Keri Systems NXT-8IN, NXT-8OUT, NXT-GIOX Specsheet

GIOX
Greater Input/Output Module
Unit shown with and without enclosure (available in both configurations)
Data Sheet
Expands Auxiliary Input and Output capability for NXT controllers
Up to 64 Inputs/Outputs (in banks of 8) per NXT Controller Bus
Up to two GIOX units on an NXT-2D and up to four units on an NXT-4D
Re-assignable/interchangeable with Controller’s door I/O
4-State Supervision on Inputs
Tamper and Emergency Inputs
Status Indicators for power, communication, and relay position
Quick disconnect connectors
Keri’s GIOX Greater Input/Output Module is much like the NXT-4X4 I/O Module except it has far greater capacity. It is designed to expand the flexibility of any installation by providing additional access control functionality as well as sophisticated input monitoring and I/O linkage macro capability for NXT hardware-based systems with large numbers of sensors and devices. It is perfectly suited for elevator control for buildings with more than 20 floors when combined with Doors.NET software’s Elevator Control option.
GIOX is comprised of a motherboard with connectors onto which Input boards and Output boards can be attached. Each board has eight Inputs or eight Outputs, and up to eight boards can be connected to each motherboard. The motherboard contains the RS-485 bus connection for the NXT controller as well as the power input, tamper monitoring input, and an emergency switch input which removes power from all relays on all relay boards.
Note - If using the inputs for monitoring or the outputs for manual operation only, NXT controllers with standard Keri firmware may be used.
If elevator control or I/O linking is required, use Mercury Powered NXT hardware.
2305 Bering Drive • San Jose, California 95131
408-435-8400 • Toll Free: 800-260-5265 • Fax: 408-577-1792
p/n 01251-001 Rev. A
email: sales@kerisys.com web: www.kerisys.com
GIOX
Greater Input/Output Module
Specifications:
Model Numbers:
KE-8 Enclosure
NXT-GIOX Motherboard w/Mounting Plate
NXT-8IN Input Board
NXT-8OUT Output Board - NXT
Size:
Enclosure
17.25 W x 15.25 T x 6.75 D inches
43.82 W x 38.74 T x 17.15 D cm
Motherboard w/Mounting Plate
15.45 W x 11.56 T x2.00 D inches
39.24 W x 29.36 T x 5.08 D cm
Weight:
Enclosure - 13.61 lbs (6.17 kg)
Motherboard w/Mounting Plate - 1.65 lbs (.75 kg)
Input Board - 0.35 lbs (159 g)
Output Board - 0.10 lbs (45 g)
Inputs:
8 per Module
2-State or 4-State Supervision
Outputs:
8 dry-contact relays per Module
Contact Rating - 1 A @ 24 VDC
Operating Conditions:
32° F to 150° F (0° C to 60° C)
0% to 90% Relative Humidity
Non-Condensing
Inputs:
8 per Module
User selectable, 2-State, 4-State, or no Supervision
Outputs:
8 dry-contact relays per Module
Contact Rating - 1 A @ 24 VDC
Presented By:
Power Requirements:
NXT Controller Power - Using NO Output Boards
10 to 14 VDC @ 1.5 A Max (for a unit with up to 8 input boards)
Current
Motherboard Only - 100 mA
Motherboard w/Reader & RIM - 200 mA
Input Board - 75 mA per board
Stand Alone Power Supply - Using Any Output Boards
10 to 14 VDC @ 3.5 A Max (for a unit with up to 8 output boards)
Current
Motherboard Only - 100 mA
Motherboard w/Reader & RIM - 200 mA
Output Board - 300 mA per board