INSTRUCTION SHEET
KEPCO
An ISO 9001 Company.
FIRMWARE UPGRADE UTILITY
I — INTRODUCTION
SCOPE OF MANUAL. This Instruction Sheet covers the
installation and use of Kepco’s Firmware Upgrade Utility.
DESCRIPTION. The Kepco Firmware Upgrade Utility
allows selected Kepco products to be upgraded to the latest Firmware without replacing any parts. The Firmware
Upgrade Utility is available from the Kepco web site at
www.kepcopower.com/utilities/util.htm
NOTE: Check the web page referenced above to verify
that your Kepco product and/or Firmware version is 1) eligible to use this method to upgrade
the firmware and 2) note any requirements for
the port used to perform the upgrade.
Firmware
Upgrade
III — OPERATION
After the Firmware Upgrade Utility has been installed, proceed as follows:
1. At your PC go to Start - Programs - Kepco - Utilities Firmware Upgraded to run the Firmware Upgrade Utility.
2. At the top menu bar, click Bus Selection (see Figure 1)
and choose RS 232, IEEE 488 (GPIB) or LAN as the
interface bus to use during the upgrade process.
3. Depending on the bus selected, enter the following
a. RS 232: Select applicable COM Port and Baud Rate
(see Figure 1).
II — INSTALLATION
1. Download and open the zip file from
www.kepcopower.com/utilities/util.htm
2. Run the file called setup and follow the instructions to
install the program on your PC. The upgrade utility is
self-contained and does not require VISA to be installed
on your PC.
3. Installing the Firmware Upgrade utility accomplishes:
• Start Menu updated with KEPCO folder and UTLITIES subfolder.
• Program Files Folder updated with KEPCO subfolder and UTILITIES sub-subfolder containing all
files required for upgrade, including a runtime executable for CVI that performs the upgrade without
affecting prior installations of CVI.
4. Verify communication between the power supply and PC
using either the RS 232, GPIB (IEEE 488) or LAN bus.
FIGURE 1. OPENING SCREEN, RS 232 SELECTED
KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000 FAX (718) 767-1102
http://www.kepcopower.com email: hq@kepcopower.com
©2010, KEPCO, INC 1
Data subject to change without notice 228-1686 REV 1

b. IEEE 488: Select applicable GPIB board and GPIB
address of the power supply (Figure 2).
FIGURE 2. GPIB (IEEE 488) SELECTED
c. LAN: Enter applicable IP Address of the power sup-
ply (see Figure 3).
FIGURE 3. LAN SELECTED
4. Enter the power supply password in the Unit Password field.
5. Click Select Filename to locate and select the firmware code file (e.g., klpupgrade V9_00.hex).
6. Click Start. The Model, Serial No. and Firmware Ver-
sion Before Update are displayed. The Messages box
displays Erasing to indicate the upgrade has started. If
an error message is displayed (e.g., wrong password,
device not found, etc.) correct the problem and click
Start again. If unable to correct the problem, contact
Kepco.
7. As the upgrade progresses, the Transmit indicator
lights periodically when data is being transmitted from
the PC to the power supply, and % progress is indicated both numerically and graphically.
9. When Firmware Version After Update shows the new
firmware version and the % Progress indicators show
100%, the update is complete.
FIGURE 4. UPGRADE COMPLETE
10.Click EXIT! at the top menu bar to exit the upgrade utility.
11.Download documentation applicable to the new firmware revision from the Kepco website at
www.kepcopower.com/support/opmals.htm.
12.For a brief list of differences between the old firmware
and the upgraded firmware, refer to the readme.txt file
included with the Firmware Upgrade utility.
8. When the upgrade is near completion, the message
Powering Up will be displayed.
KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000 FAX (718) 767-1102
http://www.kepcopower.com email: hq@kepcopower.com
2 228-1686 REV 1 033010