KERN MPU 250K100 Operating Instructions Manual

KERN & Sohn GmbH
Ziegelei 1 D-72336 Balingen email: info@kern-sohn.com
Phone: +49-[0]7433- 9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com
Operating instructions Personal scales
KERN MPU
Version 1.1 01/2010 GB
MPU-BA-e-1011
GB
KERN MPU
Version 1.1 01/2010
Operating instructions for personal scales
Table of Contents
1 Technical Data ............................................................................................... 3
2 Appliance overview ....................................................................................... 4
3 Basic Information (General).......................................................................... 5
4 Basic Safety Precautions.............................................................................. 7
5 Transportation & Storage.............................................................................. 7
6 Unpacking, Setup and Commissioning ....................................................... 8
6.1 Installation............................................................................................................................... 10
7 Operation...................................................................................................... 12
8 Adjustment................................................................................................... 15
9 BMI trend display......................................................................................... 20
10 Data output................................................................................................... 21
11 Printer mode................................................................................................. 22
11.1 Printout example .................................................................................................................... 22
11.2 Setting automatic printed edition......................................................................................... 22
11.3 Setting manual data output................................................................................................... 24
12 Error messages............................................................................................ 25
13 Service, maintenance, disposal.................................................................. 26
14 Instant help................................................................................................... 27
MPU-BA-e-0911 2
3 MPU-BA-e-0911
1 Technical Data
KERN MPU 250K100
Readability (d) 100 g Weighing range (max) 250 kg Reproducibility 200 g Linearity 200 g Weighing Units kg Adjustment weight 200 kg Height measurement (cm) 80 – 220 Height measurement tolerance ± 1 cm
Supply voltage: 220V – 240 V AC 50 Hz
Electric Supply
Secondary voltage powerpack: 12 V 500 mA Operating temperature + 5°C … + 35°C Humidity of air max. 80 % (not condensing) Dimensions fully mounted (W x
D x H) mm
380 x 525 x 2400
Weighing surface 380 x 370 x 80 Weight kg (net) 15
2 Appliance overview
(For assembly see Section 7.1)
2
3
1
6
4
7
7
5
5
7
7
1. Ultrasonic sensor
2. Display
3. Keyboard (only for servicing purposes)
4. Connections
5. Rollers
6. Weighing plate
7. Adjustable feet
MPU-BA-e-0911 4
5 MPU-BA-e-0911
3 Basic Information (General)
Intended use
These balance is used to calculate the weight of people standing upright in the private sphere. Utilisation of this balance in the medical field is not permissible.
The person must step on the weighing plate for the weighing procedure. As soon as a stable weighing value is reached the weighing value can be read.
Non-intended
use
Do not use balance for dynamic weighing. In the event that small quantities are removed or added to the material to be weighed, incorrect weighing results can be displayed due to the “stability compensation“ in the balance. (Example: Slowly draining fluids from a container on the balance.) Do not leave permanent load on the weighing plate. This may damage the measuring system. Impacts and overloading exceeding the stated maximum load (max) of the balance, minus a possibly existing tare load, must be strictly avoided. This could cause damage to the balance. Never operate balance in explosive environment. The serial version is not explosion protected. The structure of the balance may not be modified. This may lead to incorrect weighing results, safety-related faults and destruction of the balance.
The balance may only be used according to the described conditions. Other areas of use must be released by KERN in writing.
MPU-BA-e-0911 6
Warranty
Warranty claims shall be voided in case
Our conditions in the operation manual are ignored The appliance is used outside the described uses The appliance is modified or opened Mechanical damage and damage caused by media, liquids Natural wear and tear The appliance is improperly set up or incorrectly electrically
connected
The measuring system is overloaded Dropping the balance
Test device
control
In the framework of quality assurance the measuring-related properties of the balance and, if applicable, the testing weight, must be checked regularly. The responsible user must define a suitable interval as well as type and scope of this test. Information is available on KERN’s home page (www.kern­sohn.com) with regard to the monitoring of balance test substances and the test weights required for this. In KERN’s accredited DKD calibration laboratory test weights and balances may be calibrated (return to the national standard) fast and at moderate cost.
4 Basic Safety Precautions
Carefully read this operation manual before setup and commissioning, even if you are already familiar with KERN balances.
5 Transportation & Storage
Testing upon
acceptance
When receiving the appliance, please check packaging immediately, and the appliance itself when unpacking for possible visible damage.
Packing/
Return
transport
Ö Keep all parts of the original packaging for a possibly
required return.
Ö Only use original packaging for returning. Ö Prior to dispatch disconnect all cables and remove
loose/mobile parts.
Ö Secure all parts e.g. powerpack against slipping and
damage
7 MPU-BA-e-0911
MPU-BA-e-0911 8
6 Unpacking, Setup and Commissioning
Installation
location,
Deployment
location
The balance is designed in a way that reliable weighing results are achieved in common conditions of use. You will work accurately and fast, if you select the right location for your balance.
On the installation site observe the following:
Place scales on a stable, even surface Maintain a gap of 30 cm on all sides away from walls and
other objects or obstacles.
Avoid extreme heat as well as temperature fluctuation
caused by installing next to a radiator or in the direct sunlight;
Protect the balance against direct draughts due to open
windows and doors;
Avoid jarring during weighing; Protect the balance against high humidity, vapors and
dust;
Do not expose the device to extreme dampness for longer
periods of time. Non-permitted condensation (condensation of air humidity on the appliance) may occur if a cold appliance is taken to a considerably warmer environment. In this case, acclimatize the disconnected appliance for ca. 2 hours at room temperature.
Avoid static charge of the balance and of the person to be
weighed.
Avoid contact with water.
If electro-magnetic fields or static charge occur, or if the power supply is unstable major deviations on the display (incorrect weighing results) are possible. In that case, the location must be changed.
Unpacking
Remove the individual components of the balance or the complete balance from the packaging with care and install at the intended location.
Scope of supply
Scales (The top unit is packed and delivered separately from the bottom unit, see Fig. 1)
Screws
Interface cable
Operating instructions
Fig. 1
1. Top unit
2. Bottom unit
Placing
The assembled scales are 2.40 m high.
Maintain a gap of 30 cm on all sides away from walls and
other objects or obstacles.