
We hereby declare that the product to which this declaration refers conforms to the following standards.
CZ
Prohlášení o shode
Tímto prohlašujeme, že výrobek, kterého se toto prohlášení týká, je v souladu s níže uvedenými normami.
E
Declaración de conformidad
Manifestamos en la presente que el producto al que se refiere esta declaración está de acuerdo con las normas siguientes
F
Déclaration de conformité
Nous déclarons avec cela responsabilité que le produit, auquel se rapporte la présente déclaration, est conforme aux normes citées ci-après.
I
Dichiarazione di conformitá
Dichiariamo con ciò che il prodotto al quale la presente dichiarazione si riferisce è conforme alle norme di seguito citate.
NL
Conformiteit­verklaring
Wij verklaren hiermede dat het product, waarop deze verklaring betrekking heeft, met de hierna vermelde normen overeenstemt.
P
Declaração de conformidade
Declaramos por meio da presente que o produto no qual se refere esta declaração, corresponde às normas seguintes.
PL
Deklaracja zgodności
Niniejszym oświadczamy, że produkt, którego niniejsze oświadczenie dotyczy, jest zgodny z poniższymi normami.
RUS
Заявление о соответствии
Мы заявляем, что продукт, к которому относится данная декларация, соответствует перечисленным ниже нормам.
Height rod: KERN MSA 80, MSD 200, MSE 210
EU Directive Standards
2004/108/EC
EMC
EN 61000-6-3 : 2007, CISPR 16-2-3: 2003 EN 61000-6-1 : 2007 IEC61000-4-2: 1995+A1 : 1998+A2: 2000 IEC61000-4-3: 2008 IEC61000-4-8 : 1993+A1 : 2000
2006/95/EC LVD EN 60950 : 2006
Date: 22.09.2009 Signature:
Gottl. KERN & Sohn GmbH Management
Gottl. KERN & Sohn GmbH, Ziegelei 1, D-72336 Balingen, Tel. +49-[0]7433/9933-0,Fax +49-[0]7433/9933-149
MSA_80-BA-e-0910 5
4 Basic instructions
Carefully read this operation manual before setup and commissioning, even if you are already familiar with KERN products.
Staff training
The medical staff must apply and follow the operating instructions for proper use and care of the product.
Safety
Instructions
Assemble height measuring rod only on KERN MBB.
Please use no other than the supplied fixtures for mounting.
Ensure that mounting was carried out correctly and that all
screws have been tightened properly, see chapter 7 “Assembly”.
When moving the height measuring rod ensure that the person to be measured can not be injured
Reliable values of body height measurements are only achieved if the heel, back and head are aligned in a straight line. Please note that the body height of a person may vary by several cm as the day progresses.
Test device
control
We recommend a metrological examination of the accuracy of the measuring rod, however, this is not mandatory as the determination of human body height involves rather large, intrinsic inaccuracies.
6 MSA_80-BA-e-0910
5 Unpacking / Scope of delivery
Testing upon
acceptance
Please check packaging as well as the device on receipt for possibly visible external damages.
Packaging/
Return
Keep all parts of the original packaging for a possibly required return. Only use original packaging for returning.
Scope of supply
For height measuring rod, see chapter 1
Batteries, 2 x 1.5 V AAA
Assembly plate, see chap. 7 „Assembly“
2 off
Screw [A], see chap. 7 „Assembly“
2 off
Screw [B], see chap. 7 „Assembly“
Operating instructions
MSA_80-BA-e-0910 7
6 How to insert the batteries
Prior to initial use, insert the batteries as follows:
1. Remove the battery cover as shown on the illustration
2. Insert 2 x 1.5 V AAA batteries. Pay attention to correct polarity.
3. Reattach the battery cover.
To save battery power, the device auto-disconnects automatically after 60 seconds have passed without a change of display.
If the device is not used for a longer time, take out the batteries and store them separately. Leaking battery liquid could damage the device. Low batteries are indicated by the message “lo“. Change the batteries as described above.
8 MSA_80-BA-e-0910
7 Assembly on baby scales KERN MBB
1. Turn-over the balance. If assembled, remove weighing plate by loosening the screws.
2. Apply assembly plate acc. to fig. on the height measuring rod. Ensure that the fixing point engages.
3. Fasten the assembly plate using screws [A]. Screw height measuring rod on the weighing plate [B].
[B]
[A]
MSA_80-BA-e-0910 9
4. Assemble again weighing plate (see item 1.).
5. Turn over, balance and height measuring rod are ready for operation.
10 MSA_80-BA-e-0910
8 Operation
Keyboard
overview
Button Function
ON/OFF Turn on/off
UNIT Switching between units
(cm ft/inch inch)
HOLD “Freeze” measurement result
RESET Reset scale (35 cm)
Turn on/
Reset
scale
1. Turn on height measuring rod are ready by pressing the
ON/OFF key.
2. Push right caliper gauge till to the stop.
3. If the visual display deviates from “35.0 cm“, press the RESET
KEY
. The visual display will be reset to “35.0 cm“.
Switching Off Ö Press ON/OFF button, the display disappears.
MSA_80-BA-e-0910 11
Length
measuring
1. With KERN MBB
Ö Turn on the device and reset the scale, see chapter “How to
turn on / reset the scale“.
Ö Put the baby into the weighing pan. The head has to touch
gently the head stop.
Ö Shift caliper gauge acc. to fig. till the heel stop.
Ö Read the body height at the visual display or the measuring
rod.
12 MSA_80-BA-e-0910
2. Without KERN MBB
Ö Turn on the device and reset the scale, see chapter “How to
turn on / reset the scale“.
Ö Lay down the baby in a way that the head touches gently the
head stop.
Ö Shift caliper gauge acc. to fig. till the heel stop. Read the
body height at the visual display or the measuring rod.
HOLD function
Ö The measured value can be retained on the display by
pressing the
HOLD-key; pressing it again will make it
disappear.
Switching
between units
Ö To switch between the available units, press the UNIT-key.
cm ft/inch inch cm
MSA_80-BA-e-0910 13
14 MSA_80-BA-e-0910
9 Cleaning, Maintenance, Disposal
Cleaning
Do not use aggressive detergents (solvents etc.). Use a moist cloth dipped in soft soap suds or a household cleaner. Prevent liquids from entering the display unit.
Service,
maintenance
The appliance may only be opened by trained service technicians who are authorized by KERN.
Disposal
Disposal of packaging and appliance must be carried out by operator according to valid national or regional law of the location where the appliance is used.
Loading...