KERN KFB-TM, KFN-TM Service Manual

KERN & Sohn GmbH
Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com
Servicemanual Display Unit
KERN KFB/KFN-TM
Version 1.0
03/2018 GB
Distributør: Impex Produkter AS Gamle Drammensvei 107 1363 Høvik www.impex.no info@impex.no Tel.: 22 32 77 20
KFB-TM/KFN-TM-SH-e-1410 - 2 -
GB
KERN KFB/KFN-TM
Version 1.0 01/2015
Servicemanual
Content
1 Basic Information ........................................................................................... - 3 -
2 Introdution ...................................................................................................... - 3 -
3 INSTALLATION ............................................................................................... - 4 -
3.1 Installation .............................................................................................................................. - 4 -
4 Appliance overview ........................................................................................ - 5 -
4.1 KFB-TM: Synthetic finish ...................................................................................................... - 5 -
4.2 KFN-TM: Stainless steel finish ............................................................................................. - 6 -
4.3 Keyboard overview ................................................................................................................ - 7 -
Numerical input via the navigation buttons ................................................................ - 8 -
Overview of display ..................................................................................................... - 8 -
5 Menu ................................................................................................................ - 9 -
5.1 Overview non verifiable weighing systems (contacts of circuit board [K1] not short-
circuited) ........................................................................................................................................... - 10 -
5.2 Overview verified weighing systems (contacts of circuit board [K1] short-circuited by
means of jumper) ............................................................................................................................. - 13 -
6 Service, maintenance, disposal .................................................................. - 17 -
6.1 Clean ..................................................................................................................................... - 17 -
6.2 Service, maintenance .......................................................................................................... - 17 -
6.3 Disposal ................................................................................................................................ - 17 -
6.4 Error messages.................................................................................................................... - 17 -
7 Data output RS 232C .................................................................................... - 19 -
7.1 Technical data ...................................................................................................................... - 19 -
7.2 Printer mode ......................................................................................................................... - 19 -
7.3 Output log (continuous output) ......................................................................................... - 20 -
7.4 Remote control instructions ............................................................................................... - 20 -
8 Instant help ................................................................................................... - 21 -
9 Installing display unit / weighing bridge .................................................... - 22 -
9.1 Technical data ...................................................................................................................... - 22 -
9.2 Weighing system design .................................................................................................... - 22 -
9.3 How to connect the platform .............................................................................................. - 23 -
9.4 Configure display unit ......................................................................................................... - 25 -
Verified weighing systems (contacts of circuit board [K1] short-circuited by means of
jumper) - 25 -
Non verifiable weighing systems (contacts of circuit board [K1] not short-circuited ) .... -
30 -
10 MAINTENENCE ......................................................................................... - 33 -
10.1 General ................................................................................................................................. - 34 -
- 3 - KFB-TM/KFN-TM-SH-e-1410
10.2 Error Codes .......................................................................................................................... - 34 -
10.3 Check the Load cell ............................................................................................................. - 35 -
10.4 Check Indicator Voltages .................................................................................................... - 35 -
AC Power ................................................................................................................... - 35 -
Adaptor Voltage ........................................................................................................ - 35 -
PCB Input Voltage ...................................................................................................... - 36 -
Check Battery Voltage and Charging Voltage ............................................................ - 36 -
10.5 Problems and Solutions ..................................................................................................... - 37 -
11 10. TROUBLE SHOOTING ........................................................................ - 39 -
11.1 No Power .............................................................................................................................. - 39 -
No Display ........................................................................................................................................ - 40 -
Battery not charging ....................................................................................................................... - 41 -
11.2 Not Weighing ........................................................................................................................ - 42 -
11.3 Unstable ................................................................................................................................ - 43 -
12 11. CIRCUIT DIAGRAM ............................................................................. - 44 -
13 DRAWING .................................................................................................. - 48 -
13.1 Drawing KFB-TM .................................................................................................................. - 48 -
13.2 Parts List .............................................................................................................................. - 49 -
13.3 Drawing KFN-TM .................................................................................................................. - 50 -
13.4 Parts List .............................................................................................................................. - 51 -
1 Basic Information
The device must be repaired only by trained specialist staff or personnel with professional formation (such as a repair-specialist accredited by law concerning verification). The service manual is obligatory for repair work. After repair, original conditions of the device have to be restored. Only original spare parts should be used.
Instructions about conformity-evaluated scales:
Repair must be carried only at 100% compliance with the type approval. A violation of this specification will result in a loss of the type approval! After successful repair the balance will have to be reverified before it can be used again in a statutorily regulated field.
Detailed instructions about conformity-evaluated scales:
Repair must be carried only at 100% compliance with the type approval. A violation of this specification will result in a loss of the type approval!
After successful repair the balance will have to be reverified before it can be used again in a statutorily regulated field.
2 Introdution
This service manual covers the EOA series and is edited for the authorized servicing personnel. Note all rights are reserved. Copying any part of this manual is prohibited without our permission.
KFB-TM/KFN-TM-SH-e-1410 - 4 -
In this lineup it is an eco product, Therefore, it is not intended to represent the repair manual in detail, since the construction of the balance is very simple. It is therefore only referring to the list of related to disposal spare parts.
3 INSTALLATION
Precautions
The weighing indicator is a precision electronic instrument, handle it
carefully.
Do not install the scale in direct sunlight.  Verify the local voltage and receptacle type are correct for
the scale.
Only use original adaptor, other could cause damage to the scale.  Pluggable equipment must be installed near an easily accessible
socket outlet.
Avoid unstable power sources. Do not use near large users of
electricity such as welding equipment or large motors.
Avoid sudden temperature changes, vibration, wind and water.  Avoid heavy RF noise.  Keep the indicator clean.
3.1 Installation
Place the Indicator on a table or connect with proper stand. Connect the plat form load cell cable in to the indicator load cell connecter. Load cell
connecter is locating back side of the indicator.
Connect the adaptor pin in to the indicator adaptor jack.
Adaptor jack is locating, back side of the indicator.
Adaptor connects into your AC power socket. Pluggable
equipment must be installed near an easily accessible socket outlet with a protective ground/ earth contact.
Turn on the On/Off key. If you want to turn off, press the key again. Display will be show the scale capacity and will be starting self checking. After self checking, display will be come to normal weighing mode. Warm-up time of 15 minutes stabilizes the measured values after switching on. Calibrate with exact calibration weights, minimum 1/3 of the scale capacity want to
use for calibration. For calibration see details in parameter.
- 5 - KFB-TM/KFN-TM-SH-e-1410
Then you can start your operation
4 Appliance overview
4.1 KFB-TM: Synthetic finish
1. Status of rechargeable battery
2. Keyboard
3. Weight display
4. Tolerance margin, see chap. 7.7
5. Weighing unit
6. RS-232
7. Input connection load cell cable
8. Guide rail support base / stand
9. End stop support base / stand
10. Mains adapter connection
KFB-TM/KFN-TM-SH-e-1410 - 6 -
11. Adjustment switch
4.2 KFN-TM: Stainless steel finish
1. Status of rechargeable battery
2. Keyboard
3. Weight display
4. For tolerance mark see chap. 7.7
5. Weighing unit
6. Input connection load cell cable
7. Mains adapter connection
- 7 - KFB-TM/KFN-TM-SH-e-1410
4.3 Keyboard overview
Key
Function
Turn on/off
Zeroing
Navigation button
Confirm entry
Taring
Navigation key
At numeric input increase flashing digit Scroll forward in menu
Display sum total
Navigation key
Digit selection to the right
Add weighing value to summation memory
Navigation key
Digit selection to the left
Calculate weighing data via interface
C
Delete
Change between gross and net weight
ESC
Back to menu/weighing mode
Call up animal weighing function
Call up weighing with tolerance range
Delete total added memory
KFB-TM/KFN-TM-SH-e-1410 - 8 -
Numerical input via the navigation buttons
Press and current setting will be displayed. The first digit will be flashing and is
ready for changing.
If you do not wish to change the first digit, press and the second digit will start
flashing. Each time you press , the display will move to the subsequent digit, after the last
digit the display will return to the first digit.
To change the selected (flashing) digit, press repeatedly until the desired value is
displayed. Then press to access further digits and change them by .
Complete your entry by .
Overview of display
Display
Significance
Battery very low
STABLE
Stability display
ZERO
Zero indicator
GROSS
Gross weight
NET
Net weight
AUTO
Automatic add-up enabled
Kg
Weighing unit
M+
Totalisation
LED
+ / / -
Indicators for weighing with tolerance range
- 9 - KFB-TM/KFN-TM-SH-e-1410
5 Menu
The application of the display unit as a verified weighing system requires that you short­circuit the two contacts [K1] of the circuit board, using a jumper. To that effect, a menu for verified weighing systems is available. For menu layout see chap. 8.2. There is no jumper for weighing systems that cannot be verified. To that effect, a menu is available for weighing systems that cannot be verified, Menu layout
see chap. 8.1
Navigation in the menu:
Call up menu
Switch-on balance and during the selftest press .
Press , , subsequently, the first menu block
„PO CHK“ will be displayed.
Select menu block
With help of , the individual menu items can be selected
one after the other.
Select setting
Confirm selected menu item by pressing . The current
setting will be displayed.
Change settings
To change to the available settings, press the navigations
keys as described in chap. 2.1.
Acknowledge setting / exit the menu
Either save by pressing or cancel by pressing .
Return to weighing mode
Press repeatedly to exit menu.
KFB-TM/KFN-TM-SH-e-1410 - 10 -
5.1 Overview non verifiable weighing systems (contacts of circuit board [K1] not short-circuited)
Menu block Main menu
Menu item Submenu
Available settings / explanation
PO CHK
Weighing with tolerance range, see chap. 7.7
nEt H
Upper limit value „Tolerance check weighing“, input see
chap. 7.7.1
nEt LO
Lower limit value „Tolerance check weighing“, input see
chap. 7.7.1
PCS H
Upper limit value „Tolerance check counting“, input see
chap. 7.7.2
PCS L
Lower limit value „Tolerance check counting“, input see
chap. 7.7.2
BEEP
no
Acoustic signal for weighing with tolerance range switched off
ok
Audio sound when load is within tolerance limits
nG
Audio sound when load is beyond tolerance limits
P1 REF
Zero point settings
A2n0
Automatic zero point correction (Autozero) by changing the display, digits selectable (0.5d, 1d, 2d, 4d)
0AUto
Zero setting range Load range where the display after switching-on the balance is set to zero.
Selectable 0, 2, 5, 10, 20, 30, 50, 100 %
0rAGE
Zero setting range Load range where the display is set to zero by pressing
. Selectable 0, 2, 4, 10 , 20* , 50, 100%.
0tArE
Automatic taring „on / off“, taring range adjustable in menu
item „0Auto“.
SPEEd
Not documented
Zero
Zero point setting
P2 COM
Interface parameter
MODE
CONT S0 off
Continuous data output, selectable “send zero” yes / no
S0 on
ST1
One output for stable weighing value
STC
Continuous data output of stable weighing values
PR1 Output after pressing
- 11 - KFB-TM/KFN-TM-SH-e-1410
PR2
Manual totalizing, see chap. 7.8.
Press and the weighing value will be added to the summation memory and issued.
AUTO*
For automatic add-up see chap. 7.9.
This function is used to issue and add individual weighing values automatically to the summation memory on unloading of weighing scale.
ASK
For remote control commands, see chap. 10.4
wirel
Not documented
BAUD
Available Baudrate: 600, 1200, 2400, 4800, 9600*
Pr
7E1
7 bits, even parity
7o1
7 bits, odd parity
8n1*
8 bits, no parity
PTYPE tPUP*
Standard printer setting
LP50
Not documented
Lab
Lab x
For data output format, see chap.8.2, tab. 1 Prt
Prt x
LAnG
eng*
Standard settings English
chn
P3 CAL
Configuration data see chap. 12.4
COUNT
Display internal resolution
DECI
Position of the decimal dot
DUAL
Setting balance type, capacity (Max) and readability (d)
off
Single-range balance
R1 inc
Readability
R1 cap
Capacity
on
Dual range balance
R1 inc
Readability 1st weighing range
R1 cap
Capacity 1st weighing range
KFB-TM/KFN-TM-SH-e-1410 - 12 -
R2 inc
Readability 2nd weighing range
R2 cap
Capacity 2nd weighing range
CAL
noLin
For adjustment, see chap. 6.9.2
Liner
For linearization, see chap. 6.10.2
GrA
Not documented
P4 OTH
LOCK on
Keyboard lock enabled, see chap. 7.11
off*
Keyboard lock disabled
ANM on
Animal weighing enabled, see chap. 7.10
off*
Animal weighing disabled
P5 Unt
Switch-over weighing unit, see chap. 7.5
kg on* off
g on off*
lb on
off*
oz on
off*
tJ on
off
HJ on off
P6 xcl
Not documented
P7 rst Use to reset balance settings to factory default.
P8 uwb
Not documented
Factory settings are marked by *.
- 13 - KFB-TM/KFN-TM-SH-e-1410
5.2 Overview verified weighing systems (contacts of circuit board [K1] short-circuited by means of jumper)
In verified weighing systems the access to „P2 mode and „P4 tAr“ is locked.
KERN KFB-TM:
To disable the access lock, destroy the seal and actuate the adjustment switch. Position of the adjustment switch see chap. 6.11.
KERN KFN-TM: In order to unlock the access, the seal must be destroyed and both contacts of the
printed circuit board [K2] must be short-circuited by a jumper, see chap. 6.11. Attention:
After destruction of the seal the weighing system must be re-verified by an authorised agency and a new verification wire/seal mark fitted before it can be reused for applications subject to verification.
Menu block Main menu
Menu item Submenu
Available settings / explanation
PO CHK Weighing with
tolerance range, see chap. 7.7
nEt H
Upper limit value „Tolerance check weighing“, input see
chap. 7.7.1
nEt LO
Lower limit value „Tolerance check weighing“, input see
chap. 7.7.1
PCS H
Upper limit value „Tolerance check counting“, input see
chap. 7.7.2
PCS L
Lower limit value „Tolerance check counting“, input see
chap. 7.7.2
BEEP
no
Acoustic signal for weighing with tolerance range switched off
ok
Audio sound when load is within tolerance limits
ng
Audio sound when load is beyond tolerance limits
P1 COM
Interface parameter
MODE
CONT S0 off
Continuous data output, selectable “send zero” yes / no
S0 on
ST1
One output for stable weighing value
STC
Continuous data output of stable weighing values
KFB-TM/KFN-TM-SH-e-1410 - 14 -
PR1 Output after pressing
PR2
Manual totalizing, see chap. Fehler!
Verweisquelle konnte nicht gefunden werden.
Press and the weighing value will be added to the summation memory and issued.
AUTO
For automatic totalizing see chap. Fehler!
Verweisquelle konnte nicht gefunden werden.
This function is used to issue and add individual weighing values automatically to the summation memory on unloading of weighing scale.
ASK
For remote control commands, see chap. 7.4
wireless
Not documented
baud
Available Baudrate: 600, 1200, 2400, 4800, 9600
Pr
7E1
7 bits, even parity
7o1
7 bits, odd parity
8n1
8 bits, no parity
PtYPE tPUP
Standard printer setting
LP50
Not documented
Lab
Lab x
Details see following table 1 Prt
Prt x
Lang Eng*
Standard setting English Chn
P2 mode
Konfigurations­daten
SiGr
Single-range balance
COUNT
Display internal resolution
DECI
Position of the decimal dot
Div.
Readability [d] / verification value[s]
CAP
Balance capacity [Max]
- 15 - KFB-TM/KFN-TM-SH-e-1410
CAL
noLin
Adjustment, see chap. Fehler!
Verweisquelle konnte nicht gefunden werden.
LinEr
Linearisation, see chap. Fehler!
Verweisquelle konnte nicht gefunden werden.
GrA
Not documented
dUAL 1
Dual range balance
Balance with two weighing ranges and different maximum load and weighing ranges and interval sizes but only one load­supporting pan, whereby each range extends from zero to the respective maximum capacity. When load is removed, weighing scales will remain in 2nd range.
COUNT
Display internal resolution
DECI
Position of the decimal dot
div. div 1
Readability [d] / verification value [e]
1. weighing range
div 2
Readability [d] / verification value [e]
2. weighing range
CAP CAP 1
Weighing scale capacity [max]
1. Weighing range
CAP 2
Weighing scale capacity [max]
2. Weighing range
CAL
noLin
Adjustment, see chap. 6.9
LinEr
For linearization, see chap. Fehler!
Verweisquelle konnte nicht gefunden werden.
GrA
Not documented
dUAL 2
Multi-interval balance
Weighing scales with one weighing range subdivided into partial weighing ranges, each providing a different scale interval. The scale interval depends on the applied load and is automatically changed during loading and unloading.
COUNT
Display internal resolution
DECI
Position of the decimal dot
div.
div 1
Readability [d] / verification value [e]
1. weighing range
KFB-TM/KFN-TM-SH-e-1410 - 16 -
div 2
Readability [d] / verification value [e]
2. weighing range
CAP CAP 1
Weighing scale capacity [max]
1. Weighing range
CAP 2
Weighing scale capacity [max]
2. Weighing range
CAL
noLin
Adjustment, see chap. Fehler!
Verweisquelle konnte nicht gefunden werden.
LinEr
Linearisation, see chap. Fehler!
Verweisquelle konnte nicht gefunden werden.
GrA
Not documented
P3 OTH s. Kap. 7.10 / 7.11
LOCK
on
Keyboard lock enabled
off
Keyboard lock disabled
ANM
on
Animal weighing enabled
off
Animal weighing disabled
P4 tAr Restricted taring
range
Press , the current setting will be displayed. Using the navigation buttons (see chap. 2.1.1) select the desired setting, the active digit is flashing.
Confirm input by .
P5 St Follow up tare
St on
Follow up tare switched on
St off
Follow up tare switched off
P6 SP
7.5, 15, 30
Not documented
Tab. 1. Printout examples Standard printer
Lab
Prt
0 1 2
3
0~3
******************* GS: 5.000kg
******************* NT: 5.000kg
********************** GS: 5.000kg
********************** NT: 5.000kg
- 17 - KFB-TM/KFN-TM-SH-e-1410
*******************
TW: 5.000kg GW: 10.000kg *******************
TOTAL: 10.000kg **********************
TW: 5.000kg GW: 10.000kg TOTAL: 10.000kg **********************
4~7
******************* No.: 1 GS: 5.000kg *******************
******************* No.: 1 NT: 5.000kg TW: 5.000kg GW: 10.000kg *******************
********************** No.: 1 GS: 5.000kg TOTAL: 10.000kg **********************
********************** No.: 1 NT: 5.000kg TW: 5.000kg GW: 10.000kg TOTAL: 10.000kg **********************
GS / GW
Gross weight
NO
Number weighing processes
NT
Net weight
TOTAL
Total of all individual weighings
TW
Tare weight
6 Service, maintenance, disposal
6.1 Clean
Before cleaning, disconnect the appliance from the operating voltage. Do not use aggressive detergents (solvents or similar).
6.2 Service, maintenance
The appliance may only be opened by trained service technicians who are authorized by KERN.
Before opening, disconnect from power supply.
6.3 Disposal
Disposal of packaging and appliance must be carried out by operator according to valid national or regional law of the location where the appliance is used.
6.4 Error messages
Error
message
Description
Possible causes
- - - - -
Maximum load exceeded
Unload weighing system or reduce
KFB-TM/KFN-TM-SH-e-1410 - 18 -
- - ol - -
preload.
Err 1
Incorrect data input
Follow format “yy:mm:dd“
Err 2
Incorrect time entry
Follow format “hh:mm:ss“
Err 4
Zeroing range exceeded due to switching-on balance or pressing
(normally 4% max)
Object on the weighing plateOverload when zeroing
Err 5
Keyboard error
Err 6
Value outside the A/D changer range
Weighing plate not installed
Damaged weighing cell
Damaged electronics
Err 9
Stability display does not appear
Check the environmental conditions.
Err 10
Communication error
No data
Err 15
Gravitation error
Range 0.9 ~ 1.0
Err 17
Taring range exceeded
Reduce load
Fai l h / Fai l l
Adjustment error
Repeat adjustment.
Err P
Printer error
Check communication parameters
Ba lo / Lo ba
Battery very low
Recharge battery
Should other error messages occur, switch balance off and then on again. If the error message remains inform manufacturer.
- 19 - KFB-TM/KFN-TM-SH-e-1410
7 Data output RS 232C
You can print weighing data automatically via the RS 232C interface or manually by pressing
via the interface according to the setting in the menu.
This data exchange is asynchronous using ASCII - Code.
The following conditions must be met to provide successful communication between the weighing system and the printer.
Use a suitable cable to connect the display unit to the interface of the printer.
Faultless operation requires an adequate KERN interface cable.
Communication parameters (baud rate, bits and parity) of display unit and printer
must match. For a detailed description of interface parameters see chap. Fehler!
Verweisquelle konnte nicht gefunden werden., menu block „P1 COM“ or ‚“P2 COM“
7.1 Technical data
Connection
9 pin d-subminiature bushing
Pin 2 input Pin 3 output Pin 5 signal earth
Baud rate
Optional 600/1200/2400/4800/9600
Parity
8 bits, no parity / 7 bits, even parity / 7 bits, odd parity
7.2 Printer mode
Printout examples (KERN YKB-01N):
Weighing
ST, GS 1.000kg
KFB-TM/KFN-TM-SH-e-1410 - 20 -
Symbols:
ST
Stable value
US
Instable value
GS / GW
Gross weight
NT
Net weight
TW
Tare weight
NO
Number weighing processes
TOTAL
Total of all individual weighings
<lf>
Space line
<lf>
Space line
Counting
7.3 Output log (continuous output)
Weighing
HEADER1: ST=STABLE US=UNSTABLE
HEADER2: NT=NET GS=GROSS
7.4 Remote control instructions
Command
Function
Printout examples
****************************
PCS 100
- 21 - KFB-TM/KFN-TM-SH-e-1410
S
Stable weighing value for the weight is sent via the RS232 interface
ST,GS 1.000KG
W
Weighing value for the weight (stable or unstable) is sent via the RS232 interface
US,GS 1.342KG ST,GS 1.000KG
T
No data are sent, the balance carries out the tare function.
-
Z
No data are sent, the zero-display appears.
-
P
Quantity will be sent via the RS232-interface
10PCS
8 Instant help
In case of an error in the program process, briefly turn off the display unit and disconnect from power supply. The weighing process must then be restarted from the
beginning.
Help:
Fault
Possible cause
The displayed weight does not glow.
The display unit is not switched on.
Mains power supply interrupted (mains cable defective).
Power supply interrupted.
(Rechargeable) batteries are inserted incorrectly or
empty
No (rechargeable) batteries inserted.
The displayed weight is permanently changing
Draught/air movement
Table/floor vibrations
Weighing pan has contact with other objects. Electromagnetic fields / static charging (choose different
location/switch off interfering device if possible)
The weighing result is obviously incorrect
The display of the balance is not at zero
Adjustment is no longer correct.
KFB-TM/KFN-TM-SH-e-1410 - 22 -
Great fluctuations in temperature.
Warm-up time was ignored.
Electromagnetic fields / static charging (choose different
location/switch off interfering device if possible)
Should other error messages occur, switch display unit off and then on again. If the error message remains inform manufacturer.
9 Installing display unit / weighing bridge
Installation / configuration of a weighing system must be carried out
by a well acquainted specialist with the workings of weighing balances.
9.1 Technical data
Supply voltage:
5 V/150mA
Max. signal voltage
0-10 mV
Zeroing range
0-2 mV
Sensitivity
2-3 mV/V
Resistance parameter
80 - 100 Ω, max 4 items per 350 Ω load cell
9.2 Weighing system design
The display unit is suitable for connection to any analogue platform in compliance with the required specifications.
The following data must be established before selecting a weighing cell:
Weighing balance capacity
This usually corresponds to the heaviest load to be weighed.
Preload
This corresponds to the total weight of all parts that are to be placed on the weighing cell such as upper part of platform, weighing pan etc.
Total zero setting range
This is composed of the start-up zero setting range (± 2%) and the zero setting range available to the user via the ZERO-key (2%). The total zero setting range equals therefore 4 % of the scale’s capacity.
The addition of weighing scales capacity, preload and the total zero setting range give the required capacity for the weighing cell. To avoid overloading of the weighing cell, include an additional safety margin.
- 23 - KFB-TM/KFN-TM-SH-e-1410
Smallest desired display division Verifiability, if required
The application of the display unit as a verified weighing system requires that you short-circuit the two contacts [K1] of the circuit board, using a jumper; for position see chap. Fehler! Verweisquelle konnte nicht gefunden werden.. Remove the jumper for weighing systems not able to be verified.
9.3 How to connect the platform
Disconnect the display unit from the power supply. Solder the individual leads of the load cell cable onto the circuit board. See diagrams
below.
EXC+
SEN+
SEN-
EXC­SIG+
SIG-
SHIELD
7
6
3
2
LOAD CELL
KFB-TM/KFN-TM-SH-e-1410 - 24 -
PIN
Loadcell
6- conductor
4- conductor
7
EXC+
EXC+
6
SEN+
5
EXC-
EXC-
4
SEN-
3
SHIELD
SHIELD
2
SIG-
SIG-
1
SIG+
SIG+
- 25 - KFB-TM/KFN-TM-SH-e-1410
9.4 Configure display unit
Verified weighing systems
(contacts of circuit board [K1] short-circuited by means of jumper)
For menu overview see chap. 5.2. In verified weighing systems the menu item for calibration „P2 mode“ is blocked.
KERN KFB-TM:
To disable the access lock, destroy the seal and actuate the adjustment switch. Position of the adjustment switch see chap. Fehler! Verweisquelle konnte nicht
gefunden werden. KERN KFN-TM:
To override the blocked access you will have to destroy the seal before calling up the menu and to short-circuit the two contacts on the circuit board [K2], using a jumper (See chap. Fehler! Verweisquelle konnte nicht gefunden werden.).
Attention: After destruction of the seal the weighing system must be re-verified by an authorised agency and a new verification wire/seal mark fitted before it can be reused for applications subject to verification.
Call up menu:
Switch-on balance and during the selftest press .
Press , , subsequently, the first menu block „PO
CHK“ will be displayed.
Press repeatedly until „P2 mode“ will be displayed. Operate the adjustment switch (models KFB-TM).
Press and use to select the weighing scales type.
Single-range balance
Dual range balance Multi-interval balance
KFB-TM/KFN-TM-SH-e-1410 - 26 -
Example single range scales (d = 10 g, max. 30 kg)
Confirm selected weighing scales type by pressing ; the first
menu item „COUNT“ will be shown.
1. Display internal resolution
Press , the internal resolution will be shown.
Return to menu by .
Press to select the next menu item.
2. Position decimal point
Press , the currently set position of the decimal dot is
displayed.
Press to select the desired setting.
Options 0, 0.0, 0.00, 0.000, 0.0000.
Confirm input by .
Press to select the next menu item.
3. Readability
Press and current setting will be displayed.
Select desired setting by . Options 1, 2, 5, 10, 20, 50.
Confirm entry by .
Press to select the next menu item.
- 27 - KFB-TM/KFN-TM-SH-e-1410
4. Capacity
Press , the current setting will be displayed.
Using the navigation buttons (see chap. 2.1.1) select the desired setting, the active digit is flashing.
Confirm input by .
Press to select the next menu item.
5. Adjustment / linearization Adjustment or linearization is required after entering configuration data. For carrying out adjustment see chap. Fehler! Verweisquelle
konnte nicht gefunden werden./step 6 or chap. Fehler! Verweisquelle konnte nicht gefunden werden. for linearisation
Example dual range scales (d = 2 / 5 g, max. 6 / 15 kg)
Confirm selected weighing scales type by ; the first menu
item „COUNT“ will be shown.
1. Display internal resolution
Press , the internal resolution will be shown.
Return to menu by .
Press to select the next menu item.
2. Position decimal point
Press , the currently set position of the decimal dot is
displayed.
Use to select the desired setting.
Options 0, 0.0, 0.00, 0.000, 0.0000.
Confirm input by .
KFB-TM/KFN-TM-SH-e-1410 - 28 -
Press to select the next menu item.
3. Readability
Press , the display used to enter readability/verification value
for first weighing range will appear.
Press , the current setting will be displayed.
Select desired setting with and acknowledge by .
Press to enter the next menu item for readability/verification
value for second weighing range.
Press and current setting will be displayed.
Select desired setting with and acknowledge by .
Press , the unit will return to the menu
Press to select the next menu item.
- 29 - KFB-TM/KFN-TM-SH-e-1410
4. Capacity
Press and the display for entering the capacity for the first
weighing range will appear.
Press and current setting will be displayed.
Select desired setting with and acknowledge by .
Press to select the next menu item used to enter the
capacity for the second weighing range.
Press and current setting will be displayed.
Select desired setting with and acknowledge by .
Press , the unit will return to the menu
Use toselect next menu item.
5. Adjustment / linearization Adjustment or linearization is required after entering configuration data. For carrying out adjustment see chap. Fehler! Verweisquelle
konnte nicht gefunden werden./step 6 or chap. Fehler! Verweisquelle konnte nicht gefunden werden. for linearisation
Acknowledge using , the current setting is displayed. Acknowledge by , select desired setting with
= Adjustment
= Linearisation
KFB-TM/KFN-TM-SH-e-1410 - 30 -
Non verifiable weighing systems
(contacts of circuit board [K1] not short-circuited )
+ For menu overview see chap. 5.1.
Call up menu
Switch-on balance and during the selftest press .
Press , , subsequently , the first menu block „PO
CHK“ will be displayed.
Press repeatedly until „CAL“ will be displayed.
Press , the first menu item „COUNT“ will be displayed.
Navigation in the menu
With help of , the individual menu items can be selected
one after the other.
Confirm selected menu item by pressing . The current
setting will be displayed.
To change to the available settings, press the navigations keys as
described in chap. 2.1.1.
Either save by pressing or cancel by pressing . Press repeatedly to exit menu.
Parameter selection
1. Display internal resolution
Press , the internal resolution will be shown.
Return to menu by .
Use to select another menu item.
2. Position decimal point
- 31 - KFB-TM/KFN-TM-SH-e-1410
Press , the currently set position of the decimal dot is
displayed.
To make changes using the navigation keys (See chap. 2.1.1), select the desired setting. Options 0, 0.0, 0.00, 0.000, 0.0000.
Confirm input by .
Use to select another menu item.
3. Weighing scales type, capacity and readability
Press and current setting will be displayed.
Select desired setting by .
„off“ Single-range balance „on“ Dual range balance
Press to confirm, the display for entering readability (for dual
range scales for the first weighing range) appears.
Press , the current setting will be displayed.
Select desired setting with and acknowledge by .
Press , the display for entering capacity will appear (at dual
range balance for the first range).
Press , the current setting will be shown (such as max. =
2000kg).
Using the navigation buttons (see chap. 2.1.1) select the desired
setting, the active digit is flashing.
Acknowledge with .
In a single-range balance the entry of capacity / readability is
KFB-TM/KFN-TM-SH-e-1410 - 32 -
finished.
either in single-range balance
Press , the unit will return to the menu Press to call up
next menu item „CAL“.
or
In a dual range balance enter readability/verification value and capacity of the second weighing range.
Press , the display for entering the capacity of the second
weighing range will appear.
Press , the current setting will be displayed. Using the navigation buttons (see chap. 2.1.1) select the desired
setting, the active digit is flashing.
Confirm input by .
Press , the display for entering the readability of the second
weighing range will appear.
Press , the current setting will be displayed.
Select desired setting with and acknowledge by .
Press , the unit will return to the menu
Press to call next menu item.
4. Adjustment or linearisation Adjustment or linearisation is required after entering configuration data. For carrying out adjustment see chap. Fehler! Verweisquelle
konnte nicht gefunden werden./step 4 or chap. Fehler! Verweisquelle konnte nicht gefunden werden. for linearisation
Acknowledge using , the current setting is displayed. Press to confirm, press to select the desired setting
- 33 - KFB-TM/KFN-TM-SH-e-1410
noLin = Adjustment LineAr = Linearisation
10 MAINTENENCE
WARNING
DISCONNECT ALL POWER TO THIS UNIT BEFORE INSTALLING, CLEANING, OR SERVICING. FAILURE TO DO SO COULD RESULT IN BODILY HARM OR DAMAGE THE UNIT.
CAUTION
Permit only qualified persons to service the instrument Before connecting or disconnecting any components, remove the power. Failure to observe these precautions bodily harm or damage to or
destruction of the equipment.
KFB-TM/KFN-TM-SH-e-1410 - 34 -
10.1 General
If the scale does not operate properly, find out the problem as possible. Determine whether the problem is constant or alternate. Be aware that problems can be
caused by mechanical or electrical influences.
Check the following.
Water Corrosive materials Vibrations or temperature or wind Physical damage
Check the indicator cables for damage, and check all connections and connecters for any
loose contact or incorrect connection
10.2 Error Codes
Indicator’s error message’s following lists
ERROR CODES
DESCRIPTION
RESOLUTION
-----
Over load
Weight on the scale exceeds calibrated capacity. Decrease load on the scale.
If the problem persists re calibrate the scale
Err 4
Scale not zeroed at power up
Auto Zero on power up is exceeded due to switching on.(4%max)
Zero the scale or remove the weight. Re calibrate the scale.
Err 6
A/D out of range
The values of the A/D converter are outside from the normal range. Remove the weight from the scale if overloaded and make sure the pan is attached.
Load cell or the electronics may be faulty.
9.3. Determine the Problem
- 35 - KFB-TM/KFN-TM-SH-e-1410
Determine whether the problem is in the indicator or the platform
Remove power from the system, and disconnect the indicator from the platform Connect the indicator to a load cell simulator Reapply power and test the indicator If problem goes away, its source is probably in the platform. Check the wiring,
connecter, load cells and mechanical components of the platform. If problem persists, its source is probably in the indicator. Check the indicator
voltages, connecters, cables and function programs.
10.3 Check the Load cell
Remove power from the system, and disconnect the indicator from the platform Remove the load connecter from platform terminal. Check the moisture, or foreign material inside. Make sure all leads are connected and correctly. See the details of connections in the
Installation section.
Check load cell for proper input and output resistances
Measuring Points
Resistance
+ Exc to –Exc (Input)
Minimum 350 ohms
+Sig to –Sig (Output)
347 ~ 353 ohms
10.4 Check Indicator Voltages
If the problem is in the Indicator, use a multimeter to check the following voltages
AC Power
Check the AC power socket out put voltage.
Voltage must be a -20% and +10% of the normal AC voltage.
Adaptor Voltage
Check the adaptor output cable connecter voltage
Voltage must be minimum 9VDC and maximum 15VDC
KFB-TM/KFN-TM-SH-e-1410 - 36 -
PCB Input Voltage
Check the PCB input power connecter voltage
Voltage must be minimum 9VDC in to the pin AD+
Check Battery Voltage and Charging Voltage
1. Check the Battery Voltage,
Voltage must be minimum 6VDC. If below the 6VDC connect the adaptor for charging The battery voltage below the 5.5VDC, replace the battery and install new 6V/4Ah
battery.
2. Check the Battery Charging Voltage;
Remove the battery connection terminals (Red and Black) from the battery. Connect the power and turn on the Indicator Voltage into the terminal minimum 6.5VDC
- 37 - KFB-TM/KFN-TM-SH-e-1410
10.5 Problems and Solutions
Problems
Possible cause
Common Solutions
Display is blank. No self test
Mains power is turned off. Power supply faulty or not plugged. Internal battery is not charged. On/Off switch problem
Check power is getting inside the scale and on/off switch is working.
Verify the voltages, which is on the power labels.
Blank display after self test
Pan not installed. Unstable weight, load
cell damaged
Check the pans are installed correctly. Try to turning on again.
OL or -------
Maximum capacity exceeded. Load cell or mechanics damaged. Power supply faulty
Check the platform is installed correctly. Try to turn on the scale again. Do the calibration again
------- or NULL displayed
Weight is on the platform is below permissible limit. Pan not installed correctly.
Power supply faulty. Load cell or mechanism
faulty
Check the platform is installed correctly. Try to turn on the scale again.
Do the calibration again
Display is unstable
Goods touching somewhere. Air variation or any vibrations. Temperature changed . Load cell or connections faulty.
Power supply faulty
Check the scale is in acceptable location.
Check the connecters and load cell. Check the power supply and battery
Weight value incorrect
Calibration error. Platform of load cell
touching somewhere. Wrong weighing unit
Use accurate weight for to do the calibration
Check the pan and load cell is installed proper and touching.
Check the parameter settings.
KFB-TM/KFN-TM-SH-e-1410 - 38 -
Check the load cell and connecters
Can not use full capacity
Over load protection stoppers or transport locks are not removed.
Parameters are set incorrectly.
AD problem. Load cell or mechanism
damaged
Check the stoppers and locks under the platform.
Check the weighing unit and parameter settings.
Check the load cell.
Platform Corner Weight different
Over load protection stoppers or transport locks are not removed.
Load cell or mechanism damaged
Check the stoppers and locks under the platform.
Use accurate weight for to do the calibration
Check the load cell.
Battery not charging
Mains voltage problem Charging circuit problem Battery Problem
Check the mains and adaptor. Check the battery. Check the charging circuit
- 39 - KFB-TM/KFN-TM-SH-e-1410
11 10. TROUBLE SHOOTING
11.1 No Power
Not good
Ok
Not good
Ok Not good
Ok
Not good
Ok
Not good
Ok
START
Check power switch connector
Check Battery Voltage >6V
Check DU 4 pin 1 Out put 5V
CHK M/B DU3 pin 8 high level when power on and return to low
Replace power switch or connecter
Recharge the battery or Replace the battery
Check DU4 and around circuit
Check M/B DU3 and around circuit
Check ST (11.0592Mhz)
Check ST and around circuit
Check M/B DU1 and around circuit
KFB-TM/KFN-TM-SH-e-1410 - 40 -
No Display
Not good
Ok Not good
Ok
Not good
Ok
Not good
Ok
Not good
START
Check LCD break or loose contact
Check the cable from main board to display board
Check U3 pin 17 Out put 5V
Press key board beeper
Replace LCD or connect proper
Replace the cable or connect proper
Replace IC power problem
Check U1 and around circuit
Check ST and around circuit
Check U3 and LCD
- 41 - KFB-TM/KFN-TM-SH-e-1410
Battery not charging
Yes No Not good
Ok Not good
Ok
Not good
Ok
START
Check Battery Voltage < 5V
Check Adaptor out put 9.5 V. with out connect the scale
Check C1 +9 V
CHK M/B U5 pin2
Replace Battery
Check the adaptor or replace adaptor.
Check BR, C1, C2 and around circuit
Check M/B DU5 and around circuit
Check M/B D1, R1 and around circuit
KFB-TM/KFN-TM-SH-e-1410 - 42 -
11.2 Not Weighing
Yes Yes
Ok
Not good
Ok
Not good
Not Good
START
Check can show internal counts
Check M/B AU1 pin 15: 5V
Add load on pan,
CHK output between
M/B AU1 pin1 and pin2
signal change (mV)
Check load cell and around circuit
Do calibration
Check the load cell and input circuit
Check M/B AU1 and around circuit
Add load on the pan, check the counts increase
Check power circuit
- 43 - KFB-TM/KFN-TM-SH-e-1410
11.3 Unstable
Yes
No Yes
START
Check after warm up
Check load cell and bracket touching something
Humidity
Sole the touching problem
Check M/B AU1 and around circuit
KFB-TM/KFN-TM-SH-e-1410 - 44 -
12 11. CIRCUIT DIAGRAM
Power
Display
- 45 - KFB-TM/KFN-TM-SH-e-1410
CPU
KFB-TM/KFN-TM-SH-e-1410 - 46 -
- 47 - KFB-TM/KFN-TM-SH-e-1410
KFB-TM/KFN-TM-SH-e-1410 - 48 -
13 DRAWING
13.1 Drawing KFB-TM
- 49 - KFB-TM/KFN-TM-SH-e-1410
13.2 Parts List
No
Parts Name
Qty
Spec
1
Key Panel
1 2
Display Protection Plate
1
3
Front Cover
1
4
Main PCBA
1 5
Insulation Washer
9
6
Self Thread Screw
10
3x10
7
Washer
4
8
Battery bar
2 9
Battery
1
6V/1.2AH
10
Self Thread Screw
2
M3
11
Nut 3 M3, Hexagon
12
RS-232 port
1
13
D Connecter
1 14
Star (+) Screw
1
3Mx20
15
Branch pipe
1 16
Main Serial board
1
17
Interface Module
1
18
Back Cover
1
19
Air Connecter
1 20
Star (+) Screw
7
M4x16
KFB-TM/KFN-TM-SH-e-1410 - 50 -
13.3 Drawing KFN-TM
- 51 - KFB-TM/KFN-TM-SH-e-1410
13.4 Parts List
No
Parts
Qty
Spec
1
Key Panel
1 2
Front Cover
1
3
Display Protection Plate
1
4
Nut 6 M3*6
5
Main PCBA
1
6
Washer
6
8x3.1x1.5
7
Star (+) Self Thread screw
6
M3x8
8
Water Proof Rubber Bar
1 9
Star (+) Screw
2
M4x10
10
Washer
2
M4
11
Battery Clamp
1 12
Washer
6
M4
13
Star (+) Big head Screw
6
M4x12
14
Bracket
1
15
Bracket Screw
2 16
Water Proof Adaptor jack
1
17
Interface Module
1
18
Air connecter
1
5Pin
19
Plug
1 20
Rubber Spacer
3
21
Air Connecter
1
7Pin
22
Back Cover
1 23
Air Connecter Water Proof Nut
1
24
Battery
1
6V/4Ah
25
Nut 1 M3x6
26
Main Serial board
1
KFB-TM/KFN-TM-SH-e-1410 - 52 -
27
Spacer
1
28
Star (+) Screw
1
3Mx20
29
Micro Switch Cap
7
Loading...