MS-7000: SuperStar Reader
The MS-7000 SuperStar Reader
The MS-7000 SuperStar Reader is intended for installation in proximity applications where an
extended read range is required. The reader provides an audible beeper and a multi colored LED to
annunciate the reader's status when used on a PXL-250, PXL-100, or IntelliProx.
• Amber - to indicate normal operation awaiting an access event
• Green - to indicate a valid card has been presented or the door has been unlocked for access
• Red - to indicate an invalid card has been presented or the door is in an alarm condition
The MS-7000 SuperStar Reader is housed in a black or white, weatherproof, shock resistant
package. The reader provides optimum performance when mounted at least four inches away from
metal surfaces; read range is reduced if the reader is mounted on or near metal surfaces.
1.0 Specifications
1.1 Dimensions
• 8.50 inches High x 6.00 inches Wide x 0.75 inches Deep
• 21.59 cm High x 15.24 cm Wide x 1.91 cm Deep
Figure 1: MS-7000 Dimensions
MS-7000Quick Start Guide
2305 Bering Drive 01826-001 Rev. G
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: www.kerisys.com E-mail: sales@kerisys.com Page 1 of 8

MS-7000: SuperStar Reader
1.2 Operating Voltage
• 11v to 14v DC @ 200 ma
1.3 Cable Specifications
• up to 250 feet using six conductor, shielded, stranded AWG 24 wire
• up to 500 feet using six conductor, shielded, stranded AWG 20 wire
2.0 Mounting Instructions
Five holes need to be drilled to mount the SuperStar Reader (see Figure 1 on page 1). One hole
(0.375" – 3/8") accommodates the reader cable. Four holes are for mounting the reader on a wall
surface (hole size is dependent upon the size of the mounting screw - a #10 screw is recommended).
A small recess may be necessary to accommodate the beeper (0.75" – 3/4" x 0.20" Deep).
Quick Start GuideMS-7000
For parking or similar applications, the SuperStar Reader can be mounted to a metal "gooseneck"
stand. Since the Reader cannot be mounted directly to a metal surface without affecting read range,
the Reader must be mounted on some kind of a nonmetallic mounting plate, which is then mounted
to the gooseneck stand. The larger the mounting surface of the gooseneck stand, the greater the
distance required between reader and mounting surface.
A nonmetallic (PVC) mounting plate is provided for these applications. For a stand with a mounting
surface of 4 inches by 4 inches or smaller, the MP-7 mounting plate provides 1/2 inch of separation
between the reader and the gooseneck mounting surface. If the mounting surface is larger than these
dimensions, additional mounting plates may be necessary to provide the necessary distance
between Reader and stand to ensure optimum read range (available from Keri Systems – p/n MP-7).
NOTE: Do not mount the reader near sources of Electromagnetic Interference (EMI) such as a
computer monitor. EMI degrades a reader's read range.
3.0 Connections
The SuperStar Reader does not require configuration; there are no switches or jumpers to set. The
SuperStar Reader is normally connected to a PXL-250, PXL-100, or IntelliProx, but can be
connected to an alternative host controller/alarm panel through an IntelliProx used in its Wiegand
input device mode. All connections needed to support the reader are made through the reader's
cable. Please consult the tables on pages 2 and 3 for specific connection instructions.
2305 Bering Drive 01826-001 Rev. G
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: www.kerisys.com E-mail: sales@kerisys.com Page 2 of 8

MS-7000: SuperStar Reader
3.1 PXL-250 Connections
The "A" reader connects to TB5, pins 1 through 6 (TB5 has a seventh pin, but no connection is
made to that pin). The "B" reader connects to TB6, pins 1 through 6 (TB6 has a seventh pin, but no
connection is made to that pin).
Connecting to the PXL-250 –TB5 or TB6
Pin # Function Wire Color
1 Reader Antenna Blue
2 Beeper Green
3 Reader Power Red
4 Reader Ground Black
4 Shield Silver
5 Green LED Brown
6 Red LED White
7 no connection –
Figure 2: PXL-250 Connections
3.2 Design 5 PXL-100 Connections
The "A" reader connects to TB2, pins 14 through 19. The "B" reader connects to TB3, pins 20
through 25.
MS-7000Quick Start Guide
2305 Bering Drive 01826-001 Rev. G
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: www.kerisys.com E-mail: sales@kerisys.com Page 3 of 8