INSTRUCTION MANUAL
KEPCO
An ISO 9001 Company.
DIN-RAIL MOUNTING KIT
FOR SERIES HSM
DESCRIPTION. Kepco Kit, Model DIN HSM-L contains a
protective cover and a preassembled mounting plate and
associated hardware used to install HSM 1000 and 1500
Watt Series power supplies on a DIN rail. The “L” suffix is
for mounting perpendicular to the long dimension (length)
as shown in Figure 1. Outline dimensions are shown in
Figure 5.
1. INSTALLING KIT. Attach the preassembled mounting
plate to the power supply using the hardware supplied (see
Figure 4).
2. INSTALLING POWER SUPPLY ON DIN RAIL. To
mount the power supply on the rail insert one end of both
clips under one edge of the rail, then snap the other end of
the clips into place (see Figure 3A).
NOTE: For applications where the installed power supply
may be subject to unusual levels of shock or vibration, or where the power supply is oriented such
that it may slide down the rail due to gravity, the use
of two DIN rail end stops (Kepco P/N 108-0367) is
recommended. After installing the power supply on
the rail, the end stops are installed by clearing the
DIN rail of other components and sliding the end
stops over the rail. When the end stops are secure
against the power supply, tighten the two integral
screws of each end stop.
KIT
DIN HSM-L
FIGURE 1. L SUFFIX ORIENTATION
3. WIRE POWER SUPPLY. Refer to HSM manual.
4. INSTALLING PROTECTIVE COVER. Peel off the paper
coating protecting the cover. Attach the protective cover to
the power supply using two plastic rivets inserted in the
ventilation holes at either the top (see Figure 2) or the side.
REMOVING POWER SUPPLY FROM DIN RAIL. While grasping the power supply with one hand, use a screwdriver to
apply leverage towards the left as shown in Figure 3B to disengage both clips from the rail.
INSTALLATION
A -
FIGURE 3. INSTALLATION AND REMOVAL OF POWER SUPPLY FROM DIN RAIL
KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11352 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102
http://www.kepcopower.com "
©2000, KEPCO, INC
Data subject to change without notice 228-1403
email: hq@kepcopower.com
FIGURE 2. INSTALL PROTECTIVE COVER
REMOVAL
B -
1

FIGURE 4. INSTALLATION OF KIT ON HSM POWER SUPPLY
FIGURE 5. HSM POWER SUPPLY WITH KIT INSTALLED, OUTLINE DIMENSIONS
KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11352 U.S.A. " TEL (718) 461-7000 "
2
http://www.kepcopower.com " email: hq@kepcopower.com
228-1403 061901
FAX (718) 767-1102