INSTRUCTION MANUAL
KEPCO
An ISO 9001 Company.
DIN-RAIL MOUNTING KIT
FOR SERIES FMP/FCP 3W, 10W
DESCRIPTION. Kepco KITs, Models DIN FMP/FCP-
3S, and -10S each contain a mounting plate with two
mounting clips and associated hardware used to install
FMP and FCP Series power supplies on a DIN rail.
The -3 suffix is for the 3 Watt Series, and -10 for the 10
Watt Series. The “S” suffix is for mounting the power
supply along the short dimension (width) as shown in
Figure 1.
TABLE 1. COMPONENTS SUPPLIED
KIT
MODEL NO.
DIN FMP/FCP-3S 189-0696 108-0365
MOUNTING
PLATE
PART NO.
CLIP (QTY 2)
PART NO.
DIN FMP/FCP
-3S, -10S,
FIGURE 1. S SUFFIX ORIENTATION
SCREW (QTY 2)
PART NO.
101-0092
(4-40 X 0.312 BHPH)
WASHER (QTY 2)
PAR T N O .
103-0014
(NO. 4, INT. TOOTH)
KIT
DIN FMP/FCP-10S 189-0697 108-0365
INSTALLATION
1. INSTALL MOUNTING PLATE. Attach the mounting plate to the power supply using the hardware supplied
(see Figure 2).
2. INSTALL CLIPS. Snap the two clips into the mounting plate holes (see Figure 3).
3. INSTALL POWER SUPPLY ON DIN RAIL. To mount the power supply on the rail insert one end of both
mounting clips under one edge of the rail, then snap the other end of the two clips into place (see Figure
4A).
101-0092
(4-40 X 0.312 BHPH)
103-0014
(NO. 4, INT. TOOTH)
FIGURE 2. INSTALLING MOUNTING
PLATE ON POWER SUPPLY
KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11352 U.S.A. " TEL (718) 461-7000 "
http://www.kepcopower.com " email: hq@kepcopower.com
©1998, KEPCO, INC
Data subject to change without notice 228-1308 (REV 1)
FIGURE 3. INSTALLING CLIPS ON
MOUNTING PLATE
FAX (718) 767-1102
1
REMOVING POWER SUPPLY FROM DIN RAIL. While grasping the power supply with one hand, Insert a screwdriver
into the access holes provided and apply leverage towards the left as shown in Figure 4B to disengage each clip from
the rail. Where mounting clips are close together, it may be necessary to apply leverage with two screwdrivers simultaneously.
INSTALLATION
A
FIGURE 4. INSTALLATION AND REMOVAL OF POWER SUPPLY FROM DIN RAIL
B
REMOVAL
FIGURE 5. OUTLINE DRAWING
KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11352 U.S.A. " TEL (718) 461-7000 "
2
http://www.kepcopower.com " email: hq@kepcopower.com
228-1308 061901
FAX (718) 767-1102