KEPCO RMW 300W User Manual

QUICK START GUIDE
An ISO 9001 Company.
RMW
300W, PFC, OPEN FRAME
POWER SUPPLIES
I — INTRODUCTION
SCOPE OF MANUAL. This Quick Start Guide covers
the installation and operation of the Kepco RMW Series of Open Frame Switching Power Supplies. Full specifications are listed in the Operator Manual that can be downloaded from the Kepco web site:
• www.kepcopower.com/support/opmanls.htm#rmw
DESCRIPTION. Kepco RMW Series are 300W RoHS­compliant switching power supplies with seven models pro­viding 5V, 12V, 15V, 24V, 28V, 48V and a triple output model (RMW 51212-300K) which provides a primary output of +5V and secondary outputs of ±12V). All models also
TABLE 1. RMW OPEN FRAME MODELS
VOLTAGE 5V 5V, ±12V 12V 15V 24V 28V 48V
MODEL RMW 5-60K RMW 51212K-300 RMW 12-25K RMW 15-20K RMW 24-12K RMW 28-11K RMW 48-6.2K
include a separate +12V output that can be used to power an external cooling fan and an output suitable for driving an LED. Power Factor Correction (PFC) is included in all mod­els.
Units may be operated with a nominal 115V a-c or 230V a-c (input voltage range 85 to 264 Va-c), 50-60 Hz (input fre­quency range 47-66Hz). If overvoltage protection trips, the unit shuts down; it is necessary to cycle input power off, then on to reset the unit. Overcurrent protection with auto­matic recovery from short circuit is featured (except for sin­gle-and triple output 5V models that latch off when overcurrent or short-circuit is detected). Units are convec­tion cooled U-chassis construction.
Open Frame
II — INSTALLATION
MOUNTING THE POWER SUPPLY. Refer to Figure
1. The unit may be mounted using 6-32 mounting screws (not supplied). Eight mounting holes are provided: four on the base, and two on each side. Note the restrictions for maximum penetration of mounting screws (see Figure 1). .
FIGURE 1. MOUNTING SCREW PENETRATION
CONNECTIONS. All connections are made via TB1 through TB5 (see Figure 2 for locations). AC input power is
TABLE 1. TB2 DC OUTPUT PIN ALLOCATION
MODEL 1 2 3 4 5 6 7 8 9 10 11 12
RMW 5-60K
RMK 51212K-300 +5V GND +12V –12V --- ---
RMW 12-25K +12V GND RTN (+12V) +12V --- --- --- --­RMW 15-20K +15V GND RTN (+12V) +12V --- --- --- --­RMW 24-12K +24V GND RTN (+12V) +12V --- --- --- --- --- -­RMW 28-11K +28V GND RTN (+12V) +12V --- --- --- --- --- --
RMW 48-6.2K +48V GND RTN (+12V) +12V --- --- --- --- --- --
(1) CAUTION: Limit RMW 5-60K to 15A maximum per output terminal to avoid overheating
KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000 FAX (718) 767-1102
©2010, KEPCO, INC 1 Data subject to change without notice 228-1690
(1)
+5V
http://www.kepcopower.com email: hq@kepcopower.com
applied via the terminal block TB1. Connect the AC input Neutral, Line and Earth Ground wires to the respective ter­minals of the terminal block (see Figure 2). TB2 provides the DC outputs; see Table 1 for pin allocation. TB3, TB4 and TB5 are each 2-pin connectors that require a Molex 5045-02A (or equivalent) mating connector. TB3 provides a floating +12V output for use with an auxiliary fan (not sup­plied). TB4 provides ± connections used for remote sens­ing. TB5 provides connections used to drive an external Power OK LED (not supplied).
Figure 3 shows proper connection of one or more loads. If
oscillations set off overvoltage protection, install one elec­trolytic capacitor (470µF min) between +S and + and one between – and –S terminals.
OUTPUT TERMINAL
GND +5V RTN (+12V) +12V
FIGURE 2. COMPONENT LOCATIONS
III — OPERATION
When output voltage is available, the output at TB5 is available to drive an external LED and the +12V output at TB3 is available to power an external cooling fan. The
A
B
Output Voltage Adjust trimmer (see Figure 2) allows adjustment of the primary output voltage.
C
FIGURE 3. LOAD CONNECTIONS
KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000 FAX (718) 767-1102
2 228-1690 072710
http://www.kepcopower.com email: hq@kepcopower.com