Kern EMB 100-3, EMB 200-3, EMB 1000-2, EMB 2000-2, EMB 6000-1 User guide

GB
KERN EMB
Version 2.2 11/2005
Operating Instructions Electronic Balance
1 TECHNICAL DATA ................................................................................................................................ 15
2 DECLARATION OF CONFORMTY..................................................................................................... 16
3 FUNDAMENTAL INFORMATION (GENERAL) ............................................................................... 17
3.1
I
NTENDED USE
3.2
I
NAPPROPRIATE USE
3.3
G
UARANTEE
3.4
M
ONITORING THE TEST SUBSTANCES
4 FUNDAMENTAL SAFETY INFORMATION...................................................................................... 18
4.1
O
BSERVE THE INFORMATION IN THE OPERATING INSTRUCTIONS
4.2
S
TAFF TRAINING
5 TRANSPORT AND STORAGE.............................................................................................................. 18
5.1
A
CCEPTANCE CHECK
5.2
P
ACKAGING
6 UNPACKING, INSTALLATION AND COMMISSIONING............................................................... 19
.................................................................................................................................... 17
............................................................................................................................ 17
....................................................................................................................................... 17
.................................................................................................. 17
......................................................... 18
................................................................................................................................. 18
.......................................................................................................................... 18
........................................................................................................................................ 18
6.1
P
LACE OF INSTALLATION, PLACE OF USE
6.2
U
NPACKING
6.2.1 Installation.................................................................................................................................... 20
6.2.2 List of items supplied..................................................................................................................... 20
6.3
B
ATTERY OPERATION
6.4
M
AINS SUPPLY
6.5
I
NITIAL START-UP
6.6
A
DJUSTMENT
6.6.1 Adjusting ....................................................................................................................................... 21
6.7
U
NDERFLOOR WEIGHING
7 OPERATION............................................................................................................................................. 23
7.1
O
VERVIEW OF THE KEYPAD
7.2
O
PERATING INSTRUCTIONS
7.2.1 Weighing ....................................................................................................................................... 23
7.2.2 Taring............................................................................................................................................ 23
7.2.3 Units.............................................................................................................................................. 24
8 MAINTENANCE, UPKEEP, DISPOSAL .............................................................................................. 24
8.1
C
LEANING
8.2
M
AINTENANCE, UPKEEP
8.3
D
ISPOSAL
9 TROUBLESHOOTING............................................................................................................................ 25
........................................................................................................................................ 20
......................................................................................................................... 20
.................................................................................................................................... 20
............................................................................................................................... 20
...................................................................................................................................... 21
..................................................................................................................... 22
................................................................................................................ 23
................................................................................................................. 23
........................................................................................................................................... 24
...................................................................................................................... 24
............................................................................................................................................ 24
............................................................................................. 19
1 Technical data
KERN EMB200-2 EMB600-2 EMB220-1 EMB500-1
Readout 0,01 g 0,01 g 0,1 g 0,1 g Weighing range 200 g 600 g 220 g 500 g Reproducibility 0,01 g 0,01 g 0,1 g 0,1 g Linearity ± 0,02 g ± 0,03 g ± 0,2 g ± 0,3 g
Adjusting weight (not included)
Stabilization time 2-3 sec. AUTO-OFF-Function
(in battery mode) Units g / oz / ozt / dwt
Operating temperature 0° C .... + 40° C
Air humidity max. 80 % (non-condensing) Case (W x D x H) mm 170x240x39 Weighing plate mm Ø 105 Ø 150 Battery supply (standard) 1 x 9 V Mains adapter (optional) 300 mA / 9V Underfloor weighing Hanging loop below the cover plate as standard
KERN EMB1200-1 EMB2200-0 EMB5.2K1 EMB5.2K5
Readout 0,1 g 1 g 1 g 5 g
200g (F2) 500g (F2)
after 3 min.
200 g (M1)
AA(2x 1,5V) 9V
200g (M1)
Weighing range 1.200 g 2.200 g 5.200 g 5.200 g Reproducibility 0,1 g 1 g 1 g 5 g Linearity ± 0,2 g ± 2 g ± 3 g ± 10 g
Adjusting weight (not included) 1.000 g (M1) 1.000 g (M1) 2.000 g (M1) 2.000g (M1)
Stabilization time 2-3 sec. AUTO-OFF-Function
(in battery mode) Units g / oz / ozt / dwt
Operating temperature 0° C .... + 40° C
Air humidity max. 80 % (non-condensing) Case (W x D x H) mm 170x240x39 Weighing plate mm Ø 150 Battery supply (standard) 9V AA (2x 1,5V) 9V AA (2x 1,5 V) Mains adapter (optional) 300 mA / 9V Underfloor weighing Hanging loop below the cover plate as standard
after 3 min.
EMB-BA-defsi-0522
15
2 Declaration of conformty
KERN & Sohn GmbH
D-72322 Balingen-Frommern Postfach 4052 E-Mail: info@kern-sohn.de
Tel: 0049-[0]7433- 9933-0 Fax: 0049-[0]7433-9933-149 Internet: www.kern-sohn.de
Konformitätserklärung
Declaration of conformity for apparatus with CE mark
Konformitätserklärung für Geräte mit CE-Zeichen
Déclaration de conformité pour appareils portant la marque CE
Declaración de conformidad para aparatos con disitintivo CE
Dichiarazione di cofnromitá per apparecchi contrassegnati con la marcatura CE
English
Deutsch
Français
Español
Italiano
We hereby declare that the product to which this declaration refers conforms with the fol­lowing standards.
Wir erklären hiermit, dass das Produkt, auf das sich diese Erklärung bezieht, mit den nach­stehenden Normen übereinstimmt.
Nous déclarons avec cela responsabilité que le produit, auquel se rapporte la présente déclaration, est conforme aux normes citées ci-après.
Manifestamos en la presente que el producto al que se refiere esta declaración est´´a de acuerdo con las normas siguientes
Dichiariamo con ciò che il prodotto al quale la presente dichiarazione si riferisce è confor­me alle norme di seguito citate.
Electronic Balances: KERN EMB
Mark applied EU Directive Standards
89/336EEC EMC EN 61000-6-3 : 2001
EN 61000-3-2 : 2000 EN 61000-3-3 : 1995+A1 : 2001 EN 61000-6-1 : 2001
Date: 15.11.2005 Signature:
Gottl. KERN & Sohn GmbH, Ziegelei 1, D-72336 Balingen, Tel. +49-[0]7433/9933-0,Fax +49-[0]7433/9933-149
Gottl. KERN & Sohn GmbH Management
16
EMB-BA-defsi-0421
3 Fundamental information (general)
3.1 Intended use
The balance you have acquired serves to determine the weighing value of the mate­rial to be weighed. It is intended to be used as a “non-automatic“ balance, i.e. the material to be weighed is manually and carefully placed in the centre of the weighing plate. The weighing value can be read off after a stable weighing value has been ob­tained.
3.2 Inappropriate use
Do not use the balance for dynamic weighing. In the event that small quantities are removed or added to the material to be weighed, incorrect weighing results can be displayed due to the “stability compensation“ in the balance. (Example: Slowly drain­ing fluids from a container on the balance.) Do not leave a permanent load on the weighing plate. This can damage the measur­ing equipment. Be sure to avoid impact shock and overloading the balance in excess of the pre­scribed maximum load rating (max.), minus any possible tare weight that is already present. This could cause damage to the balance. Never operate the balance in hazardous locations. The series design is not explo­sion-proof. Structural alterations may not be made to the balance. This can lead to incorrect weighing results, faults concerning safety regulations as well as to destruction of the balance. The balance may only be used in compliance with the described guidelines. Varying areas of application/planned use must be approved by KERN in writing.
3.3 Guarantee
The guarantee is not valid following
- non-observation of our guidelines in the operating instructions
- use outside the described applications
- alteration to or opening of the device
- mechanical damage and damage caused by media, liquids
- natural wear and tear
- inappropriate erection or electric installation
- overloading of the measuring equipment
3.4 Monitoring the test substances
The metrology features of the balance and any possible available adjusting weight must be checked at regular intervals within the scope of quality assurance. For this purpose, the answerable user must define a suitable interval as well as the nature and scope of this check. Information is available on KERN’s home page (www.kern-
sohn.com) with regard to the monitoring of balance test substances and the test
weights required for this. Test weights and balances can be adjusted quickly and at a reasonable price in KERN’s accredited DKD calibration laboratory (return to na­tional normal).
EMB-BA-defsi-0522
17
4 Fundamental safety information
4.1 Observe the information in the operating instructions
Please read the operating instructions carefully before erecting and commissioning, even if you already have experience with KERN balances.
4.2 Staff training
The device may only be operated and looked after by trained members of staff.
5 Transport and storage
5.1 Acceptance check
Please check the packaging immediately upon delivery and the device during un­packing for any visible signs of external damage.
5.2 Packaging
Please retain all parts of the original packaging in case it should be necessary to re­turn items at any time. Only the original packaging should be used for return consignments. Before despatch, disconnect all attached cables and loose/movable parts. Secure all parts, e.g. power unit etc., to prevent slipping and damage.
18
EMB-BA-defsi-0421
6 Unpacking, installation and commissioning
6.1 Place of installation, place of use
The balance is constructed in such a way that reliable weighing results can be achieved under normal application conditions. By selecting the correct location for your balance, you will be able to work quickly and precisely.
Therefore please observe the following at the place of installation:
Place the balance on a firm, level surface;
Avoid extreme heat as well as temperature fluctuation caused by installing next to a radiator or in the direct sunlight;
Protect the balance against direct draughts due to open windows and doors;
Avoid jarring during weighing;
Protect the balance against high humidity, vapours and dust;
Do not expose the device to extreme dampness for longer periods of time. In­admissible bedewing (condensation of air moisture on the device) can occur if a cold device is taken into a significantly warmer environment. In this case, please acclimatise the device for approx. 2 hours at room temperature after it has been disconnected from the mains.
Avoid static charging of the material to be weighed, weighing container and windshield.
Major display deviations (incorrect weighing results) are possible if electromagnetic fields occur as well as due to static charging, currents and instable power supply. It is then necessary to change the location.
EMB-BA-defsi-0522
19
6.2 Unpacking
Carefully remove the balance from its packaging, remove the plastic wrapping and position the balance in its intended working location.
6.2.1 Installation
Install the balance in such a fashion that the weighing plate is absolutely horizonta
6.2.2 List of items supplied
Standard accessories:
KERN EMB
Balance
Operating manual
Batteries (2 x 1,5 V) or 1 x 9 V
Hook for underfloor weighing
6.3 Battery Operation
Remove the battery cover from the bottom of the balance. Connect 2 x 1,5V or 1
x
9V batteries (EMB 200-2/EMB600-2 Block-Battery 9 V). Re-insert the battery cover. Battery conservation through automatic power-off 3 minutes after ending a weighing operation.
When the battery power is used up the display will show “LO“. Press the key and change the batteries at once. When the balance is not in use for a longer period of time remove batteries and keep them separately. Leakage of battery liquid might damage the balance.
6.4 Mains supply
Electric power supply is by means of the external mains supply circuit. The printed voltage level must comply with the local voltage. Only use original KERN mains supply circuits. The use of other makes is subject to approval by Kern.
6.5 Initial start-up
A warm-up time of 3 minutes stabilises the measured values after switching on.
The accuracy of the balance depends on the local acceleration of the fall. Please be sure to observe the information in the chapter on adjusting.
20
EMB-BA-defsi-0421
6.6 Adjustment
As the acceleration value due to gravity is not the same at every location on earth, each balance must be coordinated – in compliance with the underlying physical weighing principle - to the existing acceleration due to gravity at its place of location ( only if the balance has not already been adjusted to the location in the factory). This adjustment process must be carried out during the initial start-up, after change in lo­cation and variation of surrounding temperature. It is also recommendable to adjust the balance periodically during weighing operation in order to obtain exact measured values.
6.6.1 Adjusting
Using a precision weight, the accuracy of the balance can be checked at any time and adjusted.
Adjustment procedure:
Check that the surrounding conditions are stable. A short warm-up time of about 3 minutes is recommended for stabilisation.
Use the key to switch the balance on.
Press the key and hold depressed for approx. 10 seconds until “CAL“ ap-
pears on the display.
Release the key; the size of the calibration weight is shown on the display (see chapter 1, Technical Data).
Now place the calibration weight in the centre of the weighing plate.
F“ will appear for a brief period of time before the balance switches off.
Remove the calibration weight. Calibration is completed.
In case of an adjusting error or a wrong adjusting weight “E“ will appear. Repeat the adjusting procedure. Keep the adjusting weight near the balance. Daily verification of the balance accu­racy is recommended for quality assured applications.
EMB-BA-defsi-0522
21
6.7 Underfloor weighing
Objects which, because of their size or shape, cannot be put on the scale, can be weighed by means of underfloor weighing.
Proceed as follows:
Switch off the balance.
Turn the balance over.
Open the cover plate (1) on the base of the balance.
Hang on the hook for underfloor weighing (2).
Place the balance over an opening.
Hang the item to be weighed on the hook and carry out weighing.
Fig. 1: Setting up the balance for underfloor weighings
!
CAUTION
For the underfloor weighing use only the original hook of KERN.
Take care that all hanged items are stable enough to hold the goods which you
wish to weigh (!!Danger of breaking!!).
Never hang goods more than the maximum permitted weight
(!!Danger of breaking!!).
Always make sure that there are no living beings or materials below the load that could be injured or damaged.
NOTE
After completing the underfloor weighing, the opening in the floor of the balance must be closed again (dust protection).
22
EMB-BA-defsi-0421
7 Operation
7.1 Overview of the keypad
Key Pressed briefly Pressed for 10 sec
7.2 Operating instructions
7.2.1 Weighing
The balance is switched on by pressing the key.
The balance performs auto-diagnostics (for 2 s) and then displays "0".
If the weighing object is heavier than the weighing range the display indicates
"E" (=Overload).
The balance is switched off by pressing the key once.
Switching the balance on Tara-Function
Switching the balance off
Unit changing
Adjusting function
7.2.2 Taring
Place tare cup on the weighing plate and press tion changes now to "0".The weight of the cup is now memorised.
Fill weighing object in the cup, read measuring value.
By pressing
in the display.
The taring procedure can be repeated several times, for instance to produce a mix­ture of several components.
The limit is reached when the total weighing range has been used. After removal of the tare cup the total weight appears as a negative value with „-„
mark.
EMB-BA-defsi-0522
key, after the terminated weighing operation "0" appears again
key. The weighing indica-
23
7.2.3 Units
Different foreign weighing units are integrated into the various balance models . Change the Units with the key. Press an hold the key , few seconds later change the unit.
Display Conversion factor
1 g =
Gramm g 1.
Unze oz 0.035273962 Troy Unze ozt 0.032150747 Pennyweight dwt 0.643014931
8 Maintenance, upkeep, disposal
8.1 Cleaning
Please disconnect the device from the operating voltage before cleaning. Only use a cloth dampened with mild suds and not aggressive cleaning agents (sol-
vents or similar). Please ensure that fluids are not able to get into the device and rub off using a clean, soft cloth. Loose sample residue/powder can be removed carefully using a brush or hand vac­uum cleaner.
Remove any spilt material to be weighed immediately.
8.2 Maintenance, upkeep
The device may only be opened by trained service engineers authorised by KERN. Disconnect from the mains supply before opening.
8.3 Disposal
The operating company shall dispose of the packaging and the device in compliance with the valid national or regional law of the operating location.
24
EMB-BA-defsi-0421
9 Troubleshooting
The balance should be switched off for a short time following an interruption in the programme sequence and disconnected from the mains supply. It is then necessary to repeat the weighing process from the beginning.
Help:
Interruption Possible cause
Weight display is not illuminated.
The weight display changes continu­ally
The balance is not switched on.
The batteries are wrongly inserted, the
batteries are empty
No batteries are attached
The mains supply connection has been
interrupted (mains cable not plugged in/faulty).
Power supply interrupted. .
Draught/air movement
Table/floor vibrations
The weighing plate is in contact with for-
eign matter.
Electromagnetic fields / static charging (choose different location/switch off inter­fering device if possible)
The weighing result is obviously in­correct
Switch the balance off if other error messages should appear and then switch on again. Contact the manufacturer if the error message does not disappear.
EMB-BA-defsi-0522
The balance display is not set to zero
Adjustment is no longer correct.
Great fluctuations in temperature.
Electromagnetic fields / static charging
(choose different location/switch off inter­fering device if possible)
25